{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T07:42:07Z","timestamp":1776238927420,"version":"3.50.1"},"reference-count":30,"publisher":"IOP Publishing","issue":"8","license":[{"start":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T00:00:00Z","timestamp":1776211200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T00:00:00Z","timestamp":1776211200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Lim Lab Discretionary Funds"},{"DOI":"10.13039\/100007249","name":"University of Minnesota","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100007249","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,4,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . Ultrasound (US) stimulation of the spleen has shown promise in activating anti-inflammatory neural reflexes for treating conditions such as rheumatoid arthritis and sepsis. However, clinical translation remains challenging due to respiratory-induced motion, which risks off-target stimulation and often requires manual adjustment. While US imaging offers key advantages, tracking reliability is reduced by acoustic window loss and occlusion. This study introduces a robust tracking framework that enhances US-based motion monitoring via adaptive sensor fusion.\n                    <jats:italic>Approach<\/jats:italic>\n                    . A wearable accelerometer-based motion tracker was developed to monitor spleen displacement during US imaging. The model was trained and calibrated on short segments of tri-axial accelerometry data to estimate organ motion in the US imaging plane. Performance was evaluated within and across sessions and for different sensor placements. The optimal configuration was integrated into an adaptive tracker that automatically switches between image- and sensor-based estimates using a frame-wise tracking confidence module, ensuring continuous motion monitoring under loss of the acoustic window.\n                    <jats:italic>Main results<\/jats:italic>\n                    . The standalone accelerometer model achieved an average error of 2.0\u2009\u00b1\u20090.8\u2009mm, computed as Euclidean distance to a landmark, across sessions in 27 participants. Under challenging imaging conditions, this model achieved error of 2.3\u2009\u00b1\u20090.6\u2009mm and the adaptive US-accelerometer tracker significantly improved performance, reducing the error to 0.5\u2009\u00b1\u20090.1\u2009mm.\n                    <jats:italic>Significance<\/jats:italic>\n                    . A compact, low-cost, body-mounted accelerometer can enhance US-guided therapies by providing robust and continuous motion estimates. The proposed framework is scalable and generalizable to other abdominal targets, supporting autonomous US-based interventions and enables at-home wearable therapeutic applications.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae5868","type":"journal-article","created":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T22:52:21Z","timestamp":1774651941000},"page":"085001","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Adaptive fusion of accelerometer and ultrasound signals for real-time motion tracking in therapeutic ultrasound stimulation"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-2056-0625","authenticated-orcid":true,"given":"Maryam","family":"Zebarjadi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-8158-2637","authenticated-orcid":true,"given":"Anna J","family":"Organ","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lindsey A","family":"Grafstrom","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9615-3233","authenticated-orcid":true,"given":"Daniel P","family":"Zachs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5653-9679","authenticated-orcid":false,"given":"Hubert H","family":"Lim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2026,4,15]]},"reference":[{"key":"pmbae5868bib1","doi-asserted-by":"publisher","first-page":"3515","DOI":"10.1109\/TUFFC.2021.3095299","type":"journal-article","article-title":"An upgraded siamese neural network for motion tracking in ultrasound image sequences","volume":"68","author":"Bharadwaj","year":"2021","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"pmbae5868bib2","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1109\/TBME.2016.2549272","type":"journal-article","article-title":"Design and validation of a novel MR-compatible sensor for respiratory motion modeling and correction","volume":"64","author":"Chen","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmbae5868bib3","doi-asserted-by":"publisher","first-page":"1647","DOI":"10.1109\/TMI.2013.2262055","type":"journal-article","article-title":"Hybrid feature-based diffeomorphic registration for tumor tracking in 2-D liver ultrasound images","volume":"32","author":"Cifor","year":"2013","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae5868bib4","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1038\/s41551-022-00870-w","type":"journal-article","article-title":"Stimulation of the hepatoportal nerve plexus with focused ultrasound restores glucose homoeostasis in diabetic mice, rats and swine","volume":"6","author":"Cotero","year":"2022","journal-title":"Nat. Biomed. Eng."