{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T05:55:56Z","timestamp":1790574956942,"version":"4.1.0"},"reference-count":49,"publisher":"IOP Publishing","issue":"19","license":[{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,10,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    This study presents a rigorous, simultaneous Monte Carlo (MC) intercomparison of three general-purpose computational codes, MCNP6.2, TOPAS 3.9, and PHITS 3.341, for the calculation and validation of TG-43 dosimetric parameters for the clinical microSelectron-HDR v2\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow\/>\n                            <mml:mrow>\n                              <mml:mn>192<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    Ir and Theragenics-AgX100\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow\/>\n                            <mml:mrow>\n                              <mml:mn>125<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    I brachytherapy sources under realistic, unsimplified photon emission spectra.\n                    <jats:italic>Approach.<\/jats:italic>\n                    Simulations were performed in a spherical liquid water phantom with a radius of 18.5 cm to ensure full-scatter conditions. Dose was scored in small, distance-dependent spherical water scoring cells with varying radii. Discrete, unsimplified photon emission spectra from ICRP Publication 107 were implemented in all three codes. To address gaps in the literature, a computationally efficient simplified geometry previously adopted for the\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow\/>\n                            <mml:mrow>\n                              <mml:mn>192<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    Ir source was evaluated, while the\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow\/>\n                            <mml:mrow>\n                              <mml:mn>125<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    I source was modeled with high geometric fidelity. The radial dose and anisotropy functions were calculated, the radial dose data were fitted using fifth-degree polynomials, and the resulting datasets were benchmarked against established TG-43 consensus reference data.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The three MC codes demonstrated good overall agreement. For the\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow\/>\n                            <mml:mrow>\n                              <mml:mn>192<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    Ir source, the simplified geometry reproduced the consensus reference data within the\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                          <mml:mn>2<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    criterion over the clinically relevant radial range, demonstrating its dosimetric suitability within the TG-43 framework. For the low-energy\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow\/>\n                            <mml:mrow>\n                              <mml:mn>125<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    I source, larger deviations, reaching approximately\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>21<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    , were observed at short radial distances (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>r<\/mml:mi>\n                          <mml:mtext>\u2009<\/mml:mtext>\n                          <mml:mrow>\n                            <mml:mtext>\u2a7d<\/mml:mtext>\n                          <\/mml:mrow>\n                          <mml:mtext>\u2009<\/mml:mtext>\n                          <mml:mn>0.5<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    cm), consistent with the greater sensitivity of low-energy photon transport to attenuation and shielding effects associated with the source encapsulation and internal components. At distances beyond approximately\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>1.0<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    cm, the results showed substantially improved agreement, with deviations generally remaining within\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                          <mml:mn>3<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    . Fifth-degree polynomial fitting accurately reproduced the radial dose function, with deviations predominantly remaining below the recommended\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>2<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    criterion within the clinically relevant radial intervals.\n                    <jats:italic>Significance.<\/jats:italic>\n                    This work establishes a robust, cross-validated computational baseline for brachytherapy dosimetry using general-purpose MC codes under realistic photon emission spectra. The validation of the simplified\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow\/>\n                            <mml:mrow>\n                              <mml:mn>192<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    Ir geometry supports its use in computationally efficient simulations, while the characterization of the low-energy\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mrow\/>\n                            <mml:mrow>\n                              <mml:mn>125<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    I source provides relevant information for high-precision dosimetry and future investigations of low-energy radiation interactions in radiosensitization studies.