{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T16:52:10Z","timestamp":1777654330222,"version":"3.51.4"},"reference-count":33,"publisher":"IOP Publishing","issue":"9","license":[{"start":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T00:00:00Z","timestamp":1777420800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T00:00:00Z","timestamp":1777420800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"},{"start":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T00:00:00Z","timestamp":1777420800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T00:00:00Z","timestamp":1777420800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"}],"funder":[{"name":"Varian, a Siemens Healthineers Company"},{"name":"Foundation for Clinical-Experimental Tumor Research"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,5,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Dynamic mixed-beam arc radiotherapy (DYMBARC) combines intensity-modulated electron- and photon-arcs in order to reduce normal tissue dose compared to photon-only techniques while ensuring similar target coverage. For left-sided breast, deep inspiration breath-hold (DIBH) improves heart sparing and mitigates breathing motion. However, dose delivery uncertainties remain due to inter- and intra-breath-hold variations. We assess robustness and dosimetric plan quality of robust optimized (RO)-DYMBARC under DIBH variations with comparison to volumetric modulated arc therapy (VMAT).\n                    <jats:italic>Approach.<\/jats:italic>\n                    Ten cases were created using the extended cardiac-torso anthropomorphic phantom. NiftyReg was used to obtain deformation vector fields (DVFs) for DIBH variations. For each case, three plans were created: planning target volume (PTV)-based VMAT, RO-VMAT, and RO-DYMBARC, prescribed 42.4 Gy to the target volume (PTV or clinical target volume for RO plans). Robustness to DIBH variations was assessed by recalculating doses using the DVFs and deformable voxel geometry Monte Carlo simulations. Dosimetric endpoints for targets and organs at risk (OARs) were compared using Wilcoxon matched-pair signed-rank test (\n                    <jats:italic>\u03b1<\/jats:italic>\n                    = 0.05).\n                    <jats:italic>Main results.<\/jats:italic>\n                    RO-DYMBARC demonstrated significantly better OAR sparing compared to VMAT, with mean dose to heart and contralateral breast up to 1 Gy lower than PTV-based VMAT. Target coverage and robustness to DIBH variations were similar across all plans. For OARs, DIBH variations led to dose differences\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mtext>\u2a7d<\/mml:mtext>\n                          <mml:mrow>\n                            <mml:mtext>\u2009<\/mml:mtext>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    0.1 Gy for all plans and endpoints compared to the nominal scenario.\n                    <jats:italic>Significance.<\/jats:italic>\n                    RO-DYMBARC provided superior dosimetric plan quality with similar robustness to DIBH variations compared to VMAT. The dosimetric advantage of RO-DYMBARC was maintained in the presence of DIBH variations.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae6019","type":"journal-article","created":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T22:57:37Z","timestamp":1776293857000},"page":"095001","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Robust optimized dynamic mixed-beam arc radiotherapy for left-sided breast radiotherapy under deep inspiration breath-hold variations"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-9876-7582","authenticated-orcid":true,"given":"Bj\u00f6rn","family":"Zobrist","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Werner","family":"Volken","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8439-2464","authenticated-orcid":false,"given":"Hannes A","family":"Loebner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-3506-8998","authenticated-orcid":false,"given":"Chengchen","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9835-4362","authenticated-orcid":true,"given":"Silvan","family":"Mueller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3225-8025","authenticated-orcid":false,"given":"Peter","family":"Manser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3911-3403","authenticated-orcid":true,"given":"Michael K","family":"Fix","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0930-1531","authenticated-orcid":true,"given":"Jenny","family":"Bertholet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2026,4,29]]},"reference":[{"key":"pmbae6019bib1","doi-asserted-by":"publisher","first-page":"2976","DOI":"10.1118\/1.2011089","type":"journal-article","article-title":"Energy modulated electron therapy using a few leaf electron collimator in combination with IMRT and 3D-CRT: Monte Carlo-based planning and dosimetric evaluation","volume":"32","author":"Al-Yahya","year":"2005","journal-title":"Med. Phys."