{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T17:55:26Z","timestamp":1787162126559,"version":"build-2736575974"},"reference-count":32,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2021,3,5]],"date-time":"2021-03-05T00:00:00Z","timestamp":1614902400000},"content-version":"vor","delay-in-days":32,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,3,5]],"date-time":"2021-03-05T00:00:00Z","timestamp":1614902400000},"content-version":"tdm","delay-in-days":32,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2021,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . This work explored the reliability of using points on the heart sounds envelope as indicators of the opening and closure of the aortic valve (AVO, AVC) to measure the pre-ejection period (PEP) and the left ventricular ejection time (LVET).\n                    <jats:italic>Approach.<\/jats:italic>\n                    36 phonocardiograms (PCGs) from healthy subjects and cardiovascular disease subjects were denoised using single-channel independent component analysis (SCICA) and, from the Hilbert envelopes, the positions of the S1 and S2 peaks were detected (pS1, pS2). Complementarily, the positions of the local maxima of S1 and S2 (mS1, mS2) and the points surrounding pS1 and pS2 (tS1, tS2) were obtained. Finally, the reliability of these points (and the corresponding PEP and LVET intervals) was evaluated by the calculation of three error indexes (\n                    <jats:italic>ePEP<\/jats:italic>\n                    ,\n                    <jats:italic>eLVET,<\/jats:italic>\n                    and\n                    <jats:italic>score<\/jats:italic>\n                    ) and by comparison to reference annotations provided by echocardiography using the Bland\u2013Altman analysis and the paired\n                    <jats:italic>T<\/jats:italic>\n                    -test.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The results indicated that, from a total of 920 and 341 heartbeats in the healthy and diseased groups, respectively, the timing points given by pS1 and pS2 (or mS1 and mS2) were unlikely to substitute for the reference annotations and, thus, are unreliable for measuring the PEP and LVET intervals in the PCG. The t-points evaluation, on the other hand, indicated that tS1 was likely to substitute for AVO and was thus reliable for measuring the PEP using the PCG, with median and interquartile ranges of 0.3(8.3) ms and \u22120.2(7.5) ms for each group. Future work will generate an envelope with higher temporal resolution, from where tS1 and tS2 can be more accurately detected to improve the PEP and LVET measurements on a larger dataset.\n                    <jats:italic>Significance.<\/jats:italic>\n                    The statistical tests revealed that the envelope of S1 is suitable for extracting a timing point from which the pre-ejection interval can be reliably quantified, and discarded the local maximum used in other studies.\n                  <\/jats:p>","DOI":"10.1088\/1361-6579\/abe0fe","type":"journal-article","created":{"date-parts":[[2021,1,28]],"date-time":"2021-01-28T17:36:55Z","timestamp":1611855415000},"page":"025004","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Timing the opening and closure of the aortic valve using a phonocardiogram envelope: a performance test for systolic time intervals measurement"],"prefix":"10.1088","volume":"42","author":[{"given":"A\u00edda","family":"Jim\u00e9nez-Gonz\u00e1lez","sequence":"first","affiliation":[{"name":"Universidad Aut\u00f3noma Metropolitana-Iztapalapa"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2021,3,5]]},"reference":[{"key":"pmeaabe0febib1","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","type":"journal-article","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"pmeaabe0febib2","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/0167-2789(86)90031-X","type":"journal-article","article-title":"Extracting qualitative dynamics from experimental data","volume":"20","author":"Broomhead","year":"1986","journal-title":"Physica. D"},{"key":"pmeaabe0febib3","author":"Call for SC - ICBHI 2019","year":"2019","type":"web-resource"},{"key":"pmeaabe0febib4","doi-asserted-by":"publisher","first-page":"1941","DOI":"10.1109\/ICASSP.1998.681443","type":"conference-proceedings","article-title":"Multidimensional independent component analysis","volume":"4","author":"Cardoso","year":"1998"},{"key":"pmeaabe0febib5","doi-asserted-by":"publisher","first-page":"3124","DOI":"10.1109\/IEMBS.2009.5332565","type":"conference-proceedings","article-title":"Assessing systolic time-intervals from heart sound: a feasibility study","author":"Carvalho","year":"2009"},{"key":"pmeaabe0febib6","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1109\/IEMBS.2010.5626642","type":"conference-proceedings","article-title":"Comparison of systolic time interval measurement modalities for portable devices","author":"Carvalho","year":"2010"},{"key":"pmeaabe0febib7","doi-asserted-by":"publisher","first-page":"1819","DOI":"10.1016\/j.sigpro.2007.01.011","type":"journal-article","article-title":"Source separation using single channel ICA","volume":"87","author":"Davies","year":"2007","journal-title":"Signal Process."