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/aea7f6","type":"journal-article","created":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T22:54:55Z","timestamp":1789512895000},"page":"195007","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical\n                    <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                      <mml:mrow>\n                        <mml:msup>\n                          <mml:mrow\/>\n                          <mml:mrow>\n                            <mml:mn>192<\/mml:mn>\n                          <\/mml:mrow>\n                        <\/mml:msup>\n                      <\/mml:mrow>\n                    <\/mml:math>\n                    Ir and\n                    <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                      <mml:mrow>\n                        <mml:msup>\n                          <mml:mrow\/>\n                          <mml:mrow>\n                            <mml:mn>125<\/mml:mn>\n                          <\/mml:mrow>\n                        <\/mml:msup>\n                      <\/mml:mrow>\n                    <\/mml:math>\n                    I brachytherapy sources"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6837-6213","authenticated-orcid":true,"given":"Lucas F","family":"Ara\u00fajo","sequence":"first","affiliation":[{"name":"Federal University of Minas Gerais\u2014UFMG"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-6379-683X","authenticated-orcid":true,"given":"Asif","family":"Amin","sequence":"additional","affiliation":[{"name":"Federal University of Minas Gerais\u2014UFMG"},{"name":"Federal University of Minas Gerais\u2014UFMG"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8562-8689","authenticated-orcid":false,"given":"Adriano P","family":"Sabino","sequence":"additional","affiliation":[{"name":"Federal University of Minas Gerais\u2014UFMG"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"writing-original-draft","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2388-5174","authenticated-orcid":false,"given":"Telma C F","family":"Fonseca","sequence":"additional","affiliation":[{"name":"Federal University of Minas Gerais\u2014UFMG"},{"name":"Nuclear Technology Development Center\u2014CDTN"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"data-curation","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]}],"member":"266","published-online":{"date-parts":[[2026,9,28]]},"reference":[{"key":"pmbaea7f6bib1","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/851\/1\/012019","type":"journal-article","article-title":"High dose rate 192ir source calibration: a single institution experience","volume":"851","author":"Abdullah","year":"2017","journal-title":"J. Phys.: Conf. Ser."},{"key":"pmbaea7f6bib2","doi-asserted-by":"publisher","first-page":"693","DOI":"10.17576\/jsm-2020-4903-24","type":"journal-article","article-title":"Monte Carlo investigation on neutron dosimetry parameters of 252Cf isotron brachytherapy source","volume":"49","author":"Ahmadi","year":"2020","journal-title":"Sains Malays."},{"key":"pmbaea7f6bib3","doi-asserted-by":"publisher","first-page":"3848","DOI":"10.1002\/mp.12994","type":"journal-article","article-title":"Dosimetric characterization of a new directional low-dose rate brachytherapy source","volume":"45","author":"Aima","year":"2018","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib4","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2025.111745","type":"journal-article","article-title":"In silico Monte Carlo with novel particle tagging: assessing gold radiosensitivity in voxelized scenario of brachytherapy","volume":"220","author":"Araujo","year":"2025","journal-title":"Appl. Radiat. Isot."},{"key":"pmbaea7f6bib5","author":"Baatout","year":"2023","edition":"1st edn","type":"book"},{"key":"pmbaea7f6bib6","doi-asserted-by":"publisher","first-page":"3048","DOI":"10.1118\/1.4921020","type":"journal-article","article-title":"A generic high-dose rate 192Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism","volume":"42","author":"Ballester","year":"2015","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib7","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.ejmp.2018.09.052","type":"journal-article","article-title":"39 use of the gate\/geant4 platform in high dose rate brachytherapy: dosimetric study of a cobalt 60 source","volume":"56","author":"Bannan","year":"2018","journal-title":"Phys. Med.: Eur. J. Med. Phys."},{"key":"pmbaea7f6bib8","doi-asserted-by":"publisher","first-page":"6208","DOI":"10.1118\/1.4747264","type":"journal-article","article-title":"Report of the task group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation","volume":"39","author":"Beaulieu","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib9","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1016\/j.brachy.2020.12.007","type":"journal-article","article-title":"Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations","volume":"20","author":"Berumen","year":"2021","journal-title":"Brachytherapy"},{"key":"pmbaea7f6bib10","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad1272","type":"journal-article","article-title":"Evaluation of Monte Carlo to support commissioning of the treatment planning system of new pencil beam scanning proton therapy facilities","volume":"69","author":"Botnariuc","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f6bib11","doi-asserted-by":"publisher","first-page":"5315","DOI":"10.3390\/cancers13215315","type":"journal-article","article-title":"Standardization and validation of brachytherapy seeds\u2019 modelling using gate and GGEMS Monte Carlo toolkits","volume":"13","author":"Chatzipapas","year":"2021","journal-title":"Cancers"},{"key":"pmbaea7f6bib12","doi-asserted-by":"publisher","first-page":"36","DOI":"10.33166\/AETiC.2021.03.004","type":"journal-article","article-title":"Monte Carlo computational software and methods in radiation dosimetry","volume":"5","author":"Chatzisavvas","year":"2021","journal-title":"Ann. Emerg. Technol. Comput. (AETiC)"},{"key":"pmbaea7f6bib13","doi-asserted-by":"publisher","first-page":"2200","DOI":"10.1118\/1.598418","type":"journal-article","article-title":"Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source","volume":"25","author":"Daskalov","year":"1998","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib14","doi-asserted-by":"crossref","DOI":"10.2172\/1782721","type":"other","article-title":"Compendium of material composition data for radiation transport modeling","author":"Detwiler","year":"2021"},{"key":"pmbaea7f6bib15","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.ejmp.2020.03.019","type":"journal-article","article-title":"The TOPAS tool for particle simulation, a Monte Carlo simulation tool for physics, biology and clinical research","volume":"72","author":"Faddegon","year":"2020","journal-title":"Phys. Med."