{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T15:33:17Z","timestamp":1784043197708,"version":"3.55.0"},"reference-count":41,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T00:00:00Z","timestamp":1707091200000},"content-version":"vor","delay-in-days":4,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T00:00:00Z","timestamp":1707091200000},"content-version":"tdm","delay-in-days":4,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001821","name":"Vienna Science and Technology Fund","doi-asserted-by":"crossref","award":["LS20-079"],"award-info":[{"award-number":["LS20-079"]}],"id":[{"id":"10.13039\/501100001821","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2024,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . Bioimpedance spectroscopy (BIS) is a non-invasive diagnostic tool to derive fluid volume compartments from frequency dependent voltage drops in alternating currents by extrapolating to the extracellular resistance (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sub>0<\/jats:sub>\n                    ) and intracellular resistance (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sub>i<\/jats:sub>\n                    ). Here we tested whether a novel BIS device with reusable and adhesive single-use electrodes produces results which are (in various body positions) equivalent to an established system employing only single-use adhesive electrodes.\n                    <jats:italic>Approach<\/jats:italic>\n                    . Two BIS devices (\u2018Cella\u2019 and the \u2018Body Composition Monitor\u2019 [BCM]) were compared using four dedicated resistance testboxes and by measuring 40 healthy volunteers.\n                    <jats:italic>In<\/jats:italic>\n                    <jats:italic>vivo<\/jats:italic>\n                    comparisons included supine wrist-to-ankle (WA) reference measurements and wrist-to-wrist (WW) measurements with pre-gelled silver\/silver-chloride (Ag\/AgCl) electrodes and WW measurements with reusable gold-plated copper electrodes.\n                    <jats:italic>Main results<\/jats:italic>\n                    . Coefficient of variation were &lt;1% for all testbox measurements with both BIS devices. Accuracy was within \u00b11% of true resistance variability, a threshold which was only exceeded by the Cella device for all resistances in a testbox designed with a low\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sub>0<\/jats:sub>\n                    \/\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sub>i<\/jats:sub>\n                    ratio.\n                    <jats:italic>In<\/jats:italic>\n                    <jats:italic>vivo<\/jats:italic>\n                    , WA-BIS differed significantly between BIS devices (\n                    <jats:italic>p<\/jats:italic>\n                    &lt; 0.001). Reusable WW electrodes exhibited larger resistances than WW-BIS with Ag\/AgCl electrodes (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sub>0<\/jats:sub>\n                    : 738.36 and 628.69 \u03a9;\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sub>i<\/jats:sub>\n                    : 1508.18 and 1390 \u03a9) and the relative error varied from 7.6% to 31.1% (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sub>0<\/jats:sub>\n                    ) and \u221215.6% to 37.3% (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sub>i<\/jats:sub>\n                    ).\n                    <jats:italic>Significance<\/jats:italic>\n                    . Both BIS devices produced equivalent resistances measurements but different estimates of body composition both\n                    <jats:italic>in<\/jats:italic>\n                    <jats:italic>silico<\/jats:italic>\n                    and in WA setups\n                    <jats:italic>in<\/jats:italic>\n                    <jats:italic>vivo<\/jats:italic>\n                    , suggesting that the devices should not be used interchangeably. Employing WW reusable electrodes as opposed to WA and WW measurement setups with pre-gelled Ag\/AgCl electrodes seems to be associated with measurement variations that are too large for safe clinical use. We recommend further investigations of measurement errors originating from electrode material and current path.