},{"key":"pmeaabe0febib8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fphys.2019.01057","type":"journal-article","article-title":"Comparison of different methods for estimating cardiac timings: a comprehensive multimodal echocardiography investigation","volume":"10","author":"Dehkordi","year":"2019","journal-title":"Frontiers in Physiology"},{"key":"pmeaabe0febib9","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.cardfail.2008.03.011","type":"journal-article","article-title":"Computerized acoustic cardiographic electromechanical activation time correlates with invasive and echocardiographic parameters of left ventricular contractility","volume":"14","author":"Efstratiadis","year":"2008","journal-title":"J. Cardiac Failure"},{"key":"pmeaabe0febib10","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/0028-2243(86)90162-0","type":"journal-article","article-title":"The measurement of fetal systolic time intervals: lessons from ultrasound","volume":"23","author":"Fleming","year":"1986","journal-title":"European Journal of Obstetrics and Gynecology and Reproductive Biology"},{"key":"pmeaabe0febib11","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1136\/pgmj.59.693.423","type":"journal-article","article-title":"Systolic time intervals: a review of the method in the non-invasive investigation of cardiac function in health, disease and clinical pharmacology","volume":"59","author":"Hassan","year":"1983","journal-title":"Postgraduate Medical Journal"},{"key":"pmeaabe0febib12","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.1162\/neco.1997.9.7.1483","type":"journal-article","article-title":"A fast fixed-point algorithm for Independent Component Analysis","volume":"9","author":"Hyv\u00e4rinen","year":"1997","journal-title":"Neural Comput."},{"key":"pmeaabe0febib13","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1016\/S0893-6080(00)00026-5","type":"journal-article","article-title":"Independent component analysis: algorithms and applications","volume":"13","author":"Hyv\u00e4rinen","year":"2000","journal-title":"Neural Netw."},{"key":"pmeaabe0febib14","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/BF02442475","type":"journal-article","article-title":"Algorithm for detecting the first and the second heart sounds by spectral tracking","volume":"18","author":"Iwata","year":"1980","journal-title":"Med. Biol. Eng. Comput."},{"key":"pmeaabe0febib15","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/978-3-030-30636-6","type":"conference-proceedings","article-title":"Quantification of systolic time intervals using continuous wavelet transform of electrocardiogram and phonocardiogram signals","author":"Janjarasjitt","year":"2020"},{"key":"pmeaabe0febib16","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.bspc.2019.101836","type":"journal-article","article-title":"Blind extraction of fetal and maternal components from the abdominal electrocardiogram: an ICA implementation for low-dimensional recordings","volume":"58","author":"Jim\u00e9nez-Gonz\u00e1lez","year":"2020","journal-title":"Biomed. Signal Process. Control"},{"key":"pmeaabe0febib17","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1007\/s11517-009-0474-8","type":"journal-article","article-title":"Extracting sources from noisy abdominal phonograms: a single-channel blind source separation method","volume":"47","author":"Jim\u00e9nez-Gonz\u00e1lez","year":"2009","journal-title":"Med. Biol. Eng. Comput."