{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:01:14Z","timestamp":1792785674330,"version":"4.5.0"},"reference-count":30,"publisher":"IOP Publishing","issue":"19","license":[{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Ministero dell\u2019Universit\u00e0 e della Ricerca","award":["FISA-2022-00779"],"award-info":[{"award-number":["FISA-2022-00779"]}],"id":[{"id":"https:\/\/ror.org\/0341vw408","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,10,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Prompt-gamma imaging is a promising technique for in-situ range verification during proton therapy, with the potential to reduce range uncertainties. Current prompt-gamma cameras typically rely on mechanical collimators, among which the knife-edge slit (KES) and multi-parallel slit (MPS) collimators are the two most widely studied concepts. In this work, we propose a novel inverted (INV) collimator concept that uses a single bar of high-density material to cast a gamma-ray shadow onto the central region of a pixelated scintillation detector. In addition to advantageous properties such as a high efficiency and a large field of view, the INV collimator also features a significantly reduced weight compared to the KES and MPS collimators.\n                    <jats:italic>Approach.<\/jats:italic>\n                    We optimized and compared the different collimator designs with respect to their simulated statistical range retrieval precision. To overcome the computational time limitations associated with full Monte Carlo (MC) simulations, we developed a new hybrid simulation tool based on a dedicated fixed-ray calculation of the collimator combined with precalculated MC simulations of prompt-gamma emission and detection. This approach enables rapid parameter optimization while incorporating all experimentally relevant effects, such as the detector spectral response and an empirical neutron background.\n                    <jats:italic>Main results.<\/jats:italic>\n                    We present optimized collimator geometries for the MPS, KES, and the novel INV collimator. The INV collimator achieves a statistical range retrieval precision (2\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>\u03c3<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) of 2.2 mm at a proton beam energy of 100\u2009MeV and 2.4\u2009mm at 150\u2009MeV for\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mn>10<\/mml:mn>\n                            <mml:mrow>\n                              <mml:mn>8<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    protons irradiating a homogeneous tissue-equivalent phantom, demonstrating performance comparable to the optimized KES design. In addition, we present a first experimental validation of the INV collimator concept at the CNAO hadron therapy facility in Pavia, Italy, demonstrating agreement between the hybrid simulation and measurements.\n                    <jats:italic>Significance.<\/jats:italic>\n                    These results suggest that the INV collimator is a promising concept for future prompt-gamma cameras, offering competitive performance and facilitating clinical implementation due to its reduced device weight.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/aea7f1","type":"journal-article","created":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T22:54:29Z","timestamp":1789512869000},"page":"195024","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Study of a novel inverted collimator concept for prompt-gamma-based range verification in proton therapy using a hybrid simulation approach"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-8824-5986","authenticated-orcid":true,"given":"K","family":"Urban","sequence":"first","affiliation":[{"name":"Politecnico di Milano"},{"name":"National Institute for Nuclear Physics (INFN)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8488-4728","authenticated-orcid":false,"given":"G","family":"Borghi","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"},{"name":"National Institute for Nuclear Physics (INFN)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3485-4317","authenticated-orcid":false,"given":"M","family":"Carminati","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"},{"name":"National Institute for Nuclear Physics (INFN)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-4094-5450","authenticated-orcid":false,"given":"A","family":"Forgione","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"},{"name":"National Institute for Nuclear Physics (INFN)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-1172-3856","authenticated-orcid":false,"given":"M","family":"Piroddi","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"},{"name":"National Institute for Nuclear Physics (INFN)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-4859-5970","authenticated-orcid":false,"given":"C","family":"Riboldi","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"},{"name":"National Institute for Nuclear Physics (INFN)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-7125-3974","authenticated-orcid":false,"given":"L","family":"Santini","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"},{"name":"National Institute for Nuclear Physics (INFN)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-7569-5026","authenticated-orcid":false,"given":"E