{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:01:17Z","timestamp":1792785677561,"version":"4.5.0"},"reference-count":42,"publisher":"IOP Publishing","issue":"19","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Agencia Estatal de Investigaci\u00f3n","award":["Mar\u00eda de Maeztu Unit of Excellence \/ CEX2023-0013"],"award-info":[{"award-number":["Mar\u00eda de Maeztu Unit of Excellence \/ CEX2023-0013"]}],"id":[{"id":"https:\/\/ror.org\/003x0zc53","id-type":"ROR","asserted-by":"crossref"}]},{"name":"\u2019la Caixa\u2019 Foundation","award":["DosiFLASH \/ HR23-00718"],"award-info":[{"award-number":["DosiFLASH \/ HR23-00718"]}]},{"name":"HORIZON EUROPE European Innovation Council","award":["EIC Pathfinder Open 2021 (101046504 project)"],"award-info":[{"award-number":["EIC Pathfinder Open 2021 (101046504 project)"]}],"id":[{"id":"https:\/\/ror.org\/05cx8cy07","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,10,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    The emergence of ultra-high dose rate (UHDR) electron beams has highlighted the need for accurate Monte Carlo (MC) source models after recent measurements revealed pulse width (PW)\u2013dependent discrepancies in dose profiles. This work aims to develop and validate a MC source model for conventional and FLASH modes using GATE 10, including PW dependence.\n                    <jats:italic>Approach.<\/jats:italic>\n                    Percentage depth dose (PDD) curves and lateral dose profiles were measured in water using a flashDiamond detector for PWs of 0.5\u20135\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>\u03bc<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    s. These data were used to optimize the parametric source model through\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msup>\n                            <mml:mi>\u03c7<\/mml:mi>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:msup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    minimization and gamma analysis. Validation was performed using a mouse collimator and PMMA slabs. Relative dose distributions and cumulative dose-volume histograms were computed in a CT-based voxelised mouse, with and without bolus.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The optimized FLASH source model features a dual-peak energy spectrum with a PW-dependent energy component (7.0\u20137.8 MeV for 0.5\u20135\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mi>\u03bc<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    s) and low-energy component probability. In conventional mode, a two-component spectrum (1.5\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    1.0 and 6.8\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    1.5 MeV) was used. Simulations showed good agreement with measurements (gamma-index 2 mm\/2% and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mo>&lt;<\/mml:mo>\n                          <mml:mn>5<\/mml:mn>\n                          <mml:mi mathvariant=\"normal\">%<\/mml:mi>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    differences for\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>R<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mn>50<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ,\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>R<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mn>90<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    and\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>R<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mi>p<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ). Differences in the mouse lung volume receiving at least 95% of the maximum dose (V95\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mi>lung<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) were 1% across FLASH PWs, increasing to 5% and 12% in CONV without and with bolus, respectively. Bolus increased V95\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mi>lung<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    in FLASH by 17%, indicating improved target coverage.\n                    <jats:italic>Significance.<\/jats:italic>\n                    A GATE 10 MC-based source model of the ElectronFLASH LINAC was developed for both UHDR (PW-dependent) and conventional modes. Despite PW-dependent energy variations, no significant dosimetric differences were observed between PWs in FLASH in the preclinical mouse model. The model provides a reliable tool for optimization of preclinical irradiation setups for FLASH biological studies in the absence of a treatment planning system.