{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T17:46:33Z","timestamp":1790444793582,"version":"4.1.0"},"reference-count":21,"publisher":"IOP Publishing","issue":"12","license":[{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"PIANOFORTE","award":["101061037"],"award-info":[{"award-number":["101061037"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,6,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    This study aims to establish a standardized workflow for developing highly realistic, anatomically, and dosimetrically equivalent three-dimensional printing (3DP) phantoms for adaptive and patient-specific radiotherapy. Despite recent advances in 3DP technology, the lack of standardization in phantom development limits reproducibility and comparability across studies.\n                    <jats:italic>Approach.<\/jats:italic>\n                    A systematic standardized workflow was designed comprising material characterization, calibration, and phantom fabrication. Various 3DP materials were printed and characterized for relative electron density (RED) and effective atomic number (\n                    <jats:italic>Z<\/jats:italic>\n                    <jats:sub>eff<\/jats:sub>\n                    ) using dual-energy computed tomography (CT). The measured properties were compared to ICRU44 human tissue reference values to identify suitable materials for each tissue of interest. A calibration matrix (CM), specific to each filament and 3D printer, was developed by varying infill density and volumetric flow rate to optimize printing parameters for each tissue. Using this workflow, an anthropomorphic head phantom and two thorax phantoms (one multi-material and one dual-material) were modelled from a digital-, synthetic CT scan and manufactured.\n                    <jats:italic>Main result.<\/jats:italic>\n                    The head phantom verification scan showed a maximum mean deviation of 6.04% in RED and 3.00% in\n                    <jats:italic>Z<\/jats:italic>\n                    <jats:sub>eff<\/jats:sub>\n                    relative to CM-optimized values. The multi-material thorax phantom exhibited higher deviations of 8.27% in RED and 12.6% in\n                    <jats:italic>Z<\/jats:italic>\n                    <jats:sub>eff<\/jats:sub>\n                    , while the dual-material thorax phantom showed smaller differences of 2.14% and 10.3% in RED and\n                    <jats:italic>Z<\/jats:italic>\n                    <jats:sub>eff<\/jats:sub>\n                    , respectively.\n                    <jats:italic>Significance.<\/jats:italic>\n                    The proposed standardized workflow provides a first quantitative and reproducible approach that incorporates reference tissue properties, inter-printer variability, and filament without increasing workload. It offers a practical foundation for producing anatomically and compositionally accurate 3DP phantoms, supporting broader clinical implementation and improving patient-specific radiotherapy outcomes.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae794c","type":"journal-article","created":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T22:55:58Z","timestamp":1780700158000},"page":"125024","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["A standardized workflow for the development and manufacturing of tissue-equivalent anthropomorphic phantoms for radiotherapy using 3D-printing"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-7971-7753","authenticated-orcid":true,"given":"Tim H A","family":"Stassen","sequence":"first","affiliation":[{"name":"Maastricht University Medical Centre+"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3067-5645","authenticated-orcid":true,"given":"Didier","family":"Lustermans","sequence":"additional","affiliation":[{"name":"Maastricht University Medical Centre+"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-3521-6521","authenticated-orcid":true,"given":"Lars H B A","family":"Daenen","sequence":"additional","affiliation":[{"name":"Maastricht University Medical Centre+"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1243-9796","authenticated-orcid":false,"given":"Luana","family":"de Freitas Nascimento","sequence":"additional","affiliation":[{"name":"(SCK CEN)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8470-386X","authenticated-orcid":true,"given":"Frank","family":"Verhaegen","sequence":"additional","affiliation":[{"name":"Maastricht University Medical Centre+"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8087-1193","authenticated-orcid":false,"given":"Gabriel","family":"Paiva Fonseca","sequence":"additional","affiliation":[{"name":"Maastricht University Medical Centre+"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,6,24]]},"reference":[{"key":"pmbae794cbib1","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1148\/radiol.10090908","type":"journal-article","article-title":"Intravenous contrast medium administration and scan timing at CT: considerations and approaches","volume":"256","author":"Bae","year":"2010","journal-title":"Radiology"},{"key":"pmbae794cbib2","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ad6f13","type":"journal-article","article-title":"3D printed heterogeneous paediatric head and adult thorax phantoms for linear accelerator radiotherapy quality assurance: from fabrication to treatment delivery","volume":"10","author":"Bustillo","year":"2024","journal-title":"Biomed. Phys. Eng. Express"},{"key":"pmbae794cbib3","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1002\/acm2.12162","type":"journal-article","article-title":"Preparation and fabrication of a full\u2010scale, sagittal\u2010sliced, 3D\u2010printed, patient\u2010specific radiotherapy phantom","volume":"18","author":"Craft","year":"2017","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbae794cbib4","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.ejmp.2017.05.051","type":"journal-article","article-title":"Radiological properties of 3D printed materials in kilovoltage and megavoltage photon beams","volume":"38","author":"Dancewicz","year":"2017","journal-title":"Phys. Med."