{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:17:37Z","timestamp":1778779057574,"version":"3.51.4"},"reference-count":94,"publisher":"IOP Publishing","issue":"11","license":[{"start":{"date-parts":[[2023,11,6]],"date-time":"2023-11-06T00:00:00Z","timestamp":1699228800000},"content-version":"vor","delay-in-days":5,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,11,6]],"date-time":"2023-11-06T00:00:00Z","timestamp":1699228800000},"content-version":"tdm","delay-in-days":5,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100013301","name":"Parkinson\u2019s Foundation","doi-asserted-by":"crossref","award":["PF-CRA-2073"],"award-info":[{"award-number":["PF-CRA-2073"]}],"id":[{"id":"10.13039\/100013301","id-type":"DOI","asserted-by":"crossref"}]},{"name":"DANU Sports Ltd","award":["120162"],"award-info":[{"award-number":["120162"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2023,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . Gait assessments have traditionally been analysed in laboratory settings, but this may not reflect natural gait. Wearable technology may offer an alternative due to its versatility. The purpose of the study was to establish the validity and reliability of temporal gait outcomes calculated by the DANU sports system, against a 3D motion capture reference system.\n                    <jats:italic>Approach<\/jats:italic>\n                    . Forty-one healthy adults (26 M, 15 F, age 36.4 \u00b1 11.8 years) completed a series of overground walking and jogging trials and 60 s treadmill walking and running trials at various speeds (8\u201314 km hr\n                    <jats:sup>\u22121<\/jats:sup>\n                    ), participants returned for a second testing session to repeat the same testing.\n                    <jats:italic>Main results<\/jats:italic>\n                    . For validity, 1406 steps and 613 trials during overground and across all treadmill trials were analysed respectively. Temporal outcomes generated by the DANU sports system included ground contact time, swing time and stride time all demonstrated excellent agreement compared to the laboratory reference (intraclass correlation coefficient (ICC) &gt; 0.900), aside from ground contact time during overground jogging which had good agreement (ICC = 0.778). For reliability, 666 overground and 511 treadmill trials across all speeds were examined. Test re-test agreement was excellent for all outcomes across treadmill trials (ICC &gt; 0.900), except for swing time during treadmill walking which had good agreement (ICC = 0.886). Overground trials demonstrated moderate to good test re-test agreement (ICC = 0.672\u20130.750), which may be due to inherent variability of self-selected (rather than treadmill set) pacing between sessions.\n                    <jats:italic>Significance<\/jats:italic>\n                    . Overall, this study showed that temporal gait outcomes from the DANU Sports System had good to excellent validity and moderate to excellent reliability in healthy adults compared to an established laboratory reference.\n                  <\/jats:p>","DOI":"10.1088\/1361-6579\/ad04b4","type":"journal-article","created":{"date-parts":[[2023,10,18]],"date-time":"2023-10-18T18:47:41Z","timestamp":1697654861000},"page":"115001","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":10,"title":["Validity and reliability of the DANU sports system for walking and running gait assessment"],"prefix":"10.1088","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5087-1969","authenticated-orcid":false,"given":"Rachel","family":"Mason","sequence":"first","affiliation":[{"name":"Northumbria University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4886-920X","authenticated-orcid":false,"given":"Gillian","family":"Barry","sequence":"additional","affiliation":[{"name":"Northumbria University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hugh","family":"Robinson","sequence":"additional","affiliation":[{"name":"DANU Sports Ltd, Dublin,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5550-6901","authenticated-orcid":false,"given":"Ben","family":"O\u2019Callaghan","sequence":"additional","affiliation":[{"name":"DANU Sports Ltd, Dublin,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oisin","family":"Lennon","sequence":"additional","affiliation":[{"name":"DANU Sports Ltd, Dublin,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4049-9291","authenticated-orcid":false,"given":"Alan","family":"Godfrey","sequence":"additional","affiliation":[{"name":"Northumbria