{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T14:40:08Z","timestamp":1790347208291,"version":"4.1.0"},"reference-count":79,"publisher":"IOP Publishing","issue":"6","license":[{"start":{"date-parts":[[2024,6,26]],"date-time":"2024-06-26T00:00:00Z","timestamp":1719360000000},"content-version":"vor","delay-in-days":25,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,6,26]],"date-time":"2024-06-26T00:00:00Z","timestamp":1719360000000},"content-version":"tdm","delay-in-days":25,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Endowed Manitoba Public Insurance (MPI) Chair in Neuroscience"},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"crossref","award":["NSERC; ALLRP-576386-22"],"award-info":[{"award-number":["NSERC; ALLRP-576386-22"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2024,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> Continuous monitoring of cerebrospinal compliance (CC)<jats:bold>\/<\/jats:bold> cerebrospinal compensatory reserve (CCR) is crucial for timely interventions and preventing more substantial deterioration in the context of acute neural injury, as it enables the early detection of abnormalities in intracranial pressure (ICP). However, to date, the literature on continuous CC\/CCR monitoring is scattered and occasionally challenging to consolidate. <jats:italic>Approach.<\/jats:italic> We subsequently conducted a systematic scoping review of the human literature to highlight the available continuous CC\/CCR monitoring methods. <jats:italic>Main results.<\/jats:italic> This systematic review incorporated a total number of 76 studies, covering diverse patient types and focusing on three primary continuous CC or CCR monitoring metrics and methods\u2014Moving Pearson\u2019s correlation between ICP pulse amplitude waveform and ICP, referred to as RAP, the Spiegelberg Compliance Monitor, changes in cerebral blood flow velocity with respect to the alternation of ICP measured through transcranial doppler (TCD), changes in centroid metric, high frequency centroid (HFC) or higher harmonics centroid (HHC), and the P2\/P1 ratio which are the distinct peaks of ICP pulse wave. The majority of the studies in this review encompassed RAP metric analysis (<jats:italic>n<\/jats:italic> = 43), followed by Spiegelberg Compliance Monitor (<jats:italic>n<\/jats:italic> = 11), TCD studies (<jats:italic>n<\/jats:italic> = 9), studies on the HFC\/HHC (<jats:italic>n<\/jats:italic> = 5), and studies on the P2\/P1 ratio studies (<jats:italic>n<\/jats:italic> = 6). These studies predominantly involved acute traumatic neural injury (i.e. Traumatic Brain Injury) patients and those with hydrocephalus. RAP is the most extensively studied of the five focused methods and exhibits diverse applications. However, most papers lack clarification on its clinical applicability, a circumstance that is similarly observed for the other methods. <jats:italic>Significance.<\/jats:italic> Future directions involve exploring RAP patterns and identifying characteristics and artifacts, investigating neuroimaging correlations with continuous CC\/CCR and integrating machine learning, holding promise for simplifying CC\/CCR determination. These approaches should aim to enhance the precision and accuracy of the metric, making it applicable in clinical practice.<\/jats:p>","DOI":"10.1088\/1361-6579\/ad4f4a","type":"journal-article","created":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T22:45:12Z","timestamp":1716417912000},"page":"06TR01","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["Continuous monitoring methods of cerebral compliance and compensatory reserve: a scoping review of human literature"],"prefix":"10.1088","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-6669-3374","authenticated-orcid":true,"given":"Abrar","family":"Islam","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Logan","family":"Froese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Bergmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3737-2065","authenticated-orcid":true,"given":"Alwyn","family":"Gomez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3231-5683","authenticated-orcid":true,"given":"Amanjyot Singh","family":"Sainbhi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nuray","family":"Vakitbilir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5983-008X","authenticated-orcid":true,"given":"Kevin Y","family":"Stein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Izabella","family":"Marquez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Younis","family":"Ibrahim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1737-0510","authenticated-orcid":true,"given":"Frederick A","family":"Zeiler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,6,26]]},"reference":[{"key":"pmeaad4f4abib1","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1007\/3-211-32318-x_64","article-title":"Preliminary report on spiegelberg pre and post-operative monitoring of severe head-injured patients who received decompressive craniectomy","volume":"95","author":"Abdullah","year":"2005","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib2","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s00701-003-0187-y","article-title":"Intracranial hypertension: what additional information can be derived from ICP waveform after head injury?","volume":"146","author":"Balestreri","year":"2004","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib3","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1007\/s10877-022-00941-y","article-title":"Noninvasive intracranial pressure waveforms for estimation of intracranial hypertension and outcome prediction in acute brain-injured patients","volume":"37","author":"Brasil","year":"2023","journal-title":"J. Clin. Monit Comput."