{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T13:01:39Z","timestamp":1784984499577,"version":"3.55.0"},"reference-count":31,"publisher":"IOP Publishing","issue":"6","license":[{"start":{"date-parts":[[2017,5,22]],"date-time":"2017-05-22T00:00:00Z","timestamp":1495411200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2017,5,22]],"date-time":"2017-05-22T00:00:00Z","timestamp":1495411200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2017,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Normal fluid status (dry weight) can be identified by hydration markers established in the healthy population. The general population average could be influenced by age with its accompanying physiological changes and\/or illness. The aims of this study were (1) to evaluate the effect of age and systolic blood pressure (SBP) on these markers; (2) to compare mean values of hydration markers as assessed by different bioimpedance techniques.<\/jats:p>\n                  <jats:p>\n                    Subjects from the general population (\n                    <jats:italic>n<\/jats:italic>\n                    \u2009\u2009=\u2009\u2009212, males 105, 57.1% White, 31.6% Black, and 11.3% others) were studied. Body weight, height and SBP were measured. Whole body and calf bioimpedance (Hydra 4200) methods were utilized with subjects in the supine position. Calf normalized resistivity (CNR), fluid overload (FO), extracellular (ECV) and intracellular (ICV) volume measurements ECV\/total body water (TBW) were calculated. Subjects were stratified by age; young (Group1): 18\u201335 years; middle (Group2): 36\u201360 years, senior (Group3): 61\u201380 years.\n                  <\/jats:p>\n                  <jats:p>\n                    Body mass index (BMI), CNR, and ECV\/TBW differed significantly between age groups, and genders. ECV and FO increased with age in males. Decreased CNR (indicating relative increased fluid load) (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009\u2009&lt;\u2009\u20090.001) and increased SBP (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009\u2009&lt;\u2009\u20090.001) were associated with age in all three groups. CNR in Group1 was the same as in 36.0% of subjects in Group2 and 12.5% of subjects in Group3. In those subjects in Group2 and Group3, with CNR levels comparable to Group1 subjects, SBP was lower than in their peers in each respective age group.\n                  <\/jats:p>\n                  <jats:p>In conclusion average CNR in Group1 represents the range of healthy subjects. Since CNR is correlated with age, subjects in Group2 and Group3 are more likely to have fluid overload. Although about a third of subjects in Group2 and Group3 were in the range of Group1, the age and associated factors should be considered when CNR is used to identify fluid status in senior patients.<\/jats:p>","DOI":"10.1088\/1361-6579\/aa6912","type":"journal-article","created":{"date-parts":[[2017,5,22]],"date-time":"2017-05-22T07:14:57Z","timestamp":1495437297000},"page":"1289-1300","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["Effect of age and blood pressure on determination of normal fluid status in a general population using whole body and calf bioimpedance techniques"],"prefix":"10.1088","volume":"38","author":[{"given":"Fansan","family":"Zhu","sequence":"first","affiliation":[{"name":"Renal Research Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samer R","family":"Abbas","sequence":"additional","affiliation":[{"name":"Renal Research Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Kotanko","sequence":"additional","affiliation":[{"name":"Renal Research Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathan W","family":"Levin","sequence":"additional","affiliation":[{"name":"Renal Research Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2017,5,22]]},"reference":[{"key":"pmeaaa6912bib001","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1159\/000356830","type":"journal-article","article-title":"Comparison of bioimpedance techniques to detect changes in fluid status in hemodialysis patients","volume":"37","author":"Abbas","year":"2014","journal-title":"Blood Purif."},{"key":"pmeaaa6912bib002","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1053\/j.jrn.2014.10.014","type":"journal-article","article-title":"Bioimpedance can solve problems of fluid overload","volume":"25","author":"Abbas","year":"2015","journal-title":"J. Renal Nutrition"},{"key":"pmeaaa6912bib003","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1152\/jappl.1998.84.1.257","type":"journal-article","article-title":"Does adipose tissue influence bioelectric impedance in obese men and women?","volume":"84","author":"Baumgartner","year":"1998","journal-title":"J. Appl. Physiol."},{"key":"pmeaaa6912bib004","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1177\/039139880703001210","type":"journal-article","article-title":"Integration of blood volume, blood pressure, heart rate and bioimpedance monitoring for the achievement of optimal dry body weight during chronic hemodialysis","volume":"30","author":"Bonello","year":"2007","journal-title":"Int. J. Artif. Organs"},{"key":"pmeaaa6912bib005","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1093\/ajcn\/85.1.80","type":"journal-article","article-title":"A whole-body model to distinguish excess fluid from the hydration of major body tissues","volume":"85","author":"Chamney","year":"2007","journal-title":"Am. J. Clin. Nutr."