University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6846-9372","authenticated-orcid":false,"given":"Samuel","family":"Stuart","sequence":"additional","affiliation":[{"name":"Northumbria University"},{"name":"Oregon Health and Science University"},{"name":"Northumbria Healthcare NHS Foundation Trust, North Shields,"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2023,11,6]]},"reference":[{"key":"pmeaad04b4bib1","doi-asserted-by":"publisher","first-page":"938","DOI":"10.3109\/09638288.2013.833312","type":"journal-article","article-title":"Effect of postural balance training on gait parameters in children with cerebral palsy","volume":"93","author":"Abd El-Kafy","year":"2014","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"pmeaad04b4bib2","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/S0021-9290(02)00008-8","type":"journal-article","article-title":"Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes","volume":"35","author":"Aminian","year":"2002","journal-title":"J. Biomech."},{"key":"pmeaad04b4bib3","doi-asserted-by":"publisher","first-page":"3604","DOI":"10.3390\/s18113604","type":"journal-article","article-title":"Context impacts in accelerometer-based walk detection and step counting","volume":"18","author":"Ao","year":"2018","journal-title":"Sensors"},{"key":"pmeaad04b4bib4","doi-asserted-by":"publisher","first-page":"24","DOI":"10.5220\/0005656500240033","type":"journal-article","article-title":"Measuring temporal parameters of gait with foot mounted IMUs in steady state running","volume":"1","author":"Bailey","year":"2015","journal-title":"Proceedings of the 3rd International Congress on Sport Sciences Research and Technology Support"},{"key":"pmeaad04b4bib5","first-page":"560","type":"journal-article","article-title":"Gait analysis: clinical facts","volume":"52","author":"Baker","year":"2016","journal-title":"Eur. J. Phys. Rehabil. Med."},{"key":"pmeaad04b4bib6","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.3390\/s19071483","type":"journal-article","article-title":"Automated accelerometer-based gait event detection during multiple running conditions","volume":"19","author":"Benson","year":"2019","journal-title":"Sensors"},{"key":"pmeaad04b4bib7","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.gaitpost.2018.04.047","type":"journal-article","article-title":"The use of wearable devices for walking and running gait analysis outside of the lab: a systematic review","volume":"63","author":"Benson","year":"2018","journal-title":"Gait & Posture"},{"key":"pmeaad04b4bib8","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","type":"journal-article","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland Jm","year":"1986","journal-title":"Lancet (London, England)"},{"key":"pmeaad04b4bib9","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1109\/MSP.2005.1550191","type":"journal-article","article-title":"Gait recognition: a challenging signal processing technology for biometric identification","volume":"22","author":"Boulgouris","year":"2005","journal-title":"IEEE Signal Process Mag."},{"key":"pmeaad04b4bib10","doi-asserted-by":"publisher","first-page":"3023","DOI":"10.1177\/0363546518793657","type":"journal-article","article-title":"Is there a pathological gait associated with common soft tissue running injuries?","volume":"46","author":"Bramah","year":"2018","journal-title":"Am. J. sports Med."},{"key":"pmeaad04b4bib11","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1186\/s13047-015-0111-8","type":"journal-article","article-title":"Validation and reliability testing of a new, fully integrated gait analysis insole","volume":"8","author":"Braun","year":"2015","journal-title":"J. Foot Ankle Res."},{"key":"pmeaad04b4bib12","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.cmpb.2012.02.003","type":"journal-article","article-title":"Estimation of spatial-temporal gait parameters in level walking based on a single accelerometer: validation on normal subjects by standard gait analysis","volume":"108","author":"Bugan\u00e9","year":"2012","journal-title":"Comput. Methods Programs Biomed."},{"key":"pmeaad04b4bib13","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1152\/japplphysiol.00374.2018","type":"journal-article","article-title":"Step frequency patterns of elite ultramarathon runners during a 100-km road race","volume":"126","author":"Burns","year":"2019","journal-title":"J. Appl. Physiol."