{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T01:26:13Z","timestamp":1791595573544,"version":"4.3.4"},"reference-count":48,"publisher":"IOP Publishing","issue":"24","license":[{"start":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T00:00:00Z","timestamp":1766016000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T00:00:00Z","timestamp":1766016000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2025,12,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    To investigate the feasibility of neutron capture enhanced particle therapy (NCEPT) using synchrotron-accelerated carbon ion beams by evaluating the production and characteristics of thermal neutrons (with energies below 0.5 eV), which are optimal for neutron capture reactions.\n                    <jats:italic>Approach.<\/jats:italic>\n                    The fluence of thermal neutrons was measured via gold detector activation in a PMMA phantom irradiated with scanning carbon ion beams. Monte Carlo simulations using MCNP 6.2 were concurrently conducted to verify the experimental results and assess the potential for NCEPT dose enhancement under spread-out Bragg peak (SOBP) beam conditions.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The experimental measurement of thermal neutron fluence within the SOBP region was consistent with the Monte Carlo simulations. The simulations further revealed that the maximum neutron fluence appeared within the SOBP region. However, a quantitative comparison showed that the neutron fluence generated by the carbon ion beam is orders of magnitude lower than the minimum requirements for conventional BNCT. Consequently, the observed physical dose enhancement was not clinically significant.\n                    <jats:italic>Significance.<\/jats:italic>\n                    This study provides the first experimental evidence confirming the generation of thermal neutrons by synchrotron-accelerated scanning carbon ion beams. While the current neutron yield limits clinical utility, the spatial congruence between the maximum neutron fluence and the SOBP region remains a promising feature, serving as the basis for future research focusing on optimizing parameters of NCEPT.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae29de","type":"journal-article","created":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T23:50:07Z","timestamp":1765237807000},"page":"245024","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Experimental study of neutron yield in synchrotron-based carbon ion therapy: implications for neutron capture enhanced particle therapy"],"prefix":"10.1088","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-1096-0028","authenticated-orcid":true,"given":"Yu-Chun","family":"Chien","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1212-8162","authenticated-orcid":true,"given":"Tung-Sheng","family":"Hsieh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-1952-7369","authenticated-orcid":true,"given":"Hui-Chia","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chin-Hui","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Long-Sheng","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan-Hung","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1846-6381","authenticated-orcid":true,"given":"Shih-Ming","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,12,18]]},"reference":[{"key":"pmbae29debib1","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.apradiso.2017.07.031","type":"journal-article","article-title":"Characterisation of the secondary neutron field generated by a compact PET cyclotron with MCNP6 and experimental measurements","volume":"128","author":"Alloni","year":"2017","journal-title":"Appl. Radiat. Isot."},{"key":"pmbae29debib2","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1002\/cac2.12582","type":"journal-article","article-title":"Evaluation of sodium borocaptate (BSH) and boronophenylalanine (BPA) as boron delivery agents for neutron capture therapy (NCT) of cancer: an update and a guide for the future clinical evaluation of new boron delivery agents for NCT","volume":"44","author":"Barth","year":"2024","journal-title":"Cancer Commun."},{"key":"pmbae29debib3","doi-asserted-by":"publisher","first-page":"2676","DOI":"10.1016\/j.nimb.2011.08.010","type":"journal-article","article-title":"Nuclear reaction measurements of 95MeV\/u 12C interactions on PMMA for hadrontherapy","volume":"269","author":"Braunn","year":"2011","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbae29debib4","author":"Brown","year":"2013","type":"book"},{"key":"pmbae29debib5","doi-asserted-by":"publisher","first-page":"611","DOI":"10.4143\/crt.2021.066","type":"journal-article","article-title":"Physical and biological characteristics of particle therapy for oncologists","volume":"53","author":"Byun","year":"2021","journal-title":"Cancer Res. Treat."