{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T11:59:32Z","timestamp":1785499172901,"version":"3.56.0"},"reference-count":49,"publisher":"IOP Publishing","issue":"12","license":[{"start":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T00:00:00Z","timestamp":1782345600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T00:00:00Z","timestamp":1782345600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T00:00:00Z","timestamp":1782345600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T00:00:00Z","timestamp":1782345600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,6,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    To develop and illustrate the potential of a new, flexible, open-source software engine for task-based optimisation of exposure parameter settings in x-ray projection imaging.\n                    <jats:italic>Approach.<\/jats:italic>\n                    The engine was built from several Python-scripted modules to automate exposure parameter optimization. Input is taken from a set of pre-calculated tables containing image quality and dose data, and system parameters defined by the user. Modular code is employed, with classes responsible for image quality and dose calculations. For this study, the image quality (IQ) module incorporated the standard signal-to-noise ratio (\n                    <jats:italic>SNR<\/jats:italic>\n                    ) and a version of\n                    <jats:italic>SNR<\/jats:italic>\n                    (\n                    <jats:italic>\n                      SNR\n                      <jats:inline-formula>\n                        <jats:tex-math>\n                          \n                        <\/jats:tex-math>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mrow\/>\n                              <mml:mrow>\n                                <mml:mi>w<\/mml:mi>\n                              <\/mml:mrow>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:inline-formula>\n                    <\/jats:italic>\n                    ) that is weighted for the influence of the x-ray focus size and finite x-ray pulse width on the task. Optimal x-ray factors for a specified task are established by the Optimizer class that maximizes a figure-of-merit defined as\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow>\n                              <mml:mi mathvariant=\"italic\">SNR<\/mml:mi>\n                            <\/mml:mrow>\n                            <mml:mrow>\n                              <mml:mn>2<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    or\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msubsup>\n                            <mml:mrow>\n                              <mml:mi mathvariant=\"italic\">SNR<\/mml:mi>\n                            <\/mml:mrow>\n                            <mml:mi>w<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mn>2<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msubsup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    divided by dose. A set of six experiments with different degrees of complexity was performed to illustrate the engine and the influence of x-ray factor selection for a cardiac imaging task.\n                    <jats:italic>Main results<\/jats:italic>\n                    . A full parameter search covering 2400 different combinations of tube potential, additional copper filtration and focal spot size for 11 distinct patient thicknesses took approximately 30 min. The six experiments demonstrated that it is essential to consider x-ray tube power limitations and, when applicable, object motion and dose limits when determining the optimal exposure parameters.\n                    <jats:italic>Significance<\/jats:italic>\n                    . The proposed engine automates optimal exposure parameter selection for user-defined image quality metrics and dose estimates. The influence of x-ray system parameters on system performance can be explored systematically. The engine is provided as an open-source resource with a modular structure that can be extended to include different figures of merit, and different image quality and dose metrics. The repository containing the engine is available at\n                    <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/gitlab.kuleuven.be\/medphysqa\/deploy\/flexpose\/flexpose\">https:\/\/gitlab.kuleuven.be\/medphysqa\/deploy\/flexpose\/flexpose<\/jats:ext-link>\n                    .