{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T18:46:55Z","timestamp":1754160415549,"version":"3.41.2"},"reference-count":41,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2024,5,28]],"date-time":"2024-05-28T00:00:00Z","timestamp":1716854400000},"content-version":"vor","delay-in-days":27,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,5,28]],"date-time":"2024-05-28T00:00:00Z","timestamp":1716854400000},"content-version":"tdm","delay-in-days":27,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2024,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> Diagnosis of incipient acute hypovolemia is challenging as vital signs are typically normal and patients remain asymptomatic at early stages. The early identification of this entity would affect patients\u2019 outcome if physicians were able to treat it precociously. Thus, the development of a noninvasive, continuous bedside monitoring tool to detect occult hypovolemia before patients become hemodynamically unstable is clinically relevant. We hypothesize that pulse oximeter\u2019s alternant (AC) and continuous (DC) components of the infrared light are sensitive to acute and small changes in patient\u2019s volemia. We aimed to test this hypothesis in a cohort of healthy blood donors as a model of slight hypovolemia. <jats:italic>Approach.<\/jats:italic> We planned to prospectively study blood donor volunteers removing 450 ml of blood in supine position. Noninvasive arterial blood pressure, heart rate, and finger pulse oximetry were recorded. Data was analyzed before donation, after donation and during blood auto-transfusion generated by the passive leg-rising (PLR) maneuver. <jats:italic>Main results.<\/jats:italic> Sixty-six volunteers (44% women) accomplished the protocol successfully. No clinical symptoms of hypovolemia, arterial hypotension (systolic pressure &lt; 90 mmHg), brady-tachycardia (heart rate &lt;60 and &gt;100 beats-per-minute) or hypoxemia (SpO<jats:sub>2<\/jats:sub> &lt; 90%) were observed during donation. The AC signal before donation (median 0.21 and interquartile range 0.17 a.u.) increased after donation [0.26(0.19) a.u; <jats:italic>p<\/jats:italic> &lt; 0.001]. The DC signal before donation [94.05(3.63) a.u] increased after blood extraction [94.65(3.49) a.u; <jats:italic>p<\/jats:italic> &lt; 0.001]. When the legs\u2019 blood was auto-transfused during the PLR, the AC [0.21(0.13) a.u.; <jats:italic>p<\/jats:italic> = 0.54] and the DC [94.25(3.94) a.u.; <jats:italic>p<\/jats:italic> = 0.19] returned to pre-donation levels. <jats:italic>Significance.<\/jats:italic> The AC and DC components of finger pulse oximetry changed during blood donation in asymptomatic volunteers. The continuous monitoring of these signals could be helpful in detecting occult acute hypovolemia. New pulse oximeters should be developed combining the AC\/DC signals with a functional hemodynamic monitoring of fluid responsiveness to define which patient needs fluid administration.<\/jats:p>","DOI":"10.1088\/1361-6579\/ad4c54","type":"journal-article","created":{"date-parts":[[2024,5,15]],"date-time":"2024-05-15T18:44:23Z","timestamp":1715798663000},"page":"055018","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Finger photopletysmography detects early acute blood loss in compensated blood donors: a pilot study"],"prefix":"10.1088","volume":"45","author":[{"given":"Gerardo","family":"Speroni","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patricia","family":"Antedoro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Silvia","family":"Marturet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabriela","family":"Martino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Celia","family":"Chavez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristian","family":"Hidalgo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mar\u00eda V","family":"Villacorta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ivo","family":"Ahrtz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manuel","family":"Casadei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nora","family":"Fuentes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Kremeier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephan H","family":"B\u00f6hm","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerardo","family":"Tusman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,5,28]]},"reference":[{"key":"pmeaad4c54bib1","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1007\/s10877-011-9316-y","article-title":"Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers. Part 1: time domain analysis","volume":"25","author":"Alian","year":"2011","journal-title":"J. Clin. Monit. Comput."