},{"key":"pmeaad04b4bib14","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.medengphy.2020.11.005","type":"journal-article","article-title":"Gait analysis in neurological populations: progression in the use of wearables","volume":"87","author":"Celik","year":"2021","journal-title":"Med. Eng. Phys."},{"key":"pmeaad04b4bib15","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1123\/jab.17.1.77","type":"journal-article","article-title":"The variability in running gait caused by force plate targeting","volume":"17","author":"Challis","year":"2001","journal-title":"J. Appl. Biomech."},{"key":"pmeaad04b4bib16","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1007\/s00421-014-3072-x","type":"journal-article","article-title":"Shoe drop has opposite influence on running pattern when running overground or on a treadmill","volume":"115","author":"Chambon","year":"2015","journal-title":"Eur. J. Appl. Physiol."},{"key":"pmeaad04b4bib17","doi-asserted-by":"publisher","DOI":"10.3390\/medicina58111640","type":"journal-article","article-title":"Determination of the predictors with the greatest influence on walking in the elderly","volume":"58","author":"Chung","year":"2022","journal-title":"Medicina (Kaunas)"},{"key":"pmeaad04b4bib18","doi-asserted-by":"publisher","DOI":"10.3390\/s22041480","type":"journal-article","article-title":"Gait impairment in traumatic brain injury: a systematic review","volume":"22","author":"Dever","year":"2022","journal-title":"Sensors"},{"key":"pmeaad04b4bib19","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1080\/17461391.2013.783627","type":"journal-article","article-title":"Stride frequency in relation to oxygen consumption in experienced and novice runners","volume":"14","author":"de Ruiter","year":"2014","journal-title":"Eur. J. Sport Sci."},{"key":"pmeaad04b4bib20","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1001\/jamainternmed.2022.4000","type":"journal-article","article-title":"Prospective associations of daily step counts and intensity with cancer and cardiovascular disease incidence and mortality and all-cause mortality","volume":"182","author":"Del Pozo Cruz","year":"2022","journal-title":"JAMA Intern. Med."},{"key":"pmeaad04b4bib21","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.ptsp.2018.06.009","type":"journal-article","article-title":"Test-retest reliability of two-dimensional video analysis during running","volume":"33","author":"Dingenen","year":"2018","journal-title":"Phys. Ther. Sport."},{"key":"pmeaad04b4bib22","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s12984-016-0115-z","type":"journal-article","article-title":"Validity and reliability of a portable gait analysis system for measuring spatiotemporal gait characteristics: comparison to an instrumented treadmill","volume":"13","author":"Donath","year":"2016","journal-title":"Journal of neuroengineering and rehabilitation"},{"key":"pmeaad04b4bib23","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1016\/j.pmr.2005.02.007","type":"journal-article","article-title":"Biomechanics and analysis of running gait","volume":"16","author":"Dugan","year":"2005","journal-title":"Phys. Med. Rehabil Clin. N. Am."},{"key":"pmeaad04b4bib24","doi-asserted-by":"publisher","first-page":"610","DOI":"10.3389\/fphys.2018.00610","type":"journal-article","article-title":"Accurate estimation of running temporal parameters using foot-worn inertial sensors","volume":"9","author":"Falbriard","year":"2018","journal-title":"Front. Physiol."},{"key":"pmeaad04b4bib25","doi-asserted-by":"publisher","first-page":"5892","DOI":"10.1109\/EMBC.2014.6944969","type":"journal-article","article-title":"Within trial validation and reliability of a single tri-axial accelerometer for gait assessment","volume":"2014","author":"Godfrey","year":"2014","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"pmeaad04b4bib26","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-020-0260-4","type":"journal-article","article-title":"Verification, analytical validation, and clinical validation (V3): the foundation of determining fit-for-purpose for Biometric Monitoring Technologies (BioMeTs)","volume":"3","author":"Goldsack","year":"2020","journal-title":"npj Digital Med."