},{"key":"pmbae29debib6","doi-asserted-by":"publisher","first-page":"2887","DOI":"10.1016\/j.nds.2011.11.002","type":"journal-article","article-title":"ENDF\/B-VII.1 nuclear data for science and technology: cross sections, covariances, fission product yields and decay data","volume":"112","author":"Chadwick","year":"2011","journal-title":"Nucl. Data Sheets"},{"key":"pmbae29debib7","doi-asserted-by":"publisher","DOI":"10.1016\/j.nuclphysa.2021.122374","type":"journal-article","article-title":"Monoenergetic neutrons from the 9Be(p,n)9B reaction induced by 35, 40 and 45-MeV protons","volume":"1018","author":"Chavan","year":"2022","journal-title":"Nucl. Phys. A"},{"key":"pmbae29debib8","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1093\/rpd\/nch479","type":"journal-article","article-title":"NCRP report no. 144\u2014radiation protection for particle accelerator facilities national council on radiation protection and measurements issued 31 December 2003; revised 7 January 2005: NCRP, Bethesda, MD, USA ISBN: 0\u2013929600-77-0","volume":"113","author":"d\u2019Errico","year":"2005","journal-title":"Radiat. Prot. Dosim."},{"key":"pmbae29debib9","doi-asserted-by":"publisher","first-page":"7643","DOI":"10.1088\/0031-9155\/59\/24\/7643","type":"journal-article","article-title":"Nuclear reaction measurements on tissue-equivalent materials and GEANT4 Monte Carlo simulations for hadrontherapy","volume":"59","author":"De Napoli","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbae29debib10","first-page":"545","type":"journal-article","article-title":"Neutron attenuation through borated tissue equivalent material","volume":"45","author":"El Shazly","year":"2013","journal-title":"Isot. Radiat. Res."},{"key":"pmbae29debib11","doi-asserted-by":"publisher","DOI":"10.1088\/1367-2630\/10\/7\/075003","type":"journal-article","article-title":"Secondary beam fragments produced by 200\u2009MeV\u2009u\u22121 12C ions in water and their dose contributions in carbon ion radiotherapy","volume":"10","author":"Gunzert-Marx","year":"2008","journal-title":"New J. Phys."},{"key":"pmbae29debib12","doi-asserted-by":"publisher","first-page":"8265","DOI":"10.1088\/0031-9155\/58\/23\/8265","type":"journal-article","article-title":"Experimental study of nuclear fragmentation of 200 and 400 MeV\/u12C ions in water for applications in particle therapy","volume":"58","author":"Haettner","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbae29debib13","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1016\/j.net.2016.12.003","type":"journal-article","article-title":"An assessment of the secondary neutron dose in the passive scattering proton beam facility of the national cancer center","volume":"49","author":"Han","year":"2017","journal-title":"Nucl. Eng. Technol."},{"key":"pmbae29debib14","doi-asserted-by":"publisher","first-page":"439","DOI":"10.14338\/IJPT-15-00003.1","type":"journal-article","article-title":"A novel method for fragmentation studies in particle therapy: principles of ion identification","volume":"3","author":"Hartmann","year":"2017","journal-title":"Int. J. Part. Ther."},{"key":"pmbae29debib15","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.ijrobp.2024.02.052","type":"journal-article","article-title":"Neutron capture enhances dose and reduces cancer cell viability in and out of beam during helium and carbon ion therapy","volume":"120","author":"Howell","year":"2024","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbae29debib16","doi-asserted-by":"publisher","first-page":"3271","DOI":"10.1088\/0031-9155\/60\/8\/3271","type":"journal-article","article-title":"Reformulation of a clinical-dose system for carbon-ion radiotherapy treatment planning at the national institute of radiological sciences, Japan","volume":"60","author":"Inaniwa","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"pmbae29debib17","author":"International Atomic Energy Agency","year":"1970","type":"book"},{"key":"pmbae29debib18","year":"2001","type":"report"},{"key":"pmbae29debib19","author":"International Atomic Energy Agency","year":"2008","type":"report"},{"key":"pmbae29debib20","author":"International Atomic Energy Agency","year":"2023","type":"report"},{"key":"pmbae29debib21","doi-asserted-by":"crossref","DOI":"10.1007\/978-4-431-54457-9_3","type":"book","article-title":"Overview of the heavy-ion medical accelerator in Chiba (HIMAC) practices","author":"Kamada","year":"2014"},{"key":"pmbae29debib22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2024.104866","type":"journal-article","article-title":"An exploratory study of shielding strategies for boron neutron capture discrimination in 10B neutron capture enhanced particle therapy","volume":"129","author":"Kielly","year":"2025","journal-title":"Phys. Med."