{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T10:49:23Z","timestamp":1782989363832,"version":"3.54.5"},"reference-count":35,"publisher":"IOP Publishing","issue":"13","license":[{"start":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T00:00:00Z","timestamp":1782950400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T00:00:00Z","timestamp":1782950400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"},{"start":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T00:00:00Z","timestamp":1782950400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T00:00:00Z","timestamp":1782950400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"}],"funder":[{"name":"Taishan Industrial Experts Program"},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["82227802"],"award-info":[{"award-number":["82227802"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100012166","name":"National Key R&D Program of China","doi-asserted-by":"crossref","award":["2025YFC2426200"],"award-info":[{"award-number":["2025YFC2426200"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,7,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Magnetic particle imaging (MPI) enables real-time, radiation-free tracking of magnetic nanoparticle\u2013coated instruments, making it highly suitable for interventional procedures. This study proposes a harmonic-aware transformer framework that directly predicts catheter tip positions from raw MPI voltage signals, eliminating the need for image reconstruction and reducing computational latency.\n                    <jats:italic>Approach.<\/jats:italic>\n                    The framework incorporates frequency-domain preprocessing to isolate the 2nd\u20138th drive-field harmonics, enhancing the signal-to-noise ratio while preserving motion-relevant features. A transformer architecture with six encoder layers and eight attention heads is employed to learn spatio-temporal dependencies across the three receive axes (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>x<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ,\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>y<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ,\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>z<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) for accurate three dimensional position estimation. The model is trained on simulated MPI signals and evaluated on real\n                    <jats:italic>in vitro<\/jats:italic>\n                    datasets under standard, bending, and heartbeat-like motion conditions.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The proposed method achieves sub-millimeter localization accuracy, with a minimum\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>L<\/mml:mi>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    error of\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>0.103<\/mml:mn>\n                          <mml:mo>\u00b1<\/mml:mo>\n                          <mml:mn>0.092<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    mm and mean absolute errors (MAEs) of\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>0.039<\/mml:mn>\n                          <mml:mo>\u00b1<\/mml:mo>\n                          <mml:mn>0.046<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    mm,\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>0.054<\/mml:mn>\n                          <mml:mo>\u00b1<\/mml:mo>\n                          <mml:mn>0.049<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    mm, and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>0.060<\/mml:mn>\n                          <mml:mo>\u00b1<\/mml:mo>\n                          <mml:mn>0.044<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    mm along the\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo stretchy=\"false\">(<\/mml:mo>\n                          <mml:mi>x<\/mml:mi>\n                          <mml:mo>,<\/mml:mo>\n                          <mml:mi>y<\/mml:mi>\n                          <mml:mo>,<\/mml:mo>\n                          <mml:mi>z<\/mml:mi>\n                          <mml:mo stretchy=\"false\">)<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    axes, respectively, for the bending dataset. Across all datasets, the MAE ranges from\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>0.165<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    mm to\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>0.655<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    mm, demonstrating consistent performance. The optimized inference achieves a latency of\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>0.55<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ms per frame and a throughput of approximately\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>1800<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    frames\u2009s\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi\/>\n                            <mml:mo>\u22121<\/mml:mo>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    , confirming real-time capability.\n                    <jats:italic>Significance.<\/jats:italic>\n                    Compared with conventional MPI-guided approaches relying on image reconstruction, the proposed framework provides improved accuracy, reduced latency, and enhanced robustness under complex motion conditions. These results highlight the potential of harmonic-aware transformer models as efficient and scalable solutions for real-time catheter localization in interventional MPI.