},{"key":"pmbaea7f6bib16","doi-asserted-by":"publisher","first-page":"e80","DOI":"10.1017\/S1460396923000079","type":"journal-article","article-title":"Monte-Carlo techniques for radiotherapy applications I: Introduction and overview of the different Monte-Carlo codes","volume":"22","author":"Fielding","year":"2023","journal-title":"J. Radiother. Pract."},{"key":"pmbaea7f6bib17","article-title":"Characterization of HDR Ir-192 source for 3D planning system","author":"Fonseca","year":"2011","type":"conference-proceedings"},{"key":"pmbaea7f6bib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2019.04.045","type":"journal-article","article-title":"MCMEG: Intercomparison exercise on prostate radiotherapy dose assessment","volume":"167","author":"Fonseca","year":"2020","journal-title":"Radiat. Phys. Chem."},{"key":"pmbaea7f6bib19","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1016\/j.radphyschem.2017.03.048","type":"journal-article","article-title":"MCMEG: Simulations of both PDD and TPR for 6 MV LINAC photon beam using different mc codes","volume":"140","author":"Fonseca","year":"2017","journal-title":"Radiat. Phys. Chem."},{"key":"pmbaea7f6bib20","article-title":"Python language reference, version 3.11.2","author":"Foundation","year":"2025","type":"other"},{"key":"pmbaea7f6bib21","doi-asserted-by":"publisher","first-page":"141","DOI":"10.5114\/jcb.2023.126238","type":"journal-article","article-title":"Dosimetric comparison between microSelectron Iridium-192 and flexi Cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code","volume":"15","author":"Gebremariam","year":"2023","journal-title":"J. Contemp. Brachyther."},{"key":"pmbaea7f6bib22","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2021.109666","type":"journal-article","article-title":"Monte Carlo simulation and dosimetry measurements of an experimental approach for in vitro HDR brachytherapy irradiation","volume":"172","author":"Geraldo","year":"2021","journal-title":"Appl. Radiat. Isot."},{"key":"pmbaea7f6bib23","first-page":"7","type":"journal-article","article-title":"Nuclear decay data for dosimetric calculations","volume":"38","author":"ICRP","year":"2008","journal-title":"Ann. ICRP"},{"key":"pmbaea7f6bib24","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1080\/00223131.2021.1993372","type":"journal-article","article-title":"Benchmark study of particle and heavy-ion transport code system using shielding integral benchmark archive and database for accelerator-shielding experiments","volume":"59","author":"Iwamoto","year":"2022","journal-title":"J. Nucl. Sci. Technol."},{"key":"pmbaea7f6bib25","article-title":"Simulation-based low-dose-rate brachytherapy treatment planning","author":"Jerg","year":"2024","type":"other"},{"key":"pmbaea7f6bib26","doi-asserted-by":"publisher","first-page":"3746","DOI":"10.1002\/mp.16948","type":"journal-article","article-title":"RapidBrachyTG43: A Geant4-based TG-43 parameter and dose calculation module for brachytherapy dosimetry","volume":"51","author":"Kalinowski","year":"2024","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib27","doi-asserted-by":"publisher","first-page":"9808","DOI":"10.1038\/s41598-020-66844-7","type":"journal-article","article-title":"A general-purpose Monte Carlo particle transport code based on inverse transform sampling for radiotherapy dose calculation","volume":"10","author":"Liang","year":"2020","journal-title":"Sci. Rep."},{"key":"pmbaea7f6bib28","article-title":"Monte Carlo modelling and expert group (MCMEG)","author":"MCMEG Group","year":"2026","type":"other"},{"key":"pmbaea7f6bib29","doi-asserted-by":"publisher","first-page":"145","DOI":"10.2478\/pjmpe-2024-0017","type":"journal-article","article-title":"Monte Carlo dosimetry for BEBIG cobalt-60 brachytherapy source with gynecological applicator in the presence of inhomogeneities","volume":"30","author":"Moradi","year":"2024","journal-title":"Pol. J. Med. Phys. Eng."},{"key":"pmbaea7f6bib30","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/21\/01\/P01044","type":"journal-article","article-title":"Bridging simulation and clinic: gate-validated 125I brachytherapy dosimetry for oral-maxillofacial metastases","volume":"21","author":"Mostafa","year":"2026","journal-title":"J. Instrum."},{"key":"pmbaea7f6bib31","doi-asserted-by":"publisher","DOI":"10.3389\/fphy.2020.567800","type":"journal-article","article-title":"Challenges in Monte Carlo simulations as clinical and research tool in particle therapy: a review","volume":"8","author":"Muraro","year":"2020","journal-title":"Front. Phys."},{"key":"pmbaea7f6bib32","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/17\/06\/T06009","type":"journal-article","article-title":"Trials of transmission imaging using clinically used ir-192 source for high-dose-rate brachytherapy","volume":"17","author":"Nagata","year":"2022","journal-title":"J. Instrum."