},{"key":"pmeaad04b4bib27","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1515\/hukin-2015-0003","type":"journal-article","article-title":"Reproducibility and validity of the myotest for measuring step frequency and ground contact time in recreational runners","volume":"45","author":"Gouttebarge","year":"2015","journal-title":"J. Human Kinetics"},{"key":"pmeaad04b4bib28","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1007\/s004210100394","type":"journal-article","article-title":"Are variations in running economy in humans associated with ground reaction force characteristics?","volume":"84","author":"Heise","year":"2001","journal-title":"Eur. J. Appl. Physiol."},{"key":"pmeaad04b4bib29","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1016\/S0966-6362(03)00069-9","type":"journal-article","article-title":"Test-retest reliability of trunk accelerometric gait analysis","volume":"19","author":"Henriksen","year":"2004","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib30","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1249\/JSR.0b013e3181a6187a","type":"journal-article","article-title":"Methods of running gait analysis","volume":"8","author":"Higginson","year":"2009","journal-title":"Curr. Sports Med. Rep."},{"key":"pmeaad04b4bib31","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1249\/01.FIT.0000298459.30006.8d","type":"journal-article","article-title":"One-mile step count at walking and running speeds","volume":"12","author":"Hoeger","year":"2008","journal-title":"ACSM\u2019s Health Fitness J."},{"key":"pmeaad04b4bib32","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1080\/14763141.2019.1579366","type":"journal-article","article-title":"Running biomechanics as measured by wearable sensors: effects of speed and surface","volume":"20","author":"Hollis","year":"2021","journal-title":"Sports Biomech."},{"key":"pmeaad04b4bib33","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.gaitpost.2011.03.024","type":"journal-article","article-title":"Normative spatiotemporal gait parameters in older adults","volume":"34","author":"Hollman","year":"2011","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib34","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1016\/j.jsams.2012.01.004","type":"journal-article","article-title":"Comparison of plantar loads during treadmill and overground running","volume":"15","author":"Hong","year":"2012","journal-title":"J. Sci. Med. Sport"},{"key":"pmeaad04b4bib35","doi-asserted-by":"publisher","DOI":"10.3389\/fmedt.2022.901331","type":"journal-article","article-title":"Present and future of gait assessment in clinical practice: towards the application of novel trends and technologies","volume":"4","author":"Hulleck","year":"2022","journal-title":"Front. Med. Technol."},{"key":"pmeaad04b4bib36","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1080\/17434440.2016.1198694","type":"journal-article","article-title":"Wearable inertial sensors for human movement analysis","volume":"13","author":"Iosa","year":"2016","journal-title":"Expert Rev. Med. Devices"},{"key":"pmeaad04b4bib37","doi-asserted-by":"publisher","first-page":"\u2013","DOI":"10.1109\/TBME.2023.3301528","type":"journal-article","article-title":"Neural correlates of gait during overground and treadmill walking","volume":"PP","author":"Keller Xin Yu","year":"2021","journal-title":"An FNIRS Study"},{"key":"pmeaad04b4bib38","doi-asserted-by":"publisher","first-page":"4240","DOI":"10.3390\/s21124240","type":"journal-article","article-title":"Measurement of ankle joint movements using IMUs during running","volume":"21","author":"Kim","year":"2021","journal-title":"Sensors (Basel)"},{"key":"pmeaad04b4bib39","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","type":"journal-article","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"pmeaad04b4bib40","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.gaitpost.2019.04.015","type":"journal-article","article-title":"The conventional gait model, an open-source implementation that reproduces the past but prepares for the future","volume":"69","author":"Leboeuf","year":"2019","journal-title":"Gait & posture"},{"key":"pmeaad04b4bib41","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1152\/japplphysiol.01380.2006","type":"journal-article","article-title":"Biomechanics of overground vs. treadmill walking in healthy individuals","volume":"104","author":"Lee","year":"2008","journal-title":"J. Appl. Physiol."