{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T13:05:31Z","timestamp":1779541531062,"version":"3.53.1"},"reference-count":24,"publisher":"IOP Publishing","issue":"9","license":[{"start":{"date-parts":[[2018,9,12]],"date-time":"2018-09-12T00:00:00Z","timestamp":1536710400000},"content-version":"vor","delay-in-days":11,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2018,9,12]],"date-time":"2018-09-12T00:00:00Z","timestamp":1536710400000},"content-version":"tdm","delay-in-days":11,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2018,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    : This study employs a recently developed experimental technique for comparison of the flow characteristics and the effectiveness of gas washout between pressure control ventilation (PCV) and high-frequency percussive ventilation (HFPV) in high-compliance and low-compliance\n                    <jats:italic>ex vivo<\/jats:italic>\n                    porcine respiratory tracts.\n                    <jats:italic>Approach<\/jats:italic>\n                    : The\n                    <jats:italic>ex vivo<\/jats:italic>\n                    porcine lungs are filled with nitrogen prior to ventilating with atmospheric gas using either PCV or HFPV to investigate the flow characteristics and gas washout characteristics. The study considered freshly removed lungs from porcine carcasses that were humanely harvested for human consumption. Subsequently, the porcine lungs were exposed externally to formalin to simulate low-compliance conditions. The first order models of respiratory mechanics were employed to predict the lung compliance and resistance in normal and formalin exposed lungs. HFPV was operated in two different modes based upon the set pressures, namely HFPV-Low and HFPV-High. The peak pressures of HFPV and PCV were matched in HFPV-Low and the peak pressures are increased to about 20\u201330% in the HFPV-High mode.\n                    <jats:italic>Main results<\/jats:italic>\n                    : Both HFPV-Low and HFPV-High mode deliver smaller tidal volume (\n                    <jats:italic>V<\/jats:italic>\n                    <jats:sub>T<\/jats:sub>\n                    ) as compared to PCV in high and compliance states (about 70% and 40% for healthy and formalin treated lungs, repsectively). Although the tidal volume delivered by HFPV-High and HFPV-Low are comparable, they reveal a substantial difference in washout time as well as total ventilation volumes. In a high compliant lung (healthy lung), HFPV-High washes out the nitrogen within the lung more rapidly, whereas HFPV-Low washes out the inert gas more slowly as compared to PCV. In a low-compliance lung, HFPV-Low delivers similar washout rates as PCV at a much smaller\n                    <jats:italic>V<\/jats:italic>\n                    <jats:sub>T<\/jats:sub>\n                    and lower mean airway pressure.\n                    <jats:italic>Significance<\/jats:italic>\n                    : The\n                    <jats:italic>ex vivo<\/jats:italic>\n                    study supports the hypothesis that in low compliant lungs HFPV provides effective washout with a protective ventilation.\n                  <\/jats:p>","DOI":"10.1088\/1361-6579\/aada73","type":"journal-article","created":{"date-parts":[[2018,8,15]],"date-time":"2018-08-15T11:15:14Z","timestamp":1534331714000},"page":"095003","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of pressure, volume and gas washout characteristics between PCV and HFPV in healthy and formalin fixed\n                    <i>ex vivo<\/i>\n                    porcine lungs"],"prefix":"10.1088","volume":"39","author":[{"given":"Rabijit","family":"Dutta","sequence":"first","affiliation":[{"name":"University of Idaho"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tao","family":"Xing","sequence":"additional","affiliation":[{"name":"University of Idaho"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gordon K","family":"Murdoch","sequence":"additional","affiliation":[{"name":"University of Idaho"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2018,9,12]]},"reference":[{"key":"pmeaaada73bib001","doi-asserted-by":"crossref","first-page":"734","DOI":"10.4187\/respcare.10550734","type":"journal-article","article-title":"High-frequency percussive ventilation: pneumotachograph validation and tidal volume analysis","volume":"55","author":"Allan","year":"2010","journal-title":"Respir. Care"},{"key":"pmeaaada73bib002","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","type":"journal-article","article-title":"Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome","volume":"342","author":"ARDS Network","year":"2000","journal-title":"New Engl. J. Med."},{"key":"pmeaaada73bib003","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1164\/rccm.200710-1589OC","type":"journal-article","article-title":"Lung stress and strain during mechanical ventilation for acute respiratory distress syndrome","volume":"178","author":"Chiumello","year":"2008","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"pmeaaada73bib004","doi-asserted-by":"publisher","first-page":"1970","DOI":"10.1097\/CCM.0b013e3181eb9d0b","type":"journal-article","article-title":"High-frequency percussive ventilation and low tidal volume ventilation in burns: a randomized controlled trial","volume":"38","author":"Chung","year":"2010","journal-title":"Crit. Care Med."},{"key":"pmeaaada73bib005","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1097\/00005373-198903000-00012","type":"journal-article","article-title":"High-frequency percussive ventilation in patients with inhalation injury","volume":"29","author":"Cioffi","year":"1989","journal-title":"J. Trauma Acute Care Surg."},{"key":"pmeaaada73bib006","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1152\/jappl.1988.64.2.823","type":"journal-article","article-title":"Human respiratory input impedance from 4 to 200 Hz: physiological and modeling considerations","volume":"64","author":"Dorkin","year":"1988","journal-title":"J. Appl. Physiol."},{"key":"pmeaaada73bib007","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1164\/ajrccm.157.1.9604014","type":"journal-article","article-title":"Ventilator-induced lung injury: lessons from experimental studies","volume":"157","author":"Dreyfuss","year":"1998","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"pmeaaada73bib008","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/aaaaa2","type":"journal-article","article-title":"Comparison of flow and gas washout characteristics between pressure control and high-frequency percussive ventilation using a test lung","volume":"39","author":"Dutta","year":"2018","journal-title":"Physiol. Meas."