{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T09:00:22Z","timestamp":1766998822678,"version":"3.48.0"},"reference-count":41,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T00:00:00Z","timestamp":1766966400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T00:00:00Z","timestamp":1766966400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,1,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    To develop an online quality control (QC) system for accurate assessment of dwell position and dwell time in high-dose-rate (HDR) brachytherapy, and to investigate the potential of neural networks so as to improve the robustness and stability of the proposed system.\n                    <jats:italic>Approach.<\/jats:italic>\n                    An integrated framework was constructed using a Basler high-speed camera (144\u2009fps, 1920\u2009\u00d7\u20091200\u2009pixels), custom illumination, and dedicated software. Experiments were conducted with a GammaMedPlus iX afterloader equipped with a stepping\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mn>192<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                          <mml:mrow>\n                            <mml:mi>Ir<\/mml:mi>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    source, testing various step sizes (0.2\u2009cm, 0.5\u2009cm, 1.0\u2009cm) and dwell times (2.0\u2009s, 3.0\u2009s, 10.0\u2009s). The core online algorithm employed a frame-difference method for source tracking, while offline analysis evaluated the RT-DETRv2 neural network for source localization.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The system achieved high spatial resolution (0.083\u2009mm) and temporal resolution (7.0\u2009ms). Primarily due to guidewire bending, positional deviations remained below 0.1\u2009cm and increased with guidewire length. After position correction, the positional deviation was reduced to about 0.01\u2009cm. Dwell time deviations were within 10.0\u2009ms. RT-DETRv2 demonstrated outstanding localization accuracy (91% of predictions within 0.26\u2009mm) in various conditions. However, its processing latency of 0.35\u2009s per image makes it unsuitable for online monitoring but well-suited for offline or auxiliary verification in this system.\n                    <jats:italic>Significance.<\/jats:italic>\n                    This work presented a technically feasible online QC method for HDR brachytherapy that enabled precise verification of source delivery parameters. Moreover, the successful application of deep learning for source detection established a foundation for future enhancements in reliability and automation of the proposed QC system.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae2aa4","type":"journal-article","created":{"date-parts":[[2025,12,9]],"date-time":"2025-12-09T22:56:53Z","timestamp":1765321013000},"page":"015009","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["New method for online quality control of dwell position and dwell time in brachytherapy by using high-speed camera and neural networks"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-8753-5966","authenticated-orcid":true,"given":"Chang","family":"Cheng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gaolong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dongdong","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhitao","family":"Dai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siwei","family":"Lei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xusheng","family":"Wei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shouping","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhen","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-3703-1642","authenticated-orcid":true,"given":"Xiaoyu","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weiwei","family":"Qu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2025,12,29]]},"reference":[{"key":"pmbae2aa4bib1","doi-asserted-by":"publisher","first-page":"4472","DOI":"10.1118\/1.4923173","type":"journal-article","article-title":"A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas","volume":"42","author":"Awunor","year":"2015","journal-title":"Med. Phys."},{"key":"pmbae2aa4bib2","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1016\/0360-3016(93)90291-3","type":"journal-article","article-title":"The transit dose component of high dose rate brachytherapy: direct measurements and clinical implications","volume":"26","author":"Bastin","year":"1993","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbae2aa4bib3","doi-asserted-by":"publisher","first-page":"628","DOI":"10.3390\/medicina59030628","type":"journal-article","article-title":"Investigation of radiochromic film use for source position verification through a LINAC On-Board Imager (OBI","volume":"59","author":"\u00c7avdar Kara\u00e7am","year":"2023","journal-title":"Medicina"},{"key":"pmbae2aa4bib4","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1080\/17434440.2018.1419058","type":"journal-article","article-title":"Prostate cancer high dose-rate brachytherapy: review of evidence and current perspectives","volume":"15","author":"Dutta","year":"2017","journal-title":"Expert Rev. Med. Devices"},{"key":"pmbae2aa4bib5","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1118\/1.4903286","type":"journal-article","article-title":"HDR 192Ir source speed measurements using a high speed video camera","volume":"42","author":"Fonseca","year":"2015","journal-title":"Med. Phys."