},{"key":"pmeaad04b4bib42","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.gaitpost.2010.06.009","type":"journal-article","article-title":"Identifying gait events without a force plate during running: a comparison of methods","volume":"33","author":"Leitch","year":"2011","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib43","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/S0022-3956(00)00017-0","type":"journal-article","article-title":"Spatiotemporal gait patterns during over ground locomotion in major depression compared with healthy controls","volume":"34","author":"Lemke","year":"2000","journal-title":"J. Psychiatric Res."},{"key":"pmeaad04b4bib44","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1038\/s41582-022-00730-w","type":"journal-article","article-title":"Daily step count linked to dementia risk","volume":"18","author":"Lempriere","year":"2022","journal-title":"Nat. Rev. Neurol."},{"key":"pmeaad04b4bib45","doi-asserted-by":"publisher","first-page":"459","DOI":"10.3390\/jcm8040459","type":"journal-article","article-title":"Effects of pulmonary rehabilitation on gait characteristics in patients with COPD","volume":"8","author":"Liu","year":"2019","journal-title":"J. Clin. Med.."},{"key":"pmeaad04b4bib46","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1586\/17434440.2016.1153421","type":"journal-article","article-title":"Potential of APDM mobility lab for the monitoring of the progression of Parkinson\u2019s disease.","volume":"13","author":"Mancini","year":"2016","journal-title":"Expert Rev. Med. Devices"},{"key":"pmeaad04b4bib47","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.gaitpost.2016.03.016","type":"journal-article","article-title":"Plantar pressure measurements and running-related injury: A systematic review of methods and possible associations","volume":"47","author":"Mann","year":"2016","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib48","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1007\/s40279-022-01760-6","type":"journal-article","article-title":"Wearables for running gait analysis: a systematic review","volume":"53","author":"Mason","year":"2022","journal-title":"Sports Med."},{"key":"pmeaad04b4bib49","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0291289","type":"journal-article","article-title":"Wearables for running gait analysis: a study protocol","volume":"18","author":"Mason","year":"2023","journal-title":"PLoS One"},{"key":"pmeaad04b4bib50","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1007\/s12283-012-0093-8","type":"journal-article","article-title":"Gyroscope-based assessment of temporal gait parameters during treadmill walking and running","volume":"15","author":"McGrath","year":"2012","journal-title":"Sports Eng."},{"key":"pmeaad04b4bib51","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.gaitpost.2010.09.020","type":"journal-article","article-title":"Running injury and stride time variability over a prolonged run","volume":"33","author":"Meardon","year":"2011","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib52","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1055\/a-1432-2336","type":"journal-article","article-title":"Continuous analysis of marathon running using inertial sensors: hitting two walls?","volume":"42","author":"Meyer","year":"2021","journal-title":"Int. J. Sports Med."},{"key":"pmeaad04b4bib53","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1007\/s40279-016-0474-4","type":"journal-article","article-title":"Is there an economical running technique? a review of modifiable biomechanical factors affecting running economy","volume":"46","author":"Moore","year":"2016","journal-title":"Sports Med. (Auckland, N.Z.)"},{"key":"pmeaad04b4bib54","doi-asserted-by":"publisher","first-page":"3341","DOI":"10.1016\/j.jbiomech.2007.05.001","type":"journal-article","article-title":"Effects of altered stride frequency and contact time on leg-spring behavior in human running","volume":"40","author":"Morin","year":"2007","journal-title":"J. Biomech."},{"key":"pmeaad04b4bib55","doi-asserted-by":"publisher","first-page":"095003","DOI":"10.1088\/1361-6579\/ab4023","type":"journal-article","article-title":"Validity of mobility lab (version 2) for gait assessment in young adults, older adults and Parkinson\u2019s disease.","volume":"40","author":"Morris","year":"2019","journal-title":"Physiol. Meas."