{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T20:20:53Z","timestamp":1783974053600,"version":"3.55.0"},"reference-count":34,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T00:00:00Z","timestamp":1738108800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T00:00:00Z","timestamp":1738108800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100003074","name":"Agencia Nacional de Promoci\u00f3n Cient\u00edfica y Tecnol\u00f3gica","doi-asserted-by":"crossref","award":["PICT 2019 N\u00ba1563"],"award-info":[{"award-number":["PICT 2019 N\u00ba1563"]}],"id":[{"id":"10.13039\/501100003074","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2025,1,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objectives.<\/jats:italic> Aortic dilatation is a severe pathology that increases the risk of rupture and its hemodynamics could be accurately assessed by using the 4D flow cardiovascular magnetic resonance (CMR) technique but flow assessment under complex flow patterns require validation. The aim of this work was to develop an <jats:italic>in vitro<\/jats:italic> system compatible with CMR to assess the accuracy of volume flow measurements in dilated aortas. <jats:italic>Approach.<\/jats:italic> Two latex models, one with ascending and the other with abdominal aortic aneurysms were manufactured to ensure a constant and controlled net flow volume along the aortic length. A pneumatic piston driven by a stepper motor and controlled by an embedded system located in the control room modulated a pulsatile fluid flow using a pump with an elastic membrane placed in the magnet near the elastic models. All the visualization and measurement algorithms were integrated into a custom computer platform. 4D flow imaging was used to estimate the flow rate and volume through multiple aortic planes and compared to the reference assessed by weight method and to 2D flow measurements. <jats:italic>Main results.<\/jats:italic> The errors of flow volume assessment using 4D flow remained within reasonable limits along the length of the aortic models. Mean differences in net flow volume from the reference were less than 2 ml (range \u22124 to 6 ml), corresponding to mean relative differences of less than 4% (range \u22128% to 11%). Averaged net, forward and backward flow volume estimations along the aortic length were similar using 2D and 4D flow measurements (<jats:italic>p<\/jats:italic> &gt; 0.05). Peak forward and backward flow rates increased in the dilated regions and were comparable to those observed in patients. <jats:italic>Significance.<\/jats:italic> The accuracy of flow volume estimates in complex flow patterns, such as those observed in patients with aneurysms, was validated <jats:italic>in vitro<\/jats:italic> using 4D flow.<\/jats:p>","DOI":"10.1088\/1361-6579\/adab4e","type":"journal-article","created":{"date-parts":[[2025,1,16]],"date-time":"2025-01-16T23:00:09Z","timestamp":1737068409000},"page":"015006","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Accuracy of flow volume estimation in the dilated aorta using 4D flow MRI: a pulsatile phantom study"],"prefix":"10.1088","volume":"46","author":[{"given":"Eduardo E","family":"Rodr\u00edguez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3151-2119","authenticated-orcid":true,"given":"Alejandro","family":"Valda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6793-1502","authenticated-orcid":false,"given":"Mariano E","family":"Casciaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Graf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edmundo Cabrera","family":"Fischer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1065-799X","authenticated-orcid":true,"given":"Damian","family":"Craiem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,1,29]]},"reference":[{"key":"pmeaadab4ebib1","doi-asserted-by":"publisher","DOI":"10.1115\/1.4062539","article-title":"Framework development for patient-specific compliant aortic dissection phantom model fabrication: magnetic resonance imaging validation and deep-learning segmentation","volume":"145","author":"Aghilinejad","year":"2023","journal-title":"J. Biomech. Eng."},{"key":"pmeaadab4ebib2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0267765","article-title":"A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: design, fabrication, and physiological relevancy","volume":"17","author":"Alavi","year":"2022","journal-title":"PLoS One"},{"key":"pmeaadab4ebib3","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/s13246-019-00728-7","article-title":"Computational study on hemodynamic changes in patient-specific proximal neck angulation of abdominal aortic aneurysm with time-varying velocity","volume":"42","author":"Algabri","year":"2019","journal-title":"Australas. Phys. Eng. Sci. Med."