},{"key":"pmbae2aa4bib6","doi-asserted-by":"publisher","first-page":"5440","DOI":"10.1088\/1361-6560\/aa7028","type":"journal-article","article-title":"Online pretreatment verification of high-dose rate brachytherapy using an imaging panel","volume":"62","author":"Fonseca","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"pmbae2aa4bib7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.phro.2020.09.002","type":"journal-article","article-title":"In vivo dosimetry in brachytherapy: requirements and future directions for research, development and clinical practice","volume":"16","author":"Fonseca","year":"2020","journal-title":"Phys. Imaging Radiat. Oncol."},{"key":"pmbae2aa4bib8","doi-asserted-by":"publisher","first-page":"1831","DOI":"10.1088\/0031-9155\/59\/7\/1831","type":"journal-article","article-title":"The contribution from transit dose for 192Ir HDR brachytherapy treatments","volume":"59","author":"Fonseca","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbae2aa4bib9","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1093\/bjr\/tqae254","type":"journal-article","article-title":"Partial or focal brachytherapy for prostate cancer: a systematic review and meta-analysis","volume":"98","author":"Guti\u00e9rrez-Valencia","year":"2025","journal-title":"Br. J. Radiol."},{"key":"pmbae2aa4bib10","doi-asserted-by":"publisher","first-page":"9857","DOI":"10.3390\/23249857","type":"journal-article","article-title":"Surface passivation by quantum exclusion: on the quantum efficiency and stability of delta-doped CCDs and CMOS image sensors in space","volume":"23","author":"Hoenk","year":"2023","journal-title":"Sensors"},{"key":"pmbae2aa4bib11","doi-asserted-by":"publisher","first-page":"4581","DOI":"10.1002\/mp.17240","type":"journal-article","article-title":"HDR brachytherapy afterloader quality assurance optimization using monolithic silicon strip detectors","volume":"51","author":"Hunt","year":"2024","journal-title":"Med. Phys."},{"key":"pmbae2aa4bib12","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1016\/j.brachy.2012.01.011","type":"journal-article","article-title":"The dosimetric impact of heterogeneity corrections in high-dose-rate 192Ir brachytherapy for cervical cancer: investigation of both conventional point-a and volume-optimized plans","volume":"11","author":"Hyer","year":"2012","journal-title":"Brachytherapy"},{"key":"pmbae2aa4bib13","doi-asserted-by":"publisher","first-page":"1066","DOI":"10.1016\/j.procs.2022.01.135","type":"journal-article","article-title":"A review of Yolo algorithm developments","volume":"199","author":"Jiang","year":"2022","journal-title":"Procedia Comput. Sci."},{"key":"pmbae2aa4bib14","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1088\/0031-9155\/40\/1\/009","type":"journal-article","article-title":"HDR microSelectron quality-assurance studies using a well-type ion chamber","volume":"40","author":"Jones","year":"1995","journal-title":"Phys. Med. Biol."},{"key":"pmbae2aa4bib15","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-025-02367-2","type":"journal-article","article-title":"Assessment of needle bending and tracking requirements for optimized needle placement in combined intracavitary\/interstitial gynecologic brachytherapy","author":"Karius","year":"2025","journal-title":"Strahlenther. Onkol."},{"key":"pmbae2aa4bib16","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.brachy.2016.09.011","type":"journal-article","article-title":"Differences in outcome for cervical cancer patients treated with or without brachytherapy","volume":"16","author":"Karlsson","year":"2017","journal-title":"Brachytherapy"},{"article-title":"Yolov11: an overview of the key architectural enhancements","year":"2024","author":"Khanam","key":"pmbae2aa4bib17","type":"preprint"},{"key":"pmbae2aa4bib18","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.radonc.2013.11.002","type":"journal-article","article-title":"Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM","volume":"110","author":"Kirisits","year":"2014","journal-title":"Radiother. Oncol."},{"key":"pmbae2aa4bib19","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.4103\/jcrt.jcrt_581_19","type":"journal-article","article-title":"Preliminary clinical efficacy of iodine-125 seed implantation for the treatment of advanced malignant lung tumors","volume":"15","author":"Kou","year":"2019","journal-title":"J. Cancer Res. Ther."},{"key":"pmbae2aa4bib20","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1118\/1.597316","type":"journal-article","article-title":"Comprehensive QA for radiation oncology: report of AAPM radiation therapy committee task group 40","volume":"21","author":"Kutcher","year":"1994","journal-title":"Med. Phys."},{"key":"pmbae2aa4bib21","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac612d","type":"journal-article","article-title":"On the potential of 2D ion chamber arrays for high-dose rate remote afterloading brachytherapy quality assurance","volume":"67","author":"Lekatou","year":"2022","journal-title":"Phys. Med. Biol."},{"article-title":"Decoupled weight decay regularization","year":"2019","author":"Loshchilov","key":"pmbae2aa4bib22","type":"preprint"},{"article-title":"Rt-detrv2: improved baseline with bag-of-freebies for real-time detection transformer","year":"2024","author":"Lv","key":"pmbae2aa4bib23","type":"preprint"},{"key":"pmbae2aa4bib24","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1118\/1.597966","type":"journal-article","article-title":"Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56","volume":"24","author":"Nath","year":"1997","journal-title":"Med. Phys."