{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T01:30:18Z","timestamp":1793410218967,"version":"4.5.0"},"reference-count":29,"publisher":"IOP Publishing","issue":"9","license":[{"start":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T00:00:00Z","timestamp":1662681600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T00:00:00Z","timestamp":1662681600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"German Ministry for Education and Research","award":["13FH628IX6"],"award-info":[{"award-number":["13FH628IX6"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["52077216"],"award-info":[{"award-number":["52077216"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2022,9,30]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    The present study evaluates the influence of different thorax contours (generic versus individual) on the parameter \u2018silent spaces\u2019 computed from electrical impedance tomography (EIT) measurements.\n                    <jats:italic>Approach.<\/jats:italic>\n                    Six patients with acute respiratory distress syndrome were analyzed retrospectively. EIT measurements were performed and the silent spaces were calculated based on (1) patient-specific contours S\n                    <jats:sub>ind<\/jats:sub>\n                    , (2) generic adult male contours S\n                    <jats:sub>EidorsA<\/jats:sub>\n                    and (3) generic neonate contours S\n                    <jats:sub>EidorsN<\/jats:sub>\n                    .\n                    <jats:italic>Main results.<\/jats:italic>\n                    The differences among all studied subjects were 5\u00a0\u00b1\u00a06% and 8\u00a0\u00b1\u00a07% for S\n                    <jats:sub>ind<\/jats:sub>\n                    versus S\n                    <jats:sub>EidorsA<\/jats:sub>\n                    , S\n                    <jats:sub>ind<\/jats:sub>\n                    versus S\n                    <jats:sub>EidorsN<\/jats:sub>\n                    , respectively (median\u00a0\u00b1\u00a0interquartile range). S\n                    <jats:sub>ind<\/jats:sub>\n                    values were higher than the generic ones in two patients.\n                    <jats:italic>Significance.<\/jats:italic>\n                    In the present study, we demonstrated the differences in values when the silent spaces were calculated based on different body and organ contours. To our knowledge, this study was the first one showing explicitly that silent spaces calculated with generic thorax and lung contours might lead to results with different locations and values as compared to the calculation with subject-specific models. Interpretations of silent spaces should be proceeded with caution.\n                  <\/jats:p>","DOI":"10.1088\/1361-6579\/ac8bc2","type":"journal-article","created":{"date-parts":[[2022,8,22]],"date-time":"2022-08-22T18:24:42Z","timestamp":1661192682000},"page":"09NT02","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":9,"title":["The calculation of electrical impedance tomography based silent spaces requires individual thorax and lung contours"],"prefix":"10.1088","volume":"43","author":[{"given":"Lin","family":"Yang","sequence":"first","affiliation":[{"name":"Fourth Military Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4286-5227","authenticated-orcid":false,"given":"Feng","family":"Fu","sequence":"additional","affiliation":[{"name":"Fourth Military Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7712-6539","authenticated-orcid":false,"given":"In\u00e9z","family":"Frerichs","sequence":"additional","affiliation":[{"name":"University Medical Centre of Schleswig-Holstein Campus Kiel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Knut","family":"M\u00f6ller","sequence":"additional","affiliation":[{"name":"Furtwangen University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meng","family":"Dai","sequence":"additional","affiliation":[{"name":"Fourth Military Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1279-2207","authenticated-orcid":false,"given":"Zhanqi","family":"Zhao","sequence":"additional","affiliation":[{"name":"Fourth Military Medical University"},{"name":"Furtwangen University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2022,9,9]]},"reference":[{"key":"pmeaac8bc2bib1","doi-asserted-by":"publisher","first-page":"S35","DOI":"10.1088\/0967-3334\/30\/6\/S03","type":"journal-article","article-title":"GREIT: a unified approach to 2D linear EIT reconstruction of lung images","volume":"30","author":"Adler","year":"2009","journal-title":"Physiol. Meas."},{"key":"pmeaac8bc2bib2","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1088\/0967-3334\/27\/5\/S03","type":"journal-article","article-title":"Uses and abuses of EIDORS: an extensible software base for EIT","volume":"27","author":"Adler","year":"2006","journal-title":"Physiol. Meas."