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae794f","type":"journal-article","created":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T22:56:11Z","timestamp":1780700171000},"page":"135015","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Harmonic-aware transformer for real-time catheter localization in interventional procedures of magnetic particle imaging"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1405-8022","authenticated-orcid":true,"given":"Abuobaida M","family":"Khair","sequence":"first","affiliation":[{"name":"School of Control Science and Engineering, Shandong University"},{"name":"Al-Neelain University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjing","family":"Jiang","sequence":"additional","affiliation":[{"name":"School of Control Science and Engineering, Shandong University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoli","family":"Yang","sequence":"additional","affiliation":[{"name":"Weifang Xinli Superconducting Magnet Technology Co., Ltd"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moritz","family":"Wildgruber","sequence":"additional","affiliation":[{"name":"University Hospital, LMU Munich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4407-7045","authenticated-orcid":true,"given":"Xiaopeng","family":"Ma","sequence":"additional","affiliation":[{"name":"School of Control Science and Engineering, Shandong University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,7,2]]},"reference":[{"key":"pmbae794fbib1","doi-asserted-by":"publisher","first-page":"3301","DOI":"10.1109\/TMI.2022.3183948","type":"journal-article","article-title":"First dedicated balloon catheter for magnetic particle imaging","volume":"41","author":"Ahlborg","year":"2022","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae794fbib2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-42620-1","type":"journal-article","article-title":"Harmonic dependence of thermal magnetic particle imaging","volume":"13","author":"Bui","year":"2023","journal-title":"Sci. Rep."},{"key":"pmbae794fbib3","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ada5a1","type":"journal-article","article-title":"An \u21131-plug-and-play approach for MPI using a zero-shot denoiser","volume":"70","author":"Gapyak","year":"2025","journal-title":"Phys. Med. Biol."},{"key":"pmbae794fbib4","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1038\/nature03808","type":"journal-article","article-title":"Tomographic imaging using the nonlinear response of magnetic particles","volume":"435","author":"Gleich","year":"2005","journal-title":"Nature"},{"key":"pmbae794fbib5","doi-asserted-by":"publisher","DOI":"10.18416\/ijmpi.2017.1703011","type":"journal-article","article-title":"Submillimeter-accurate marker localization within low gradient magnetic particle imaging tomograms","volume":"3","author":"Griese","year":"2017","journal-title":"Int. J. Magn. Part. Imaging"},{"key":"pmbae794fbib6","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0230821","type":"journal-article","article-title":"In-vitro MPI-guided IVOCT catheter tracking in real time for motion artifact compensation","volume":"15","author":"Griese","year":"2020","journal-title":"PLoS One"},{"key":"pmbae794fbib7","doi-asserted-by":"publisher","DOI":"10.5281\/zenodo.3554935","type":"dataset","article-title":"Datsets for Publication \u201cIn-Vitro MPI-Guided IVOCT Catheter Tracking in Real Time for Motion Artifact Compensation\u201d","author":"Griese","year":"2020","unstructured":"Griese F et al 2020 Datsets for Publication \u201cIn-Vitro MPI-Guided IVOCT Catheter Tracking in Real Time for Motion Artifact Compensation\u201d Zenodo 10.5281\/zenodo.3554935"},{"key":"pmbae794fbib8","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40779-025-00603-5","type":"journal-article","article-title":"Exploring the diagnostic potential: magnetic particle imaging for brain diseases","volume":"12","author":"Guo","year":"2025","journal-title":"Mil. Med. Res."},{"key":"pmbae794fbib9","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1148\/radiol.12120424","type":"journal-article","article-title":"Magnetic particle imaging: visualization of instruments for cardiovascular intervention","volume":"265","author":"Haegele","year":"2012","journal-title":"Radiology"},{"key":"pmbae794fbib10","doi-asserted-by":"publisher","first-page":"800","DOI":"10.3390\/diagnostics10100800","type":"journal-article","article-title":"The applications of magnetic particle imaging: from cell to body","volume":"10","author":"Han","year":"2020","journal-title":"Diagnostics"},{"key":"pmbae794fbib11","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1038\/s43856-025-00794-x","type":"journal-article","article-title":"Magnetic particle imaging angiography of the femoral artery in a human cadaveric perfusion model","volume":"5","author":"Hartung","year":"2025","journal-title":"Commun. Med."},{"key":"pmbae794fbib12","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1007\/s00270-018-1955-7","type":"journal-article","article-title":"Magnetic particle imaging guided real-time percutaneous transluminal angioplasty in a phantom model","volume":"41","author":"Herz","year":"2018","journal-title":"Cardiovasc. Intervent. Radiol."},{"key":"pmbae794fbib13","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1177\/1526602819851202","type":"journal-article","article-title":"Magnetic particle imaging-guided stenting","volume":"26","author":"Herz","year":"2019","journal-title":"J. Endovasc. Ther."},{"key":"pmbae794fbib14","article-title":"Single harmonic based narrowband magnetic particle imaging","author":"Janssen","year":"2021","type":"preprint"},{"key":"pmbae794fbib15","author":"Knopp","year":"2012","type":"book"},{"key":"pmbae794fbib16","doi-asserted-by":"publisher","first-page":"e1757","DOI":"10.1002\/wnan.1757","type":"journal-article","article-title":"Magnetic particle imaging for assessment of cerebral perfusion and ischemia","volume":"14","author":"Ludewig","year":"2022","journal-title":"WIREs Nanomed. Nanobiotechnol."