{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T10:24:59Z","timestamp":1785839099032,"version":"3.56.0"},"reference-count":52,"publisher":"IOP Publishing","issue":"20","license":[{"start":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T00:00:00Z","timestamp":1759795200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T00:00:00Z","timestamp":1759795200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Science and Technology Project of Fujian Province of China","award":["2021Y9154"],"award-info":[{"award-number":["2021Y9154"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["12375291"],"award-info":[{"award-number":["12375291"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"National Key Research and Development Program of China","award":["2023YFA1607502"],"award-info":[{"award-number":["2023YFA1607502"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2025,10,19]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> Pharmacokinetic (PK) parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) provide quantitative characterization of tissue perfusion and permeability. However, existing deep learning methods for PK parameter estimation rely on either temporal or spatial features alone, overlooking the integrated spatial-temporal characteristics of DCE-MRI data. This study aims to remove this barrier by fully leveraging the spatial and temporal information to improve parameter estimation. <jats:italic>Approach.<\/jats:italic> A spatial-temporal information-driven unsupervised deep learning method (STUDE) was proposed. STUDE combines convolutional neural networks (CNNs) and a customized Vision Transformer to separately capture spatial and temporal features, enabling comprehensive modeling of contrast agent dynamics and tissue heterogeneity. Besides, a spatial-temporal attention feature fusion module was proposed to enable adaptive focus on both dimensions for more effective feature fusion. Moreover, the extended Tofts model imposed physical constraints on PK parameter estimation, enabling unsupervised training of STUDE. The accuracy and diagnostic value of STUDE was compared with the orthodox non-linear least squares (NLLS) and representative deep learning-based methods (i.e. gated recurrent unit, convolutional neural network, U-Net, and VTDCE-Net) on a numerical brain phantom and 87 glioma patients, respectively. <jats:italic>Main results.<\/jats:italic> On the numerical brain phantom, STUDE produced PK parameter maps with the lowest systematic and random errors even under low signal-to-noise ratio (SNR) conditions (SNR = 10 dB). On glioma data, STUDE generated parameter maps with reduced noise compared to NLLS and demonstrated superior structural clarity compared to other methods. Furthermore, STUDE outshined all other methods in the identification of glioma isocitrate dehydrogenase mutation status, achieving the area under the curve (AUC) values at 0.840 and 0.908 for the receiver operating characteristic curves of <jats:italic>K<\/jats:italic>\n                  <jats:sup>trans<\/jats:sup> and V<jats:sub>e<\/jats:sub>, respectively. A combination of all PK parameters improved AUC to 0.926. <jats:italic>Significance.<\/jats:italic> STUDE advances spatial-temporal information-driven and physics-informed learning for precise PK parameter estimation, demonstrating its potential clinical significance.<\/jats:p>","DOI":"10.1088\/1361-6560\/ae0aaf","type":"journal-article","created":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T22:54:22Z","timestamp":1758668062000},"page":"205003","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Improved pharmacokinetic parameter estimation from DCE-MRI via spatial-temporal information-driven unsupervised learning"],"prefix":"10.1088","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-5102-9606","authenticated-orcid":false,"given":"Xinyi","family":"He","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qizhi","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiechao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen","family":"Xing","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dairong","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0600-8594","authenticated-orcid":true,"given":"Congbo","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2767-9490","authenticated-orcid":true,"given":"Shuhui","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,10,7]]},"reference":[{"key":"pmbae0aafbib1","doi-asserted-by":"publisher","first-page":"2564","DOI":"10.1002\/mrm.26903","type":"journal-article","article-title":"Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE\u2010MRI: results from a multicenter phantom study","volume":"79","author":"Bane","year":"2018","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib2","doi-asserted-by":"publisher","first-page":"2257","DOI":"10.1002\/mrm.27874","type":"journal-article","article-title":"Spatially regularized estimation of the tissue homogeneity model parameters in DCE-MRI using proximal minimization","volume":"82","author":"Bartos","year":"2019","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib3","doi-asserted-by":"publisher","first-page":"1712","DOI":"10.1109\/TMI.2019.2953901","type":"journal-article","article-title":"Efficient DCE-MRI parameter and uncertainty estimation using a neural network","volume":"39","author":"Bliesener","year":"2019","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae0aafbib4","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s00062-017-0590-z","type":"journal-article","article-title":"Glioma grading and determination of IDH mutation status and ATRX loss by DCE and ASL perfusion","volume":"28","author":"Brendle","year":"2018","journal-title":"Clin. Neuroradiol."