},{"key":"pmeaaa6912bib006","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1111\/j.1542-4758.2007.00148.x","type":"journal-article","article-title":"Fluid balance, dry weight, and blood pressure in dialysis","volume":"11","author":"Charra","year":"2007","journal-title":"Hemodial Int."},{"key":"pmeaaa6912bib007","doi-asserted-by":"publisher","first-page":"1542","DOI":"10.1152\/jappl.1997.82.5.1542","type":"journal-article","article-title":"Predicting body cell mass with bioimpedance by using theoretical methods: a technological review","volume":"82","author":"De Lorenzo","year":"1997","journal-title":"J. Appl. Physiol."},{"key":"pmeaaa6912bib008","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1556\/APhysiol.98.2011.2.2","type":"journal-article","article-title":"The importance of body composition and dry weight assessments in patients with chronic kidney disease","volume":"98","author":"Dolgos","year":"2011","journal-title":"Acta Physiol. Hung."},{"key":"pmeaaa6912bib009","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1111\/j.1525-139X.2012.01095.x","type":"journal-article","article-title":"Assessment of extracellular fluid volume and fluid status in hemodialysis patients: current status and technical advances","volume":"25","author":"Dou","year":"2012","journal-title":"Semin. Dial."},{"key":"pmeaaa6912bib010","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/S0272-6386(96)90309-1","type":"journal-article","article-title":"Role of volume overload in dialysis-refractory hypertension","volume":"28","author":"Fishbane","year":"1996","journal-title":"Am. J. Kidney Dis."},{"key":"pmeaaa6912bib011","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1681\/ASN.V102392","type":"journal-article","article-title":"Assessment of dry weight in hemodialysis: an overview","volume":"10","author":"Jaeger","year":"1999","journal-title":"J. Am. Soc. Nephrol."},{"key":"pmeaaa6912bib012","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1093\/ndt\/gfm889","type":"journal-article","article-title":"Current state of bioimpedance technologies in dialysis","volume":"23","author":"Kotanko","year":"2008","journal-title":"Nephrol. Dial. Transplant."},{"key":"pmeaaa6912bib013","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1097\/01.mnh.0000185983.48319.00","type":"journal-article","article-title":"Bioimpedance, dry weight and blood pressure control: new methods and consequences","volume":"14","author":"Kuhlmann","year":"2005","journal-title":"Curr. Opin. Nephrol. Hypertension"},{"key":"pmeaaa6912bib014","first-page":"38","type":"conference-proceedings","article-title":"Association between home blood pressure and body composition by bioimpedance monitoring in patients undergoing peritoneal dialysis","volume":"vol 31","author":"Kurasawa","year":"2015"},{"key":"pmeaaa6912bib015","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1177\/039139880202500803","type":"journal-article","article-title":"Age-related extracellular to total body water volume ratio (Ecv\/TBW)\u2014can it be used for \u2018dry weight\u2019 determination in dialysis patients? Application of multifrequency bioimpedance measurement","volume":"25","author":"Lopot","year":"2002","journal-title":"Int. J. Artif. Organs"},{"key":"pmeaaa6912bib016","doi-asserted-by":"publisher","first-page":"1801","DOI":"10.1152\/jappl.1998.84.5.1801","type":"journal-article","article-title":"Analytic assessment of the various bioimpedance methods used to estimate body water","volume":"84","author":"Matthie","year":"1998","journal-title":"J. Appl. Physiol."},{"key":"pmeaaa6912bib017","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1152\/japplphysiol.00145.2005","type":"journal-article","article-title":"Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy","volume":"99","author":"Matthie","year":"2005","journal-title":"J. Appl. Physiol."},{"key":"pmeaaa6912bib018","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1177\/0884533614568155","type":"journal-article","article-title":"Bioimpedance at the bedside: current applications, limitations, and opportunities","volume":"30","author":"Mulasi","year":"2015","journal-title":"Nutr. Clin. Pract."},{"key":"pmeaaa6912bib019","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1111\/j.1523-1755.1998.00843.x","type":"journal-article","article-title":"Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis. The Italian hemodialysis-bioelectrical impedance analysis (HD-BIA) Study Group","volume":"53","author":"Piccoli","year":"1998","journal-title":"Kidney Int."},{"key":"pmeaaa6912bib020","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1111\/j.1542-4758.2008.00302.x","type":"journal-article","article-title":"A fresh look at dry weight","volume":"12","author":"Raimann","year":"2008","journal-title":"Hemodial Int."