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/aea8c4","type":"journal-article","created":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T22:56:03Z","timestamp":1789599363000},"page":"195015","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Pulse width\u2013dependent Monte Carlo source modeling for ultra-high dose rate electron beams"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-6396-0708","authenticated-orcid":true,"given":"\u00c1ngela","family":"Henao Isaza","sequence":"first","affiliation":[{"name":"Carrer dels Til.lers s\/n"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"software","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4300-7064","authenticated-orcid":true,"given":"Iv\u00e1n","family":"L\u00f3pez Paz","sequence":"additional","affiliation":[{"name":"Carrer dels Til.lers s\/n"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0174-7451","authenticated-orcid":false,"given":"Consuelo","family":"Guardiola","sequence":"additional","affiliation":[{"name":"Carrer dels Til.lers s\/n"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-9574-918X","authenticated-orcid":false,"given":"Johan","family":"Sebasti\u00e1n Moreno","sequence":"additional","affiliation":[{"name":"PSL Research University"},{"name":"Cuidad Universitaria"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"software","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3132-1803","authenticated-orcid":false,"given":"Sophie","family":"Heinrich","sequence":"additional","affiliation":[{"name":"PSL Research University"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]}],"member":"266","published-online":{"date-parts":[[2026,10,1]]},"reference":[{"key":"pmbaea8c4bib1","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.nima.2016.06.125","type":"journal-article","article-title":"Recent developments in Geant4","volume":"835","author":"Allison","year":"2016"},{"key":"pmbaea8c4bib2","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1002\/mp.14226","type":"journal-article","article-title":"Report on G4-med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group","volume":"48","author":"Arce","year":"2021","journal-title":"Med. Phys."},{"key":"pmbaea8c4bib3","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1259\/0007-1285-42-494-102","type":"journal-article","article-title":"Survival of mammalian cells exposed to x rays at ultra-high dose-rates","volume":"42","author":"Berry","year":"1969","journal-title":"Br. J. Radiol."},{"key":"pmbaea8c4bib4","doi-asserted-by":"publisher","first-page":"1224","DOI":"10.1002\/mp.17492","type":"journal-article","article-title":"Monte Carlo modeling of a commercial machine and experimental setup for FLASH-minibeam irradiations with electrons","volume":"52","author":"Bonfrate","year":"2025","journal-title":"Med. Phys."},{"key":"pmbaea8c4bib5","doi-asserted-by":"publisher","first-page":"1974","DOI":"10.1118\/1.1500403","type":"journal-article","article-title":"Suppression of dark current radiation in step-and-shoot intensity modulated radiation therapy by the initial pulse-forming network","volume":"29","author":"Cheng","year":"2002","journal-title":"Med. Phys."},{"key":"pmbaea8c4bib6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2025.105014","type":"journal-article","article-title":"Commissioning and performance evaluation of the new electron UHDR FLASHKNiFE\u00ae system for flash radiation therapy","volume":"135","author":"Colnot","year":"2025","journal-title":"Phys. Medica"},{"key":"pmbaea8c4bib7","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad69fc","type":"journal-article","article-title":"Commissioning an ultra-high-dose-rate electron linac with end-to-end tests","volume":"69","author":"Dai","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"pmbaea8c4bib8","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-06101-x","type":"journal-article","article-title":"Unraveling the effects of FLASH and conventional irradiation on retinal pigment epithelial cells: in vitro and in vivo studies","volume":"15","author":"Di Marco","year":"2025","journal-title":"Sci. Rep."},{"key":"pmbaea8c4bib9","doi-asserted-by":"publisher","DOI":"10.3389\/fphy.2020.570697","type":"journal-article","article-title":"FLASH radiotherapy with electrons: Issues related to the production, monitoring and dosimetric characterization of the beam","volume":"8","author":"Di Martino","year":"2020","journal-title":"Front. Phys."},{"key":"pmbaea8c4bib10","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevAccelBeams.24.050102","type":"journal-article","article-title":"Compact S-band linear accelerator system for ultrafast, ultrahigh dose-rate radiotherapy","volume":"24","author":"Faillace","year":"2021","journal-title":"Phys. Rev. Accel. Beams"},{"key":"pmbaea8c4bib11","doi-asserted-by":"publisher","first-page":"245ra93","DOI":"10.1126\/scitranslmed.3008973","type":"journal-article","article-title":"Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice","volume":"6","author":"Favaudon","year":"2014","journal-title":"Sci. Transl. Med."