{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T19:01:59Z","timestamp":1792177319686,"version":"4.4.0"},"reference-count":23,"publisher":"IOP Publishing","issue":"12","license":[{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,6,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    One factor that impedes the uptake of\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>1<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    maps as quantitative imaging biomarkers in clinical radiotherapy is the large bias and disparity in acquired values across different centers and scanners. In this study, it is shown that the\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>1<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    fitting method results in a large dependence of the acquired\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>1<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    on the applied flip angles. A modification of the signal equation is suggested that reduces this variability. The use of mono-exponential fitting in\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    mapping is responsible for a large bias that is dependent on the echo time spacing in a multi spin echo pulse sequence. A bi-exponential fit provides 3 parametric maps with distinct physiological features and results in more reliable and reproducible\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    maps. QA phantoms that exhibit mono-exponential decay are unable to pick up or assess the impact of non-mono-exponential\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    decay in tissue. Numerical simulations have been applied to determine the optimum range of imaging parameters to minimize the stochastic and systematic uncertainty in\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>1<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>T<\/mml:mi>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    maps.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae6eb3","type":"journal-article","created":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T22:56:50Z","timestamp":1778885810000},"page":"125019","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Protocol optimization for MRI studies in radiation oncology: III. MRI relaxometry"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2626-7622","authenticated-orcid":true,"given":"Yves","family":"De Deene","sequence":"first","affiliation":[{"name":"Cancer Therapy Centre, SWSLHD"},{"name":"Ingham Institute for Applied Medical Research"},{"name":"Western Sydney University"},{"name":"Ghent University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7455-0553","authenticated-orcid":true,"given":"Morgan","family":"Wheatley","sequence":"additional","affiliation":[{"name":"Ingham Institute for Applied Medical Research"},{"name":"Western Sydney University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robba","family":"Rai","sequence":"additional","affiliation":[{"name":"Cancer Therapy Centre, SWSLHD"},{"name":"Ingham Institute for Applied Medical Research"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-9454-7974","authenticated-orcid":true,"given":"David","family":"Walton","sequence":"additional","affiliation":[{"name":"Cancer Therapy Centre, SWSLHD"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doaa","family":"Elwadia","sequence":"additional","affiliation":[{"name":"Cancer Therapy Centre, SWSLHD"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8549-4665","authenticated-orcid":true,"given":"William","family":"S Price","sequence":"additional","affiliation":[{"name":"Western Sydney University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,6,24]]},"reference":[{"key":"pmbae6eb3bib1","doi-asserted-by":"publisher","first-page":"5832","DOI":"10.1007\/s00330-019-06087-x","type":"journal-article","article-title":"Assessment of the extracellular volume fraction for the grading of clear cell carcinoma: first results and histopathological findings","volume":"29","author":"Adams","year":"2019","journal-title":"Eur. Radiol."},{"key":"pmbae6eb3bib2","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/0730-725X(93)90078-R","type":"journal-article","article-title":"Radiofrequency map of an NMR coil by imaging","volume":"11","author":"Akoka","year":"1993","journal-title":"Magn. Reson. Imaging"},{"key":"pmbae6eb3bib3","doi-asserted-by":"publisher","first-page":"1326","DOI":"10.1002\/mrm.20896","type":"journal-article","article-title":"Saturated double-angle method for rapid B1+ mapping","volume":"55","author":"Cunningham","year":"2006","journal-title":"Magn. Reson. Med."},{"key":"pmbae6eb3bib4","doi-asserted-by":"publisher","first-page":"1825","DOI":"10.1088\/0031-9155\/45\/7\/308","type":"journal-article","article-title":"Artefacts in multi-echo T 2 imaging for high-precision gel dosimetry: II. Analysis of B 1-field inhomogeneity","volume":"45","author":"De Deene","year":"2000","journal-title":"Phys. Med. Biol."},{"key":"pmbae6eb3bib5","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/S0165-1684(98)00115-7","type":"journal-article","article-title":"Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry","volume":"70","author":"De Deene","year":"1998","journal-title":"Signal Process."