{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T05:04:56Z","timestamp":1784178296951,"version":"3.55.0"},"reference-count":31,"publisher":"IOP Publishing","issue":"14","license":[{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100025019","name":"Support for Pioneering Research Initiated by the Next Generation","doi-asserted-by":"crossref","award":["JPMJSP2109"],"award-info":[{"award-number":["JPMJSP2109"]}],"id":[{"id":"10.13039\/501100025019","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,7,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    The forceps-type positron emission counter (PEC) was developed for intraoperative quantification of\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mn>18<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    F-fluorodeoxyglucose uptake in individual lymph nodes. It employs coincidence detection between two opposing\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>2<\/mml:mn>\n                          <mml:mo>\u00d7<\/mml:mo>\n                          <mml:mn>2<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    bismuth germanate crystal arrays, yielding only 16 lines of response (LOR). This study investigates the feasibility of image reconstruction from these 16 LORs to enable repositioning guidance and sensitivity-corrected quantification.\n                    <jats:italic>Approach.<\/jats:italic>\n                    Seven reconstruction algorithms\u2014spanning different data-fidelity models (least-squares (LS) and Poisson likelihood), regularization priors (none,\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>L<\/mml:mi>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    Tikhonov, and total variation), and optimization frameworks\u2014were compared using Geant4-based Monte Carlo simulations. Phantom experiments assessed reconstruction quality and count-rate dependence, localization accuracy across the field of view, hot-background robustness, and dual-source separation.\n                    <jats:italic>Main results.<\/jats:italic>\n                    Among the tested design axes, regularization has the largest impact on reconstruction quality, and the optimal algorithm depends on the task: MAP-EM-TV (Poisson-likelihood with TV regularization) achieves the highest structural similarity while PLS-TV (LS with TV) achieves the best quantitative accuracy (FoV-sum CV reduced by 21.5 percentage points) and a mean localization error of 1.27 mm. Near-optimal image quality is reached at\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u223c<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    3000 counts, with spatial information retained down to\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u223c<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    100 counts; image quality degrades substantially below source-to-background ratio 12:1.\n                    <jats:italic>Significance.<\/jats:italic>\n                    The results demonstrate that the 16-LOR PEC can provide spatial information beyond count-rate or center-of-gravity estimation, enabling repositioning guidance and sensitivity-corrected quantification for intraoperative use. As the study relies on a shared forward model, validation with a physical prototype is the key next step.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/ae8356","type":"journal-article","created":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T22:54:31Z","timestamp":1782514471000},"page":"145004","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Feasibility study of image reconstruction for a forceps-type positron emission counter: a simulation-based algorithm comparison"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-7852-3422","authenticated-orcid":true,"given":"Ryotaro","family":"Ohashi","sequence":"first","affiliation":[{"name":"National Institutes for Quantum Science and Technology"},{"name":"Chiba University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sodai","family":"Takyu","sequence":"additional","affiliation":[{"name":"National Institutes for Quantum Science and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeki","family":"Ito","sequence":"additional","affiliation":[{"name":"Mirai Imaging Corporation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miwako","family":"Takahashi","sequence":"additional","affiliation":[{"name":"National Institutes for Quantum Science and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taiga","family":"Yamaya","sequence":"additional","affiliation":[{"name":"National Institutes for Quantum Science and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,7,16]]},"reference":[{"key":"pmbae8356bib1","doi-asserted-by":"publisher","first-page":"1322","DOI":"10.1109\/TMI.2018.2799231","type":"journal-article","article-title":"Learned primal-dual reconstruction","volume":"37","author":"Adler","year":"2018","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae8356bib2","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/S0168-9002(03)01368-8","type":"journal-article","article-title":"Geant4\u2014a simulation toolkit","volume":"506","author":"Agostinelli","year":"2003","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbae8356bib3","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1097\/00000658-199409000-00012","type":"journal-article","article-title":"Radical lymph node dissection for cancer of the thoracic esophagus","volume":"220","author":"Akiyama","year":"1994","journal-title":"Ann. Surg."},{"key":"pmbae8356bib4","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.nima.2016.06.125","type":"journal-article","article-title":"Recent developments in Geant4","volume":"835","author":"Allison","year":"2016","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbae8356bib5","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1016\/j.ejmp.2015.07.139","type":"journal-article","article-title":"PETSTEP: generation of synthetic PET lesions for fast evaluation of segmentation methods","volume":"31","author":"Berthon","year":"2015","journal-title":"Phys. Med."},{"key":"pmbae8356bib6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1561\/2200000016","type":"journal-article","article-title":"Distributed optimization and statistical learning via the alternating direction method of multipliers","volume":"3","author":"Boyd","year":"2011","journal-title":"Found. Trends Mach. Learn."},{"key":"pmbae8356bib7","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1023\/B:JMIV.0000011325.36760.1e","type":"journal-article","article-title":"An algorithm for total variation minimization and applications","volume":"20","author":"Chambolle","year":"2004","journal-title":"J. Math. Imaging Vis."},{"key":"pmbae8356bib8","author":"Cherry","year":"2012","edition":"4th edn","type":"book"},{"key":"pmbae8356bib9","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1109\/42.52985","type":"journal-article","article-title":"Bayesian reconstructions from emission tomography data using a modified EM algorithm","volume":"9","author":"Green","year":"1990","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae8356bib10","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s40658-020-0279-2","type":"journal-article","article-title":"Comments on the NEMA NU 4-2008 standard on performance measurement of small animal positron emission tomographs","volume":"7","author":"Hallen","year":"2020","journal-title":"EJNMMI Phys."