{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T08:03:30Z","timestamp":1779955410947,"version":"3.53.1"},"reference-count":50,"publisher":"IOP Publishing","issue":"10","license":[{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"},{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,5,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . The 3D CZT SPECT-CT offers better\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>\u03b3<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ray detection, particularly improved energy resolution, which could be useful for more accurately accounting for scattered radiation. These new cameras also benefit from advanced reconstruction methods. Notably, the BSREM algorithm controls noise during the iterative process. This study aims to investigate the influence of using a narrow energy window for scatter correction on image quality and quantification performance. It will also examine the regularisation methods (and their parameters) implemented by the manufacturer.\n                    <jats:italic>Approach<\/jats:italic>\n                    . Acquisitions were performed on two\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mn>99<\/mml:mn>\n                              <mml:mi>m<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                          <mml:mi>T<\/mml:mi>\n                          <mml:mi>c<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    -filled phantoms (a thorax-mimicking phantom including a myocardium insert and a cylindrical tank). Scatter was taken into account using the Jaszczak subtraction method (DEW) and a narrow photopeak window (SEW). The images were reconstructed using the Median Root Prior and Relative Difference Prior regularisation methods. The following were evaluated: sensitivity, sharpness index (a spatial resolution indicator), contrast-to-noise ratio, signal-to-noise ratio, and concentration recovery.\n                    <jats:italic>Main results.<\/jats:italic>\n                    Sensitivity was independent of the regularisation method and was measured at (942.4\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    2.1) and (1074.4\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    12.8) counts.(MBq.s)\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mo>\u2212<\/mml:mo>\n                              <mml:mn>1<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    , respectively, for DEW and SEW. The sharpness index ranged from (0.138\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    0.014) to (0.033\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    0.003) mm\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mo>\u2212<\/mml:mo>\n                              <mml:mn>1<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    , the contrast-to-noise ratio ranged from (4.0\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    0.2) to (2.1\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    0.1), and the signal-to-noise ratio ranged from (11.2\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    0.4) to (4.1\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    0.1). Concentration recovery decreased with the\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>\u03b2<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    parameter for both MRP and RDP, as well as for both scatter corrections.\n                    <jats:italic>Significance<\/jats:italic>\n                    . Using a narrower spectrometric window makes the system more sensitive, providing equivalent image and quantification quality to that achieved using the Jaszczak subtraction method. When the BSREM reconstruction method is used, the quality of the images and the quantification in myocardial SPECT-CT are highly dependent on the regularisation methods and their parameters.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae6e16","type":"journal-article","created":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T22:54:38Z","timestamp":1778799278000},"page":"105020","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Image quality and quantification in\n                    <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                      <mml:mrow>\n                        <mml:msup>\n                          <mml:mi\/>\n                          <mml:mrow>\n                            <mml:mn>99<\/mml:mn>\n                            <mml:mi>m<\/mml:mi>\n                          <\/mml:mrow>\n                        <\/mml:msup>\n                        <mml:mi>T<\/mml:mi>\n                        <mml:mi>c<\/mml:mi>\n                      <\/mml:mrow>\n                    <\/mml:math>\n                    myocardial SPECT-CT with a 3D CZT camera: what to expect from BSREM reconstruction methods?"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7428-4670","authenticated-orcid":true,"given":"Gilles","family":"Le Rouzic","sequence":"first","affiliation":[{"name":"CHU Orl\u00e9ans"},{"name":"LI2RSO, Orleans University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-2631-7968","authenticated-orcid":true,"given":"Micaela","family":"Sacchetti","sequence":"additional","affiliation":[{"name":"CHU Orl\u00e9ans"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6526-0813","authenticated-orcid":false,"given":"Matthieu","family":"Bailly","sequence":"additional","affiliation":[{"name":"CHU Orl\u00e9ans"},{"name":"LI2RSO, Orleans University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"key":"pmbae6e16bib1","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.pcad.2025.09.002","type":"journal-article","article-title":"SPECT myocardial perfusion imaging in the era of PET and multimodality imaging: challenges and opportunities","volume":"93","author":"Alwan","year":"2025","journal-title":"Prog. Cardiovasc. Dis."