},{"key":"pmeaabe0febib18","doi-asserted-by":"publisher","first-page":"2322","DOI":"10.1109\/TBME.2010.2051226","type":"journal-article","article-title":"Time-structure based reconstruction of physiological independent sources extracted from noisy abdominal phonograms.","volume":"57","author":"Jim\u00e9nez-Gonz\u00e1lez","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaabe0febib19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1117\/12.2035520","type":"conference-proceedings","article-title":"Blind separation of multiple physiological sources from a single-channel recording: a preprocessing approach for antenatal surveillances","author":"Jim\u00e9nez-Gonz\u00e1lez","year":"2013"},{"key":"pmeaabe0febib20","author":"Klein","year":"2021","type":"web-resource"},{"key":"pmeaabe0febib21","doi-asserted-by":"publisher","first-page":"2033","DOI":"10.3390\/s20072033","type":"journal-article","article-title":"Wearable cardiorespiratory monitoring employing a multimodal digital patch stethoscope: estimation of ecg, pep, lvetand respiration using a 55 mm single-lead ecg and phonocardiogram","volume":"20","author":"Klum","year":"2020","journal-title":"Sensors (Switzerland)"},{"key":"pmeaabe0febib22","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1161\/01.CIR.47.5.1006","type":"journal-article","article-title":"Temporal relation of the first heart sound to closure of the mitral valve","volume":"47","author":"Laniado","year":"1973","journal-title":"Circulation"},{"key":"pmeaabe0febib23","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1161\/01.CIR.56.2.146","type":"journal-article","article-title":"Reviews of contemporary laboratory methods: a critical review of the systolic time intervals","volume":"56","author":"Lewis","year":"1977","journal-title":"Circulation"},{"key":"pmeaabe0febib24","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/0002-8703(58)90054-1","type":"journal-article","article-title":"On the mechanism of production of the heart sounds","volume":"55","author":"Luisada","year":"1958","journal-title":"Am. Heart J."},{"key":"pmeaabe0febib25","doi-asserted-by":"publisher","first-page":"3129","DOI":"10.1109\/IEMBS.2009.5332572","type":"conference-proceedings","article-title":"Assessing PEP and LVET from heart sounds: algorithms and evaluation","author":"Paiva","year":"2009"},{"key":"pmeaabe0febib26","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1088\/0967-3334\/33\/2\/177","type":"journal-article","article-title":"Beat-to-beat systolic time-interval measurement from heart sounds and ECG","volume":"33","author":"Paiva","year":"2012","journal-title":"Physiol. Meas."},{"key":"pmeaabe0febib27","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1136\/hrt.19.4.473","type":"journal-article","article-title":"Relation of the first and second heart sounds to events in the cardiac cycle","volume":"19","author":"Reinhold","year":"1957","journal-title":"British Heart Journal"},{"key":"pmeaabe0febib28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/j.1469-8986.1990.tb02171.x","type":"journal-article","article-title":"Methodological guidelines for impedance cardiography","volume":"27","author":"Sherwood","year":"1990","journal-title":"Psychophysiology"},{"key":"pmeaabe0febib29","doi-asserted-by":"publisher","first-page":"64","DOI":"10.3390\/vibration2010005","type":"journal-article","article-title":"Recent advances in seismocardiography","volume":"2","author":"Taebi","year":"2019","journal-title":"Vibration"},{"key":"pmeaabe0febib30","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1161\/01.CIR.7.3.321","type":"journal-article","article-title":"Ballistocardiography: the normal ballistocardiogram","volume":"VII","author":"Thompson","year":"1953","journal-title":"Circulation,"},{"key":"pmeaabe0febib31","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1109\/JSEN.2016.2643780","type":"journal-article","article-title":"Wearable sensing of cardiac timing intervals from cardiogenic limb vibration signals","volume":"17","author":"Wiens","year":"2016","journal-title":"IEEE Sens J."},{"key":"pmeaabe0febib32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/ams2.483","type":"journal-article","article-title":"New non-invasive approach to detect cardiac contractility using the first sound of phonocardiogram","volume":"7","author":"Yamashita","year":"2020","journal-title":"Acute Medicine & Surgery"}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:20:38Z","timestamp":1778779238000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/abe0fe"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,1]]},"references-count":32,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2021,3,5]]},"published-print":{"date-parts":[[2021,2,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/abe0fe","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,1]]},"assertion":[{"value":"Timing the opening and closure of the aortic valve using a phonocardiogram envelope: a performance test for systolic time intervals measurement","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-08-22","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-01-28","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-03-05","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}