},{"key":"pmbae29debib23","doi-asserted-by":"publisher","first-page":"30","DOI":"10.13182\/NSE98-53","type":"journal-article","article-title":"Measurements of secondary neutrons produced from thick targets bombarded by high-energy helium and carbon ions","volume":"132","author":"Kurosawa","year":"1999","journal-title":"Nucl. Sci. Eng."},{"key":"pmbae29debib24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0168-583X(99)00026-9","type":"journal-article","article-title":"Thick target neutron yields for the 7Li(p,n)7Be reaction near threshold","volume":"152","author":"Lee","year":"1999","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbae29debib25","doi-asserted-by":"publisher","first-page":"S137","DOI":"10.1016\/j.apradiso.2009.03.088","type":"journal-article","article-title":"Neutron spectra measurement and comparison of the HFR and THOR BNCT beams","volume":"67","author":"Liu","year":"2009","journal-title":"Appl. Radiat. Isot."},{"key":"pmbae29debib26","doi-asserted-by":"publisher","first-page":"7623","DOI":"10.1088\/0031-9155\/61\/21\/7623","type":"journal-article","article-title":"Theoretical and experimental characterization of novel water-equivalent plastics in clinical high-energy carbon-ion beams","volume":"61","author":"Louren\u00e7o","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"pmbae29debib27","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1007\/s11060-019-03303-y","type":"journal-article","article-title":"Carbon ion radiotherapy in the treatment of gliomas: a review","volume":"145","author":"Malouff","year":"2019","journal-title":"J. Neuro-Oncol."},{"key":"pmbae29debib28","doi-asserted-by":"publisher","first-page":"4091","DOI":"10.3390\/cancers15164091","type":"journal-article","article-title":"Optimizing boron neutron capture therapy (BNCT) to treat cancer: an updated review on the latest developments on boron compounds and strategies","volume":"15","author":"Monti Hughes","year":"2023","journal-title":"Cancers"},{"key":"pmbae29debib29","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1016\/j.nima.2006.02.027","type":"journal-article","article-title":"Overview of secondary particle production and transport by high-energy heavy ions","volume":"562","author":"Nakamura","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbae29debib30","doi-asserted-by":"publisher","first-page":"Ze01","DOI":"10.7860\/JCDR\/2016\/19890.9024","type":"journal-article","article-title":"Boron neutron capture therapy\u2014a literature review","volume":"10","author":"Nedunchezhian","year":"2016","journal-title":"J. Clin. Diagn. Res."},{"key":"pmbae29debib31","doi-asserted-by":"publisher","first-page":"E57","DOI":"10.1016\/j.ijrobp.2019.06.2392","type":"journal-article","article-title":"Estimated risk for a second malignancy after proton and photon radiation therapy for breast cancer","volume":"105","author":"Paganetti","year":"2019","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbae29debib32","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2022.166767","type":"journal-article","article-title":"Thick target neutron spectral yield and dose measurements with natC (p, n) system at intermediate proton energies between 8\u201320 MeV","volume":"1034","author":"Paul","year":"2022","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbae29debib33","doi-asserted-by":"publisher","first-page":"15","DOI":"10.14338\/IJPT-18-00018.1","type":"journal-article","article-title":"Comparing photon and charged particle therapy using DNA damage biomarkers","volume":"5","author":"Ray","year":"2018","journal-title":"Int. J. Part. Ther."},{"key":"pmbae29debib34","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-34643-w","type":"journal-article","article-title":"Opportunistic dose amplification for proton and carbon ion therapy via capture of internally generated thermal neutrons","volume":"8","author":"Safavi-Naeini","year":"2018","journal-title":"Sci. Rep."},{"key":"pmbae29debib35","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.radmeas.2019.04.016","type":"journal-article","article-title":"Comparison of proton interaction physics models and cross section libraries for proton therapy Monte Carlo simulations by MCNP6.2 code","volume":"125","author":"\u0160olc","year":"2019","journal-title":"Radiat. Meas."