S","family":"Bellotti","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7481-0653","authenticated-orcid":true,"given":"D","family":"Bortot","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2001-4920","authenticated-orcid":true,"given":"D","family":"Mazzucconi","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1851-431X","authenticated-orcid":true,"given":"M","family":"Pullia","sequence":"additional","affiliation":[{"name":"Centro Nazionale di Adroterapia Oncologica (CNAO)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1157-0143","authenticated-orcid":false,"given":"C","family":"Fiorini","sequence":"additional","affiliation":[{"name":"Politecnico di Milano"},{"name":"National Institute for Nuclear Physics (INFN)"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,10,7]]},"reference":[{"key":"pmbaea7f1bib1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-35684-x","type":"journal-article","article-title":"Understanding the intrinsic radioactivity energy spectrum from 176Lu in LYSO\/LSO scintillation crystals","volume":"8","author":"Alva-S\u00e1nchez","year":"2018","journal-title":"Sci. Rep."},{"key":"pmbaea7f1bib2","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/j.ijrobp.2021.06.036","type":"journal-article","article-title":"First-In-Human validation of CT-based proton range prediction using prompt gamma imaging in prostate cancer treatments","volume":"111","author":"Berthold","year":"2021","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbaea7f1bib3","doi-asserted-by":"publisher","first-page":"1554","DOI":"10.1140\/epjc\/s10052-011-1554-0","type":"journal-article","article-title":"Asymptotic formulae for likelihood-based tests of new physics","volume":"71","author":"Cowan","year":"2011","journal-title":"Eur. Phys. J. C"},{"key":"pmbaea7f1bib4","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaa203","type":"journal-article","article-title":"3D prompt gamma imaging for proton beam range verification","volume":"63","author":"Draeger","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib5","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.nima.2004.03.128","type":"journal-article","article-title":"Charged hadron tumour therapy monitoring by means of PET","volume":"525","author":"Enghardt","year":"2004","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea7f1bib6","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2025.1660605","type":"journal-article","article-title":"Current status and upcoming developments for online adaptive proton therapy enabling a closed feedback loop for near real-time adaptation","volume":"15","author":"Gambetta","year":"2025","journal-title":"Front. Oncol."},{"key":"pmbaea7f1bib7","doi-asserted-by":"publisher","first-page":"5399","DOI":"10.1088\/0031-9155\/59\/18\/5399","type":"journal-article","article-title":"Range assessment in particle therapy based on prompt \u03b3-ray timing measurements","volume":"59","author":"Golnik","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib8","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aad513","type":"journal-article","article-title":"A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy","volume":"63","author":"Hueso-Gonz\u00e1lez","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib9","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acd237","type":"journal-article","article-title":"Analytical modeling and Monte Carlo simulations of multi-parallel slit and knife-edge slit prompt gamma cameras","volume":"68","author":"Huisman","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib10","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-72870-6","type":"journal-article","article-title":"First experimental verification of prompt gamma imaging with carbon ion irradiation","volume":"14","author":"Idrissi","year":"2024","journal-title":"Sci. Rep."},{"key":"pmbaea7f1bib11","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/adc96b","type":"journal-article","article-title":"First experimental test of a coded-mask gamma camera for proton therapy monitoring","volume":"70","author":"Ko\u0142odziej","year":"2025","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib12","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.nima.2017.07.063","type":"journal-article","article-title":"Prompt-gamma monitoring in hadrontherapy: a review","volume":"878","author":"Krimmer","year":"2018","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea7f1bib13","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.radphyschem.2016.04.020","type":"journal-article","article-title":"A comparison of two prompt gamma imaging techniques with collimator-based cameras for range verification in proton therapy","volume":"137","author":"Lin","year":"2017","journal-title":"Radiat. Phys. Chem."},{"key":"pmbaea7f1bib14","doi-asserted-by":"publisher","first-page":"2100","DOI":"10.1118\/1.3694098","type":"journal-article","article-title":"Development of array type prompt gamma measurement system for in vivo range verification in proton therapy","volume":"39","author":"Min","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaea7f1bib15","doi-asserted-by":"publisher","first-page":"177","DOI":"10.3389\/fonc.2016.00177","type":"journal-article","article-title":"Monitoring of hadrontherapy treatments by means of charged particle detection","volume":"6","author":"Muraro","year":"2016","journal-title":"Front. Oncol."