\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae788e","type":"journal-article","created":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T09:26:01Z","timestamp":1780651561000},"page":"125031","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["flEXPOSE: a flexible exposure parameter optimisation engine for x-ray projection imaging"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9078-080X","authenticated-orcid":true,"given":"Rodrigo T","family":"Massera","sequence":"first","affiliation":[{"name":"KU Leuven"},{"name":"KU Leuven"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5549-5133","authenticated-orcid":true,"given":"Nicholas W","family":"Marshall","sequence":"additional","affiliation":[{"name":"KU Leuven"},{"name":"UZ Gasthuisberg"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hilde","family":"Bosmans","sequence":"additional","affiliation":[{"name":"KU Leuven"},{"name":"UZ Gasthuisberg"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,6,25]]},"reference":[{"key":"pmbae788ebib1","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.1109\/TMI.2018.2886530","type":"journal-article","article-title":"DukeSim: a realistic, rapid and scanner-specific simulation framework in computed tomography","volume":"38","author":"Abadi","year":"2019","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae788ebib2","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.7.4.042805","type":"journal-article","article-title":"Virtual clinical trials in medical imaging: a review","volume":"7","author":"Abadi","year":"2020","journal-title":"J. Med. Imaging"},{"key":"pmbae788ebib3","author":"Aichinger","year":"2012","edition":"2nd edn","type":"book"},{"key":"pmbae788ebib4","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1109\/TNS.2006.869826","type":"journal-article","article-title":"Geant4 developments and applications","volume":"53","author":"Allison","year":"2006","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbae788ebib5","doi-asserted-by":"publisher","DOI":"10.1001\/jamanetworkopen.2018.5474","type":"journal-article","article-title":"Evaluation of digital breast tomosynthesis as replacement of full-field digital mammography using an in silico imaging trial","volume":"1","author":"Badano","year":"2018","journal-title":"JAMA Netw. Open"},{"key":"pmbae788ebib6","doi-asserted-by":"publisher","first-page":"1545","DOI":"10.1088\/0031-9155\/51\/6\/013","type":"journal-article","article-title":"MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems","volume":"51","author":"Badano","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib7","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1117\/12.593884","type":"journal-article","article-title":"Spatial frequency-dependent signal-to-noise ratio as a generalized measure of image quality","volume":"5745","author":"Bernhardt","year":"2005","journal-title":"Med. Imaging 2005: Phys. Med. Imaging"},{"key":"pmbae788ebib8","doi-asserted-by":"publisher","first-page":"4337","DOI":"10.1118\/1.2351951","type":"journal-article","article-title":"X-ray spectrum optimization of full-field digital mammography: Simulation and phantom study","volume":"33","author":"Bernhardt","year":"2006","journal-title":"Med. Phys."},{"key":"pmbae788ebib9","doi-asserted-by":"publisher","first-page":"3749","DOI":"10.1088\/0031-9155\/56\/13\/002","type":"journal-article","article-title":"Standing adult human phantoms based on 10th, 50th and 90th mass and height percentiles of male and female caucasian populations","volume":"56","author":"Cassola","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib10","doi-asserted-by":"publisher","first-page":"1919","DOI":"10.1088\/0031-9155\/57\/7\/1919","type":"journal-article","article-title":"Optimization of x-ray spectra in digital mammography through Monte Carlo simulations","volume":"57","author":"Cunha","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib11","doi-asserted-by":"publisher","first-page":"1056","DOI":"10.1259\/bjr.73.874.11271898","type":"journal-article","article-title":"Influence of anode\/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study","volume":"73","author":"Dance","year":"2000","journal-title":"Br. J. Radiol."},{"key":"pmbae788ebib12","doi-asserted-by":"publisher","first-page":"6610","DOI":"10.1088\/1361-6560\/aa7a9d","type":"journal-article","article-title":"Evaluation of automatic dose rate control for flat panel imaging using a spatial frequency domain figure of merit","volume":"62","author":"Dehairs","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib13","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aafd5c","type":"journal-article","article-title":"Implementation of a spatio-temporal figure of merit for new automatic dose rate control regimes in dynamic x-ray imaging","volume":"64","author":"Dehairs","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib14","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abbb7a","type":"journal-article","article-title":"A study of the impact of x-ray tube performance on angiography system imaging efficiency","volume":"65","author":"Dehairs","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib15","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1118\/1.594198","type":"journal-article","article-title":"X-ray images of small blood vessels in angiography: question of isoplanatism","volume":"2","author":"Doi","year":"1975","journal-title":"Med. Phys."},{"key":"pmbae788ebib16","doi-asserted-by":"publisher","first-page":"2953","DOI":"10.1088\/0031-9155\/51\/11\/018","type":"journal-article","article-title":"Application of contrast-to-noise ratio in optimizing beam quality for digital chest radiography: comparison of experimental measurements and theoretical simulations","volume":"51","author":"Doyle","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib17","first-page":"pp 593","type":"book","article-title":"A practical guide to model observers for visual detection in synthetic and natural noisy images","author":"Eckstein","year":"2000"},{"key":"pmbae788ebib18","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1118\/1.597406","type":"journal-article","article-title":"A model for optimization of spectral shape in digital mammography","volume":"21","author":"Fahrig","year":"1994","journal-title":"Med. Phys."