},{"key":"pmbae5868bib5","doi-asserted-by":"publisher","first-page":"7747","DOI":"10.1002\/mp.15321","type":"journal-article","article-title":"Deep learning-based motion tracking using ultrasound images","volume":"48","author":"Dai","year":"2021","journal-title":"Med. Phys."},{"key":"pmbae5868bib6","doi-asserted-by":"publisher","first-page":"4986","DOI":"10.1002\/mp.13152","type":"journal-article","article-title":"Evaluation of 2D and 3D ultrasound tracking algorithms and impact on ultrasound-guided liver radiotherapy margins","volume":"45","author":"De Luca","year":"2018","journal-title":"Med. Phys."},{"key":"pmbae5868bib7","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1080\/03009742.2020.1764617","type":"journal-article","article-title":"Short-term transcutaneous non-invasive vagus nerve stimulation may reduce disease activity and pro-inflammatory cytokines in rheumatoid arthritis: results of a pilot study","volume":"50","author":"Drewes","year":"2021","journal-title":"Scand. J. Rheumatol."},{"key":"pmbae5868bib8","doi-asserted-by":"publisher","first-page":"3911","DOI":"10.1088\/0031-9155\/58\/11\/3911","type":"journal-article","article-title":"Evaluating and comparing algorithms for respiratory motion prediction","volume":"58","author":"Ernst","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbae5868bib9","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1002\/mrm.22644","type":"journal-article","article-title":"Motion compensated generalized reconstruction for free-breathing dynamic contrast-enhanced MRI","volume":"65","author":"Filipovic","year":"2011","journal-title":"Magn. Reson. Med."},{"key":"pmbae5868bib10","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1016\/j.media.2011.05.018","type":"journal-article","article-title":"Self-encoded marker for optical prospective head motion correction in MRI","volume":"15","author":"Forman","year":"2011","journal-title":"Med. Image Anal."},{"key":"pmbae5868bib11","doi-asserted-by":"publisher","first-page":"525","DOI":"10.3390\/medicina59030525","type":"journal-article","article-title":"Evaluating diagnostic ultrasound of the vagus nerve as a surrogate marker for autonomic neuropathy in diabetic patients","volume":"59","author":"Heiling","year":"2023","journal-title":"Medicina"},{"key":"pmbae5868bib12","doi-asserted-by":"publisher","first-page":"2275","DOI":"10.1002\/mp.13510","type":"journal-article","article-title":"Attention-aware fully convolutional neural network with convolutional long short-term memory network for ultrasound-based motion tracking","volume":"46","author":"Huang","year":"2019","journal-title":"Med. Phys."},{"key":"pmbae5868bib13","doi-asserted-by":"publisher","first-page":"5083","DOI":"10.1038\/s41598-021-84330-6","type":"journal-article","article-title":"Targeted peripheral focused ultrasound stimulation attenuates obesity-induced metabolic and inflammatory dysfunctions","volume":"11","author":"Huerta","year":"2021","journal-title":"Sci. Rep."},{"key":"pmbae5868bib14","doi-asserted-by":"publisher","first-page":"2704","DOI":"10.1109\/TBME.2018.2889669","type":"journal-article","article-title":"A review of low-intensity pulsed ultrasound for therapeutic applications","volume":"66","author":"Jiang","year":"2018","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmbae5868bib15","doi-asserted-by":"publisher","first-page":"3686","DOI":"10.1109\/TMI.2021.3096131","type":"journal-article","article-title":"LAPNet: non-rigid registration derived in k-space for magnetic resonance imaging","volume":"40","author":"K\u00fcstner","year":"2021","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae5868bib16","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2020.101793","type":"journal-article","article-title":"Cascaded one-shot deformable convolutional neural networks: developing a deep learning model for respiratory motion estimation in ultrasound sequences","volume":"65","author":"Liu","year":"2020","journal-title":"Med. Image Anal."},{"key":"pmbae5868bib17","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1109\/42.700739","type":"journal-article","article-title":"Segmentation and tracking in echocardiographic sequences: active contours guided by optical flow estimates","volume":"17","author":"Mikic","year":"1998","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae5868bib18","doi-asserted-by":"publisher","first-page":"ead7206","DOI":"10.1126\/science.adp7206","type":"journal-article","article-title":"Exploiting the mechanical effects of ultrasound for noninvasive therapy","volume":"385","author":"O\u2019Reilly","year":"2024","journal-title":"Science"},{"key":"pmbae5868bib19","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1038\/s41467-019-08750-9","type":"journal-article","article-title":"Noninvasive sub-organ ultrasound stimulation for targeted neuromodulation","volume":"10","author":"Cotero","year":"2019","journal-title":"Nat. Commun."