},{"key":"pmbae794fbib17","doi-asserted-by":"publisher","first-page":"3097","DOI":"10.2147\/IJN.S70488","type":"journal-article","article-title":"Magnetic particle imaging: Current developments and future directions","volume":"10","author":"Panagiotopoulos","year":"2015","journal-title":"Int. J. Nanomedicine"},{"key":"pmbae794fbib18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1471-2342-9-4","type":"journal-article","article-title":"Signal encoding in magnetic particle imaging: properties of the system function","volume":"9","author":"Rahmer","year":"2009","journal-title":"BMC Med. Imaging"},{"key":"pmbae794fbib19","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1109\/TMI.2017.2679099","type":"journal-article","article-title":"Interactive magnetic catheter steering with 3-D real-time feedback using multi-color magnetic particle imaging","volume":"36","author":"Rahmer","year":"2017","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae794fbib20","doi-asserted-by":"publisher","first-page":"11802","DOI":"10.1039\/D4NR01195C","type":"journal-article","article-title":"Magnetic nanoparticles for magnetic particle imaging (MPI): design and applications","volume":"16","author":"Rezaei","year":"2024","journal-title":"Nanoscale"},{"key":"pmbae794fbib21","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0156899","type":"journal-article","article-title":"Magnetic particle\/magnetic resonance imaging: in vitro MPI-guided real-time catheter tracking and 4D angioplasty","volume":"11","author":"Salamon","year":"2016","journal-title":"PLoS One"},{"key":"pmbae794fbib22","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad078d","type":"journal-article","article-title":"An adaptive multi-frame parallel iterative method for accelerating real-time magnetic particle imaging reconstruction","volume":"68","author":"Shen","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbae794fbib23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2025.3535575","type":"journal-article","article-title":"Content-aware distillation network for real-time magnetic particle imaging","volume":"74","author":"Shi","year":"2025","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"pmbae794fbib24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2025.3580831","type":"journal-article","article-title":"Multidimensional information fusion learning for real-time signal denoising in magnetic particle imaging","volume":"74","author":"Sun","year":"2025","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"pmbae794fbib25","doi-asserted-by":"publisher","first-page":"3279","DOI":"10.1088\/0031-9155\/61\/9\/3279","type":"journal-article","article-title":"Increasing the sensitivity for stem cell monitoring in system-function based magnetic particle imaging","volume":"61","author":"Them","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"pmbae794fbib26","doi-asserted-by":"publisher","first-page":"1592","DOI":"10.1002\/mp.13411","type":"journal-article","article-title":"Trajectory analysis for field free line magnetic particle imaging","volume":"46","author":"Top","year":"2019","journal-title":"Med. Phys."},{"key":"pmbae794fbib27","first-page":"pp 5999","type":"conference-proceedings","article-title":"Attention is all you need","volume":"vol 30","author":"Vaswani","year":"2017"},{"key":"pmbae794fbib28","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-37351-2","type":"journal-article","article-title":"iMPI: Portable human-sized magnetic particle imaging scanner for real-time endovascular interventions","volume":"13","author":"Vogel","year":"2023","journal-title":"Sci. Rep."},{"key":"pmbae794fbib29","doi-asserted-by":"publisher","first-page":"1988","DOI":"10.1118\/1.2903449","type":"journal-article","article-title":"Frequency distribution of nanoparticle magnetization in static and harmonic magnetic fields","volume":"35","author":"Weaver","year":"2008","journal-title":"Med. Phys."},{"key":"pmbae794fbib30","doi-asserted-by":"publisher","first-page":"2137","DOI":"10.2147\/IJN.S447823","type":"journal-article","article-title":"Bare-metal stent tracking with magnetic particle imaging","volume":"19","author":"Wegner","year":"2024","journal-title":"Int. J. Nanomed."},{"key":"pmbae794fbib31","doi-asserted-by":"publisher","first-page":"L1","DOI":"10.1088\/0031-9155\/54\/5\/L01","type":"journal-article","article-title":"Three-dimensional real-time in vivo magnetic particle imaging","volume":"54","author":"Weizenecker","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmbae794fbib32","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2024.108783","type":"journal-article","article-title":"Dual-channel end-to-end network with prior knowledge embedding for improving spatial resolution of magnetic particle imaging","volume":"178","author":"Wen","year":"2024","journal-title":"Comput. Biol. Med."},{"key":"pmbae794fbib33","doi-asserted-by":"publisher","first-page":"2884","DOI":"10.1118\/1.4948998","type":"journal-article","article-title":"Geometry planning and image registration in magnetic particle imaging using bimodal fiducial markers","volume":"43","author":"Werner","year":"2016","journal-title":"Med. Phys."},{"key":"pmbae794fbib34","doi-asserted-by":"publisher","first-page":"5492","DOI":"10.1002\/mp.17104","type":"journal-article","article-title":"MPIGAN: An end-to-end deep generative framework for high-resolution magnetic particle imaging reconstruction","volume":"51","author":"Zhao","year":"2024","journal-title":"Med. Phys."},{"key":"pmbae794fbib35","doi-asserted-by":"publisher","DOI":"10.1038\/srep14055","type":"journal-article","article-title":"Magnetic particle imaging tracks the long-term fate of in vivo neural cell implants","volume":"5","author":"Zheng","year":"2015","journal-title":"Sci. Rep."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T09:56:44Z","timestamp":1782986204000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae794f"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,2]]},"references-count":35,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2026,7,2]]},"published-print":{"date-parts":[[2026,7,14]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae794f","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,2]]},"assertion":[{"value":"Harmonic-aware transformer for real-time catheter localization in interventional procedures of magnetic particle imaging","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-03-26","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-05","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-02","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}