},{"article-title":"Medical use of byproduct material","year":"2002","author":"NRC-10-CRF-35.6","key":"pmbae2aa4bib25","type":"other"},{"key":"pmbae2aa4bib26","doi-asserted-by":"publisher","first-page":"4804","DOI":"10.1002\/mp.15601","type":"journal-article","article-title":"Technical note: analysis of brachytherapy source movement by high-speed camera","volume":"49","author":"Okamoto","year":"2022","journal-title":"Med. Phys."},{"key":"pmbae2aa4bib27","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1093\/jrr\/rru001","type":"journal-article","article-title":"Dose error from deviation of dwell time and source position for high dose-rate 192Ir in remote afterloading system","volume":"55","author":"Okamoto","year":"2014","journal-title":"J. Radiat. Res."},{"article-title":"nnx runtime","year":"2021","author":"ONNXRuntime","key":"pmbae2aa4bib28","type":"other"},{"key":"pmbae2aa4bib29","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1109\/TPAMI.2016.2577031","type":"journal-article","article-title":"Faster R-CNN: towards real-time object detection with region proposal networks","volume":"39","author":"Ren","year":"2017","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"pmbae2aa4bib30","doi-asserted-by":"publisher","first-page":"2525","DOI":"10.1118\/1.3425786","type":"journal-article","article-title":"A quality assurance tool for high-dose-rate brachytherapy","volume":"37","author":"Rickey","year":"2010","journal-title":"Med. Phys."},{"key":"pmbae2aa4bib31","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1118\/1.1646040","type":"journal-article","article-title":"Update of AAPM task group No. 43 report: a revised AAPM protocol for brachytherapy dose calculations","volume":"31","author":"Rivard","year":"2004","journal-title":"Med. Phys."},{"key":"pmbae2aa4bib32","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/0360-3016(95)02043-8","type":"journal-article","article-title":"The use of radiochromic film to measure dose distributions resulting from high dose rate 192iridium single catheter treatments","volume":"34","author":"Skwarchuk","year":"1996","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbae2aa4bib33","doi-asserted-by":"publisher","DOI":"10.1118\/1.4823758","type":"journal-article","article-title":"Source position verification and dosimetry in HDR brachytherapy using an EPID","volume":"40","author":"Smith","year":"2013","journal-title":"Med. Phys."},{"year":"2018","author":"Steenhuizen","key":"pmbae2aa4bib34","doi-asserted-by":"publisher","DOI":"10.25030\/ncs-030","type":"report"},{"key":"pmbae2aa4bib35","doi-asserted-by":"publisher","first-page":"3698","DOI":"10.1002\/mp.16934","type":"journal-article","article-title":"Multibody dynamic modeling of the behavior of flexible instruments used in cervical cancer brachytherapy","volume":"51","author":"Straathof","year":"2024","journal-title":"Med. Phys."},{"key":"pmbae2aa4bib36","doi-asserted-by":"publisher","first-page":"1612","DOI":"10.1016\/j.clinthera.2020.05.018","type":"journal-article","article-title":"Clinical application of iodine-125 seed brachytherapy combined with anti-pd-1 antibodies in the treatment of lung cancer","volume":"42","author":"Sui","year":"2020","journal-title":"Clin. Ther."},{"key":"pmbae2aa4bib37","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.radonc.2008.06.010","type":"journal-article","article-title":"Consequences of random and systematic reconstruction uncertainties in 3D image based brachytherapy in cervical cancer","volume":"89","author":"Tanderup","year":"2008","journal-title":"Radiother. Oncol."},{"key":"pmbae2aa4bib38","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/j.radonc.2020.09.061","type":"journal-article","article-title":"Accuracy of dwell position detection with a combined electromagnetic tracking brachytherapy system for treatment verification in pelvic brachytherapy","volume":"154","author":"van Heerden","year":"2021","journal-title":"Radiother. Oncol."},{"key":"pmbae2aa4bib39","first-page":"pp 1","type":"book","article-title":"European guidelines for quality assurance in radiotherapy","author":"Venselarr","year":"2004"},{"key":"pmbae2aa4bib40","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1016\/j.brachy.2017.11.015","type":"journal-article","article-title":"Efficacy and safety of iodine-125 radioactive seeds brachytherapy for advanced non-small cell lung cancer-A meta-analysis","volume":"17","author":"Zhang","year":"2017","journal-title":"Brachytherapy"},{"key":"pmbae2aa4bib41","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TPAMI.2024.3382294","type":"journal-article","article-title":"Towards understanding convergence and generalization of AdamW","volume":"46","author":"Zhou","year":"2024","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T08:57:41Z","timestamp":1766998661000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae2aa4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,29]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12,29]]},"published-print":{"date-parts":[[2026,1,14]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae2aa4","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"type":"print","value":"0031-9155"},{"type":"electronic","value":"1361-6560"}],"subject":[],"published":{"date-parts":[[2025,12,29]]},"assertion":[{"value":"New method for online quality control of dwell position and dwell time in brachytherapy by using high-speed camera and neural networks","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2025-08-26","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-12-09","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-12-29","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}