{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T08:38:36Z","timestamp":1789115916387,"version":"build-2803163510"},"reference-count":45,"publisher":"IOP Publishing","issue":"17","license":[{"start":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T00:00:00Z","timestamp":1789084800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T00:00:00Z","timestamp":1789084800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,9,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Time calibration is an important procedure for correcting time shifts inherently included in TOF-PET. In this work, we developed a time skew (TS) correction method that uses the intrinsic radioactivity originating from the natural decay of\n                    <jats:sup>176<\/jats:sup>\n                    Lu, a constituent element of the scintillator.\n                    <jats:italic>Approach.<\/jats:italic>\n                    The TOF-PET detector has a one-to-one optical coupling between the scintillators and photosensors, enabling independent readout of each channel. For electrical TS correction caused by the electronic circuitry, the electrical TS is estimated from the time-stamp difference between beta particles from\n                    <jats:sup>176<\/jats:sup>\n                    Lu, used as a trigger, and the simultaneously emitted prompt gamma rays. The correction is performed in two stages, first within each detector and then between detectors. Although crystal TS originating from the scintillator can also be corrected using\n                    <jats:sup>176<\/jats:sup>\n                    Lu, obtaining sufficient statistics requires a long acquisition time. Therefore, we focused on the linear correlation between the light output of each crystal and the crystal TS, and implemented a simple crystal TS correction based on a formulation derived from the existing timing correction method.\n                    <jats:italic>Main results.<\/jats:italic>\n                    When the proposed method was applied to coincidence measurements using a pair of TOF-PET detectors, a coincidence resolving time of 232 ps was achieved using only\n                    <jats:sup>176<\/jats:sup>\n                    Lu background data, which was comparable to the 230 ps obtained with the existing method using an external source.\n                    <jats:italic>Significance.<\/jats:italic>\n                    The developed method is expected not only to simplify timing correction but also to reduce downtime during detector replacement.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/aea1d5","type":"journal-article","created":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T22:56:21Z","timestamp":1788389781000},"page":"175034","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Lu-176 based time skew correction method for TOF-PET detectors"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4269-2618","authenticated-orcid":true,"given":"Eiji","family":"Yoshida","sequence":"first","affiliation":[{"name":"National Institutes for Quantum Science and Technology (QST)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fujino","family":"Obata","sequence":"additional","affiliation":[{"name":"National Institutes for Quantum Science and Technology (QST)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taiga","family":"Yamaya","sequence":"additional","affiliation":[{"name":"National Institutes for Quantum Science and Technology (QST)"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,9,11]]},"reference":[{"key":"pmbaea1d5bib1","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.nima.2008.10.024","type":"journal-article","article-title":"A handy time alignment probe for timing calibration of PET scanners","volume":"599","author":"Bergeron","year":"2009","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea1d5bib2","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1118\/1.3676688","type":"journal-article","article-title":"Use of internal scintillator radioactivity to calibrate DOI function of a PET detector with a dual-ended-scintillator readout","volume":"39","author":"Bircher","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaea1d5bib3","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2020.164817","type":"journal-article","article-title":"PET timing calibration using low rank constraint","volume":"987","author":"Chen","year":"2021","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea1d5bib4","doi-asserted-by":"publisher","first-page":"3700","DOI":"10.1088\/1361-6560\/aa68ca","type":"journal-article","article-title":"Characterization of 176Lu background in LSO-based PET scanners","volume":"62","author":"Conti","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib5","doi-asserted-by":"publisher","first-page":"8010","DOI":"10.1002\/mp.15318","type":"journal-article","article-title":"Timing evaluation of a PET detector block based on semi-monolithic LYSO crystals","volume":"48","author":"Cucarella","year":"2021","journal-title":"Med. Phys."},{"key":"pmbaea1d5bib6","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aabeda","type":"journal-article","article-title":"Time-of-flight PET time calibration using data consistency","volume":"63","author":"Defrise","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib7","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1109\/TRPMS.2017.2726534","type":"journal-article","article-title":"A time-walk correction method for PET detectors based on leading edge discriminators","volume":"1","author":"Du","year":"2017","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbaea1d5bib8","doi-asserted-by":"publisher","first-page":"1692","DOI":"10.2967\/jnumed.107.040584","type":"journal-article","article-title":"Imaging of weak-source distributions in LSO-based small-animal PET scanners","volume":"48","author":"Goertzen","year":"2007","journal-title":"J. Nucl. Med."