\n                  <\/jats:p>","DOI":"10.1088\/1361-6579\/ad205b","type":"journal-article","created":{"date-parts":[[2024,1,18]],"date-time":"2024-01-18T17:49:21Z","timestamp":1705600161000},"page":"025001","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Assessment of bioimpedance spectroscopy devices: a comparative study and error analysis of gold-plated copper electrodes"],"prefix":"10.1088","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2223-2067","authenticated-orcid":false,"given":"Sebastian","family":"Mussnig","sequence":"first","affiliation":[{"name":"Medical University of Vienna"},{"name":"Medical University of Vienna"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0899-9085","authenticated-orcid":false,"given":"Simon","family":"Krenn","sequence":"additional","affiliation":[{"name":"AIT Austrian Institute of Technology GmbH, Center for Health & Bioresources, Medical Signal Analysis, Vienna,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8047-2395","authenticated-orcid":false,"given":"Manfred","family":"Hecking","sequence":"additional","affiliation":[{"name":"Medical University of Vienna"},{"name":"Medical University of Vienna"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Wabel","sequence":"additional","affiliation":[{"name":"Independent Researcher, Rosbach,"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,2,5]]},"reference":[{"key":"pmeaad205bbib1","article-title":"Method and device for determining the hydration, fitness and nutrition status of a human body","author":"Baricevic","year":"2022","type":"patent"},{"key":"pmeaad205bbib2","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1053\/j.ajkd.2011.02.395","type":"journal-article","article-title":"Volume depletion versus dehydration: how understanding the difference can guide therapy","volume":"58","author":"Bhave","year":"2011","journal-title":"Am. J. Kidney Dis. Off J. Natl. Kidney Found"},{"key":"pmeaad205bbib3","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.1016\/j.medengphy.2012.05.011","type":"journal-article","article-title":"Influence of electrode mismatch on cole parameter estimation from total right side electrical bioimpedance spectroscopy measurements","volume":"34","author":"Buend\u00eda","year":"2012","journal-title":"Med. Eng. Phys."},{"key":"pmeaad205bbib4","article-title":"A method and a device for determining the dry weight of a patient with kidney failure.","author":"Chamney","year":"2002","type":"patent"},{"key":"pmeaad205bbib5","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1093\/ajcn\/85.1.80","type":"journal-article","article-title":"A whole-body model to distinguish excess fluid from the hydration of major body tissues","volume":"85","author":"Chamney","year":"2007","journal-title":"Am. J. Clin. Nutr."},{"key":"pmeaad205bbib6","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1085\/jgp.12.1.29","type":"journal-article","article-title":"Electrical impedance of suspensions of spheres","volume":"12","author":"Cole","year":"1928","journal-title":"J. Gen. Physiol."},{"key":"pmeaad205bbib7","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1063\/1.1750906","type":"journal-article","article-title":"Dispersion and absorption in dielectrics: I. Alternating current characteristics","volume":"9","author":"Cole","year":"1941","journal-title":"J. Chem. Phys."},{"key":"pmeaad205bbib8","first-page":"159","type":"journal-article","article-title":"Evaluation of multiple frequency bioelectrical impedance and Cole\u2013Cole analysis for the assessment of body water volumes in healthy humans","volume":"50","author":"Cornish","year":"1996","journal-title":"Eur. J. Clin. Nutr."},{"key":"pmeaad205bbib9","first-page":"127","type":"journal-article","article-title":"Bio-electrical impedance spectroscopy: alternatives for the conventional hand-to-foot measurements","volume":"21","author":"Cox-Reijven","year":"2002","journal-title":"Clin. Nutr. Edinb. Scotl."},{"key":"pmeaad205bbib10","doi-asserted-by":"publisher","first-page":"1542","DOI":"10.1152\/jappl.1997.82.5.1542","type":"journal-article","article-title":"Predicting body cell mass with bioimpedance by using theoretical methods: a technological review","volume":"82","author":"De Lorenzo","year":"1997","journal-title":"J. Appl. Physiol."},{"key":"pmeaad205bbib11","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1016\/j.kint.2016.12.008","type":"journal-article","article-title":"Impact of fluid status and inflammation and their interaction on survival: a study in an international hemodialysis patient cohort","volume":"91","author":"Dekker","year":"2017","journal-title":"Kidney Int."},{"key":"pmeaad205bbib12","doi-asserted-by":"crossref","DOI":"10.1515\/ijb-2019-0157","type":"journal-article","article-title":"Derivation of passing-bablok regression from Kendall\u2019s tau","volume":"16","author":"Dufey","year":"2020","journal-title":"Int. J. Biostat."