},{"key":"pmbae0aafbib5","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1007\/978-3-540-85988-8_71","type":"conference-proceedings","article-title":"Automatic determination of arterial input function for dynamic contrast enhanced MRI in tumor assessment","author":"Chen","year":"2008"},{"key":"pmbae0aafbib6","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1016\/j.pathol.2016.07.010","type":"journal-article","article-title":"IDH1\/2 gene hotspot mutations in central nervous system tumours: analysis of 922 Chinese patients","volume":"48","author":"Chen","year":"2016","journal-title":"Pathology"},{"key":"pmbae0aafbib7","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1109\/MEMB.2004.1360410","type":"journal-article","article-title":"Dynamic magnetic resonance imaging of tumor perfusion","volume":"23","author":"Collins","year":"2004","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"pmbae0aafbib8","article-title":"An image is worth 16x16 words: transformers for image recognition at scale","author":"Dosovitskiy","year":"2020","type":"preprint"},{"key":"pmbae0aafbib9","doi-asserted-by":"publisher","first-page":"1898","DOI":"10.1002\/jmri.27495","type":"journal-article","article-title":"Convolutional neural network for accelerating the computation of the extended Tofts model in dynamic contrast-enhanced magnetic resonance imaging","volume":"53","author":"Fang","year":"2021","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmbae0aafbib10","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1109\/TBME.2023.3318087","type":"journal-article","article-title":"Normalizing flow-based distribution estimation of pharmacokinetic parameters in dynamic contrast-enhanced magnetic resonance imaging","volume":"71","author":"Fang","year":"2023","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmbae0aafbib11","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/j.media.2012.12.001","type":"journal-article","article-title":"Reliable estimation of incoherent motion parametric maps from diffusion-weighted MRI using fusion bootstrap moves","volume":"17","author":"Freiman","year":"2013","journal-title":"Med. Image Anal."},{"key":"pmbae0aafbib12","doi-asserted-by":"publisher","DOI":"10.1016\/j.engappai.2022.105151","type":"journal-article","article-title":"Ensemble deep learning: a review","volume":"115","author":"Ganaie","year":"2022","journal-title":"Eng. Appl. Artif. Intell."},{"key":"pmbae0aafbib13","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1002\/mrm.1910340618","type":"journal-article","article-title":"The Rician distribution of noisy MRI data","volume":"34","author":"Gudbjartsson","year":"1995","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib14","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1109\/TMI.2011.2174158","type":"journal-article","article-title":"Realistic analytical phantoms for parallel magnetic resonance imaging","volume":"31","author":"Guerquin-Kern","year":"2011","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae0aafbib15","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1002\/mrm.30307","type":"journal-article","article-title":"Physics-guided self-supervised learning: demonstration for generalized RF pulse design","volume":"93","author":"Jang","year":"2025","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib16","doi-asserted-by":"publisher","first-page":"1534","DOI":"10.1109\/TMI.2009.2019957","type":"journal-article","article-title":"Estimating kinetic parameter maps from dynamic contrast-enhanced MRI using spatial prior knowledge","volume":"28","author":"Kelm","year":"2009","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae0aafbib17","first-page":"1450","type":"conference-proceedings","article-title":"Arterial input function and tracer kinetic model-driven network for rapid inference of kinetic maps in dynamic contrast-enhanced MRI (AIF-TK-net)","author":"Kettelkamp","year":"2020"},{"key":"pmbae0aafbib18","doi-asserted-by":"publisher","DOI":"10.1118\/1.4898202","type":"journal-article","article-title":"Models and methods for analyzing DCE-MRI: a review","volume":"41","author":"Khalifa","year":"2014","journal-title":"Med. Phys."},{"key":"pmbae0aafbib19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.mri.2018.02.005","type":"journal-article","article-title":"Repeatability and correlations of dynamic contrast enhanced and T2* MRI in patients with advanced pancreatic ductal adenocarcinoma","volume":"50","author":"Klaassen","year":"2018","journal-title":"Magn. Reson. Imaging"},{"key":"pmbae0aafbib20","doi-asserted-by":"publisher","first-page":"1747","DOI":"10.1109\/TMI.2022.3147426","type":"journal-article","article-title":"Unsupervised MRI reconstruction via zero-shot learned adversarial transformers","volume":"41","author":"Korkmaz","year":"2022","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae0aafbib21","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1002\/jmri.23866","type":"journal-article","article-title":"Sampling requirements in DCE\u2010MRI based analysis of high grade gliomas: simulations and clinical results","volume":"37","author":"Larsson","year":"2013","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmbae0aafbib22","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1002\/mrm.24710","type":"journal-article","article-title":"Highly