},{"key":"pmbaea1d5bib9","doi-asserted-by":"publisher","first-page":"2074","DOI":"10.1109\/TNS.2002.803787","type":"journal-article","article-title":"Development of a daily quality check procedure for the high-resolution research tomograph (HRRT) using natural LSO background radioactivity","volume":"49","author":"Knoess","year":"2002","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaea1d5bib10","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ejmp.2019.12.004","type":"journal-article","article-title":"Exploring TOF capabilities of PET detector blocks based on large monolithic crystals and analog SiPMs","volume":"70","author":"Lamprou","year":"2020","journal-title":"Phys. Med."},{"key":"pmbaea1d5bib11","article-title":"Achieving accurate time-of-flight calibrations with a stationary coincidence point source","author":"Laurence","year":"2010","type":"patent"},{"key":"pmbaea1d5bib12","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad6edb","type":"journal-article","article-title":"Timing offset calibration for TOF PET using stationary line source scans at multiple positions","volume":"69","author":"Li","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib13","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1109\/TNS.2016.2519284","type":"journal-article","article-title":"Timing calibration for time-of-flight PET using positron-emitting isotopes and annihilation targets","volume":"63","author":"Li","year":"2016","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaea1d5bib14","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s40658-024-00711-6","type":"journal-article","article-title":"Improving timing resolution of BGO for TOF-PET: A comparative analysis with and without deep learning","volume":"12","author":"Loignon-Houle","year":"2025","journal-title":"EJNMMI Phys."},{"key":"pmbaea1d5bib15","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1109\/TNS.2006.887469","type":"journal-article","article-title":"Use of a central positron emitting reference source to improve the timing alignment of a singles list-mode small animal PET scanner","volume":"54","author":"McElroy","year":"2007","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaea1d5bib16","doi-asserted-by":"publisher","first-page":"2660","DOI":"10.1109\/tns.2006.882797","type":"journal-article","article-title":"Timing calibration in PET using a time alignment probe","volume":"53","author":"Moses","year":"2006","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaea1d5bib17","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad63ec","type":"journal-article","article-title":"Holistic evaluation of a machine learning-based timing calibration for PET detectors under varying data sparsity","volume":"69","author":"Naunheim","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib18","article-title":"Time-correction device for pet system","author":"Niu","year":"2022","type":"patent"},{"key":"pmbaea1d5bib19","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1109\/TNS.2007.912876","type":"journal-article","article-title":"Digital coincidence processing for the RatCAP conscious rat brain PET scanner","volume":"55","author":"Park","year":"2008","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaea1d5bib20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/NSSMIC.2013.6829400","type":"journal-article","article-title":"Time alignment of time of flight positron emission tomography using the background activity of LSO","author":"Rothfuss","year":"2013","journal-title":"Nucl. Sci. Symp. Med. Imaging Conf. (2013 NSS\/MIC)"},{"key":"pmbaea1d5bib21","doi-asserted-by":"publisher","first-page":"5483","DOI":"10.1088\/0031-9155\/59\/18\/5483","type":"journal-article","article-title":"LSO background radiation as a transmission source using time of flight","volume":"59","author":"Rothfuss","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.nima.2018.01.049","type":"journal-article","article-title":"A fully automated and scalable timing probe-based method for time alignment of the LabPET II scanners","volume":"889","author":"Samson","year":"2018","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea1d5bib23","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1109\/TRPMS.2021.3084539","type":"journal-article","article-title":"Time of flight in perspective: Instrumental and computational aspects of time resolution in positron emission tomography","volume":"5","author":"Schaart","year":"2021","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbaea1d5bib24","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1109\/TNS.2017.2654920","type":"journal-article","article-title":"Crystal delay and time walk correction methods for coincidence resolving time improvements of a digital-silicon-photomultiplier-based PET\/MRI insert","volume":"1","author":"Schug","year":"2017","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbaea1d5bib25","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1016\/j.radi.2024.04.022","type":"journal-article","article-title":"Quality control performance evaluation of uMI550 digital PET-CT by utilising LYSO crystal natural radioactivity of 176Lu","volume":"30","author":"Singh","year":"2024","journal-title":"Radiography"},{"key":"pmbaea1d5bib26","article-title":"Sub-pixel time skew correction for positron emission tomography (PET)","author":"Solf","year":"2023","type":"patent"},{"key":"pmbaea1d5bib27","article-title":"Online real-time correction method and system for positron emission tomography detector","author":"Sun","year":"2018","type":"patent"},{"key":"pmbaea1d5bib28","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.ejmp.2020.10.031","type":"journal-article","article-title":"Update on latest advances in time-of-flight PET","volume":"80","author":"Surti","year":"2020","journal-title":"Phys. Med."