},{"key":"pmeaad4f4abib4","doi-asserted-by":"publisher","first-page":"971","DOI":"10.3390\/brainsci11080971","article-title":"Intracranial compliance assessed by intracranial pressure pulse waveform","volume":"11","author":"Brasil","year":"2021","journal-title":"Brain Sci."},{"key":"pmeaad4f4abib5","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1007\/978-3-7091-0956-4_22","article-title":"Non-invasively estimated ICP pulse amplitude strongly correlates with outcome after TBI","volume":"114","author":"Budohoski","year":"2012","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib6","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1007\/s12028-017-0475-7","article-title":"Compensatory-reserve-weighted intracranial pressure and its association with outcome after traumatic brain injury","volume":"28","author":"Calviello","year":"2018","journal-title":"Neurocrit. Care"},{"key":"pmeaad4f4abib7","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1179\/1743132813Y.0000000282","article-title":"Cerebrovascular time constant in patients suffering from hydrocephalus","volume":"36","author":"Capel","year":"2014","journal-title":"Neurol. Res."},{"key":"pmeaad4f4abib8","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1111\/j.1552-6569.2009.00439.x","article-title":"Effect of hyper- and hypocapnia on cerebral arterial compliance in normal subjects","volume":"21","author":"Carrera","year":"2011a","journal-title":"J. Neuroimaging"},{"key":"pmeaad4f4abib9","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1111\/j.1468-1331.2010.03247.x","article-title":"Cerebral arterial compliance in patients with internal carotid artery disease","volume":"18","author":"Carrera","year":"2011b","journal-title":"Eur. J. Neurol."},{"key":"pmeaad4f4abib10","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1089\/neu.2010.1377","article-title":"Changes in cerebral compartmental compliances during mild hypocapnia in patients with traumatic brain injury","volume":"28","author":"Carrera","year":"2011","journal-title":"J. Neurotrauma"},{"key":"pmeaad4f4abib11","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/0165-0270(94)00106-q","article-title":"Intracranial pressure waveform indices in transient and refractory intracranial hypertension","volume":"57","author":"Contant","year":"1995","journal-title":"J. Neurosci. Methods"},{"key":"pmeaad4f4abib12","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1007\/BF01411173","article-title":"Significance of intracranial pressure waveform analysis after head injury","volume":"138","author":"Czosnyka","year":"1996","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib13","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1007\/BF01476419","article-title":"Monitoring of cerebrospinal dynamics using continuous analysis of intracranial pressure and cerebral perfusion pressure in head injury","volume":"126","author":"Czosnyka","year":"1994","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib14","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1007\/BF01402897","article-title":"Analysis of intracranial pressure waveform during infusion test","volume":"93","author":"Czosnyka","year":"1988","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib15","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1007\/s12028-019-00748-x","article-title":"Observations on the cerebral effects of refractory intracranial hypertension after severe traumatic brain injury","volume":"32","author":"Donnelly","year":"2020","journal-title":"Neurocrit. Care"},{"key":"pmeaad4f4abib16","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/1475-925X-12-14","article-title":"An intracranial pressure-derived index monitored simultaneously from two separate sensors in patients with cerebral bleeds: comparison of findings","volume":"12","author":"Eide","year":"2013","journal-title":"Biomed. Eng. Online"},{"key":"pmeaad4f4abib17","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1089\/neur.2020.0028","article-title":"The impact of vasopressor and sedative agents on cerebrovascular reactivity and compensatory reserve in traumatic brain injury: an exploratory analysis","volume":"1","author":"Froese","year":"2020","journal-title":"Neurotrauma Rep."