},{"key":"pmbae8356bib11","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1109\/42.363108","type":"journal-article","article-title":"Accelerated image reconstruction using ordered subsets of projection data","volume":"13","author":"Hudson","year":"1994","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae8356bib12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10120-022-01331-8","type":"journal-article","article-title":"Japanese gastric cancer treatment guidelines 2021","volume":"26","author":"Japanese Gastric Cancer Association","year":"2023","journal-title":"Gastric Cancer"},{"key":"pmbae8356bib13","doi-asserted-by":"publisher","author":"Kaipio","year":"2005","DOI":"10.1007\/b138659","type":"book"},{"key":"pmbae8356bib14","doi-asserted-by":"publisher","first-page":"329","DOI":"10.5090\/kjtcs.2017.50.5.329","type":"journal-article","article-title":"Patterns and prognostic significance of cervical lymph node metastasis and the efficacy of cervical node dissection in esophageal cancer","volume":"50","author":"Kang","year":"2017","journal-title":"Korean J. Thorac. Cardiovasc. Surg."},{"key":"pmbae8356bib15","first-page":"306","type":"journal-article","article-title":"EM reconstruction algorithms for emission and transmission tomography","volume":"8","author":"Lange","year":"1984","journal-title":"J. Comput. Assist. Tomogr."},{"key":"pmbae8356bib16","article-title":"NEMA standards publication NU2-2018: performance measurements of positron emission tomographs (PET)","author":"National Electrical Manufacturers Association","year":"2018","type":"other"},{"key":"pmbae8356bib17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/NSSMICRTSD49126.2023.10338067","type":"conference-proceedings","article-title":"Estimated random rate for an intraoperative use of the forceps-type coincidence detector","author":"Ohashi","year":"2023"},{"key":"pmbae8356bib18","type":"journal-article","article-title":"Simulation development of a machine-learning-based method to localize a radioactive source center of gravity for a forceps-type positron emission counter","author":"Ohashi","year":"2025","journal-title":"Phys. Med. Biol."},{"key":"pmbae8356bib19","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1145\/355984.355989","type":"journal-article","article-title":"LSQR: an algorithm for sparse linear equations and sparse least squares","volume":"8","author":"Paige","year":"1982","journal-title":"ACM Trans. Math. Softw."},{"key":"pmbae8356bib20","doi-asserted-by":"publisher","first-page":"1534","DOI":"10.1007\/s00259-007-0430-5","type":"journal-article","article-title":"Positron detection for the intraoperative localisation of cancer deposits","volume":"34","author":"Piert","year":"2007","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbae8356bib21","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/1477-7819-7-11","type":"journal-article","article-title":"A comprehensive overview of radioguided surgery using gamma detection probe technology","volume":"7","author":"Povoski","year":"2009","journal-title":"World J. Surg. Oncol."},{"key":"pmbae8356bib22","doi-asserted-by":"publisher","first-page":"R541","DOI":"10.1088\/0031-9155\/51\/15\/R01","type":"journal-article","article-title":"Iterative reconstruction techniques in emission computed tomography","volume":"51","author":"Qi","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"pmbae8356bib23","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1016\/j.ejmp.2020.10.011","type":"journal-article","article-title":"3D TOF-PET image reconstruction using total variation regularization","volume":"80","author":"Raczy\u0144ski","year":"2020","journal-title":"Phys. Med."},{"key":"pmbae8356bib24","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20230292","type":"journal-article","article-title":"AI for PET image reconstruction","volume":"96","author":"Reader","year":"2023","journal-title":"Br. J. Radiol."},{"key":"pmbae8356bib25","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/0167-2789(92)90242-F","type":"journal-article","article-title":"Nonlinear total variation based noise removal algorithms","volume":"60","author":"Rudin","year":"1992","journal-title":"Phys. D"},{"key":"pmbae8356bib26","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1109\/TMI.1982.4307558","type":"journal-article","article-title":"Maximum likelihood reconstruction for emission tomography","volume":"1","author":"Shepp","year":"1982","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmbae8356bib27","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1007\/s12149-021-01701-9","type":"journal-article","article-title":"A design of forceps-type coincidence radiation detector for intraoperative LN diagnosis: clinical impact estimated from LNs data of 20 esophageal cancer patients","volume":"36","author":"Takahashi","year":"2022","journal-title":"Ann. Nucl. Med."},{"key":"pmbae8356bib28","author":"Tikhonov","year":"1977","type":"book"},{"key":"pmbae8356bib29","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ejmp.2012.05.002","type":"journal-article","article-title":"Intraoperative gamma cameras for radioguided surgery: technical characteristics, performance parameters and clinical applications","volume":"29","author":"Tsuchimochi","year":"2013","journal-title":"Phys. Med."},{"key":"pmbae8356bib30","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TIP.2003.819861","type":"journal-article","article-title":"Image quality assessment: from error visibility to structural similarity","volume":"13","author":"Wang","year":"2004","journal-title":"IEEE Trans. Image Process."},{"key":"pmbae8356bib31","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1097\/RLU.0000000000003224","type":"journal-article","article-title":"One-by-one comparison of lymph nodes between 18F-FDG uptake and pathological diagnosis in esophageal cancer","volume":"45","author":"Yoshimura","year":"2020","journal-title":"Clin. Nucl. Med."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T04:36:26Z","timestamp":1784176586000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/ae8356"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,16]]},"references-count":31,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2026,7,16]]},"published-print":{"date-parts":[[2026,7,28]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/ae8356","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,16]]},"assertion":[{"value":"Feasibility study of image reconstruction for a forceps-type positron emission counter: a simulation-based algorithm comparison","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-04-02","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-26","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-16","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}