},{"key":"pmbae6e16bib2","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1007\/s12350-014-0031-1","type":"journal-article","article-title":"Influence of respiratory motion correction on quantification of myocardial perfusion SPECT","volume":"22","author":"Bitarafan-Rajabi","year":"2015","journal-title":"J. Nucl. Cardiol."},{"key":"pmbae6e16bib3","doi-asserted-by":"publisher","first-page":"2263","DOI":"10.1109\/23.531891","type":"journal-article","article-title":"Attenuation correction of SPECT using x-ray CT on an emission-transmission CT system: myocardial perfusion assessment","volume":"43","author":"Blankespoor","year":"1996","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbae6e16bib4","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.3390\/diagnostics14131431","type":"journal-article","article-title":"Technological advances in SPECT and SPECT\/CT imaging","volume":"14","author":"Bouchareb","year":"2024","journal-title":"Diagnostics"},{"key":"pmbae6e16bib5","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1007\/BF00285592","type":"journal-article","article-title":"Scatter correction in scintigraphy: the state of the art","volume":"21","author":"Buvat","year":"1994","journal-title":"Eur. J. Nucl. Med."},{"key":"pmbae6e16bib6","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s40658-019-0264-9","type":"journal-article","article-title":"Noise reduction using a Bayesian penalized-likelihood reconstruction algorithm on a time-of-flight PET-CT scanner","volume":"6","author":"Carib\u00e9","year":"2019","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib7","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1111\/cpf.12853","type":"journal-article","article-title":"First clinical experience of a ring-configured cadmium zinc telluride camera: a comparative study versus conventional gamma camera systems","volume":"44","author":"Ceri\u0107 Andelius","year":"2024","journal-title":"Clin. Physiol. Funct. Imaging"},{"key":"pmbae6e16bib8","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1186\/s40658-023-00586-z","type":"journal-article","article-title":"Quantitative 177Lu SPECT\/CT imaging for personalized dosimetry using a ring-shaped CZT-based camera","volume":"10","author":"Danieli","year":"2023","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib9","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40658-020-0284-5","type":"journal-article","article-title":"Evaluation of a new multipurpose whole-body CzT-based camera: comparison with a dual-head Anger camera and first clinical images","volume":"7","author":"Desmonts","year":"2020","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib10","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1007\/s00259-022-06028-9","type":"journal-article","article-title":"EANM practice guideline for quantitative SPECT-CT","volume":"50","author":"Dickson","year":"2023","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbae6e16bib11","doi-asserted-by":"publisher","first-page":"1784","DOI":"10.1007\/s12350-018-1283-y","type":"journal-article","article-title":"Single photon emission computed tomography (SPECT) myocardial perfusion imaging guidelines: instrumentation, acquisition, processing and interpretation","volume":"25","author":"Dorbala","year":"2018","journal-title":"J. Nucl. Cardiol."},{"key":"pmbae6e16bib12","doi-asserted-by":"publisher","first-page":"50","DOI":"10.2967\/jnmt.124.268252","type":"journal-article","article-title":"Robustness of 18F-FDG PET radiomic features in lung cancer: impact of advanced reconstruction algorithm","volume":"53","author":"Dwivedi","year":"2025","journal-title":"J. Nucl. Med. Technol."},{"key":"pmbae6e16bib13","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1097\/MNM.0000000000001631","type":"journal-article","article-title":"Analysis of image quality by regulating beta function of BSREM reconstruction algorithm and comparison with conventional reconstructions in carcinoma breast studies of PET CT with BGO detector","volume":"44","author":"Dwivedi","year":"2023","journal-title":"Nucl. Med. Commun."},{"key":"pmbae6e16bib14","doi-asserted-by":"publisher","first-page":"R119","DOI":"10.1088\/0031-9155\/57\/21\/R119","type":"journal-article","article-title":"A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology","volume":"57","author":"Erlandsson","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbae6e16bib15","first-page":"2440","type":"journal-article","article-title":"Performance evaluation of a novel multi-detector CZT-based SPECT\/CT system using Tc99m and Lu177","volume":"63","author":"Ferri","year":"2022","journal-title":"J. Nucl. Med."},{"key":"pmbae6e16bib16","doi-asserted-by":"publisher","first-page":"2456","DOI":"10.1007\/s00259-018-4136-7","type":"journal-article","article-title":"EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations","volume":"45","author":"Gear","year":"2018","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbae6e16bib17","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s40658-018-0205-z","type":"journal-article","article-title":"Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results","volume":"5","author":"Goshen","year":"2018","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib18","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1109\/42.52985","type":"journal-article","article-title":"Bayesian reconstructions from emission tomography data using a modified EM algorithm","volume":"9","author":"Green","year":"1990","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae6e16bib19","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1186\/s40658-024-00684-6","type":"journal-article","article-title":"360 \u2218 CZT-SPECT\/CT cameras: 99mTc- and 177Lu-phantom-based evaluation under clinical