},{"key":"pmeaad4f4abib18","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1007\/s00701-020-04662-6","article-title":"Sedation and cerebrovascular reactivity in traumatic brain injury: another potential avenue for personalized approaches in neurocritical care?","volume":"163","author":"Froese","year":"2021","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib19","doi-asserted-by":"publisher","DOI":"10.1590\/1414-431X2022e12150","article-title":"Intracranial compliance in type 2 diabetes mellitus and its relationship with the cardiovascular autonomic nervous control","volume":"55","author":"Galdino","year":"2022","journal-title":"Braz J. Med. Biol. Res."},{"key":"pmeaad4f4abib20","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2022.934731","article-title":"The quantitative associations between near infrared spectroscopic cerebrovascular metrics and cerebral blood flow: a scoping review of the human and animal literature","volume":"13","author":"Gomez","year":"2022","journal-title":"Front. Physiol."},{"key":"pmeaad4f4abib21","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1186\/s12987-021-00259-y","article-title":"Intracranial pressure waveform characteristics in idiopathic normal pressure hydrocephalus and late-onset idiopathic aqueductal stenosis","volume":"18","author":"Green","year":"2021","journal-title":"Fluids Barriers CNS"},{"key":"pmeaad4f4abib22","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0158506","article-title":"Ventricular volume load reveals the mechanoelastic impact of communicating hydrocephalus on dynamic cerebral autoregulation","volume":"11","author":"Haubrich","year":"2016a","journal-title":"PLoS One"},{"key":"pmeaad4f4abib23","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.medengphy.2014.11.009","article-title":"Traumatic brain injury: increasing ICP attenuates respiratory modulations of cerebral blood flow velocity","volume":"37","author":"Haubrich","year":"2015","journal-title":"Med. Eng. Phys."},{"key":"pmeaad4f4abib24","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1007\/978-3-319-22533-3_35","article-title":"Increasing intracranial pressure after head injury: impact on respiratory oscillations in cerebral blood flow velocity","volume":"122","author":"Haubrich","year":"2016b","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib25","doi-asserted-by":"publisher","first-page":"1521","DOI":"10.1016\/j.ultrasmedbio.2013.03.020","article-title":"Doppler flow velocity and intra-cranial pressure: responses to short-term mild hypocapnia help to assess the pressure-volume relationship after head injury","volume":"39","author":"Haubrich","year":"2013","journal-title":"Ultrasound Med. Biol."},{"key":"pmeaad4f4abib26","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1007\/s00134-012-2571-7","article-title":"An evaluation of three measures of intracranial compliance in traumatic brain injury patients","volume":"38","author":"Howells","year":"2012","journal-title":"Intensive Care Med."},{"key":"pmeaad4f4abib27","doi-asserted-by":"publisher","first-page":"71","DOI":"10.4266\/acc.2019.00437","article-title":"The RAP index during intracranial pressure monitoring as a clinical guiding for surgically treated aneurysmal subarachnoid hemorrhage: consecutive series of single surgeon","volume":"34","author":"Jin","year":"2019","journal-title":"Acute Crit. Care"},{"key":"pmeaad4f4abib28","doi-asserted-by":"publisher","first-page":"1979","DOI":"10.1007\/s00701-021-04834-y","article-title":"Compliance of the cerebrospinal space: comparison of three methods","volume":"163","author":"Kazimierska","year":"2021","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib29","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/978-3-7091-6738-0_46","article-title":"Intracranial compliance as a bed-side monitoring technique in severely head-injured patients","volume":"81","author":"Kiening","year":"2002","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib30","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1080\/02688690310001601199","article-title":"Continuous monitoring of intracranial compliance after severe head injury: relation to data quality, intracranial pressure and brain tissue PO2","volume":"17","author":"Kiening","year":"2003","journal-title":"Br. J. Neurosurg."},{"key":"pmeaad4f4abib31","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1007\/3-211-32318-x_60","article-title":"Assessment of the relationship between age and continuous intracranial compliance","volume":"95","author":"Brain-IT Group","year":"2005","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib32","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1179\/174313209X455673","article-title":"Cerebrospinal compensation of pulsating cerebral blood volume in hydrocephalus","volume":"32","author":"Kim","year":"2010","journal-title":"Neurol. Res."