{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T14:32:47Z","timestamp":1793197967290,"version":"4.5.0"},"reference-count":21,"publisher":"IOP Publishing","issue":"20","license":[{"start":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T00:00:00Z","timestamp":1793145600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T00:00:00Z","timestamp":1793145600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Phys. Med. Biol."],"published-print":{"date-parts":[[2026,10,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Quantitative preclinical positron emission tomography (PET) imaging plays an important role in translational research, yet variability across scanners, sites, and analysis workflows remains a major barrier to robust multi-centre studies. In this work, we developed and evaluated a harmonisation framework across a national network of preclinical PET facilities.\n                    <jats:italic>Approach.<\/jats:italic>\n                    Six identical National Electrical Manufacturers Association (NEMA) NU 4-2008 image quality phantoms were manufactured and distributed to six sites, where they were imaged using local acquisition and reconstruction protocols across multiple scanner platforms.\n                    <jats:italic>Main Results.<\/jats:italic>\n                    Substantial variability in contrast recovery, uniformity, and spill-over ratios was observed under site-specific conditions. Centralised automated re-analysis produced only minor reductions in variability, indicating that inter-user effects were relatively small, compared to site-specific protocol variations. In contrast, optimisation of reconstruction parameters led to a marked reduction in inter-scanner variability (an average of 60% reduction across larger rods), particularly for voxel-wise maximum contrast recovery coefficients (CRC\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msubsup>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mtext>max<\/mml:mtext>\n                            <\/mml:mrow>\n                            <mml:mrow>\n                              <mml:mtext>vox<\/mml:mtext>\n                            <\/mml:mrow>\n                          <\/mml:msubsup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ), which are more sensitive to noise and reconstruction settings than the standard axial averaging NEMA CRC metric. Following harmonisation, the variability of CRC\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msubsup>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mtext>max<\/mml:mtext>\n                            <\/mml:mrow>\n                            <mml:mrow>\n                              <mml:mtext>vox<\/mml:mtext>\n                            <\/mml:mrow>\n                          <\/mml:msubsup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    approached and was lower that of conventional axial-averaged NEMA analysis (CRC\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msubsup>\n                            <mml:mi\/>\n                            <mml:mrow>\n                              <mml:mtext>max<\/mml:mtext>\n                            <\/mml:mrow>\n                            <mml:mrow>\n                              <mml:mtext>avg<\/mml:mtext>\n                            <\/mml:mrow>\n                          <\/mml:msubsup>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ), with reductions ranging 7%\u201333% across the 1\u20135 mm rods, demonstrating improved quantitative consistency even at the voxel level.\n                    <jats:italic>Significance.<\/jats:italic>\n                    These findings show that scanner and site-specific protocol variations are the dominant factors for harmonisation in preclinical PET. By systematically evaluating acquisition, image reconstruction and analysis related sources of variability across a national network of heterogeneous preclinical PET systems, this work provides a practical framework for harmonisation. The proposed framework is conceptually aligned with clinical harmonisation initiatives such as EARL and provides a practical basis for the future development of harmonised performance ranges across preclinical scanners. This enables more reliable multi-centre studies and supports the use of quantitative, voxel-wise imaging biomarkers in translational research.