},{"key":"pmbae788ebib19","doi-asserted-by":"publisher","DOI":"10.1118\/1.4818016","type":"journal-article","article-title":"Dose optimization in cardiac x-ray imaging","volume":"40","author":"Gislason-Lee","year":"2013","journal-title":"Med. Phys."},{"key":"pmbae788ebib20","article-title":"Medical Imaging\u2013the Assessment of Image Quality","author":"ICRU n. d.","type":"other"},{"key":"pmbae788ebib21","doi-asserted-by":"publisher","DOI":"10.1118\/1.4835495","type":"journal-article","article-title":"Medical imaging using ionizing radiation: Optimization of dose and image quality in fluoroscopy","volume":"41","author":"Jones","year":"2014","journal-title":"Med. Phys."},{"key":"pmbae788ebib22","article-title":"Egsnrc toolkit for monte carlo simulation of ionizing radiation transport","author":"Kawrakow","year":"2000","type":"other"},{"key":"pmbae788ebib23","first-page":"pp 445","type":"conference-proceedings","article-title":"Overall x-ray system simulation model developed for system design and image quality versus patient dose optimization","author":"Kroon","year":"2003"},{"key":"pmbae788ebib24","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad2b93","type":"journal-article","article-title":"A combined analytical and Monte Carlo method for detailed simulations of antiscatter grids in x-ray medical imaging: implementing scatter within the grid","volume":"69","author":"Massera","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib25","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad56f3","type":"journal-article","article-title":"A comprehensive assessment of a prototype high ratio antiscatter grid in interventional cardiology using experimental measurements and Monte Carlo simulations","volume":"69","author":"Massera","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib26","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1259\/bjr\/52734084","type":"journal-article","article-title":"A study and optimization of lumbar spine x-ray imaging systems","volume":"76","author":"McVey","year":"2003","journal-title":"Br. J. Radiol."},{"key":"pmbae788ebib27","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2022.110396","type":"journal-article","article-title":"Optimization of image quality and dose in adult and pediatric chest radiography via Monte Carlo simulation and experimental methods","volume":"201","author":"Mendes","year":"2022","journal-title":"Radiat. Phys. Chem."},{"key":"pmbae788ebib28","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.11.4.045502","type":"journal-article","article-title":"Comparison of human observer impression of x-ray fluoroscopy and angiography image quality with technical changes to image quality","volume":"11","author":"Mihailovic","year":"2024","journal-title":"J. Med. Imaging"},{"key":"pmbae788ebib29","doi-asserted-by":"publisher","first-page":"3630","DOI":"10.1002\/mp.14945","type":"journal-article","article-title":"Technical Note: SpekPy v2.0\u2014a software toolkit for modeling x-ray tube spectra","volume":"48","author":"Poludniowski","year":"2021","journal-title":"Med. Phys."},{"key":"pmbae788ebib30","doi-asserted-by":"publisher","first-page":"2826","DOI":"10.1118\/1.4704524","type":"journal-article","article-title":"Functionality and operation of fluoroscopic automatic brightness control\/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography\/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council","volume":"39","author":"Rauch","year":"2012","journal-title":"Med. Phys."},{"key":"pmbae788ebib31","doi-asserted-by":"publisher","author":"Salvat","year":"2019","DOI":"10.1787\/32da5043-en","type":"book"},{"key":"pmbae788ebib32","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1093\/rpd\/nch562","type":"journal-article","article-title":"A framework for optimising the radiographic technique in digital x-ray imaging","volume":"114","author":"Samei","year":"2005","journal-title":"Radiat. Prot. Dosim."},{"key":"pmbae788ebib33","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1088\/0031-9155\/37\/6\/004","type":"journal-article","article-title":"Influence of x-ray energy spectrum, contrasting detail and detector on the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) in projection radiography","volume":"37","author":"Sandborg","year":"1992","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib34","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/0169-2607(94)90127-9","type":"journal-article","article-title":"A Monte Carlo program for the calculation of contrast, noise and absorbed dose in diagnostic radiology","volume":"42","author":"Sandborg","year":"1994","journal-title":"Comput. Methods Programs Biomed."},{"key":"pmbae788ebib35","doi-asserted-by":"publisher","first-page":"2007","DOI":"10.1118\/1.1405840","type":"journal-article","article-title":"Schemes for the optimization of chest radiography using a computer model of the patient and x-ray imaging system","volume":"28","author":"Sandborg","year":"2001","journal-title":"Med. Phys."