},{"key":"pmeaad4f4abib33","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1007\/s00701-015-2353-4","article-title":"Phase-shift between arterial flow and ICP pulse during infusion test","volume":"157","author":"Kim","year":"2015","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib34","doi-asserted-by":"publisher","first-page":"1354","DOI":"10.1089\/neu.2011.2018","article-title":"Continuous monitoring of the Monro-Kellie doctrine: is it possible?","volume":"29","author":"Kim","year":"2012","journal-title":"J. Neurotrauma"},{"key":"pmeaad4f4abib35","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1227\/01.NEU.0000338434.59141.89","article-title":"Index of cerebrospinal compensatory reserve in hydrocephalus","volume":"64","author":"Kim","year":"2009a","journal-title":"Neurosurgery"},{"key":"pmeaad4f4abib36","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1088\/0967-3334\/30\/7\/009","article-title":"The monitoring of relative changes in compartmental compliances of brain","volume":"30","author":"Kim","year":"2009b","journal-title":"Physiol. Meas."},{"key":"pmeaad4f4abib37","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1080\/01616412.1986.11739737","article-title":"Non-invasive measurement in intracranial pressure and analysis of the pulse waveform","volume":"8","author":"Kuramoto","year":"1986","journal-title":"Neurol. Res."},{"key":"pmeaad4f4abib38","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0164263","article-title":"The intracranial volume pressure response in increased intracranial pressure patients: clinical significance of the volume pressure indicator","volume":"11","author":"Lai","year":"2016","journal-title":"PLoS One"},{"key":"pmeaad4f4abib39","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s12987-020-00184-6","article-title":"Cerebrospinal fluid dynamics in non-acute post-traumatic ventriculomegaly","volume":"17","author":"Lalou","year":"2020","journal-title":"Fluids Barriers CNS"},{"key":"pmeaad4f4abib40","doi-asserted-by":"publisher","first-page":"214","DOI":"10.3171\/jns.2003.98.1.0214","article-title":"Noninvasive intracranial compliance monitoring. Technical note and clinical results","volume":"98","author":"Lang","year":"2003","journal-title":"J. Neurosurg."},{"key":"pmeaad4f4abib41","doi-asserted-by":"publisher","first-page":"2169","DOI":"10.1109\/TBME.2015.2512278","article-title":"Morphological feature extraction from a continuous intracranial pressure pulse via a peak clustering algorithm","volume":"63","author":"Lee","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaad4f4abib42","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/978-3-030-59436-7_66","article-title":"Differences in cerebrospinal fluid dynamics in posttraumatic hydrocephalus versus atrophy, including effect of decompression and cranioplasty","volume":"131","author":"Levrini","year":"2021","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib43","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2022.905655","article-title":"The application value of CT radiomics features in predicting pressure amplitude correlation index in patients with severe traumatic brain injury","volume":"13","author":"Liu","year":"2022","journal-title":"Front. Neurol."},{"key":"pmeaad4f4abib44","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1113\/EP089533","article-title":"Vasodilatation by carbon dioxide and sodium nitroglycerin reduces compliance of the cerebral arteries in humans","volume":"106","author":"Moir","year":"2021","journal-title":"Exp. Physiol."},{"key":"pmeaad4f4abib45","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1007\/978-3-319-22533-3_7","article-title":"Characterisation of supra- and infratentorial ICP profiles","volume":"122","author":"Moyse","year":"2016","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib46","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1007\/3-211-32318-x_61","article-title":"Cerebral haemodynamic assessment in patients with thalamic haemorrhage: a pilot study with continuous compliance monitoring","volume":"95","author":"Ng","year":"2005","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib47","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/s00701-015-2672-5","article-title":"Intracranial pressure wave morphological classification: automated analysis and clinical validation","volume":"158","author":"Nucci","year":"2016","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib48","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.jclinepi.2019.11.010","article-title":"Mapping of reporting guidance for systematic reviews and meta-analyses generated a comprehensive item bank for future reporting guidelines","volume":"118","author":"Page","year":"2020","journal-title":"J. Clin. Epidemiol."},{"key":"pmeaad4f4abib49","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1111\/j.1600-0404.2008.01041.x","article-title":"How does CSF dynamics change after shunting?","volume":"118","author":"Petrella","year":"2008","journal-title":"Acta Neurol. Scand."