},{"key":"pmeaad205bbib13","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1088\/0022-3727\/40\/1\/S02","type":"journal-article","article-title":"Sources of error in tetrapolar impedance measurements on biomaterials and other ionic conductors","volume":"40","author":"Grimnes","year":"2007","journal-title":"J. Phys. Appl. Phys."},{"key":"pmeaad205bbib14","doi-asserted-by":"publisher","first-page":"1832","DOI":"10.1093\/ndt\/gfy083","type":"journal-article","article-title":"Greater fluid overload and lower interdialytic weight gain are independently associated with mortality in a large international hemodialysis population","volume":"33","author":"Hecking","year":"2018","journal-title":"Nephrol. Dial Transplant Off. Publ. Eur. Dial. Transpl. Assoc.\u2014Eur. Ren. Assoc."},{"key":"pmeaad205bbib15","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1111\/jorc.12091","type":"journal-article","article-title":"Use of hand-to-hand measurements for body composition monitoring in patients with inaccessible or amputated feet","volume":"41","author":"Keane","year":"2015","journal-title":"J. Ren. Care"},{"key":"pmeaad205bbib16","article-title":"Multifrequency bioimpedance determination","author":"Kennedy","year":"2005","type":"patent"},{"key":"pmeaad205bbib17","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1089\/lrb.2019.0067","type":"journal-article","article-title":"Body positional effects on bioimpedance spectroscopy measurements for lymphedema assessment of the arm","volume":"18","author":"Koelmeyer","year":"2020","journal-title":"Lymphat Res. Biol."},{"key":"pmeaad205bbib18","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/aaea59","type":"journal-article","article-title":"Dry electrodes for bioimpedance measurements\u2014design, characterization and comparison","volume":"5","author":"Kusche","year":"2018","journal-title":"Biomed. Phys. Eng. Express"},{"key":"pmeaad205bbib19","first-page":"1226","type":"journal-article","article-title":"Bioelectrical impedance analysis: I. Review of principles and methods","volume":"23","author":"Kyle","year":"2004","journal-title":"Clin. Nutr. Edinb. Scotl."},{"key":"pmeaad205bbib20","doi-asserted-by":"publisher","first-page":"8705","DOI":"10.3390\/s22228705","type":"journal-article","article-title":"Parasitic effects on electrical bioimpedance systems: critical review","volume":"22(22)","author":"Marc\u00f4ndes","year":"2022","journal-title":"Sensors"},{"key":"pmeaad205bbib21","doi-asserted-by":"publisher","author":"Matthie","year":"2021","DOI":"10.1101\/2021.09.13.21263290","type":"preprint"},{"key":"pmeaad205bbib22","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1152\/japplphysiol.00145.2005","type":"journal-article","article-title":"Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy","volume":"99","author":"Matthie","year":"2005","journal-title":"J. Appl. Physiol. Bethesda Md. 1985"},{"key":"pmeaad205bbib23","doi-asserted-by":"crossref","DOI":"10.1063\/1.2815666","type":"journal-article","article-title":"Two- and four-electrode, wide-bandwidth, dielectric spectrometer for conductive liquids: theory, limitations, and experiment","volume":"102","author":"Mazzeo","year":"2007","journal-title":"J. Appl. Phys."},{"key":"pmeaad205bbib24","first-page":"257A","type":"journal-article","article-title":"Validation of a 3C model for determination of body fat mass","volume":"18","author":"Moissl","year":"2007","journal-title":"J. Am. Soc. Nephrol."},{"key":"pmeaad205bbib25","first-page":"215","type":"journal-article","article-title":"Validation of a bioimpedance spectroscopy method for the assessment of fat free mass","volume":"1","author":"Moissl","year":"2008","journal-title":"NDT Plus"},{"key":"pmeaad205bbib26","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1088\/0967-3334\/27\/9\/012","type":"journal-article","article-title":"Body fluid volume determination via body composition spectroscopy in health and disease","volume":"27","author":"Moissl","year":"2006","journal-title":"Physiol. Meas."