},{"key":"pmeaadab4ebib4","doi-asserted-by":"publisher","first-page":"1381","DOI":"10.1161\/CIRCULATIONAHA.118.038809","article-title":"Abdominal aortic aneurysm screening is safe yet lacks effectiveness","volume":"139","author":"Arnaoutakis","year":"2019","journal-title":"Circulation"},{"key":"pmeaadab4ebib5","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/s12968-023-00942-z","article-title":"4D Flow cardiovascular magnetic resonance consensus statement: 2023 update","volume":"25","author":"Bissell","year":"2023","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"pmeaadab4ebib6","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/s13239-013-0146-6","article-title":"A review on computational fluid dynamics modelling in human thoracic aorta","volume":"4","author":"Caballero","year":"2013","journal-title":"Cardiovasc. Eng. Technol."},{"key":"pmeaadab4ebib7","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1097\/RTI.0000000000000060","article-title":"Identifying the principal modes of variation in human thoracic aorta morphology","volume":"29","author":"Casciaro","year":"2014","journal-title":"J. Thorac. Imaging"},{"key":"pmeaadab4ebib8","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/abe525","article-title":"4D flow MRI: impact of region of interest size, angulation and spatial resolution on aortic flow assessment","volume":"42","author":"Casciaro","year":"2021","journal-title":"Physiol. Meas."},{"key":"pmeaadab4ebib9","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.pcad.2013.05.007","article-title":"Natural history of thoracic aortic aneurysms: size matters, plus moving beyond size","volume":"56","author":"Chau","year":"2013","journal-title":"Prog. Cardiovasc. Dis."},{"key":"pmeaadab4ebib10","doi-asserted-by":"publisher","DOI":"10.1148\/ryct.2020190054","article-title":"4D flow vorticity visualization predicts regions of quantitative flow inconsistency for optimal blood flow measurement","volume":"2","author":"Contijoch","year":"2020","journal-title":"Radiology"},{"key":"pmeaadab4ebib11","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1007\/s10334-019-00765-z","article-title":"Automatic correction of background phase offset in 4D-flow of great vessels and of the heart in MRI using a third-order surface model","volume":"32","author":"Craiem","year":"2019","journal-title":"Magn. Reson. Mater. Phys. Biol. Med."},{"key":"pmeaadab4ebib12","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.diii.2018.08.012","article-title":"In-vitro validation of 4D flow MRI measurements with an experimental pulsatile flow model","volume":"100","author":"David","year":"2019","journal-title":"Diagn. Interv. Imaging"},{"key":"pmeaadab4ebib13","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.suc.2010.10.007","article-title":"Computed tomography for the diagnosis and management of abdominal aortic aneurysms","volume":"91","author":"Davis","year":"2011","journal-title":"Surg. Clin. North Am."},{"key":"pmeaadab4ebib14","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1186\/s12968-015-0174-5","article-title":"4D flow cardiovascular magnetic resonance consensus statement","volume":"17","author":"Dyverfeldt","year":"2015","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"pmeaadab4ebib15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41747-019-0089-2","article-title":"Validation of two accelerated 4D flow MRI sequences at 3 T: a phantom study","volume":"3","author":"Ebel","year":"2019","journal-title":"Eur. Radiol. Exp."},{"key":"pmeaadab4ebib16","doi-asserted-by":"publisher","first-page":"2873","DOI":"10.1093\/eurheartj\/ehu281","article-title":"2014 ESC guidelines on the diagnosis and treatment of aortic diseases: document covering acute and chronic aortic diseases of the thoracic and abdominal aorta of the adult. The task force for the diagnosis and treatment of aortic diseases of the european society of cardiology (ESC)","volume":"35","author":"Erbel","year":"2014","journal-title":"Eur. Heart J."},{"key":"pmeaadab4ebib17","doi-asserted-by":"publisher","first-page":"311","DOI":"10.2463\/mrms.mp.2016-0060","article-title":"Influence of spatial resolution in three-dimensional cine phase contrast magnetic resonance imaging on the accuracy of hemodynamic analysis","volume":"16","author":"Fukuyama","year":"2017","journal-title":"Magn. Reson. Med. Sci."},{"key":"pmeaadab4ebib18","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1002\/jmri.25746","article-title":"Comparison of fast acquisition strategies in whole\u2010heart four\u2010dimensional flow cardiac MR: two\u2010center, 1.5 Tesla, phantom and in vivo validation study","volume":"47","author":"Garg","year":"2018","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmeaadab4ebib19","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1177\/0954411919859994","article-title":"The speed, reflection and intensity of waves propagating in flexible tubes with aneurysm and stenosis: experimental investigation","volume":"233","author":"Hacham","year":"2019","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"pmeaadab4ebib20","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1016\/j.rcl.2020.02.009","article-title":"Imaging thoracic aortic aneurysm","volume":"58","author":"Kallianos","year":"2020","journal-title":"Radiol. Clin. North Am."