},{"key":"pmeaad04b4bib56","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.clinbiomech.2011.10.005","type":"journal-article","article-title":"Proximal and distal kinematics in female runners with patellofemoral pain","volume":"27","author":"Noehren","year":"2012","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"pmeaad04b4bib57","doi-asserted-by":"publisher","first-page":"363","DOI":"10.23736\/S1973-9087.22.07037-X","type":"journal-article","article-title":"The reliability of gait parameters captured via instrumented walkways: a systematic review and meta-analysis","volume":"58","author":"Parati","year":"2022","journal-title":"Eur. J. Phys. Rehabil. Med."},{"key":"pmeaad04b4bib58","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1682\/JRRD.2007.02.0024","type":"journal-article","article-title":"Effect of treadmill exercise training on spatial and temporal gait parameters in subjects with chronic stroke: a preliminary report","volume":"45","author":"Patterson","year":"2008","journal-title":"J. Rehabil. Res. Dev."},{"key":"pmeaad04b4bib59","doi-asserted-by":"publisher","first-page":"274","DOI":"10.3109\/03091902.2014.909540","type":"journal-article","article-title":"Comparative abilities of microsoft kinect and vicon 3D motion capture for gait analysis","volume":"38","author":"Pfister","year":"2014","journal-title":"J. Med. Eng. Technol."},{"key":"pmeaad04b4bib60","doi-asserted-by":"publisher","first-page":"556","DOI":"10.2519\/jospt.2016.6280","type":"journal-article","article-title":"Reliability of a qualitative video analysis for running","volume":"46","author":"Pipkin","year":"2016","journal-title":"J. Orthop. Sports Phys. Ther."},{"key":"pmeaad04b4bib61","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-021-00538-w","type":"journal-article","article-title":"Sports related concussion: an emerging era in digital sports technology","volume":"4","author":"Powell","year":"2021","journal-title":"npj Digital Medicine."},{"key":"pmeaad04b4bib62","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.jmbbm.2018.08.032","type":"journal-article","article-title":"Effect of the cushioning running shoes in ground contact time of phases of gait","volume":"88","author":"Roca-Dols","year":"2018","journal-title":"Journal of the mechanical behavior of biomedical materials"},{"key":"pmeaad04b4bib63","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1159\/000512513","type":"journal-article","article-title":"A roadmap to inform development, validation and approval of digital mobility outcomes: the mobilise-D approach (2504-110X (Electronic))","volume":"4","author":"Rochester","year":"2020","journal-title":"Digital biomarkers"},{"key":"pmeaad04b4bib64","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1109\/TBME.2004.840727","type":"journal-article","article-title":"Assessment of walking features from foot inertial sensing","volume":"52","author":"Sabatini","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaad04b4bib65","doi-asserted-by":"publisher","first-page":"2910","DOI":"10.1007\/s11999-008-0524-9","type":"journal-article","article-title":"Methods for assessing leg length discrepancy","volume":"466","author":"Sabharwal","year":"2008","journal-title":"Clin. Orthop. Relat. Res."},{"key":"pmeaad04b4bib66","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1123\/ijspp.2014-0179","type":"journal-article","article-title":"Gait-cycle characteristics and running economy in elite Eritrean and European runners","volume":"10","author":"Santos-Concejero","year":"2015","journal-title":"Int. J. Sports Physiol. Perform"},{"key":"pmeaad04b4bib67","doi-asserted-by":"publisher","DOI":"10.1186\/1479-5868-10-126","type":"journal-article","article-title":"Adult self-reported and objectively monitored physical activity and sedentary behavior: NHANES 2005\u20132006","volume":"10","author":"Schuna","year":"2013","journal-title":"Int. J. Behav. Nutrition Phys. Activity"},{"key":"pmeaad04b4bib68","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1080\/17461391.2018.1477993","type":"journal-article","article-title":"Accuracy and precision of loadsol((R)) insole force-sensors for the quantification of ground reaction force-based biomechanical running parameters","volume":"18","author":"Seiberl","year":"2018","journal-title":"Eur. J. Sport Sci."},{"key":"pmeaad04b4bib69","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1016\/j.gaitpost.2022.01.024","type":"journal-article","article-title":"Smartphone-based inertial sensors technology\u2014validation of a new application to measure spatiotemporal gait metrics","volume":"93","author":"Shema-Shiratzky","year":"2022","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib70","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","type":"journal-article","article-title":"Intraclass correlations: uses in assessing rater reliability","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol. Bull."