},{"key":"pmbae6eb3bib6","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.1002\/jmri.20758","type":"journal-article","article-title":"Differentiation of hepatocellular carcinoma and hepatic metastasis from cysts and hemangiomas with calculated T2 relaxation times and the T1\/T2 relaxation times ratio","volume":"24","author":"Farraher","year":"2006","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmbae6eb3bib7","doi-asserted-by":"publisher","first-page":"771","DOI":"10.1016\/0730-725X(93)90195-J","type":"journal-article","article-title":"Properties of the phase-alternating phase-shift (PHAPS) multiple spin-echo protocol in MRI: a study of the effects of imperfect RF pulses","volume":"11","author":"Fransson","year":"1993","journal-title":"Magn. Reson. Imaging"},{"key":"pmbae6eb3bib8","doi-asserted-by":"publisher","first-page":"53542","DOI":"10.18632\/oncotarget.18612","type":"journal-article","article-title":"Value of quantitative magnetic resonance imaging T1-relaxometry in predicting contrast-enhancement in glioblastoma","volume":"8","author":"Hattingen","year":"2017","journal-title":"Oncotarget"},{"key":"pmbae6eb3bib9","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1002\/mrm.1910060204","type":"journal-article","article-title":"Magnetic field mapping","volume":"6","author":"Hornak","year":"1988","journal-title":"Magn. Reson. Med."},{"key":"pmbae6eb3bib10","article-title":"Regressions et equations integrales","author":"Jacquelin","year":"2014","type":"other"},{"key":"pmbae6eb3bib11","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0252966","type":"journal-article","article-title":"Multi-site, multi-platform comparison of MRI T 1 measurement using the system phantom","volume":"16","author":"Keenan","year":"2021","journal-title":"PLoS One"},{"key":"pmbae6eb3bib12","doi-asserted-by":"publisher","first-page":"10154","DOI":"10.1002\/mma.7396","type":"journal-article","article-title":"Biexponential fitting for noisy data with error propagation","volume":"44","author":"Lecca","year":"2020","journal-title":"Math. Methods Appl. Sci."},{"key":"pmbae6eb3bib13","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s40644-022-00461-7","type":"journal-article","article-title":"Native T1 mapping for differentiating the histopathological type, grade and stage of rectal adenocarcinoma: a pilot study","volume":"22","author":"Li","year":"2022","journal-title":"Cancer Imaging"},{"key":"pmbae6eb3bib14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111589","type":"journal-article","article-title":"The diagnostic performance of T1 mapping in the assessment of breast lesions: a preliminary study","volume":"177","author":"Lian","year":"2024","journal-title":"Eur. J. Radiol."},{"key":"pmbae6eb3bib15","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1158\/1078-0432.CCR-09-0686","type":"journal-article","article-title":"Quantified tumor T1 is a generic early-response imaging biomarker for chemotherapy reflecting cell viability","volume":"16","author":"McSheehy","year":"2010","journal-title":"Clin. Cancer Res."},{"key":"pmbae6eb3bib16","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1186\/s40644-020-00365-4","type":"journal-article","article-title":"The diagnostic performance of quantitative mapping in breast cancer patients: a preliminary study using synthetic MRI","volume":"20","author":"Meng","year":"2020","journal-title":"Cancer Imaging"},{"key":"pmbae6eb3bib17","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.1010643","type":"journal-article","article-title":"Applications of T1 and T2 relaxation time calculation in tissue differentiation and cancer diagnostics - a systematic literature review","volume":"12","author":"Micek","year":"2022","journal-title":"Front. Oncol."},{"key":"pmbae6eb3bib18","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1007\/s12012-024-09866-1","type":"journal-article","article-title":"Assessment of native myocardial T1 mapping for early detection of anthracycline-induced cardiotoxicity in patients with cancer: a systematic review and meta-analysis","volume":"24","author":"Mohamed","year":"2024","journal-title":"Cardiovasc. Toxicol."},{"key":"pmbae6eb3bib19","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1002\/mrm.22357","type":"journal-article","article-title":"B1 mapping by Bloch-Siegert shift","volume":"63","author":"Sacolick","year":"2010","journal-title":"Magn. Reson. Med."},{"key":"pmbae6eb3bib20","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1186\/1471-2407-14-88","type":"journal-article","article-title":"Tumour T1 changes in vivo are highly predictive of response to chemotherapy and reflect the number of viable tumour cells - a preclinical study in mice","volume":"14","author":"Weidensteiner","year":"2014","journal-title":"BMC Cancer"},{"key":"pmbae6eb3bib21","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1002\/mrm.21120","type":"journal-article","article-title":"Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field","volume":"57","author":"Yarnykh","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"pmbae6eb3bib22","doi-asserted-by":"publisher","first-page":"1328","DOI":"10.1021\/j150556a015","type":"journal-article","article-title":"Nuclear magnetic resonance studies in multiple phase systems: lifetime of a water molecule in an adsorbing phase on silica gel","volume":"61","author":"Zimmerman","year":"1957","journal-title":"J. Phys. Chem."},{"key":"pmbae6eb3bib23","doi-asserted-by":"publisher","first-page":"3424","DOI":"10.1158\/0008-5472.CAN-20-0133","type":"journal-article","article-title":"Noninvasive MRI native T1 mapping detects response to MYCN-targeted therapies in the Th-MYCN model of neuroblastoma","volume":"80","author":"Zormpas-Petridis","year":"2020","journal-title":"Cancer Res."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T15:42:20Z","timestamp":1782315740000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae6eb3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,24]]},"references-count":23,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2026,6,24]]},"published-print":{"date-parts":[[2026,6,28]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae6eb3","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,24]]},"assertion":[{"value":"Protocol optimization for MRI studies in radiation oncology: III. MRI relaxometry","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-09-22","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-05-15","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-24","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}