},{"key":"pmeaaa6912bib021","doi-asserted-by":"publisher","first-page":"S314","DOI":"10.1007\/s00592-003-0096-9","type":"journal-article","article-title":"Body composition of aboriginal Australian women: comparison with age-matched Caucasians","volume":"40","author":"Raja","year":"2003","journal-title":"Acta Diabetol."},{"key":"pmeaaa6912bib022","doi-asserted-by":"publisher","first-page":"376","DOI":"10.5414\/CN107078","type":"journal-article","article-title":"Bioimpedance-based volume at clinical target weight is contracted in hemodialysis patients with a high body mass index","volume":"77","author":"Ribitsch","year":"2012","journal-title":"Clin. Nephrol."},{"key":"pmeaaa6912bib023","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1159\/000167012","type":"journal-article","article-title":"Bioimpedance analysis in dialysis: state of the art and what we can expect","volume":"27","author":"Tattersall","year":"2009","journal-title":"Blood Purif."},{"key":"pmeaaa6912bib024","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1089\/lrb.2010.0014","type":"journal-article","article-title":"Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy","volume":"9","author":"Ward","year":"2011","journal-title":"Lymphatic Res. Biol."},{"key":"pmeaaa6912bib025","doi-asserted-by":"publisher","first-page":"2169","DOI":"10.1007\/s00467-013-2540-6","type":"journal-article","article-title":"Hydration measurement by bioimpedance spectroscopy and blood pressure management in children on hemodialysis","volume":"28","author":"Zaloszyc","year":"2013","journal-title":"Pediatric Nephrol."},{"key":"pmeaaa6912bib026","doi-asserted-by":"publisher","first-page":"e7","DOI":"10.1016\/j.jcrc.2015.03.025","type":"journal-article","article-title":"Associations of fluid overload with mortality and kidney recovery in patients with acute kidney injury: a systematic review and meta-analysis","volume":"30","author":"Zhang","year":"2015","journal-title":"J. Crit. Care"},{"key":"pmeaaa6912bib027","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1088\/0967-3334\/32\/7\/S12","type":"journal-article","article-title":"Estimation of normal hydration in dialysis patients using whole body and calf bioimpedance analysis","volume":"32","author":"Zhu","year":"2011","journal-title":"Physiol. Meas."},{"key":"pmeaaa6912bib028","doi-asserted-by":"publisher","first-page":"S503","DOI":"10.1088\/0967-3334\/29\/6\/S42","type":"journal-article","article-title":"A method for the estimation of hydration state during hemodialysis using a calf bioimpedance technique","volume":"29","author":"Zhu","year":"2008a","journal-title":"Physiol. Meas."},{"key":"pmeaaa6912bib029","doi-asserted-by":"publisher","first-page":"S491","DOI":"10.1088\/0967-3334\/29\/6\/S41","type":"journal-article","article-title":"Extracellular fluid redistribution during hemodialysis: bioimpedance measurement and model","volume":"29","author":"Zhu","year":"2008b","journal-title":"Physiol. Meas."},{"key":"pmeaaa6912bib030","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1159\/000368937","type":"journal-article","article-title":"Estimation of body composition and normal fluid status using a calf bioimpedance technique","volume":"39","author":"Zhu","year":"2015","journal-title":"Blood Purif."},{"key":"pmeaaa6912bib031","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1097\/MNH.0000000000000273","type":"journal-article","article-title":"Techniques for assessing fluids status in patients with kidney disease","volume":"25","author":"Zhu","year":"2016","journal-title":"Curr. Opin. Nephrol. Hypertension"}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0967-3334\/38\/i=6\/a=1289\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/38\/i=6\/a=1289?key=crossref.71dd249dee35dc1881beea6ef4c83061","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aa6912","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aa6912\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aa6912\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/38\/i=6\/a=1289\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/38\/i=6\/a=1289?key=crossref.71dd249dee35dc1881beea6ef4c83061","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aa6912\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T12:26:02Z","timestamp":1784982362000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aa6912"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,22]]},"references-count":31,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2017,5,22]]},"published-print":{"date-parts":[[2017,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/aa6912","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,22]]},"assertion":[{"value":"Effect of age and blood pressure on determination of normal fluid status in a general population using whole body and calf bioimpedance techniques","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2017 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2016-11-30","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2017-03-24","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2017-05-22","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}