},{"key":"pmeaad04b4bib71","doi-asserted-by":"publisher","first-page":"41","DOI":"10.2478\/hukin-2014-0109","type":"journal-article","article-title":"Impact of center-of-mass acceleration on the performance of ultramarathon runners","volume":"44","author":"Shun-Ping","year":"2014","journal-title":"J. Human Kinetics"},{"key":"pmeaad04b4bib72","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1097\/PHM.0b013e318201741e","type":"journal-article","article-title":"Improved gait after repetitive locomotor training in children with cerebral palsy","volume":"90","author":"Smania","year":"2011","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"pmeaad04b4bib73","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.gaitpost.2014.08.009","type":"journal-article","article-title":"A comparison of kinematic algorithms to estimate gait events during overground running","volume":"41","author":"Smith","year":"2015","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib74","doi-asserted-by":"publisher","first-page":"22089","DOI":"10.3390\/s150922089","type":"journal-article","article-title":"Inertial sensor-based gait recognition: a review","volume":"15","author":"Sprager","year":"2015","journal-title":"Sensors (Basel)"},{"key":"pmeaad04b4bib75","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1080\/02640414.2016.1161205","type":"journal-article","article-title":"Validation of Moticon\u2019s OpenGo sensor insoles during gait, jumps, balance and cross-country skiing specific imitation movements.","volume":"35","author":"St\u00f6ggl","year":"2017","journal-title":"J. Sports Sci."},{"key":"pmeaad04b4bib76","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0196463","type":"journal-article","article-title":"Free-living and laboratory gait characteristics in patients with multiple sclerosis","volume":"13","author":"Storm","year":"2018","journal-title":"PLoS One"},{"key":"pmeaad04b4bib77","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.gaitpost.2016.08.012","type":"journal-article","article-title":"Gait event detection in laboratory and real life settings: Accuracy of ankle and waist sensor based methods","volume":"50","author":"Storm","year":"2016","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib78","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1038\/s41746-022-00745-z","type":"journal-article","article-title":"A \u2018one-size-fits-most\u2019 walking recognition method for smartphones, smartwatches, and wearable accelerometers","volume":"6","author":"Straczkiewicz","year":"2023","journal-title":"npj Digital Med."},{"key":"pmeaad04b4bib79","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/B978-0-12-818914-6.00021-1","type":"book","article-title":"chapter 15 - Sports medicine: bespoke player management","author":"Stuart","year":"2021"},{"key":"pmeaad04b4bib80","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1109\/JBHI.2020.3014963","type":"journal-article","article-title":"Accurate impact loading rate estimation during running via a subject-independent convolutional neural network model and optimal IMU placement","volume":"25","author":"Tan","year":"2020","journal-title":"IEEE Journal of Biomedical and Health Informatics"},{"key":"pmeaad04b4bib81","doi-asserted-by":"publisher","first-page":"731","DOI":"10.26603\/ijspt20190731","type":"journal-article","article-title":"Spatiotemporal comparison of overground and treadmill running with pressure sensor insoles in division i collegiate runners","volume":"14","author":"Tao","year":"2019","journal-title":"Int. J. Sports Phys. Ther."},{"key":"pmeaad04b4bib82","doi-asserted-by":"publisher","first-page":"2255","DOI":"10.3390\/s120202255","type":"journal-article","article-title":"Gait analysis using wearable sensors","volume":"12","author":"Tao","year":"2012","journal-title":"Sensors (Basel)"},{"key":"pmeaad04b4bib83","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.gaitpost.2018.03.041","type":"journal-article","article-title":"Treadmill walking reduces pre-frontal activation in patients with Parkinson\u2019s disease","volume":"62","author":"Thumm","year":"2018","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib84","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1123\/jmpb.2018-0050","type":"journal-article","article-title":"Effects of brief intermittent walking bouts on step count accuracy of wearable devices","volume":"2","author":"Toth","year":"2023","journal-title":"J. Meas. Phys. Behav."