accelerated dynamic contrast enhanced imaging","volume":"71","author":"Lebel","year":"2014","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib23","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1002\/mrm.27725","type":"journal-article","article-title":"NMR shutter-speed elucidates apparent population inversion of 1H2O signals due to active transmembrane water cycling","volume":"82","author":"Li","year":"2019","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib24","doi-asserted-by":"publisher","first-page":"5753","DOI":"10.1088\/0031-9155\/56\/17\/018","type":"journal-article","article-title":"A novel AIF tracking method and comparison of DCE-MRI parameters using individual and population-based AIFs in human breast cancer","volume":"56","author":"Li","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"pmbae0aafbib25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40644-015-0039-z","type":"journal-article","article-title":"Glioma grading by microvascular permeability parameters derived from dynamic contrast-enhanced MRI and intratumoral susceptibility signal on susceptibility weighted imaging","volume":"15","author":"Li","year":"2015","journal-title":"Cancer Imaging"},{"key":"pmbae0aafbib26","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1002\/mrm.21336","type":"journal-article","article-title":"On the identifiability of pharmacokinetic parameters in dynamic contrast-enhanced imaging","volume":"58","author":"Lopata","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib27","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1002\/mrm.20022","type":"journal-article","article-title":"Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging","volume":"51","author":"Murase","year":"2004","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib28","first-page":"3163","type":"conference-proceedings","article-title":"Video transformer network","author":"Neimark","year":"2021"},{"key":"pmbae0aafbib29","doi-asserted-by":"publisher","first-page":"2481","DOI":"10.1056\/NEJMoa1402121","type":"journal-article","article-title":"Comprehensive, integrative genomic analysis of diffuse lower-grade gliomas","volume":"372","author":"Network C G A R","year":"2015","journal-title":"New Engl. J. Med."},{"key":"pmbae0aafbib30","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1088\/0031-9155\/53\/5\/005","type":"journal-article","article-title":"Computationally efficient vascular input function models for quantitative kinetic modelling using DCE-MRI","volume":"53","author":"Orton","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"pmbae0aafbib31","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2022.102512","type":"journal-article","article-title":"Deep learning DCE-MRI parameter estimation: application in pancreatic cancer","volume":"80","author":"Ottens","year":"2022","journal-title":"Med. Image Anal."},{"key":"pmbae0aafbib32","doi-asserted-by":"publisher","first-page":"2552","DOI":"10.1177\/02841851231180291","type":"journal-article","article-title":"Combined texture analysis of dynamic contrast-enhanced MRI with histogram analysis of diffusion kurtosis imaging for predicting IDH mutational status in gliomas","volume":"64","author":"Pan","year":"2023","journal-title":"Acta Radiol."},{"key":"pmbae0aafbib33","doi-asserted-by":"publisher","first-page":"693","DOI":"10.3174\/ajnr.A5569","type":"journal-article","article-title":"Whole-tumor histogram and texture analyses of DTI for evaluation of IDH1-mutation and 1p\/19q-codeletion status in World Health Organization grade II gliomas","volume":"39","author":"Park","year":"2018","journal-title":"Am. J. Neuroradiol."},{"key":"pmbae0aafbib34","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1002\/mrm.21066","type":"journal-article","article-title":"Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI","volume":"56","author":"Parker","year":"2006","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib35","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.1126\/science.1164382","type":"journal-article","article-title":"An integrated genomic analysis of human glioblastoma multiforme","volume":"321","author":"Parsons","year":"2008","journal-title":"Science"},{"key":"pmbae0aafbib36","doi-asserted-by":"publisher","first-page":"1560","DOI":"10.1002\/mp.16081","type":"journal-article","article-title":"VTDCE\u2010Net: a time invariant deep neural network for direct estimation of pharmacokinetic parameters from undersampled DCE MRI data","volume":"50","author":"Rastogi","year":"2023","journal-title":"Med. Phys."},{"key":"pmbae0aafbib37","doi-asserted-by":"publisher","first-page":"1991","DOI":"10.1007\/s00330-015-4012-9","type":"journal-article","article-title":"Assessment of repeatability and treatment response in early phase clinical trials using DCE-MRI: comparison of parametric analysis using MR- and CT-derived arterial input functions","volume":"26","author":"Rata","year":"2016","journal-title":"Eur. Radiol."