},{"key":"pmeaad4f4abib50","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/NEBEC.2015.7117187","article-title":"Developing a continuous hemodynamic autoregulation monitor","author":"Pineda","year":"2015"},{"key":"pmeaad4f4abib51","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1007\/978-3-319-65798-1_58","article-title":"Assessing cerebral hemodynamic stability after brain injury","volume":"126","author":"Pineda","year":"2018","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib52","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1080\/02688699943097","article-title":"A comparative study of the Spiegelberg compliance device with a manual volume-injection method: a clinical evaluation in patients with hydrocephalus","volume":"13","author":"Piper","year":"1999","journal-title":"Br. J. Neurosurg."},{"key":"pmeaad4f4abib53","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1007\/s00701-005-0537-z","article-title":"Continuous cerebral compliance monitoring in severe head injury: its relationship with intracranial pressure and cerebral perfusion pressure","volume":"147","author":"Portella","year":"2005","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib54","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1007\/s007010050263","article-title":"Monitoring of intracranial compliance: correction for a change in body position","volume":"141","author":"Raabe","year":"1999","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib55","doi-asserted-by":"publisher","first-page":"673","DOI":"10.3171\/jns.1989.71.5.0673","article-title":"Clinical experience with a continuous monitor of intracranial compliance","volume":"71","author":"Robertson","year":"1989","journal-title":"J. Neurosurg."},{"key":"pmeaad4f4abib56","doi-asserted-by":"publisher","first-page":"07TR02","DOI":"10.1088\/1361-6579\/acdfb6","article-title":"Regional disparity in continuously measured time-domain cerebrovascular reactivity indices: a scoping review of human literature","volume":"44","author":"Sainbhi","year":"2023","journal-title":"Physiol. Meas."},{"key":"pmeaad4f4abib57","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s10877-006-2864-x","article-title":"Intracerebral microdialysis and intracranial compliance monitoring of patients with traumatic brain injury","volume":"20","author":"Salci","year":"2006","journal-title":"J. Clin. Monit Comput."},{"key":"pmeaad4f4abib58","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1159\/000131675","article-title":"Value of overnight monitoring of intracranial pressure in hydrocephalic children","volume":"44","author":"Schuhmann","year":"2008","journal-title":"Pediatr. Neurosurg."},{"key":"pmeaad4f4abib59","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.resuscitation.2019.05.036","article-title":"Intracranial pressure and compliance in hypoxic ischemic brain injury patients after cardiac arrest","volume":"141","author":"Sekhon","year":"2019","journal-title":"Resuscitation"},{"key":"pmeaad4f4abib60","doi-asserted-by":"publisher","first-page":"2072","DOI":"10.1109\/TBME.2011.2142415","article-title":"Cerebrovascular mechanical properties and slow waves of intracranial pressure in TBI patients","volume":"58","author":"Shahsavari","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaad4f4abib61","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/978-3-211-85578-2_2","article-title":"A comparison between the transfer function of ABP to ICP and compensatory reserve index in TBI","volume":"102","author":"Shahsavari","year":"2008","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib62","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1007\/978-3-211-85578-2_30","article-title":"ICM+, a flexible platform for investigations of cerebrospinal dynamics in clinical practice","volume":"102","author":"Smielewski","year":"2008","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib63","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1007\/978-3-7091-0956-4_41","article-title":"Lack of correlation of overnight monitoring data and lumbar infusion data in iNPH patients","volume":"114","author":"Speil","year":"2012","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib64","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1007\/s00701-005-0510-x","article-title":"Predicting the response of intracranial pressure to moderate hyperventilation","volume":"147","author":"Steiner","year":"2005","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib65","doi-asserted-by":"publisher","first-page":"66","DOI":"10.3171\/JNS\/2008\/108\/01\/0066","article-title":"Effect of decompressive craniectomy on intracranial pressure and cerebrospinal compensation following traumatic brain injury","volume":"108","author":"Timofeev","year":"2008a","journal-title":"J. Neurosurg."},{"key":"pmeaad4f4abib66","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1007\/978-3-211-85578-2_20","article-title":"Ventriculostomy for control of raised ICP in acute traumatic brain injury","volume":"102","author":"Timofeev","year":"2008b","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib67","doi-asserted-by":"publisher","first-page":"467","DOI":"10.7326\/M18-0850","article-title":"PRISMA extension for scoping reviews (PRISMA-ScR): checklist and explanation","volume":"169","author":"Tricco","year":"2018","journal-title":"Ann. Intern. Med."