},{"key":"pmeaad205bbib27","doi-asserted-by":"crossref","DOI":"10.1016\/j.nut.2023.112131","type":"journal-article","article-title":"Differences in bioimpedance-derived fluid status between two versions of the body composition monitor","author":"Mussnig","year":"2023","journal-title":"Nutrition"},{"key":"pmeaad205bbib28","doi-asserted-by":"publisher","first-page":"1\u20132","DOI":"10.1093\/ndt\/gfad063c_4657","type":"journal-article","article-title":"#4657 COMPARISON OF TWO BIOIMPEDANCE SPECTROSCOPY DEVICES: A PRACTICAL STEP FORWARD ON THE WAY TO DAILY BIOIMPEDANCE MEASUREMENTS FOR DIALYSIS PATIENTS","volume":"38","author":"Mussnig","year":"2023","journal-title":"Nephrology Dialysis Transplantation"},{"key":"pmeaad205bbib29","doi-asserted-by":"crossref","first-page":"70","DOI":"10.3390\/s20010070","type":"journal-article","article-title":"Smart bioimpedance spectroscopy device for body composition estimation","volume":"20","author":"Naranjo-Hern\u00e1ndez","year":"2020","journal-title":"Sensors"},{"key":"pmeaad205bbib30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/9210258","type":"journal-article","article-title":"Fundamentals, recent advances, and future challenges in bioimpedance devices for healthcare applications","volume":"2019","author":"Naranjo-Hern\u00e1ndez","year":"2019","journal-title":"J. Sens."},{"key":"pmeaad205bbib31","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1038\/ejcn.2016.121","type":"journal-article","article-title":"Different displacement of bioimpedance vector due to Ag\/AgCl electrode effect","volume":"70","author":"Nescolarde","year":"2016","journal-title":"Eur. J. Clin. Nutr."},{"key":"pmeaad205bbib32","author":"Potapov","year":"2023","unstructured":"Potapov S 2023 mcr: Method Comparison Regression Available from: https:\/\/cran.r-project.org\/web\/packages\/mcr\/index.html","type":"software"},{"key":"pmeaad205bbib33","first-page":"1","type":"journal-article","article-title":"Bioimpedance sensing in wearable systems: From hardware integration to model development","volume":"2017","author":"Rossi","year":"2017","journal-title":"IEEE 3rd Int. Forum Res. Technol. Soc. Ind. RTSI."},{"key":"pmeaad205bbib34","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1053\/j.ajkd.2007.03.012","type":"journal-article","article-title":"Dehydration versus volume depletion\u2014and the importance of getting it right","volume":"49","author":"Spital","year":"2007","journal-title":"Am. J. Kidney Dis. Off J. Natl. Kidney Found"},{"key":"pmeaad205bbib35","author":"Stevenson","year":"2024","unstructured":"Stevenson M 2024 R: Concordance Correlation Coefficient Available from: https:\/\/search.r-project.org\/CRAN\/refmans\/DescTools\/html\/CCC.html","type":"software"},{"key":"pmeaad205bbib36","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1159\/000167013","type":"journal-article","article-title":"Importance of whole-body bioimpedance spectroscopy for the management of fluid balance","volume":"27","author":"Wabel","year":"2009","journal-title":"Blood Purif."},{"key":"pmeaad205bbib37","first-page":"22","type":"journal-article","article-title":"Accuracy of bioimpedance spectroscopy (BIS) to detect fluid status changes in hemodialysis patients (abstract)","volume":"Suppl 6","author":"Wabel","year":"2006","journal-title":"Nephrol. Dial. Transpl."},{"key":"pmeaad205bbib38","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/ac5e83","type":"journal-article","article-title":"Individualized body geometry correction factor (K B ) for use when predicting body composition from bioimpedance spectroscopy","volume":"43","author":"Ward","year":"2022","journal-title":"Physiol. Meas."},{"key":"pmeaad205bbib39","author":"Webster","year":"2020","edition":"5th edn","type":"book"},{"key":"pmeaad205bbib40","article-title":"Method and apparatus for displaying multi-frequency bio-impedance","author":"Withers","year":"1994","type":"patent"},{"key":"pmeaad205bbib41","doi-asserted-by":"publisher","first-page":"2491","DOI":"10.1681\/ASN.2016121341","type":"journal-article","article-title":"Chronic fluid overload and mortality in ESRD","volume":"28","author":"Zoccali","year":"2017","journal-title":"J. Am. Soc. Nephrol. JASN"}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T17:05:26Z","timestamp":1778778326000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad205b"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,1]]},"references-count":41,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,2,5]]},"published-print":{"date-parts":[[2024,2,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/ad205b","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,1]]},"assertion":[{"value":"Assessment of bioimpedance spectroscopy devices: a comparative study and error analysis of gold-plated copper electrodes","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2023-10-11","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-01-18","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-05","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}