},{"key":"pmeaad4c54bib2","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","article-title":"Photoplethysmography and its application in clinical physiological measurement","volume":"28","author":"Allen","year":"2007","journal-title":"Physiol. Meas."},{"key":"pmeaad4c54bib3","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1111\/j.1475-097X.1993.tb00472.x","article-title":"DC photoplethysmography in the evaluation of sympathetic vasomotor responses","volume":"13","author":"Barron","year":"1993","journal-title":"Clin. Physiol."},{"key":"pmeaad4c54bib4","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1007\/BF02345963","article-title":"Right-left correlation of the sympathetically induced fluctuations of photoplethysmographic signal in diabetic and non-diabetic subjects","volume":"43","author":"Buchs","year":"2005","journal-title":"Med. Biol. Eng. Comput."},{"key":"pmeaad4c54bib5","doi-asserted-by":"publisher","DOI":"10.14814\/phy2.12705","article-title":"Variability in integration of mechanisms associated with high tolerance to progressive reductions in central blood volume: the compensatory reserve","volume":"4","author":"Carter","year":"2016","journal-title":"Physiol. Rep."},{"key":"pmeaad4c54bib6","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1007\/s00134-008-1292-4","article-title":"Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique","volume":"35","author":"Cecconi","year":"2009","journal-title":"Intensive Care Med."},{"key":"pmeaad4c54bib7","doi-asserted-by":"publisher","first-page":"1827","DOI":"10.3390\/jcm8111827","article-title":"Multi-site photoplethysmography technology for blood pressure assessment: challenges and recommendations","volume":"8","author":"Chan","year":"2019","journal-title":"J. Clin. Med."},{"key":"pmeaad4c54bib8","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1097\/SHK.0000000000000323","article-title":"Individual-specific, beat-to-beat trending of significant human blood loss: the compensatory reserve","volume":"44","author":"Convertino","year":"2015","journal-title":"Shock"},{"key":"pmeaad4c54bib9","doi-asserted-by":"publisher","first-page":"S150","DOI":"10.1111\/trf.15632","article-title":"The compensatory reserve: potential for accurate individualized goal\u2010directed whole blood resuscitation","volume":"60","author":"Convertino","year":"2020","journal-title":"Transfusion"},{"key":"pmeaad4c54bib10","doi-asserted-by":"publisher","first-page":"S57","DOI":"10.1097\/TA.0000000000001430","article-title":"Measuring the compensatory reserve to identify shock","volume":"82","author":"Convertino","year":"2017","journal-title":"J. Trauma Acute Care Surg."},{"key":"pmeaad4c54bib11","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1097\/SHK.0000000000000559","article-title":"The compensatory reserve for early and accurate prediction of hemodynamic compromise: a review of the underlying physiology","volume":"45","author":"Convertino","year":"2016","journal-title":"Shock"},{"key":"pmeaad4c54bib12","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1152\/japplphysiol.01155.2003","article-title":"Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans","volume":"96","author":"Cooke","year":"2004","journal-title":"J. Appl. Physiol."},{"key":"pmeaad4c54bib13","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1111\/j.1549-8719.2011.00131.x","article-title":"Perspective: physiological role(s) of the vascular myogenic response","volume":"19","author":"Davis","year":"2012","journal-title":"Microcirculation"},{"key":"pmeaad4c54bib14","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/S0002-8703(41)90966-3","article-title":"The form of the volume pulse in the finger pad in health, arteriosclerosis, and hypertension","volume":"21","author":"Dillon","year":"1941","journal-title":"Am. Heart J."