},{"key":"pmeaad04b4bib85","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1007\/s40279-019-01237-z","type":"journal-article","article-title":"Is motorized treadmill running biomechanically comparable to overground running? a systematic review and meta-analysis of cross-over studies","volume":"50","author":"Van Hooren","year":"2020","journal-title":"Sports Med."},{"key":"pmeaad04b4bib86","doi-asserted-by":"publisher","first-page":"e79","DOI":"10.1016\/j.apmr.2021.07.708","type":"journal-article","article-title":"Comparing accuracy of step count detection algorithm at different activity monitor wear locations","volume":"102","author":"Veerubhotla","year":"2021","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"pmeaad04b4bib87","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1007\/s10072-012-1202-y","type":"journal-article","article-title":"Effect of global postural rehabilitation program on spatiotemporal gait parameters of parkinsonian patients: a three-dimensional motion analysis study","volume":"33","author":"Vitale","year":"2012","journal-title":"Neurological Sci."},{"key":"pmeaad04b4bib88","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.gaitpost.2017.04.013","type":"journal-article","article-title":"Validity and repeatability of inertial measurement units for measuring gait parameters","volume":"55","author":"Washabaugh","year":"2017","journal-title":"Gait. Posture"},{"key":"pmeaad04b4bib89","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1136\/bjsports-2020-103147","type":"journal-article","article-title":"Recommendations for determining the validity of consumer wearable and smartphone step count: expert statement and checklist of the INTERLIVE network","volume":"55","author":"Johnston","year":"2021","journal-title":"Br. J. Sports Med."},{"key":"pmeaad04b4bib90","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.ptsp.2017.10.003","type":"journal-article","article-title":"Innovations and pitfalls in the use of wearable devices in the prevention and rehabilitation of running related injuries","volume":"29","author":"Willy","year":"2018","journal-title":"Phys. Therapy Sport"},{"key":"pmeaad04b4bib91","doi-asserted-by":"publisher","first-page":"375","DOI":"10.2519\/jospt.2015.5741","type":"journal-article","article-title":"A consensus definition of running-related injury in recreational runners: a modified Delphi approach","volume":"45","author":"Yamato","year":"2015","journal-title":"American journal of physical medicine & rehabilitation"},{"key":"pmeaad04b4bib92","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2022.956889","type":"journal-article","article-title":"Examination of a foot mounted IMU-based methodology for a running gait assessment","volume":"4","author":"Young","year":"2022","journal-title":"Front. Sports Active Living"},{"key":"pmeaad04b4bib93","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.gaitpost.2018.02.007","type":"journal-article","article-title":"Gait analysis in patients with chronic obstructive pulmonary disease: a systematic review","volume":"61","author":"Zago","year":"2018","journal-title":"Gait Posture"},{"key":"pmeaad04b4bib94","doi-asserted-by":"publisher","first-page":"15","DOI":"10.3390\/s20154098","type":"journal-article","article-title":"Classification of neurological patients to identify fallers based on spatial-temporal gait characteristics measured by a wearable device","volume":"20","author":"Zhou","year":"2020","journal-title":"Sensors"}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T16:58:59Z","timestamp":1778777939000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad04b4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,1]]},"references-count":94,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2023,11,6]]},"published-print":{"date-parts":[[2023,11,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/ad04b4","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,1]]},"assertion":[{"value":"Validity and reliability of the DANU sports system for walking and running gait assessment","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2023-07-04","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-10-18","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-11-06","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}