},{"key":"pmeaaada73bib009","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1183\/1025448x.10000412","type":"book","article-title":"Ventilator strategies in severe hypoxaemic respiratory failure","author":"Esan","year":"2012"},{"key":"pmeaaada73bib010","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1097\/00005373-198703000-00002","type":"journal-article","article-title":"The role of high-frequency ventilation in post-traumatic respiratory insufficiency","volume":"27","author":"Hurst","year":"1987","journal-title":"J. Trauma Acute Care Surg."},{"key":"pmeaaada73bib011","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1007\/BF02368321","type":"journal-article","article-title":"Assessment of time-domain analyses for estimation of low-frequency respiratory mechanical properties and impedance spectra","volume":"23","author":"Kaczka","year":"1995","journal-title":"Ann. Biomed. Eng."},{"key":"pmeaaada73bib012","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/aa5a31","type":"journal-article","article-title":"Differences in respiratory mechanics estimation with respect to manoeuvres and mathematical models","volume":"3","author":"Kretschmer","year":"2017","journal-title":"Biomed. Phys. Eng. Express"},{"key":"pmeaaada73bib013","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1097\/00075198-199606000-00014","type":"journal-article","article-title":"Smoke inhalation is a multilevel insult to the pulmonary system","volume":"2","author":"Lentz","year":"1996","journal-title":"Curr. Opin. Crit. Care"},{"key":"pmeaaada73bib014","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.resp.2005.02.015","type":"journal-article","article-title":"Mechanical loads modulate tidal volume and lung washout during high-frequency percussive ventilation","volume":"150","author":"Lucangelo","year":"2006a","journal-title":"Respir. Physiol. Neurobiol."},{"key":"pmeaaada73bib015","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.resp.2004.04.005","type":"journal-article","article-title":"Effects of mechanical load on flow, volume and pressure delivered by high-frequency percussive ventilation","volume":"142","author":"Lucangelo","year":"2004","journal-title":"Respir. Physiol. Neurobiol."},{"key":"pmeaaada73bib016","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1093\/bja\/ael026","type":"journal-article","article-title":"High-frequency percussive ventilation during surgical bronchial repair in a patient with one lung","volume":"96","author":"Lucangelo","year":"2006b","journal-title":"Br. J. Anaesth."},{"key":"pmeaaada73bib017","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1097\/MAT.0000000000000196","type":"journal-article","article-title":"Use of HFPV for adults with ARDS: the protocolized use of high-frequency percussive ventilation for adults with acute respiratory failure treated with extracorporeal membrane oxygenation","volume":"61","author":"Michaels","year":"2015","journal-title":"ASAIO J."},{"key":"pmeaaada73bib018","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/S0305-4179(02)00051-7","type":"journal-article","article-title":"High frequency percussive ventilation and conventional ventilation after smoke inhalation: a randomised study","volume":"28","author":"Reper","year":"2002","journal-title":"Burns"},{"key":"pmeaaada73bib019","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1088\/0967-3334\/32\/6\/002","type":"journal-article","article-title":"In vitro measurements of respiratory mechanics during HFPV using a mechanical lung model","volume":"32","author":"Riscica","year":"2011","journal-title":"Physiol. Meas."},{"key":"pmeaaada73bib0019a","first-page":"53","type":"journal-article","article-title":"Damping of the dynamic pressure amplitude in the ventilatory circuit during high-frequency oscillatory ventilation","volume":"57","author":"Ro\u017e\u00e1nek","year":"2012","journal-title":"Biomedical Engineering"},{"key":"pmeaaada73bib020","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1088\/0967-3334\/35\/3\/383","type":"journal-article","article-title":"Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation","volume":"35","author":"Schranz","year":"2014","journal-title":"Physiol. Meas."},{"key":"pmeaaada73bib021","doi-asserted-by":"publisher","first-page":"1306","DOI":"10.1016\/j.chest.2017.06.025","type":"journal-article","article-title":"High-frequency oscillatory ventilation in adults with ARDS: past, present, and future","volume":"152","author":"Sklar","year":"2017","journal-title":"Chest"},{"key":"pmeaaada73bib0021a","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.jcrc.2016.03.004","type":"journal-article","article-title":"Pressure attenuation during high-frequency airway clearance therapy across different size endotracheal tubes: an","volume":"34","author":"Smallwood","year":"2016","journal-title":"in vitro study J. Crit. Care"},{"key":"pmeaaada73bib022","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1378\/chest.116.2.440","type":"journal-article","article-title":"High-frequency percussive ventilation improves oxygenation in patients with ARDS","volume":"116","author":"Velmahos","year":"1999","journal-title":"CHEST J."}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"http:\/\/stacks.iop.org\/0967-3334\/39\/i=9\/a=095003?key=crossref.bee874d4c07a506d3162d75936b983d7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/39\/i=9\/a=095003\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/39\/i=9\/a=095003\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/stacks.iop.org\/0967-3334\/39\/i=9\/a=095003?key=crossref.bee874d4c07a506d3162d75936b983d7","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T12:19:17Z","timestamp":1779538757000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/aada73"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,1]]},"references-count":24,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2018,9,12]]},"published-print":{"date-parts":[[2018,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/aada73","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,1]]},"assertion":[{"value":"Comparison of pressure, volume and gas washout characteristics between PCV and HFPV in healthy and formalin fixed\n                      ex vivo\n                      porcine lungs","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2018 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2018-05-19","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2018-08-15","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2018-09-12","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}