},{"key":"pmbaea1d5bib29","doi-asserted-by":"publisher","first-page":"1300","DOI":"10.1109\/TNS.2005.858234","type":"journal-article","article-title":"A central positron source to perform the timing alignment of detectors in a PET scanner","volume":"52","author":"Thompson","year":"2005","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"pmbaea1d5bib30","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1109\/TRPMS.2024.3497774","type":"journal-article","article-title":"A time-walk and timing-shift correction method for dual-ended readout TOF-DOI PET detectors","volume":"9","author":"Wang","year":"2025","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbaea1d5bib31","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2020.164202","type":"journal-article","article-title":"Energy calibration using scintillator background radiation for high-resolution PET detectors","volume":"974","author":"Wang","year":"2020","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea1d5bib32","first-page":"822","type":"journal-article","article-title":"NEMA NU 2 performance tests for scanners with intrinsic radioactivity","volume":"45","author":"Watson","year":"2004","journal-title":"J. Nucl. Med."},{"key":"pmbaea1d5bib33","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/adabaf","type":"journal-article","article-title":"Crystal-level timing calibration using cascaded photons of60Co point source for long axial animal PET system","volume":"70","author":"Wei","year":"2025","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib34","doi-asserted-by":"publisher","first-page":"02NT01","DOI":"10.1088\/1361-6560\/aa9c28","type":"journal-article","article-title":"Crystal identification for a dual-layer-offset LYSO based PET system via lu-176 background radiation and mean shift algorithm","volume":"63","author":"Wei","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib35","doi-asserted-by":"publisher","first-page":"4031","DOI":"10.1088\/0031-9155\/58\/12\/4031","type":"journal-article","article-title":"TOF PET offset calibration from clinical data","volume":"58","author":"Werner","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib36","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1109\/TRPMS.2020.2981388","type":"journal-article","article-title":"Methods to compensate the time walk errors in timing measurements for PET detectors","volume":"4","author":"Xie","year":"2020","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbaea1d5bib37","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.nima.2019.03.083","type":"journal-article","article-title":"PET detectors with 127 ps CTR for the tachyon-II time-of-flight PET scanner","volume":"933","author":"Xie","year":"2019","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea1d5bib38","doi-asserted-by":"publisher","first-page":"4681","DOI":"10.3390\/s21144681","type":"journal-article","article-title":"Optical simulation and experimental assessment with time-walk correction of TOF-PET detectors with multi-ended readouts","volume":"21","author":"Xie","year":"2021","journal-title":"Sensors"},{"key":"pmbaea1d5bib39","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/BF03027389","type":"journal-article","article-title":"Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET","volume":"19","author":"Yamamoto","year":"2005","journal-title":"Ann. Nucl. Med."},{"key":"pmbaea1d5bib40","doi-asserted-by":"publisher","first-page":"4399","DOI":"10.1088\/0031-9155\/53\/16\/012","type":"journal-article","article-title":"Lutetium oxyorthosilicate (LSO) intrinsic activity correction and minimal detectable target activity study for SPECT imaging with a LSO-based animal PET scanner","volume":"53","author":"Yao","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib41","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2023.168114","type":"journal-article","article-title":"Simultaneous time-skew and time-walk correction for TOF-PET detector","volume":"1049","author":"Yoshida","year":"2023","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea1d5bib42","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad5268","type":"journal-article","article-title":"Optical crosstalk of protective cover on MPPC array for TOF PET detector","volume":"69","author":"Yoshida","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib43","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1109\/TRPMS.2025.3551520","type":"journal-article","article-title":"Air-CLS detector: A modified crosshair light-sharing PET detector with air gaps in the U-shape light path","volume":"9","author":"Yoshida","year":"2025","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"pmbaea1d5bib44","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab8c91","type":"journal-article","article-title":"245 ps-TOF brain-dedicated PET prototype with a hemispherical detector arrangement","volume":"65","author":"Yoshida","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbaea1d5bib45","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s12194-014-0258-1","type":"journal-article","article-title":"Reduction method for intrinsic random coincidence events from 176Lu in low activity PET imaging","volume":"7","author":"Yoshida","year":"2014","journal-title":"Radiol. Phys. Technol"}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T07:56:39Z","timestamp":1789113399000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea1d5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,11]]},"references-count":45,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2026,9,11]]},"published-print":{"date-parts":[[2026,9,14]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/aea1d5","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,11]]},"assertion":[{"value":"Lu-176 based time skew correction method for TOF-PET detectors","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-04-09","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-02","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}