\n                  <\/jats:p>","DOI":"10.1088\/1361-6560\/aeb46a","type":"journal-article","created":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T22:53:31Z","timestamp":1792018411000},"page":"205034","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A harmonisation framework for multi-centre preclinical PET imaging across a national research infrastructure"],"prefix":"10.1088","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0469-1972","authenticated-orcid":true,"given":"Georgios I","family":"Angelis","sequence":"first","affiliation":[{"name":"The University of Sydney"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary","family":"Cowin","sequence":"additional","affiliation":[{"name":"The University of Queensland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2904-2664","authenticated-orcid":true,"given":"Tzongtyng","family":"Hung","sequence":"additional","affiliation":[{"name":"University of New South Wales"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8384-2403","authenticated-orcid":false,"given":"Ingrid J G","family":"Burvenich","sequence":"additional","affiliation":[{"name":"Olivia Newton-John Cancer Research Institute"},{"name":"La Trobe University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"De Veer","sequence":"additional","affiliation":[{"name":"Monash University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4775-6943","authenticated-orcid":true,"given":"Kelly","family":"Smart","sequence":"additional","affiliation":[{"name":"Australian Nuclear Science and Technology Organisation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7161-9367","authenticated-orcid":false,"given":"Yaser H","family":"Gholami","sequence":"additional","affiliation":[{"name":"The University of Sydney"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0889-9052","authenticated-orcid":true,"given":"Karine","family":"Mardon","sequence":"additional","affiliation":[{"name":"The University of Queensland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Zahra","sequence":"additional","affiliation":[{"name":"Australian Nuclear Science and Technology Organisation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hasar","family":"Hamze","sequence":"additional","affiliation":[{"name":"Australian Nuclear Science and Technology Organisation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew M","family":"Scott","sequence":"additional","affiliation":[{"name":"Olivia Newton-John Cancer Research Institute"},{"name":"La Trobe University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7397-0364","authenticated-orcid":true,"given":"Steven R","family":"Meikle","sequence":"additional","affiliation":[{"name":"University of Sydney"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,10,28]]},"reference":[{"key":"pmbaeb46abib1","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s00259-017-3740-2","type":"journal-article","article-title":"EANM\/EARL harmonization strategies in PET quantification: from daily practice to multicentre oncological studies","volume":"44","author":"Aide","year":"2017","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbaeb46abib2","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s12149-022-01820-x","type":"journal-article","article-title":"A review of harmonization strategies for quantitative PET","volume":"37","author":"Akamatsu","year":"2023","journal-title":"Ann. Nucl. Med."},{"key":"pmbaeb46abib3","doi-asserted-by":"publisher","first-page":"1198","DOI":"10.2967\/jnumed.125.271665","type":"journal-article","article-title":"Pulling together: A 5-year plan to improve theranostic outcomes by improving the accuracy of dosimetry\u2014an FNIH joint academic, clinical and industrial collaboration","volume":"67","author":"Bailey","year":"2026","journal-title":"J. Nucl. Med."},{"key":"pmbaeb46abib4","doi-asserted-by":"publisher","first-page":"315","DOI":"10.2967\/jnumed.124.268578","type":"journal-article","article-title":"A method for validating PET and SPECT cameras for quantitative clinical imaging trials using novel radionuclides","volume":"66","author":"Bailey","year":"2025","journal-title":"J. Nucl. Med."},{"key":"pmbaeb46abib5","doi-asserted-by":"publisher","first-page":"73","DOI":"10.3390\/cells15010073","type":"journal-article","article-title":"Preclinical PET and SPECT imaging in small animals: technologies, challenges and translational impact","volume":"15","author":"Bruzgo-Grzybko","year":"2026","journal-title":"Cells"},{"key":"pmbaeb46abib6","doi-asserted-by":"publisher","first-page":"2885","DOI":"10.1088\/0031-9155\/54\/9\/020","type":"journal-article","article-title":"Performance evaluation of an Inveon PET preclinical scanner","volume":"54","author":"Constantinescu","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"pmbaeb46abib7","doi-asserted-by":"publisher","first-page":"755","DOI":"10.2967\/jnumed.120.258152","type":"journal-article","article-title":"The Australasian radiopharmaceutical trials network: clinical trials, evidence and opportunity","volume":"62","author":"Francis","year":"2021","journal-title":"J. Nucl. Med."},{"key":"pmbaeb46abib8","doi-asserted-by":"publisher","first-page":"1300","DOI":"10.2967\/jnumed.111.099382","type":"journal-article","article-title":"NEMA NU 4-2008 comparison of preclinical PET imaging systems","volume":"53","author":"Goertzen","year":"2012","journal-title":"J. Nucl. Med."