},{"key":"pmeaad4c54bib15","doi-asserted-by":"publisher","first-page":"H59","DOI":"10.1152\/ajpheart.00609.2014","article-title":"Myogenic responses occur on a beat-to-beat basis in the resting human limb","volume":"308","author":"Fairfax","year":"2015","journal-title":"Am. J. Physiol. Heart. Circ. Physiol."},{"key":"pmeaad4c54bib16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/cc2404","article-title":"Clinical review: hemorrhagic shock","volume":"8","author":"Gutierrez","year":"2004","journal-title":"Crit. Care"},{"key":"pmeaad4c54bib17","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1097\/00005373-199801000-00016","article-title":"Use of stroke distance in the early detection of simulated blood loss","volume":"44","author":"Hanson","year":"1998","journal-title":"J. Trauma Acute Care Surg."},{"key":"pmeaad4c54bib18","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1097\/ALN.0000000000002413","article-title":"Morbidity and mortality of crystalloids compared to colloids in critically ill surgical patients: a subgroup analysis of a randomized trial","volume":"129","author":"Heming","year":"2018","journal-title":"Anesthesiology"},{"key":"pmeaad4c54bib19","first-page":"555","article-title":"Early identification of occult bleeding through hypovolemia detection","author":"Holder","year":"2014"},{"key":"pmeaad4c54bib20","doi-asserted-by":"publisher","first-page":"S8","DOI":"10.1186\/cc14726","article-title":"Hemodynamic coherence and the rationale for monitoring the microcirculation","volume":"19","author":"Ince","year":"2015","journal-title":"Crit. Care"},{"key":"pmeaad4c54bib21","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/0169-2607(89)90159-4","article-title":"Skin photoplethysmography\u2014a review","volume":"28","author":"Kamal","year":"1989","journal-title":"Comput. Methods Programs Biomed."},{"key":"pmeaad4c54bib22","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1097\/01.ta.0000199961.02677.19","article-title":"Impact of hemorrhage on trauma outcome: an overview of epidemiology, clinical presentations, and therapeutic considerations","volume":"60","author":"Kauvar","year":"2006","journal-title":"J. Trauma"},{"key":"pmeaad4c54bib23","doi-asserted-by":"publisher","first-page":"e7045","DOI":"10.1097\/MD.0000000000007045","article-title":"The photoplethysmographic amplitude to pulse pressure ratio can track sudden changes in vascular compliance and resistance during liver graft reperfusion: a beat-to-beat analysis","volume":"96","author":"Kim","year":"2017","journal-title":"Medicine"},{"key":"pmeaad4c54bib24","doi-asserted-by":"publisher","first-page":"449","DOI":"10.7863\/jum.1990.9.8.449","article-title":"Doppler blood velocity waveforms and the relation to peripheral resistance in the brachial artery","volume":"9","author":"Legarth","year":"1990","journal-title":"J. Ultrasound Med."},{"key":"pmeaad4c54bib25","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2022.106677","article-title":"Application of photoplethysmography signals for healthcare systems: an in-depth review","volume":"216","author":"Loh","year":"2022","journal-title":"Comput. Methods Programs Biomed."},{"key":"pmeaad4c54bib26","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1038\/213841a0","article-title":"Characteristic pulse wave caused by organic nitrates","volume":"213","author":"Morikawa","year":"1967","journal-title":"Nature"},{"key":"pmeaad4c54bib27","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1097\/TA.0b013e31820e77ea","article-title":"Hypotensive resuscitation strategy reduces transfusion requirements and severe postoperative coagulopathy in trauma patients with hemorrhagic shock: preliminary results of a randomized controlled trial","volume":"70","author":"Morrison","year":"2011","journal-title":"J. Trauma Acute Care Surg."},{"key":"pmeaad4c54bib28","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.clinbiomech.2018.06.005","article-title":"The response of peripheral microcirculation to gravity-induced changes","volume":"57","author":"Ovadia-Blechman","year":"2018","journal-title":"Clin. Biomech."},{"key":"pmeaad4c54bib29","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1038\/s41746-019-0207-9","article-title":"Photoplethysmography based atrial fibrillation detection: a review","volume":"3","author":"Pereira","year":"2020","journal-title":"npj Digit. Med."