},{"key":"pmbae794cbib5","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1016\/j.brachy.2023.02.002","type":"journal-article","article-title":"3D printing in brachytherapy: a systematic review of gynecological applications","volume":"22","author":"Fahimian","year":"2023","journal-title":"Brachytherapy"},{"key":"pmbae794cbib6","doi-asserted-by":"publisher","first-page":"3583","DOI":"10.1002\/mp.14937","type":"journal-article","article-title":"Evaluation of novel AI\u2010based extended field\u2010of\u2010view CT reconstructions","volume":"48","author":"Fonseca","year":"2021","journal-title":"Med. Phys."},{"key":"pmbae794cbib7","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acaf4a","type":"journal-article","article-title":"Dual-energy CT evaluation of 3D printed materials for radiotherapy applications","volume":"68","author":"Fonseca","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbae794cbib8","author":"Goldstein","year":"2017","type":"book"},{"key":"pmbae794cbib9","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1016\/j.zemedi.2022.02.001","type":"journal-article","article-title":"3D printed patient-specific thorax phantom with realistic heterogenous bone radiopacity using filament printer technology","volume":"32","author":"Hatamikia","year":"2022","journal-title":"Z. Med. Phys."},{"key":"pmbae794cbib10","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1088\/0031-9155\/59\/1\/83","type":"journal-article","article-title":"Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates","volume":"59","author":"H\u00fcnemohr","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbae794cbib11","first-page":"277","type":"book","article-title":"3D Slicer: a platform for subject-specific image analysis, visualization, and clinical support","author":"Kikinis","year":"2013"},{"key":"pmbae794cbib12","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2025.113719","type":"journal-article","article-title":"Design and additive manufacture of patient-specific head phantom for radiotherapy","volume":"252","author":"Lin","year":"2025","journal-title":"Mater. Des."},{"key":"pmbae794cbib13","doi-asserted-by":"publisher","DOI":"10.1016\/j.phro.2024.100656","type":"journal-article","article-title":"Development of a novel 3D-printed dynamic anthropomorphic thorax phantom for evaluation of four-dimensional computed tomography","volume":"32","author":"Lustermans","year":"2024","journal-title":"Phys. Imaging Radiat. Oncol."},{"key":"pmbae794cbib14","doi-asserted-by":"publisher","first-page":"820","DOI":"10.2174\/1573405617666210202114336","type":"journal-article","article-title":"Evaluating 3D-printed bolus compared to conventional bolus types used in external beam radiation therapy","volume":"17","author":"McCallum","year":"2021","journal-title":"Curr. Med. Imaging"},{"key":"pmbae794cbib15","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1002\/mp.15407","type":"journal-article","article-title":"Three\u2010dimensional printing of patient\u2010specific lung phantoms for CT imaging: emulating lung tissue with accurate attenuation profiles and textures","volume":"49","author":"Mei","year":"2022","journal-title":"Med. Phys."},{"key":"pmbae794cbib16","doi-asserted-by":"publisher","first-page":"2206","DOI":"10.1002\/mp.14100","type":"journal-article","article-title":"Accurate replication of soft and bone tissues with 3D printing","volume":"47","author":"Okkalidis","year":"2020","journal-title":"Med. Phys."},{"key":"pmbae794cbib17","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1002\/9780470721582.ch3","type":"journal-article","article-title":"Electron spectroscopy for chemical analysis","author":"Ratner","year":"2009","journal-title":"Surf. Anal. Prin. Tech."},{"key":"pmbae794cbib18","doi-asserted-by":"publisher","first-page":"4902","DOI":"10.1118\/1.3480985","type":"journal-article","article-title":"4D XCAT phantom for multimodality imaging research","volume":"37","author":"Segars","year":"2010","journal-title":"Med. Phys."},{"key":"pmbae794cbib19","doi-asserted-by":"publisher","DOI":"10.1177\/1533033819870208","type":"journal-article","article-title":"A systematic review on 3D-Printed imaging and dosimetry phantoms in radiation therapy","volume":"18","author":"Tino","year":"2019","journal-title":"Technol. Cancer Res. Treat."},{"key":"pmbae794cbib20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultramic.2024.113935","type":"journal-article","article-title":"Energy-dispersive x-ray spectroscopy in a low energy electron microscope","volume":"259","author":"Tromp","year":"2024","journal-title":"Ultramicroscopy"},{"key":"pmbae794cbib21","doi-asserted-by":"publisher","first-page":"1209","DOI":"10.1259\/0007-1285-59-708-1209","type":"journal-article","article-title":"The composition of body tissues","volume":"59","author":"Woodard","year":"1986","journal-title":"Br. J. Radiol."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T11:16:28Z","timestamp":1782299788000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,24]]},"references-count":21,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2026,6,24]]},"published-print":{"date-parts":[[2026,6,28]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae794c","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,24]]},"assertion":[{"value":"A standardized workflow for the development and manufacturing of tissue-equivalent anthropomorphic phantoms for radiotherapy using 3D-printing","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-12-20","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-05","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-24","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}