},{"key":"pmbaea7f6bib33","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1118\/1.597458","type":"journal-article","article-title":"Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM radiation therapy committee task group no. 43","volume":"22","author":"Nath","year":"1995","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib34","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1118\/1.597966","type":"journal-article","article-title":"Code of practice for brachytherapy physics: report of the AAPM radiation therapy committee task group no. 56","volume":"24","author":"Nath","year":"1997","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib35","doi-asserted-by":"publisher","first-page":"5310","DOI":"10.1118\/1.3246613","type":"journal-article","article-title":"AAMP recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: Report of task group 137","volume":"36","author":"Nath","year":"2009","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib36","doi-asserted-by":"publisher","first-page":"13","DOI":"10.3389\/fonc.2016.00013","type":"journal-article","article-title":"A review of radiotherapy-induced late effects research after advanced technology treatments","volume":"6","author":"Newhauser","year":"2016","journal-title":"Front. Oncol."},{"key":"pmbaea7f6bib37","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1120\/jacmp.v13i3.3741","type":"journal-article","article-title":"Monte Carlo study of a new I-125 brachytherapy prototype seed with a ceramic radionuclide carrier and radiographic marker","volume":"13","author":"Paix\u00e3o","year":"2012","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaea7f6bib38","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1016\/j.ejmp.2016.09.020","type":"journal-article","article-title":"Dosimetric and radiobiological comparison of TG-43 and Monte Carlo calculations in 192ir breast brachytherapy applications","volume":"32","author":"Peppa","year":"2016","journal-title":"Phys. Medica"},{"key":"pmbaea7f6bib39","doi-asserted-by":"publisher","first-page":"2904","DOI":"10.1118\/1.3703892","type":"journal-article","article-title":"Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: report of the AAPM and ESTRO","volume":"39","author":"Perez-Calatayud","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib40","doi-asserted-by":"publisher","first-page":"6818","DOI":"10.1118\/1.4758060","type":"journal-article","article-title":"TOPAS: an innovative proton Monte Carlo platform for research and clinical applications","volume":"39","author":"Perl","year":"2012","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib41","doi-asserted-by":"publisher","first-page":"7125","DOI":"10.1088\/0031-9155\/53\/24\/008","type":"journal-article","article-title":"Calculation of relative biological effectiveness of a low-energy electronic brachytherapy source","volume":"53","author":"Reniers","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"pmbaea7f6bib42","doi-asserted-by":"publisher","first-page":"e297","DOI":"10.1002\/mp.12430","type":"journal-article","article-title":"Supplement 2 for the 2004 update of the AAPM task group no. 43 report: Joint recommendations by the AAPM and GEC-ESTRO","volume":"44","author":"Rivard","year":"2017","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib43","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1118\/1.1646040","type":"journal-article","article-title":"Update of AAPM Task Group no. 43 report: a revised AAPM protocol for brachytherapy dose calculations\u2019","volume":"31","author":"Rivard","year":"2004","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib44","doi-asserted-by":"publisher","first-page":"1928","DOI":"10.1002\/mp.16176","type":"journal-article","article-title":"Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources","volume":"50","author":"Safigholi","year":"2022","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib45","article-title":"Dosimetry studies for brachytherapy sources","author":"Sahoo","year":"2018","type":"other"},{"key":"pmbaea7f6bib46","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1080\/00223131.2023.2275736","type":"journal-article","article-title":"Recent improvements of the particle and heavy ion transport code system - PHITS version 3.33","volume":"61","author":"Sato","year":"2024","journal-title":"J. Nucl. Sci. Technol."},{"key":"pmbaea7f6bib47","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1002\/mp.12702","type":"journal-article","article-title":"Records: improved reporting of Monte Carlo radiation transport studies: report of the AAPM research committee task group 268","volume":"45","author":"Sechopoulos","year":"2018","journal-title":"Med. Phys."},{"key":"pmbaea7f6bib48","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2025.113387","type":"journal-article","article-title":"Monte Carlo investigation of source motion in remote afterloading brachytherapy","volume":"239","author":"Taheri","year":"2025","journal-title":"Radiat. Phys. Chem."},{"key":"pmbaea7f6bib49","article-title":"MCNP users manual-code version 6.2","author":"Werner","year":"2017","type":"other"}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T05:15:33Z","timestamp":1790572533000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea7f6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,28]]},"references-count":49,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,9,28]]},"published-print":{"date-parts":[[2026,10,14]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/aea7f6","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,28]]},"assertion":[{"value":"Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical\n                      \n                        \n                          \n                            \n                            \n                              192\n                            \n                          \n                        \n                      \n                      Ir and\n                      \n                        \n                          \n                            \n                            \n                              125\n                            \n                          \n                        \n                      \n                      I brachytherapy sources","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-20","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-15","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-28","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}