},{"key":"pmeaadab4ebib21","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1111\/cgf.12669","article-title":"Robust cardiac function assessment in 4D PC-MRI data of the aorta and pulmonary artery","volume":"35","author":"K\u00f6hler","year":"2016","journal-title":"Comput. Graph. Forum"},{"key":"pmeaadab4ebib22","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/j.diii.2024.09.001","article-title":"Flow quantification within the aortic ejection tract using 4D flow cardiac MRI in patients with bicuspid aortic valve: implications for the assessment of aortic regurgitation","volume":"105","author":"Nguyen","year":"2024","journal-title":"Diagn. Interv. Imaging"},{"key":"pmeaadab4ebib23","doi-asserted-by":"publisher","first-page":"798","DOI":"10.1016\/j.jtcvs.2019.02.127","article-title":"Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D flow MRI) reveals altered blood flow patterns in the ascending aorta of patients with valve-sparing aortic root replacement","volume":"159","author":"Oechtering","year":"2020","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"pmeaadab4ebib24","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1016\/j.avsg.2019.04.032","article-title":"Computational fluid dynamics modeling of hemodynamic parameters in the human diseased aorta: a systematic review","volume":"63","author":"Ong","year":"2020","journal-title":"Ann. Vasc. Surg."},{"key":"pmeaadab4ebib25","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1097\/RLI.0000000000000768","article-title":"Characterization of ascending aortic flow in patients with degenerative aneurysms: a 4D flow magnetic resonance study","volume":"56","author":"Ramaekers","year":"2021","journal-title":"Invest. Radiol."},{"key":"pmeaadab4ebib26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41205-021-00114-8","article-title":"Compliant vascular models 3D printed with the Stratasys J750: a direct characterization of model distensibility using intravascular ultrasound","volume":"7","author":"Sparks","year":"2021","journal-title":"3D Print. Med."},{"key":"pmeaadab4ebib27","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1002\/mrm.21778","article-title":"Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters","volume":"60","author":"Stalder","year":"2008","journal-title":"Magn. Reson. Med."},{"key":"pmeaadab4ebib28","doi-asserted-by":"publisher","first-page":"327","DOI":"10.2463\/mrms.rev.2021-0046","article-title":"Utility of 4D flow MRI in thoracic aortic diseases: a literature review of clinical applications and current evidence","volume":"21","author":"Takahashi","year":"2022","journal-title":"Magn. Reson. Med. Sci."},{"key":"pmeaadab4ebib29","doi-asserted-by":"publisher","first-page":"354","DOI":"10.2463\/mrms.rev.2021-0156","article-title":"Clinical application of 4D flow MR imaging for the abdominal aorta","volume":"21","author":"Takehara","year":"2022","journal-title":"Magn. Reson. Med. Sci."},{"key":"pmeaadab4ebib30","first-page":"4","article-title":"Catmull-rom splines","volume":"41","author":"Twigg","year":"2003","journal-title":"Computer"},{"key":"pmeaadab4ebib31","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1002\/jmri.25208","article-title":"Realistic aortic phantom to study hemodynamics using MRI and cardiac catheterization in normal and aortic coarctation conditions","volume":"44","author":"Urbina","year":"2016","journal-title":"J. Magn. Reson. Imaging"},{"key":"pmeaadab4ebib32","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.1097\/MAT.0000000000001651","article-title":"High-versatility left ventricle pump and aortic mock circulatory loop development for patient-specific hemodynamic in vitro analysis","volume":"68","author":"Vignali","year":"2022","journal-title":"ASAIO J."},{"key":"pmeaadab4ebib33","author":"Weiskopf","year":"2007"},{"key":"pmeaadab4ebib34","doi-asserted-by":"publisher","first-page":"6703","DOI":"10.1038\/s41598-021-86174-6","article-title":"On the impact of vessel wall stiffness on quantitative flow dynamics in a synthetic model of the thoracic aorta","volume":"11","author":"Zimmermann","year":"2021","journal-title":"Sci. Rep."}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T11:02:58Z","timestamp":1741863778000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adab4e"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,29]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,1,29]]},"published-print":{"date-parts":[[2025,1,31]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/adab4e","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"value":"0967-3334","type":"print"},{"value":"1361-6579","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,29]]},"assertion":[{"value":"Accuracy of flow volume estimation in the dilated aorta using 4D flow MRI: a pulsatile phantom study","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-10-29","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-01-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-01-29","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}