},{"key":"pmeaad4c54bib30","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1097\/ALN.0b013e31816c89e1","article-title":"Utility of the photoplethysmogram in circulatory monitoring","volume":"108","author":"Reisner","year":"2008","journal-title":"J. Am. Soc. Anesth."},{"key":"pmeaad4c54bib31","doi-asserted-by":"publisher","first-page":"1429","DOI":"10.1007\/s00134-012-2621-1","article-title":"Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis","volume":"38","author":"Sandroni","year":"2012","journal-title":"Intensive Care Med."},{"key":"pmeaad4c54bib32","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1213\/ANE.0000000000003511","article-title":"Repeated measures designs and analysis of longitudinal data: if at first you do not succeed\u2014try, try again","volume":"127","author":"Schober","year":"2018","journal-title":"Anesth. Analg."},{"key":"pmeaad4c54bib33","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1080\/10739680590895028","article-title":"Regulation of blood flow in the microcirculation","volume":"12","author":"Segal","year":"2005","journal-title":"Microcirculation"},{"key":"pmeaad4c54bib34","doi-asserted-by":"publisher","first-page":"1801","DOI":"10.1007\/s00134-009-1570-9","article-title":"Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices","volume":"35","author":"Squara","year":"2009","journal-title":"Intensive Care Med."},{"key":"pmeaad4c54bib35","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1097\/TA.0000000000000423","article-title":"Detection of low-volume blood loss: compensatory reserve versus traditional vital signs","volume":"77","author":"Stewart","year":"2014","journal-title":"J. Trauma Acute Care Surg."},{"key":"pmeaad4c54bib36","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/s13534-019-00097-w","article-title":"Current progress of photoplethysmography and SpO2 for health monitoring","volume":"9","author":"Tamura","year":"2019","journal-title":"Biomed. Eng. Lett."},{"key":"pmeaad4c54bib37","doi-asserted-by":"publisher","first-page":"R792","DOI":"10.1152\/ajpregu.1990.259.4.R792","article-title":"Baroreflex responses to acute changes in blood volume in humans","volume":"259","author":"Thompson","year":"1990","journal-title":"Am. J. Physiol. Regul. Integr. Comp. Physiol."},{"key":"pmeaad4c54bib38","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1007\/s10877-018-0235-z","article-title":"Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study","volume":"33","author":"Tusman","year":"2019","journal-title":"J. Clin. Monit. Comput."},{"key":"pmeaad4c54bib39","doi-asserted-by":"publisher","first-page":"338","DOI":"10.23937\/2378-3656\/1410338","article-title":"Photoplethysmogram\u2019s amplitude is well correlated with beat-by-beat changes in arterial blood pressure","volume":"8","author":"Tusman","year":"2021","journal-title":"Clin. Med. Rev. Case Rep."},{"key":"pmeaad4c54bib40","doi-asserted-by":"publisher","first-page":"2727","DOI":"10.1111\/j.1537-2995.2011.03202.x","article-title":"Physiologic strategies to prevent fainting response during or after whole blood donation","volume":"52","author":"Wieling","year":"2011","journal-title":"Transfusion"},{"key":"pmeaad4c54bib41","first-page":"697","article-title":"Response of local vascular volumes to lower body negative pressure stress","volume":"46","author":"Wolthuis","year":"1975","journal-title":"Aviat. Space Environ. Med."}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,26]],"date-time":"2025-07-26T11:06:25Z","timestamp":1753527985000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4c54"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,1]]},"references-count":41,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2024,5,28]]},"published-print":{"date-parts":[[2024,5,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/ad4c54","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"type":"print","value":"0967-3334"},{"type":"electronic","value":"1361-6579"}],"subject":[],"published":{"date-parts":[[2024,5,1]]},"assertion":[{"value":"Finger photopletysmography detects early acute blood loss in compensated blood donors: a pilot study","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-02-14","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-15","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-28","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}