},{"key":"pmeaac8bc2bib3","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1007\/s00134-009-1447-y","type":"journal-article","article-title":"Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography","volume":"35","author":"Costa","year":"2009","journal-title":"Intensive Care Med."},{"key":"pmeaac8bc2bib4","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.23736\/S0375-9393.20.14130-0","type":"journal-article","article-title":"Dynamic bedside assessment of the physiologic effects of prone position in acute respiratory distress syndrome patients by electrical impedance tomography","volume":"86","author":"Dalla Corte","year":"2020","journal-title":"Minerva Anestesiologica"},{"key":"pmeaac8bc2bib5","doi-asserted-by":"publisher","first-page":"3000","DOI":"10.1109\/TBME.2012.2209116","type":"journal-article","article-title":"Toward morphological thoracic EIT: major signal sources correspond to respective organ locations in CT","volume":"59","author":"Ferrario","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaac8bc2bib6","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","type":"journal-article","article-title":"Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group","volume":"72","author":"Frerichs","year":"2017","journal-title":"Thorax"},{"key":"pmeaac8bc2bib7","doi-asserted-by":"publisher","first-page":"054001","DOI":"10.1088\/1361-6579\/ab1946","type":"journal-article","article-title":"Chest electrical impedance tomography measures in neonatology and paediatrics-a survey on clinical usefulness","volume":"40","author":"Frerichs","year":"2019","journal-title":"Physiol. Meas."},{"key":"pmeaac8bc2bib8","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1111\/j.1399-6576.1998.tb05308.x","type":"journal-article","article-title":"Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography","volume":"42","author":"Frerichs","year":"1998","journal-title":"Acta Anaesthesiol. Scand."},{"key":"pmeaac8bc2bib9","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1109\/TMI.2012.2200904","type":"journal-article","article-title":"Impact of model shape mismatch on reconstruction quality in electrical impedance tomography","volume":"31","author":"Grychtol","year":"2012","journal-title":"IEEE Trans. Med. Imaging"},{"key":"pmeaac8bc2bib10","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1186\/s13054-020-03301-x","type":"journal-article","article-title":"Influence of overdistension\/recruitment induced by high positive end-expiratory pressure on ventilation-perfusion matching assessed by electrical impedance tomography with saline bolus","volume":"24","author":"He","year":"2020","journal-title":"Crit Care"},{"key":"pmeaac8bc2bib11","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1186\/s13613-021-00921-6","type":"journal-article","article-title":"Three broad classifications of acute respiratory failure etiologies based on regional ventilation and perfusion by electrical impedance tomography: a hypothesis-generating study","volume":"11","author":"He","year":"2021","journal-title":"Ann Intensive Care"},{"key":"pmeaac8bc2bib12","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1378\/chest.124.1.314","type":"journal-article","article-title":"Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs","volume":"124","author":"Hinz","year":"2003","journal-title":"Chest"},{"key":"pmeaac8bc2bib13","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.jcrc.2016.04.028","type":"journal-article","article-title":"Electrical impedance tomography in adult patients undergoing mechanical ventilation: a systematic review","volume":"35","author":"Kobylianskii","year":"2016","journal-title":"Journal of Critical Care"},{"key":"pmeaac8bc2bib14","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1164\/rccm.201607-1370LE","type":"journal-article","article-title":"Individualized multiplanar electrical impedance tomography in infants to optimize lung monitoring","volume":"195","author":"Miedema","year":"2017","journal-title":"American Journal of Respiratory and Critical Care Medicine"},{"key":"pmeaac8bc2bib15","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.jcrc.2019.06.009","type":"journal-article","article-title":"Aeration changes induced by high flow nasal cannula are more homogeneous than those generated by non-invasive ventilation in healthy subjects","volume":"53","author":"P\u00e9rez-Ter\u00e1n","year":"2019","journal-title":"Journal of Critical Care"},{"key":"pmeaac8bc2bib16","doi-asserted-by":"publisher","first-page":"R82","DOI":"10.1186\/cc7900","type":"journal-article","article-title":"Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study","volume":"13","author":"Richard","year":"2009","journal-title":"Crit Care"},{"key":"pmeaac8bc2bib17","doi-asserted-by":"publisher","first-page":"110626","DOI":"10.1016\/j.jclinane.2021.110626","type":"journal-article","article-title":"Evaluation of atelectasis using electrical impedance tomography during procedural deep sedation for MRI in small children: a prospective observational trial","volume":"77","author":"Riva","year":"2021","journal-title":"J. Clin. Anesth."