},{"key":"pmbaea7f1bib16","doi-asserted-by":"publisher","first-page":"R155","DOI":"10.1088\/0031-9155\/60\/8\/R155","type":"journal-article","article-title":"The physics of proton therapy","volume":"60","author":"Newhauser","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib17","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1016\/j.net.2018.10.002","type":"journal-article","article-title":"Comparison of knife-edge and multi-slit camera for proton beam range verification by Monte Carlo simulation","volume":"51","author":"Park","year":"2019","journal-title":"Nucl. Eng. Technol."},{"key":"pmbaea7f1bib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2018.09.062","type":"journal-article","article-title":"Detection systems for range monitoring in proton therapy: needs and challenges","volume":"954","author":"Pausch","year":"2020","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"pmbaea7f1bib19","doi-asserted-by":"publisher","first-page":"5849","DOI":"10.1088\/0031-9155\/59\/19\/5849","type":"journal-article","article-title":"Prompt gamma imaging of proton pencil beams at clinical dose rate","volume":"59","author":"Perali","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib20","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1140\/epjp\/s13360-024-05664-4","type":"journal-article","article-title":"Prompt-gamma imaging in particle therapy","volume":"139","author":"Pinto","year":"2024","journal-title":"Eur. Phys. J. Plus"},{"key":"pmbaea7f1bib21","doi-asserted-by":"publisher","first-page":"7653","DOI":"10.1088\/0031-9155\/59\/24\/7653","type":"journal-article","article-title":"Design optimisation of a TOF-based collimated camera prototype for online hadrontherapy monitoring","volume":"59","author":"Pinto","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib22","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/20\/09\/P09037","type":"journal-article","article-title":"Design of a 64-channel modular platform for high-speed readout of scintillator-based detectors for range monitoring in hadrontherapy","volume":"20","author":"Riboldi","year":"2025","journal-title":"J. Instrum."},{"key":"pmbaea7f1bib23","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1016\/j.radonc.2016.01.004","type":"journal-article","article-title":"First clinical application of a prompt gamma based in vivo proton range verification system","volume":"118","author":"Richter","year":"2016","journal-title":"Radiother. Oncol."},{"key":"pmbaea7f1bib24","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/addf0d","type":"journal-article","article-title":"Modeling prompt gamma (PG) emission, detection and imaging in real patient anatomy using a novel Compton camera for dose verification in proton therapy","volume":"70","author":"Sharma","year":"2025","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib25","doi-asserted-by":"publisher","first-page":"3371","DOI":"10.1088\/0031-9155\/57\/11\/3371","type":"journal-article","article-title":"Prompt gamma imaging with a slit camera for real-time range control in proton therapy","volume":"57","author":"Smeets","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f1bib26","doi-asserted-by":"publisher","first-page":"156","DOI":"10.3389\/fonc.2016.00156","type":"journal-article","article-title":"Experimental comparison of knife-edge and multi-parallel slit collimators for prompt gamma imaging of proton pencil beams","volume":"6","author":"Smeets","year":"2016","journal-title":"Front. Oncol."},{"key":"pmbaea7f1bib27","doi-asserted-by":"publisher","first-page":"1700","DOI":"10.1118\/1.4943377","type":"journal-article","article-title":"Fast multipurpose Monte Carlo simulation for proton therapy using multi- and many-core CPU architectures","volume":"43","author":"Souris","year":"2016","journal-title":"Med. Phys."},{"key":"pmbaea7f1bib28","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/j.ijrobp.2017.04.027","type":"journal-article","article-title":"Prompt gamma imaging for in vivo range verification of pencil beam scanning proton therapy","volume":"99","author":"Xie","year":"2017","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"pmbaea7f1bib29","doi-asserted-by":"publisher","first-page":"3140","DOI":"10.1016\/j.net.2023.05.028","type":"journal-article","article-title":"Tackling range uncertainty in proton therapy: development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system","volume":"55","author":"Youngmo","year":"2023","journal-title":"Nucl. Eng. Technol."},{"key":"pmbaea7f1bib30","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1109\/TRPMS.2025.3553133","type":"journal-article","article-title":"Proton range verification realized via a multislit prompt gamma imaging system","volume":"9","author":"Zhang","year":"2025","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T06:50:22Z","timestamp":1791355822000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,7]]},"references-count":30,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,10,7]]},"published-print":{"date-parts":[[2026,10,14]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/aea7f1","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,7]]},"assertion":[{"value":"Study of a novel inverted collimator concept for prompt-gamma-based range verification in proton therapy using a hybrid simulation approach","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-15","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-15","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-10-07","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}