},{"key":"pmbaea8c4bib12","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","type":"journal-article","article-title":"3D Slicer as an image computing platform for the quantitative imaging network","volume":"30","author":"Fedorov","year":"2012","journal-title":"Magn. Reson. Imaging"},{"key":"pmbaea8c4bib13","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1080\/09553007414551221","type":"journal-article","article-title":"Effects of dose-rate on the radiation response of rat skin","volume":"26","author":"Field","year":"1974","journal-title":"Int. J. Radiat. Biol."},{"key":"pmbaea8c4bib14","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.radonc.2021.11.004","type":"journal-article","article-title":"First demonstration of the FLASH effect with ultrahigh dose rate high-energy x-rays","volume":"166","author":"Gao","year":"2022","journal-title":"Radiother. Oncol."},{"key":"pmbaea8c4bib15","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2024.1373453","type":"journal-article","article-title":"Electron FLASH radiotherapy in vivo studies. a systematic review","volume":"14","author":"Giannini","year":"2024","journal-title":"Front. Oncol."},{"key":"pmbaea8c4bib16","doi-asserted-by":"publisher","first-page":"631","DOI":"10.3390\/app13010631","type":"journal-article","article-title":"Characterization of ultra-high-dose rate electron beams with electronFlash linac","volume":"13","author":"Giuliano","year":"2023","journal-title":"Appl. Sci."},{"key":"pmbaea8c4bib17","article-title":"Radiation dosimetry: electron beams with energies between 1 and 50 MeV","author":"ICRU","year":"1984","type":"other"},{"key":"pmbaea8c4bib18","doi-asserted-by":"crossref","DOI":"10.61092\/iaea.ve7q-y94k","type":"other","article-title":"Absorbed dose determination in external beam radiotherapy","author":"International Atomic Energy Agency","year":"2024"},{"key":"pmbaea8c4bib19","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1002\/mp.12066","type":"journal-article","article-title":"High dose-per-pulse electron beam dosimetry: usability and dose-rate independence of ebt3 gafchromic films","volume":"44","author":"Jaccard","year":"2017","journal-title":"Med. Phys."},{"key":"pmbaea8c4bib20","doi-asserted-by":"publisher","DOI":"10.48550\/arXiv.2403.00700","type":"journal-article","article-title":"Characteristics of dark current from an S-band rf gun with exchangeable photocathode system","author":"Jackson","year":"2024"},{"key":"pmbaea8c4bib21","doi-asserted-by":"publisher","DOI":"10.4224\/40001303","type":"software","article-title":"EGSnrc toolkit for Monte Carlo simulation of ionizing radiation transport","author":"Kawrakow","year":"2000","unstructured":"Kawrakow I Rogers D Mainegra-Hing E Tessier F Townson R Walters B 2000 EGSnrc toolkit for Monte Carlo simulation of ionizing radiation transport 10.4224\/40001303"},{"key":"pmbaea8c4bib22","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ae237c","type":"journal-article","article-title":"Gate 10 Monte Carlo particle transport simulation: II. architecture and innovations","volume":"71","author":"Krah","year":"2026","journal-title":"Phys. Med. Biol."},{"key":"pmbaea8c4bib23","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.radonc.2019.01.031","type":"journal-article","article-title":"Modifying a clinical linear accelerator for delivery of ultra-high dose rate irradiation","volume":"139","author":"Lempart","year":"2019","journal-title":"Radiother. Oncol."},{"key":"pmbaea8c4bib24","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1118\/1.598248","type":"journal-article","article-title":"A technique for the quantitative evaluation of dose distributions","volume":"25","author":"Low","year":"1998","journal-title":"Med. Phys."},{"key":"pmbaea8c4bib25","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acead0","type":"journal-article","article-title":"A diamond detector based dosimetric system for instantaneous dose rate measurements in FLASH electron beams","volume":"68","author":"Marinelli","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"pmbaea8c4bib26","doi-asserted-by":"publisher","DOI":"10.48550\/arXiv.1705.02363","type":"journal-article","article-title":"Dark current and radiation shielding studies for the ILC main linac","author":"Mokhov","year":"2017"},{"key":"pmbaea8c4bib27","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.radonc.2017.05.003","type":"journal-article","article-title":"Irradiation in a flash: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy\/s","volume":"124","author":"Montay-Gruel","year":"2017","journal-title":"Radiother. Oncol."},{"key":"pmbaea8c4bib28","doi-asserted-by":"publisher","first-page":"S32","DOI":"10.1016\/j.ijrobp.2021.07.099","type":"journal-article","article-title":"Feasibility of clinically practical ultra-high dose rate (FLASH) radiation delivery by a reversible configuration of a standard clinical-use linear accelerator","volume":"111","author":"No","year":"2021","journal-title":"Int, J. Radiat. Oncol."