},{"key":"pmbae6019bib2","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/j.radonc.2011.05.081","type":"journal-article","article-title":"Comparison of modulated electron radiotherapy to conventional electron boost irradiation and volumetric modulated photon arc therapy for treatment of tumour bed boost in breast cancer","volume":"100","author":"Alexander","year":"2011","journal-title":"Radiother. Oncol."},{"key":"pmbae6019bib3","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2023.109734","type":"journal-article","article-title":"ESTRO-ACROP guideline: recommendations on implementation of breath-hold techniques in radiotherapy","volume":"185","author":"Aznar","year":"2023","journal-title":"Radiother. Oncol."},{"key":"pmbae6019bib4","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad6950","type":"journal-article","article-title":"Robust optimization and assessment of dynamic trajectory and mixed-beam arc radiotherapy: a preliminary study","volume":"69","author":"Bertholet","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbae6019bib5","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1056\/NEJMoa1209825","type":"journal-article","article-title":"Risk of ischemic heart disease in women after radiotherapy for breast cancer","volume":"368","author":"Darby","year":"2025","journal-title":"New Engl. J. Med."},{"key":"pmbae6019bib6","doi-asserted-by":"publisher","first-page":"e819","DOI":"10.1016\/j.clbc.2018.05.010","type":"journal-article","article-title":"A systematic review of heart dose in breast radiotherapy","volume":"18","author":"Drost","year":"2018","journal-title":"Clin. Breast Cancer"},{"key":"pmbae6019bib7","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab8533","type":"journal-article","article-title":"Consistent and invertible deformation vector fields for a breathing anthropomorphic phantom: a post-processing framework for the XCAT phantom","volume":"65","author":"Eiben","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbae6019bib8","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2024.101535","type":"journal-article","article-title":"Intensity modulated therapy for patients with breast cancer. Practical guidelines and tips for an effective treatment planning strategy","volume":"9","author":"Fogliata","year":"2024","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbae6019bib9","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad021a","type":"journal-article","article-title":"Delivery time reduction for mixed photon-electron radiotherapy by using photon MLC collimated electron arcs","volume":"68","author":"Guyer","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbae6019bib10","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.radonc.2020.09.033","type":"journal-article","article-title":"Radiotherapy treatment plannINg study Guidelines (RATING): a framework for setting up and reporting on scientific treatment planning studies","volume":"153","author":"Hansen","year":"2020","journal-title":"Radiother. Oncol."},{"key":"pmbae6019bib11","doi-asserted-by":"publisher","first-page":"7299","DOI":"10.1002\/mp.15258","type":"journal-article","article-title":"Implementation and experimental validation of a robust hybrid direct aperture optimization approach for mixed-beam radiotherapy","volume":"48","author":"Heath","year":"2021","journal-title":"Med. Phys."},{"key":"pmbae6019bib12","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1038\/bjc.2012.575","type":"journal-article","article-title":"Radiation-related mortality from heart disease and lung cancer more than 20 years after radiotherapy for breast cancer","volume":"108","author":"Henson","year":"2013","journal-title":"Br. J. Cancer"},{"key":"pmbae6019bib13","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.tipsro.2021.06.004","type":"journal-article","article-title":"Harmonization of breast cancer radiotherapy treatment planning in the Netherlands","volume":"19","author":"Hurkmans","year":"2021","journal-title":"Tech. Innov. Patient Support Radiat. Oncol."},{"key":"pmbae6019bib14","article-title":"International agency for research on cancer","author":"IARC","year":"2025","type":"web-resource"},{"key":"pmbae6019bib15","first-page":"126","type":"book","article-title":"VMC++, a fast MC algorithm for radiation treatment planning","author":"Iwan","year":"2000"},{"key":"pmbae6019bib16","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1088\/0952-4746\/34\/2\/325","type":"journal-article","article-title":"Radiotherapy-induced secondary cancer risk for breast cancer: 3D conformal therapy versus IMRT versus VMAT","volume":"34","author":"Lee","year":"2014","journal-title":"J. Radiol. Prot."},{"key":"pmbae6019bib17","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/S0167-8140(00)00189-4","type":"journal-article","article-title":"Breast-conserving radiation therapy using combined electron and intensity-modulated radiotherapy technique","volume":"56","author":"Li","year":"2000","journal-title":"Radiother. Oncol."