},{"key":"pmbae0aafbib38","first-page":"234","type":"conference-proceedings","article-title":"U-net: convolutional networks for biomedical image segmentation","author":"Ronneberger","year":"2015"},{"key":"pmbae0aafbib39","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1109\/TMI.2006.884210","type":"journal-article","article-title":"Bayesian methods for pharmacokinetic models in dynamic contrast-enhanced magnetic resonance imaging","volume":"25","author":"Schmid","year":"2006","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae0aafbib40","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1002\/mrm.22861","type":"journal-article","article-title":"On the scope and interpretation of the Tofts models for DCE\u2010MRI","volume":"66","author":"Sourbron","year":"2011","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib41","doi-asserted-by":"publisher","first-page":"1004","DOI":"10.1002\/nbm.2940","type":"journal-article","article-title":"Classic models for dynamic contrast-enhanced MRI","volume":"26","author":"Sourbron","year":"2013","journal-title":"NMR Biomed."},{"key":"pmbae0aafbib42","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1002\/(SICI)1522-2586(199909)10:3<223::AID-JMRI2>3.0.CO;2-S","type":"journal-article","article-title":"Estimating kinetic parameters from dynamic contrast-enhanced T1-weighted MRI of a diffusable tracer: Standardized quantities and symbols","volume":"10","author":"Tofts","year":"1999","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmbae0aafbib43","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.3389\/fneur.2018.01147","type":"journal-article","article-title":"Convolutional neural networks for direct inference of pharmacokinetic parameters: application to stroke dynamic contrast-enhanced MRI","volume":"9","author":"Ulas","year":"2019","journal-title":"Front. Neurol."},{"key":"pmbae0aafbib44","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2025.107889","type":"journal-article","article-title":"A versatile end-to-end deep learning framework for improved full-automatic MRI hemodynamic parameter estimation","volume":"108","author":"Wang","year":"2025","journal-title":"Biomed. Signal Process. Control"},{"key":"pmbae0aafbib45","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1002\/mrm.29574","type":"journal-article","article-title":"Accelerated and quantitative three-dimensional molecular MRI using a generative adversarial network","volume":"89","author":"Weigand Whittier","year":"2023","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib46","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1002\/mrm.21912","type":"journal-article","article-title":"Reproducibility assessment of a multiple reference tissue method for quantitative dynamic contrast enhanced\u2013MRI analysis","volume":"61","author":"Yang","year":"2009","journal-title":"Magn. Reson. Med."},{"key":"pmbae0aafbib47","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1016\/j.acra.2019.12.010","type":"journal-article","article-title":"DSC and DCE histogram analyses of glioma biomarkers, including IDH, MGMT, and TERT, on differentiation and survival","volume":"27","author":"Zhang","year":"2020","journal-title":"Acad. Radiol."},{"key":"pmbae0aafbib48","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad0e39","type":"journal-article","article-title":"Efficient estimation of pharmacokinetic parameters from breast dynamic contrast-enhanced MRI based on a convolutional neural network for predicting molecular subtypes","volume":"68","author":"Zhang","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbae0aafbib49","doi-asserted-by":"publisher","first-page":"2965","DOI":"10.1109\/TMI.2022.3175461","type":"journal-article","article-title":"Automatic liver tumor segmentation on dynamic contrast enhanced MRI using 4D information: deep learning model based on 3D convolution and convolutional LSTM","volume":"41","author":"Zheng","year":"2022","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae0aafbib50","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2024.103414","type":"journal-article","article-title":"Incorporating spatial information in deep learning parameter estimation with application to the intravoxel incoherent motion model in diffusion-weighted MRI","volume":"101","author":"Zijlstra","year":"2025","journal-title":"Med. Image Anal."},{"key":"pmbae0aafbib51","doi-asserted-by":"publisher","first-page":"3447","DOI":"10.1002\/mp.14222","type":"journal-article","article-title":"Estimation of pharmacokinetic parameters from DCE-MRI by extracting long and short time-dependent features using an LSTM network","volume":"47","author":"Zou","year":"2020","journal-title":"Med. Phys."},{"key":"pmbae0aafbib52","doi-asserted-by":"publisher","first-page":"3320","DOI":"10.1109\/TMI.2022.3184261","type":"journal-article","article-title":"Joint optimization of k-t sampling pattern and reconstruction of DCE MRI for pharmacokinetic parameter estimation","volume":"41","author":"Zou","year":"2022","journal-title":"IEEE Trans. Med. Imaging"}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T09:01:46Z","timestamp":1759827706000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae0aaf"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,7]]},"references-count":52,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2025,10,7]]},"published-print":{"date-parts":[[2025,10,19]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae0aaf","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,7]]},"assertion":[{"value":"Improved pharmacokinetic parameter estimation from DCE-MRI via spatial-temporal information-driven unsupervised learning","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2025-05-24","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-09-23","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-10-07","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}