conditions","volume":"11","author":"Hoog","year":"2024","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib20","doi-asserted-by":"publisher","first-page":"R85","DOI":"10.1088\/0031-9155\/56\/14\/R01","type":"journal-article","article-title":"Review and current status of SPECT scatter correction","volume":"56","author":"Hutton","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"pmbae6e16bib21","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s41824-019-0058-2","type":"journal-article","article-title":"EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras","volume":"3","author":"Cardiovascular Committee of the European Association of Nuclear Medicine (EANM)","year":"2019","journal-title":"Eur. J. Hybrid Imaging"},{"key":"pmbae6e16bib22","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1007\/s12194-025-00887-1","type":"journal-article","article-title":"Impact of a novel respiratory motion reduction block for myocardial perfusion SPECT image quality: a phantom study","volume":"18","author":"Ichikawa","year":"2025","journal-title":"Radiol. Phys. Technol."},{"key":"pmbae6e16bib23","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1016\/j.jmir.2019.05.007","type":"journal-article","article-title":"Impact of resolution recovery in quantitative 99mTc SPECT\/CT cardiac phantom studies","volume":"50","author":"Ismail","year":"2019","journal-title":"J. Med. Imaging Radiat. Sci."},{"key":"pmbae6e16bib24","doi-asserted-by":"publisher","first-page":"1990","DOI":"10.1007\/s00259-019-04404-6","type":"journal-article","article-title":"Two decades of SPECT\/CT \u2013 the coming of age of a technology: an updated review of literature evidence","volume":"46","author":"Israel","year":"2019","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbae6e16bib25","first-page":"893","type":"journal-article","article-title":"Improved SPECT quantification using compensation for scattered photons","volume":"25","author":"Jaszczak","year":"1984","journal-title":"J. Nucl. Med."},{"key":"pmbae6e16bib26","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1002\/mp.14066","type":"journal-article","article-title":"Automated left ventricular myocardium segmentation using 3D deeply supervised attention U-net for coronary computed tomography angiography; CT myocardium segmentation","volume":"47","author":"Jun Guo","year":"2020","journal-title":"Med. Phys."},{"key":"pmbae6e16bib27","doi-asserted-by":"publisher","first-page":"1633","DOI":"10.1007\/s12350-017-0844-9","type":"journal-article","article-title":"Respiratory motion reduction with a dual gating approach in myocardial perfusion SPECT: effect on left ventricular functional parameters","volume":"25","author":"Kortelainen","year":"2018","journal-title":"J. Nucl. Cardiol."},{"key":"pmbae6e16bib28","first-page":"110","type":"journal-article","article-title":"Standard OSEM vs. regularized PET image reconstruction: qualitative and quantitative comparison using phantom data and various clinical radiopharmaceuticals","volume":"8","author":"Lantos","year":"2018","journal-title":"Am. J. Nucl. Med. Mol. Imaging"},{"key":"pmbae6e16bib29","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/s10278-021-00570-y","type":"journal-article","article-title":"BSREM for brain metastasis detection with 18F-FDG-PET\/CT in lung cancer patients","volume":"35","author":"Liberini","year":"2022","journal-title":"J. Digit. Imaging"},{"key":"pmbae6e16bib30","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1007\/s12350-019-01777-x","type":"journal-article","article-title":"MPI in the era of CZT cameras: absolute numbers are still better than relative figures","volume":"28","author":"Liga","year":"2021","journal-title":"J. Nucl. Cardiol."},{"key":"pmbae6e16bib31","first-page":"pp 3955","type":"conference-proceedings","article-title":"Collimator-detector response compensation in quantitative SPECT reconstruction","volume":"vol 5","author":"Liu","year":"2007"},{"key":"pmbae6e16bib32","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s40658-018-0223-x","type":"journal-article","article-title":"Impact of a Bayesian penalized likelihood reconstruction algorithm on image quality in novel digital PET\/CT: clinical implications for the assessment of lung tumors","volume":"5","author":"Messerli","year":"2018","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib33","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s40658-023-00527-w","type":"journal-article","article-title":"Impact of \u03b3 factor in the penalty function of Bayesian penalized likelihood reconstruction (Q.Clear) to achieve high-resolution PET images","volume":"10","author":"Miwa","year":"2023","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib34","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1007\/s12350-019-01702-2","type":"journal-article","article-title":"First comparison of performances between the new whole-body cadmium\u2013zinc\u2013telluride SPECT-CT camera and a dedicated cardiac CZT camera for myocardial perfusion imaging: analysis of phantom and patients","volume":"27","author":"Morelle","year":"2020","journal-title":"J. Nucl. Cardiol."},{"key":"pmbae6e16bib35","first-page":"pp 1783","type":"conference-proceedings","article-title":"Additive and multiplicative versions of the maximum a posteriori algorithm with median root prior","volume":"vol 3","author":"Mustafovic","year":"2002"},{"key":"pmbae6e16bib36","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1109\/TSMC.1979.4310076","type":"journal-article","article-title":"A threshold selection method from gray-level histograms","volume":"9","author":"Otsu","year":"1979","journal-title":"IEEE Trans. Syst. Man Cybern."},{"key":"pmbae6e16bib37","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1118\/1.4937601","type":"journal-article","article-title":"Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: physical phantom experiments","volume":"43","author":"Pourmoghaddas","year":"2016","journal-title":"Med. Phys."