},{"key":"pmbaea8c4bib29","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1002\/mp.17483","type":"journal-article","article-title":"On the acceptance, commissioning, and quality assurance of electron FLASH units","volume":"52","author":"Palmiero","year":"2025","journal-title":"Med. Phys."},{"key":"pmbaea8c4bib30","article-title":"Current software versions","author":"PTW Freiburg GmbH n.d.","year":"2026","type":"other"},{"key":"pmbaea8c4bib31","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1118\/1.597552","type":"journal-article","article-title":"Beam: a Monte Carlo code to simulate radiotherapy treatment units","volume":"22","author":"Rogers","year":"1995","journal-title":"Med. Phys."},{"key":"pmbaea8c4bib32","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac8c83","type":"journal-article","article-title":"The openGATE ecosystem for Monte Carlo simulation in medical physics","volume":"67","author":"Sarrut","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"pmbaea8c4bib33","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ae237b","type":"journal-article","article-title":"Gate 10 Monte Carlo particle transport simulation: I. development and new features","volume":"71","author":"Sarrut","year":"2026","journal-title":"Phys. Med. Biol."},{"key":"pmbaea8c4bib34","doi-asserted-by":"publisher","DOI":"10.1118\/1.4871617","type":"journal-article","article-title":"A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications","volume":"41","author":"Sarrut","year":"2014","journal-title":"Med. Phys."},{"key":"pmbaea8c4bib35","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1002\/acm2.13059","type":"journal-article","article-title":"The quantification and potential impact of dark current on treatments with an MR guided radiotherapy (MRgRT) system","volume":"21","author":"Shepard","year":"2020","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"pmbaea8c4bib36","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1667\/RADE-20-00090","type":"journal-article","article-title":"FLASH irradiation results in reduced severe skin toxicity compared to conventional-dose-rate irradiation","volume":"194","author":"Soto","year":"2020","journal-title":"Radiat. Res."},{"key":"pmbaea8c4bib37","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1016\/j.ijrobp.2021.11.020","type":"journal-article","article-title":"Ultra-high dose rate (FLASH) carbon ion irradiation: dosimetry and first cell experiments","volume":"112","author":"Tinganelli","year":"2022","journal-title":"Int. J. Radiat. Oncol."},{"key":"pmbaea8c4bib38","doi-asserted-by":"publisher","first-page":"2121","DOI":"10.3390\/cancers15072121","type":"journal-article","article-title":"Independent reproduction of the FLASH effect on the gastrointestinal tract: A multi-institutional comparative study","volume":"15","author":"Vald\u00e9s Zayas","year":"2023","journal-title":"Cancers"},{"key":"pmbaea8c4bib39","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1158\/1078-0432.CCR-17-3375","type":"journal-article","article-title":"The advantage of FLASH radiotherapy confirmed in mini-pig and cat-cancer patients","volume":"25","author":"Vozenin","year":"2019","journal-title":"Clin. Cancer Res."},{"key":"pmbaea8c4bib40","doi-asserted-by":"publisher","DOI":"10.1103\/RevModPhys.96.035002","type":"journal-article","article-title":"FLASH: New intersection of physics, chemistry, biology and cancer medicine","volume":"96","author":"Vozenin","year":"2024","journal-title":"Rev. Mod. Phys."},{"key":"pmbaea8c4bib41","doi-asserted-by":"publisher","first-page":"S139","DOI":"10.1016\/j.ijrobp.2021.07.314","type":"journal-article","article-title":"Validation of a novel cone-less set-up for electron FLASH radiation delivery on a clinical-use linear accelerator","volume":"111","author":"Wu","year":"2021","journal-title":"Int. J. Radiat. Oncol."},{"key":"pmbaea8c4bib42","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1667\/RADE-20-00068.1","type":"journal-article","article-title":"FLASH investigations using protons: design of delivery system, preclinical setup and confirmation of FLASH effect with protons in animal systems","volume":"194","author":"Zhang","year":"2020","journal-title":"Radiat. Res."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T07:09:16Z","timestamp":1790838556000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aea8c4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,1]]},"references-count":42,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,10,1]]},"published-print":{"date-parts":[[2026,10,14]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/aea8c4","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,1]]},"assertion":[{"value":"Pulse width\u2013dependent Monte Carlo source modeling for ultra-high dose rate electron beams","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-11","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-10-01","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}