},{"key":"pmeaac8bc2bib18","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1097\/CCM.0000000000004439","type":"journal-article","article-title":"Personalized positive end-expiratory pressure in acute respiratory distress syndrome: comparison between optimal distribution of regional ventilation and positive transpulmonary pressure","volume":"48","author":"Scaramuzzo","year":"2020","journal-title":"Critical Care Medicine"},{"key":"pmeaac8bc2bib19","doi-asserted-by":"publisher","first-page":"25951","DOI":"10.1038\/srep25951","type":"journal-article","article-title":"Structural-functional lung imaging using a combined CT-EIT and a discrete cosine transformation reconstruction method","volume":"6","author":"Schullcke","year":"2016","journal-title":"Sci. Rep."},{"key":"pmeaac8bc2bib20","doi-asserted-by":"publisher","first-page":"2752","DOI":"10.1109\/TBME.2021.3053463","type":"journal-article","article-title":"Model selection based algorithm in neonatal chest EIT","volume":"68","author":"Seifnaraghi","year":"2021","journal-title":"IEEE Transactions on Bio-Medical Engineering"},{"key":"pmeaac8bc2bib21","doi-asserted-by":"publisher","first-page":"035003","DOI":"10.1088\/1361-6579\/ab7b42","type":"journal-article","article-title":"Effect of sternal electrode gap and belt rotation on the robustness of pulmonary electrical impedance tomography parameters","volume":"41","author":"Sophocleous","year":"2020","journal-title":"Physiol. Meas."},{"key":"pmeaac8bc2bib22","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s13054-017-1931-7","type":"journal-article","article-title":"Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment","volume":"22","author":"Spadaro","year":"2018","journal-title":"Crit Care"},{"key":"pmeaac8bc2bib23","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1186\/s13054-021-03615-4","type":"journal-article","article-title":"Unmatched ventilation and perfusion measured by electrical impedance tomography predicts the outcome of ARDS","volume":"25","author":"Spinelli","year":"2021","journal-title":"Critical Care"},{"key":"pmeaac8bc2bib24","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1093\/bja\/aew188","type":"journal-article","article-title":"Perioperative assessment of regional ventilation during changing body positions and ventilation conditions by electrical impedance tomography","volume":"117","author":"Ukere","year":"2016","journal-title":"Br. J. Anaesth."},{"key":"pmeaac8bc2bib25","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1097\/MCC.0000000000000789","type":"journal-article","article-title":"Bedside noninvasive monitoring of mechanically ventilated patients","volume":"27","author":"Via","year":"2021","journal-title":"Current Opinion in Critical Care"},{"key":"pmeaac8bc2bib26","doi-asserted-by":"publisher","first-page":"1209","DOI":"10.21037\/qims-20-682","type":"journal-article","article-title":"Lung regions identified with CT improve the value of global inhomogeneity index measured with electrical impedance tomography","volume":"11","author":"Yang","year":"2021","journal-title":"Quantitative Imaging in Medicine and Surgery"},{"key":"pmeaac8bc2bib27","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.1088\/0967-3334\/35\/6\/1083","type":"journal-article","article-title":"The influence of image reconstruction algorithms on linear thorax EIT image analysis of ventilation","volume":"35","author":"Zhao","year":"2014","journal-title":"Physiol. Meas."},{"key":"pmeaac8bc2bib28","doi-asserted-by":"publisher","first-page":"171","DOI":"10.3233\/XST-2010-0252","type":"journal-article","article-title":"A lung area estimation method for analysis of ventilation inhomogeneity based on electrical impedance tomography","volume":"18","author":"Zhao","year":"2010","journal-title":"J. Xray Sci. Technol."},{"key":"pmeaac8bc2bib29","doi-asserted-by":"publisher","first-page":"01NT","DOI":"10.1088\/1361-6579\/aa9eb4","type":"journal-article","article-title":"Comparison of different functional EIT approaches to quantify tidal ventilation distribution","volume":"39","author":"Zhao","year":"2018","journal-title":"Physiol. Meas."}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:06:18Z","timestamp":1778778378000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ac8bc2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,9]]},"references-count":29,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2022,9,9]]},"published-print":{"date-parts":[[2022,9,30]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/ac8bc2","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,9]]},"assertion":[{"value":"The calculation of electrical impedance tomography based silent spaces requires individual thorax and lung contours","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2022-04-29","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-08-22","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-09-09","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}