},{"key":"pmbaeb46abib9","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aba08c","type":"journal-article","article-title":"Characterization of a preclinical PET insert in a 7 tesla MRI scanner: beyond NEMA testing","volume":"65","author":"Gsell","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbaeb46abib10","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1007\/s00259-017-3853-7","type":"journal-article","article-title":"EANM\/EARL FDG-PET\/CT accreditation - summary results from the first 200 accredited imaging systems","volume":"45","author":"Kaalep","year":"2018","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"pmbaeb46abib11","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1053\/j.semnuclmed.2023.03.001","type":"journal-article","article-title":"Preclinical research highlighting contemporary targeting mechanisms of radiolabelled compounds for PET based infection imaging","volume":"53","author":"Kleynhans","year":"2023","journal-title":"Semin. Nucl. Med."},{"key":"pmbaeb46abib12","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.2967\/jnumed.118.221994","type":"journal-article","article-title":"Reproducibility and comparability of preclinical PET imaging data: a multicenter small-animal PET study","volume":"60","author":"Mannheim","year":"2019","journal-title":"J. Nucl. Med."},{"key":"pmbaeb46abib13","doi-asserted-by":"publisher","first-page":"461","DOI":"10.2967\/jnumed.119.231308","type":"journal-article","article-title":"Standardization of preclinical PET\/CT imaging to improve quantitative accuracy, precision and reproducibility: a multicenter study","volume":"61","author":"McDougald","year":"2020","journal-title":"J. Nucl. Med."},{"key":"pmbaeb46abib14","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1088\/1361-6560\/ab8f71","type":"journal-article","article-title":"Small animal PET: a review of what we have done and where we are going","volume":"65","author":"Miyaoka","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"pmbaeb46abib15","article-title":"NEMA NU 4-2008: Performance Measurements of Small Animal Positron Emission Tomographs Technical report National Electrical Manufacturers Association Rosslyn","author":"National Electrical Manufacturers Association","year":"2008","type":"other"},{"key":"pmbaeb46abib16","doi-asserted-by":"publisher","first-page":"6446","DOI":"10.7150\/thno.100339","type":"journal-article","article-title":"Aspects and prospects of preclinical theranostic radiopharmaceutical development","volume":"14","author":"Nelson","year":"2024","journal-title":"Theranostics"},{"key":"pmbaeb46abib17","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1007\/s12149-020-01518-y","type":"journal-article","article-title":"Standardization of PET imaging and site qualification program by JSNM: Collaboration with EANM\/EANM","volume":"34","author":"Senda","year":"2020","journal-title":"Ann. Nucl. Med."},{"key":"pmbaeb46abib18","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1158\/0008-5472.CAN-20-0373","type":"journal-article","article-title":"Preclinical applications of multi-platform imaging in animal models of cancer","volume":"81","author":"Serkova","year":"2021","journal-title":"Cancer Res."},{"key":"pmbaeb46abib19","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.2967\/jnumed.124.269349","type":"journal-article","article-title":"Standardization of PET\/CT performance requirements for whole-body quantitative imaging: an international proposal","volume":"66","author":"Sunderland","year":"2025","journal-title":"J. Nucl. Med."},{"key":"pmbaeb46abib20","doi-asserted-by":"publisher","first-page":"1481","DOI":"10.1007\/s11095-022-03277-z","type":"journal-article","article-title":"PET imaging in preclinical anti-a \u03b2 drug development","volume":"39","author":"Syv\u00e4nen","year":"2022","journal-title":"Pharm. Res."},{"key":"pmbaeb46abib21","doi-asserted-by":"publisher","first-page":"1741","DOI":"10.2967\/jnumed.111.088260","type":"journal-article","article-title":"National electrical manufacturers association NU-4 performance evaluation of the PET component of the NanoPET\/CT preclinical PET\/CT scanner","volume":"52","author":"Szanda","year":"2011","journal-title":"J. Nucl. Med."}],"container-title":["Physics in Medicine &amp; Biology"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T13:46:49Z","timestamp":1793195209000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6560\/aeb46a"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,28]]},"references-count":21,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2026,10,28]]},"published-print":{"date-parts":[[2026,10,28]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6560\/aeb46a","relation":{},"ISSN":["0031-9155","1361-6560"],"issn-type":[{"value":"0031-9155","type":"print"},{"value":"1361-6560","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,28]]},"assertion":[{"value":"A harmonisation framework for multi-centre preclinical PET imaging across a national research infrastructure","name":"article_title","label":"Article Title"},{"value":"Physics in Medicine & Biology","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-07-14","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-10-14","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-10-28","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}