},{"key":"pmbae6019bib18","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.prro.2019.09.017","type":"journal-article","article-title":"Using robust optimization for skin flashing in intensity modulated radiation therapy for breast cancer treatment: a feasibility study","volume":"10","author":"Liang","year":"2020","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbae6019bib19","doi-asserted-by":"publisher","first-page":"6","DOI":"10.7759\/cureus.15649","type":"journal-article","article-title":"Variability of breast surface positioning using an active breathing coordinator for a deep inspiration breath hold technique","volume":"13","author":"McConnell","year":"2021","journal-title":"Cureus"},{"key":"pmbae6019bib20","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.cmpb.2009.09.002","type":"journal-article","article-title":"Fast free-form deformation using graphics processing units","volume":"98","author":"Modat","year":"2010","journal-title":"Comput. Methods Programs Biomed."},{"key":"pmbae6019bib21","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac58db","type":"journal-article","article-title":"A hybrid column generation and simulated annealing algorithm for direct aperture optimization","volume":"67","author":"Mueller","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbae6019bib22","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s11604-009-0336-1","type":"journal-article","article-title":"Cardiac-sparing radiotherapy for the left breast cancer with deep breath-holding","volume":"27","author":"Nemoto","year":"2009","journal-title":"Jpn. J. Radiol."},{"key":"pmbae6019bib23","first-page":"1100","type":"journal-article","article-title":"A generalized concept of equivalent uniform dose (EUD)","volume":"26","author":"Niemierko","year":"1999","journal-title":"Med. Phys."},{"key":"pmbae6019bib24","first-page":"1","type":"other","article-title":"Electron 15.5 reference guide","author":"Photon","year":"2017"},{"key":"pmbae6019bib25","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.radonc.2012.02.008","type":"journal-article","article-title":"Radiation-induced cardiac damage in early left breast cancer patients: risk factors, biological mechanisms, radiobiology, and dosimetric constraints","volume":"103","author":"Sardaro","year":"2012","journal-title":"Radiother. Oncol."},{"key":"pmbae6019bib26","doi-asserted-by":"publisher","first-page":"4902","DOI":"10.1118\/1.3480985","type":"journal-article","article-title":"4DXCAT phantom for multimodality imaging research","volume":"37","author":"Segars","year":"2010","journal-title":"Med. Phys."},{"key":"pmbae6019bib27","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1016\/j.ijrobp.2008.02.040","type":"journal-article","article-title":"Dose to the contralateral breast from radiotherapy and risk of second primary breast cancer in the WECARE study","volume":"72","author":"Stovall","year":"2008","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbae6019bib28","doi-asserted-by":"publisher","first-page":"1641","DOI":"10.1200\/JCO.2016.72.0722","type":"journal-article","article-title":"Estimating the risks of breast cancer radiotherapy: evidence from modern radiation doses to the lungs and heart and from previous randomized trials","volume":"35","author":"Taylor","year":"2017","journal-title":"J. Clin. Oncol."},{"key":"pmbae6019bib29","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1259\/bjr\/70202978","type":"journal-article","article-title":"Margins between clinical target volume and planning target volume for electron beam therapy","volume":"79","author":"Thomas","year":"2006","journal-title":"Br. J. Radiol."},{"key":"pmbae6019bib30","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1053\/j.semradonc.2003.10.003","type":"journal-article","article-title":"Errors and margins in radiotherapy","volume":"14","author":"van Herk","year":"2004","journal-title":"Pract. Radiat. Oncol."},{"key":"pmbae6019bib31","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1118\/1.598932","type":"journal-article","article-title":"Algorithms and functionality of an intensity modulated radiotherapy optimization system","volume":"27","author":"Wu","year":"2000","journal-title":"Med. Phys."},{"key":"pmbae6019bib32","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1002\/mp.17467","type":"journal-article","article-title":"Dosimetric optimization for dynamic mixed beam arc therapy (DYMBARC)","volume":"52","author":"Zhu","year":"2025","journal-title":"Med. Phys."},{"key":"pmbae6019bib33","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1002\/mp.17472","type":"journal-article","article-title":"Monte Carlo dose calculation for photon and electron radiotherapy on dynamically deforming anatomy","volume":"52","author":"Zobrist","year":"2025","journal-title":"Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T06:59:42Z","timestamp":1777445982000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,29]]},"references-count":33,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,4,29]]},"published-print":{"date-parts":[[2026,5,14]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae6019","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,29]]},"assertion":[{"value":"Robust optimized dynamic mixed-beam arc radiotherapy for left-sided breast radiotherapy under deep inspiration breath-hold variations","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-07-30","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-04-14","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-04-29","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}