},{"key":"pmeaad4f4abib68","doi-asserted-by":"publisher","first-page":"201","DOI":"10.3171\/2022.10.JNS221523","article-title":"CENTER-TBI high-resolution ICU (HR ICU) sub-study participants and investigators; CENTER-TBI high-resolution sub-study participants and investigators. Analysis of intracranial pressure pulse waveform in traumatic brain injury patients: a CENTER-TBI study","volume":"139","author":"Uryga","year":"2022","journal-title":"J. Neurosurg."},{"key":"pmeaad4f4abib69","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1179\/1743132815Y.0000000044","article-title":"Cerebral critical closing pressure in hydrocephalus patients undertaking infusion tests","volume":"37","author":"Varsos","year":"2015","journal-title":"Neurol. Res."},{"key":"pmeaad4f4abib70","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1111\/j.1600-0404.2010.01467.x","article-title":"Clinical assessment of cerebrospinal fluid dynamics in hydrocephalus. Guide to interpretation based on observational study","volume":"124","author":"Weerakkody","year":"2011","journal-title":"Acta Neurol. Scand."},{"key":"pmeaad4f4abib71","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1007\/s12028-020-01004-3","article-title":"Assessment of dynamic intracranial compliance in children with severe traumatic brain injury: proof-of-concept","volume":"34","author":"Wolf","year":"2021","journal-title":"Neurocrit. Care"},{"key":"pmeaad4f4abib72","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1007\/978-3-7091-6738-0_44","article-title":"Clinical experience in the use of the Spiegelberg automated compliance device in the assessment of patients with hydrocephalus","volume":"81","author":"Yau","year":"2002","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib73","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/3-211-32318-x_59","article-title":"Assessment of different data representations and averaging methods on the Spiegelberg compliance device","volume":"95","author":"Brain IT Group","year":"2005","journal-title":"Acta Neurochir. Suppl."},{"key":"pmeaad4f4abib74","doi-asserted-by":"publisher","first-page":"3249","DOI":"10.1007\/s00701-021-04958-1","article-title":"Intracranial pulse pressure waveform analysis using the higher harmonics centroid","volume":"163","author":"Zakrzewska","year":"2021","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib75","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1089\/neu.2017.5241","article-title":"A description of a new continuous physiological index in traumatic brain injury using the correlation between pulse amplitude of intracranial pressure and cerebral perfusion pressure","volume":"35","author":"Zeiler","year":"2018a","journal-title":"J. Neurotrauma"},{"key":"pmeaad4f4abib76","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1007\/s00701-019-03915-3","article-title":"CENTER-TBI high resolution ICU sub-study participants and investigators. Compensatory-reserve-weighted intracranial pressure versus intracranial pressure for outcome association in adult traumatic brain injury: a CENTER-TBI validation study","volume":"161","author":"Zeiler","year":"2019","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib77","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1007\/s00701-018-3681-y","article-title":"Impaired cerebral compensatory reserve is associated with admission imaging characteristics of diffuse insult in traumatic brain injury","volume":"160","author":"Zeiler","year":"2018b","journal-title":"Acta Neurochir."},{"key":"pmeaad4f4abib78","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2022.1043328","article-title":"Spindle wave in intracranial pressure signal analysis for patients with traumatic brain injury: a single-center prospective observational cohort study","volume":"13","author":"Zhu","year":"2023","journal-title":"Front. Physiol."},{"key":"pmeaad4f4abib79","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/ac38bf","article-title":"Analysis of relative changes in pulse shapes of intracranial pressure and cerebral blood flow velocity","volume":"42","author":"Zi\u00f3\u0142kowski","year":"2021","journal-title":"Physiol. Meas."}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,26]],"date-time":"2024-06-26T13:05:35Z","timestamp":1719407135000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/ad4f4a"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,1]]},"references-count":79,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024,6,26]]},"published-print":{"date-parts":[[2024,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/ad4f4a","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,1]]},"assertion":[{"value":"Continuous monitoring methods of cerebral compliance and compensatory reserve: a scoping review of human literature","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-01-11","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-22","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-06-26","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}