},{"key":"pmbae5868bib20","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1159\/000531469","type":"journal-article","article-title":"Acute inhibition of inflammation mediated by sympathetic nerves: the inflammatory reflex","volume":"30","author":"Occhinegro","year":"2023","journal-title":"Neuroimmunomodulation"},{"key":"pmbae5868bib21","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1109\/TMI.2009.2038908","type":"journal-article","article-title":"Registration of 4D cardiac CT sequences under trajectory constraints with multichannel diffeomorphic demons","volume":"29","author":"Peyrat","year":"2010","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae5868bib22","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1016\/j.ultrasmedbio.2014.08.013","type":"journal-article","article-title":"Near real-time robust non-rigid registration of volumetric ultrasound images for neurosurgery","volume":"41","author":"Rivaz","year":"2015","journal-title":"Ultrasound Med. Biol."},{"key":"pmbae5868bib23","doi-asserted-by":"publisher","first-page":"5889","DOI":"10.1002\/mp.12574","type":"journal-article","article-title":"A block matching based approach with multiple simultaneous templates for the real-time 2D ultrasound tracking of liver vessels","volume":"44","author":"Shepard","year":"2017","journal-title":"Med. Phys."},{"key":"pmbae5868bib24","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1038\/nrcardio.2015.96","type":"journal-article","article-title":"Carotid baroreflex activation therapy for resistant hypertension","volume":"12","author":"Victor","year":"2015","journal-title":"Nat. Rev. Cardiol."},{"key":"pmbae5868bib25","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1038\/s41467-019-08721-0","type":"journal-article","article-title":"Noninvasive ultrasound stimulation of the spleen to treat inflammatory arthritis","volume":"10","author":"Zachs","year":"2019","journal-title":"Nat. Commun."},{"key":"pmbae5868bib26","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/j.brs.2023.04.003","type":"journal-article","article-title":"Focused ultrasound neuromodulation of the spleen activates an anti-inflammatory response in humans","volume":"16","author":"Zanos","year":"2023","journal-title":"Brain Stimul."},{"key":"pmbae5868bib27","doi-asserted-by":"publisher","DOI":"10.1002\/ima.70217","type":"journal-article","article-title":"A review of deep learning for respiratory motion tracking in 2D and 3D ultrasound sequences for image-guided therapy","volume":"35","author":"Zebarjadi","year":"2025","journal-title":"Int. J. Imaging Syst. Technol."},{"key":"pmbae5868bib28","doi-asserted-by":"publisher","first-page":"3484","DOI":"10.1109\/TBME.2025.3570552","type":"journal-article","article-title":"Hybrid KLT-LSTM tracking for robust organ motion monitoring in 2D ultrasound-guided end-organ therapies","volume":"72","author":"Zebarjadi","year":"2025","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmbae5868bib29","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1109\/TMI.2012.2230114","type":"journal-article","article-title":"Elastic image registration versus speckle tracking for 2-D myocardial motion estimation: a direct comparison in vivo","volume":"32","author":"Heyde","year":"2012","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae5868bib30","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa9fc2","type":"journal-article","article-title":"Non-invasive peripheral nerve stimulation via focused ultrasound in vivo","volume":"63","author":"Downs","year":"2018","journal-title":"Phys. Med. Biol."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T06:43:18Z","timestamp":1776235398000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae5868"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,15]]},"references-count":30,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,4,15]]},"published-print":{"date-parts":[[2026,4,28]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae5868","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,15]]},"assertion":[{"value":"Adaptive fusion of accelerometer and ultrasound signals for real-time motion tracking in therapeutic ultrasound stimulation","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-10-25","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-03-27","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-04-15","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}