},{"key":"pmbae6e16bib38","first-page":"1125","type":"journal-article","article-title":"First performance measurements of a new multi-detector CZT-based SPECT\/CT system: GE StarGuide","volume":"62","author":"Rouzic","year":"2021","journal-title":"J. Nucl. Med."},{"key":"pmbae6e16bib39","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1007\/s13246-023-01299-4","type":"journal-article","article-title":"Phantom and clinical evaluation of Block Sequential Regularized Expectation Maximization (BSREM) reconstruction algorithm in 68Ga-PSMA PET-CT studies","volume":"46","author":"Sadeghi","year":"2023","journal-title":"Phys. Eng. Sci. Med."},{"key":"pmbae6e16bib40","doi-asserted-by":"publisher","first-page":"25","DOI":"10.6009\/jjrt.25-1560","type":"journal-article","article-title":"[Investigation of the optimal parameters for block sequential regularized expectation maximization (BSREM) reconstruction in bone SPECT using a ring-type semiconductor SPECT\/CT]","volume":"81","author":"Sato","year":"2025","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"pmbae6e16bib41","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1186\/s40658-025-00793-w","type":"journal-article","article-title":"A critical phantom study of the energy window used for 99mTc quantitative explorations with a ring CZT SPECT system","volume":"12","author":"Seret","year":"2025a","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib42","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/s40658-025-00754-3","type":"journal-article","article-title":"Quantitative capabilities of commercial CZT SPECT-CT cameras with 99mTc","volume":"12","author":"Seret","year":"2025b","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib43","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1117\/1.1631315","type":"journal-article","article-title":"Survey over image thresholding techniques and quantitative performance evaluation","volume":"13","author":"Sezgin","year":"2004","journal-title":"J. Electron. Imaging"},{"key":"pmbae6e16bib44","doi-asserted-by":"publisher","first-page":"305","DOI":"10.2967\/jnmt.125.269555","type":"journal-article","article-title":"Clinical evaluation of BSREM reconstruction in pediatric oncology using [18F]FDG PET\/CT","volume":"53","author":"Shkumat","year":"2025","journal-title":"J. Nucl. Med. Technol."},{"key":"pmbae6e16bib45","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/s40658-020-00298-8","type":"journal-article","article-title":"Optimization of [ 18F]PSMA-1007 PET-CT using regularized reconstruction in patients with prostate cancer","volume":"7","author":"Tr\u00e4g\u00e5rdh","year":"2020","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib46","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1097\/MNM.0000000000000729","type":"journal-article","article-title":"A clinical evaluation of the impact of the Bayesian penalized likelihood reconstruction algorithm on PET FDG metrics","volume":"38","author":"Vallot","year":"2017","journal-title":"Nucl. Med. Commun."},{"key":"pmbae6e16bib47","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1186\/s40658-021-00393-4","type":"journal-article","article-title":"Experimental validation of absolute SPECT\/CT quantification for response monitoring in patients with coronary artery disease","volume":"8","author":"van de Burgt","year":"2021","journal-title":"EJNMMI Phys."},{"key":"pmbae6e16bib48","doi-asserted-by":"publisher","first-page":"71-77","DOI":"10.2967\/jnmt.125.269869","type":"journal-article","article-title":"Optimization of block sequential regularized expectation maximization reconstruction parameters for striatal SPECT using a ring-type semiconductor SPECT\/CT System","volume":"54","author":"Yamaguchi","year":"2025","journal-title":"J. Nucl. Med. Technol."},{"key":"pmbae6e16bib49","doi-asserted-by":"publisher","first-page":"1340","DOI":"10.1109\/TIP.2014.2300751","type":"journal-article","article-title":"A complete system for automatic extraction of left ventricular myocardium from CT images using shape segmentation and contour evolution","volume":"23","author":"Zhu","year":"2014","journal-title":"IEEE Trans. Image Process."},{"key":"pmbae6e16bib50","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1186\/s40658-024-00671-x","type":"journal-article","article-title":"Performance evaluation of the 3D-ring cadmium-zinc-telluride (CZT) StarGuide system according to the NEMA NU 1-2018 standard","volume":"11","author":"Zorz","year":"2024","journal-title":"EJNMMI Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T07:24:43Z","timestamp":1779953083000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6e16"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":50,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,5,28]]},"published-print":{"date-parts":[[2026,5,28]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae6e16","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]},"assertion":[{"value":"Image quality and quantification in\n                      \n                        \n                          \n                            \n                            \n                              99\n                              m\n                            \n                          \n                          T\n                          c\n                        \n                      \n                      myocardial SPECT-CT with a 3D CZT camera: what to expect from BSREM reconstruction methods?","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-12-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-05-14","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-05-28","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}