},{"key":"pmbae788ebib36","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1002\/mp.12702","type":"journal-article","article-title":"RECORDS: improved Reporting of montE CarlO RaDiation transport Studies: Report of the AAPM Research Committee Task Group 268","volume":"45","author":"Sechopoulos","year":"2018","journal-title":"Med. Phys."},{"key":"pmbae788ebib37","doi-asserted-by":"publisher","DOI":"10.1118\/1.4794178","type":"journal-article","article-title":"Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization","volume":"40","author":"Segars","year":"2013","journal-title":"Med. Phys."},{"key":"pmbae788ebib38","doi-asserted-by":"publisher","first-page":"5887","DOI":"10.1118\/1.3643029","type":"journal-article","article-title":"A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries\u2014application to far-from-axis fields","volume":"38","author":"Sempau","year":"2011","journal-title":"Med. Phys."},{"key":"pmbae788ebib39","doi-asserted-by":"publisher","first-page":"1903","DOI":"10.1118\/1.1286590","type":"journal-article","article-title":"Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)","volume":"27","author":"Siewerdsen","year":"2000","journal-title":"Med. Phys."},{"key":"pmbae788ebib40","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1093\/rpd\/ncq061","type":"journal-article","article-title":"Cu filtration for dose reduction in neonatal chest imaging","volume":"139","author":"Smans","year":"2010","journal-title":"Radiat. Prot. Dosim."},{"key":"pmbae788ebib41","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab39c4","type":"journal-article","article-title":"Integration of high velocity test object motion into a channelized Hotelling observer for the assessment of x-ray angiography systems","volume":"64","author":"Tao","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib42","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1088\/0031-9155\/40\/4\/007","type":"journal-article","article-title":"Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculations","volume":"40","author":"Tapiovaara","year":"1995","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib43","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1088\/0031-9155\/44\/2\/018","type":"journal-article","article-title":"A search for improved technique factors in paediatric fluoroscopy","volume":"44","author":"Tapiovaara","year":"1999","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib44","doi-asserted-by":"publisher","first-page":"2081","DOI":"10.1002\/mp.16679","type":"journal-article","article-title":"Development, validation and simplification of a scanner-specific CT simulator","volume":"51","author":"Tunissen","year":"2024","journal-title":"Med. Phys."},{"key":"pmbae788ebib45","doi-asserted-by":"publisher","first-page":"7641","DOI":"10.1002\/mp.15288","type":"journal-article","article-title":"Comparison of a contrast-to-noise ratio-driven exposure control and a regular detector dose-driven exposure control in abdominal imaging in a clinical angiography system","volume":"48","author":"Werncke","year":"2021a","journal-title":"Med. Phys."},{"key":"pmbae788ebib46","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abe83a","type":"journal-article","article-title":"Impact of a contrast-to-noise ratio driven and material specific exposure control on image quality and radiation exposure in angiography","volume":"66","author":"Werncke","year":"2021b","journal-title":"Phys. Med. Biol."},{"key":"pmbae788ebib47","doi-asserted-by":"publisher","first-page":"2414","DOI":"10.1118\/1.2912177","type":"journal-article","article-title":"Optimization of exposure parameters in full field digital mammography","volume":"35","author":"Williams","year":"2008","journal-title":"Med. Phys."},{"key":"pmbae788ebib48","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1364\/JOSAA.15.000375","type":"journal-article","article-title":"Detection of moving objects in pulsed-x-ray fluoroscopy","volume":"15","author":"Xue","year":"1998","journal-title":"J. Opt. Soc. Am. A"},{"key":"pmbae788ebib49","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1118\/1.595130","type":"journal-article","article-title":"The optimization of signal detectability in digital fluoroscopy","volume":"9","author":"Zamenhof","year":"1982","journal-title":"Med. Phys."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T11:25:18Z","timestamp":1785497118000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae788e"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,25]]},"references-count":49,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2026,6,25]]},"published-print":{"date-parts":[[2026,6,28]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae788e","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,25]]},"assertion":[{"value":"flEXPOSE: a flexible exposure parameter optimisation engine for x-ray projection imaging","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-02-09","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-04","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-25","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}