},{"key":"pmbae29debib36","doi-asserted-by":"publisher","first-page":"119","DOI":"10.3769\/radioisotopes.29.3_119","type":"journal-article","article-title":"Neutron flux self-shielding in activation analysis","volume":"29","author":"Takeuchi","year":"1980","journal-title":"Radioisotopes"},{"key":"pmbae29debib37","doi-asserted-by":"publisher","first-page":"2111","DOI":"10.1088\/0031-9155\/59\/8\/2111","type":"journal-article","article-title":"Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions","volume":"59","author":"Tessa","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbae29debib38","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.1016\/j.radmeas.2010.07.008","type":"journal-article","article-title":"Characterization of a BNCT beam using neutron activation and indirect neutron radiography","volume":"45","author":"Tsai","year":"2010","journal-title":"Radiat. Meas."},{"key":"pmbae29debib39","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac431b","type":"journal-article","article-title":"Assessment of secondary neutrons in particle therapy by Monte Carlo simulations","volume":"67","author":"Vedelago","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbae29debib40","article-title":"MCNP User\u2019s manual code version 6.2","author":"Werner","year":"2017","type":"other"},{"key":"pmbae29debib41","doi-asserted-by":"publisher","first-page":"S161","DOI":"10.1016\/S0167-8140(04)80041-0","type":"journal-article","article-title":"RBE of carbon ions: experimental data and the strategy of RBE calculation for treatment planning","volume":"73","author":"Weyrather","year":"2004","journal-title":"Radiother. Oncol."},{"key":"pmbae29debib42","doi-asserted-by":"publisher","first-page":"3560","DOI":"10.1002\/cncr.32938","type":"journal-article","article-title":"Second cancer risk after primary cancer treatment with three-dimensional conformal, intensity-modulated, or proton beam radiation therapy","volume":"126","author":"Xiang","year":"2020","journal-title":"Cancer"},{"key":"pmbae29debib43","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0268087","type":"journal-article","article-title":"Commissioning a newly developed treatment planning system, VQA Plan, for fast-raster scanning of carbon-ion beams","volume":"17","author":"Yagi","year":"2022","journal-title":"PLoS One"},{"key":"pmbae29debib44","doi-asserted-by":"publisher","first-page":"4782","DOI":"10.1118\/1.2989019","type":"journal-article","article-title":"Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies","volume":"35","author":"Yonai","year":"2008","journal-title":"Med. Phys."},{"key":"pmbae29debib45","doi-asserted-by":"publisher","first-page":"4830","DOI":"10.1118\/1.3220624","type":"journal-article","article-title":"Monte Carlo study on secondary neutrons in passive carbon-ion radiotherapy: identification of the main source and reduction in the secondary neutron dose","volume":"36","author":"Yonai","year":"2009","journal-title":"Med. Phys."},{"key":"pmbae29debib46","doi-asserted-by":"publisher","first-page":"1369","DOI":"10.1016\/j.radmeas.2010.05.006","type":"journal-article","article-title":"Comparison of measured and calculated in-air secondary neutrons in passive carbon-ion radiotherapy","volume":"45","author":"Yonai","year":"2010","journal-title":"Radiat. Meas."},{"key":"pmbae29debib47","doi-asserted-by":"publisher","DOI":"10.1088\/0031-8949\/87\/01\/015501","type":"journal-article","article-title":"Neutron yields of nuclear reactions induced by ion acceleration in carbon-deuterated plasma produced by ultra-intense lasers","volume":"87","author":"Youssef","year":"2013","journal-title":"Phys. Scr."},{"key":"pmbae29debib48","doi-asserted-by":"publisher","first-page":"3484","DOI":"10.1118\/1.4718685","type":"journal-article","article-title":"Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams","volume":"39","author":"Zheng","year":"2012","journal-title":"Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T13:16:38Z","timestamp":1776950198000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae29de"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,18]]},"references-count":48,"journal-issue":{"issue":"24","published-online":{"date-parts":[[2025,12,18]]},"published-print":{"date-parts":[[2025,12,21]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae29de","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,18]]},"assertion":[{"value":"Experimental study of neutron yield in synchrotron-based carbon ion therapy: implications for neutron capture enhanced particle therapy","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-05-04","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-12-08","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-12-18","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}