{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T10:49:45Z","timestamp":1761130185132,"version":"3.40.3"},"reference-count":20,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T00:00:00Z","timestamp":1743379200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T00:00:00Z","timestamp":1743379200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000006","name":"Office of Naval Research","doi-asserted-by":"crossref","award":["N000142312002"],"award-info":[{"award-number":["N000142312002"]}],"id":[{"id":"10.13039\/100000006","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2025,3,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> Electrical impedance tomography (EIT) has shown the ability to provide clinically useful functional information on ventilation in humans and other land mammals. We are motivated to use EIT with sea mammals and human divers, since EIT could provide unique information on lung ventilation that can help address diver performance and safety, and veterinary and behavioral questions. However, in-water use of EIT is challenging, primarily because sea water is more conductive than the body. <jats:italic>Approach.<\/jats:italic> We first address this issue by modeling the in-water component and evaluating image reconstruction algorithms. <jats:italic>Main results.<\/jats:italic> EIT is able to produce reasonable images if an outer insulating layer allows a water layer thickness &lt;2% of the body radius. We next describe the design of custom EIT belts with an outer neoprene insulator to minimize current leakage. We show example underwater EIT recordings in human and dolphin subjects. <jats:italic>Significance.<\/jats:italic> We demonstrate in-water EIT is feasible with appropriate techniques.<\/jats:p>","DOI":"10.1088\/1361-6579\/adb82c","type":"journal-article","created":{"date-parts":[[2025,2,19]],"date-time":"2025-02-19T22:57:02Z","timestamp":1740005822000},"page":"03NT01","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["In-water electrical impedance tomography: EIT and the sea"],"prefix":"10.1088","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2312-5346","authenticated-orcid":true,"given":"Andy","family":"Adler","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tarek","family":"El Harake","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martina","family":"Mosing","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8675-6479","authenticated-orcid":true,"given":"Andreas","family":"Fahlman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2025,3,31]]},"reference":[{"key":"pmeaadb82cbib1","doi-asserted-by":"publisher","first-page":"S35","DOI":"10.1088\/0967-3334\/30\/6\/S03","article-title":"GREIT: a unified approach to 2D linear EIT reconstruction of lung images","volume":"30","author":"Adler","year":"2009","journal-title":"Physiol. Meas."},{"key":"pmeaadb82cbib2","doi-asserted-by":"publisher","first-page":"p 68","DOI":"10.1016\/j.gie.2020.06.015","article-title":"Feasibility of thoracic impedance measurements in seawater","author":"Adler","year":"2021"},{"key":"pmeaadb82cbib3","doi-asserted-by":"publisher","first-page":"p 42","DOI":"10.5281\/zenodo.13316995","article-title":"EIT monitoring of breathing dolphins","author":"Adler","year":"2024"},{"key":"pmeaadb82cbib4","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1088\/0967-3334\/27\/5\/S03","article-title":"Uses and abuses of EIDORS: an extensible software base for EIT","volume":"27","author":"Adler","year":"2006","journal-title":"Physiol. Meas."},{"key":"pmeaadb82cbib5","doi-asserted-by":"publisher","DOI":"10.3389\/fvets.2022.946911","article-title":"Thoracic electrical impedance tomography\u2014the 2022 veterinary guidelines statement","volume":"9","author":"EIT consensus group","year":"2022","journal-title":"Front. Vet. Sci."},{"key":"pmeaadb82cbib6","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1109\/10.35300","article-title":"Electrode models for electric current computed tomography","volume":"36","author":"Cheng","year":"1989","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"pmeaadb82cbib7","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.669158","article-title":"The new era of physio-logging and their grand challenges","volume":"12","author":"Fahlman","year":"2021b","journal-title":"Front. Physiol."},{"key":"pmeaadb82cbib8","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1113\/EP091095","article-title":"Cardiorespiratory adaptations in small cetaceans and marine mammals","volume":"109","author":"Fahlman","year":"2024","journal-title":"Exp. Physiol."},{"key":"pmeaadb82cbib9","doi-asserted-by":"publisher","DOI":"10.1242\/jeb.226365","article-title":"Cardiorespiratory coupling in cetaceans; a physiological strategy to improve gas exchange?","volume":"223","author":"Fahlman","year":"2020","journal-title":"J. Exp. Biol."},{"key":"pmeaadb82cbib10","doi-asserted-by":"publisher","DOI":"10.3389\/fmars.2021.598633","article-title":"How do marine mammals manage and usually avoid gas emboli formation and gas embolic pathology? Critical clues from studies of wild dolphins","volume":"8","author":"Fahlman","year":"2021a","journal-title":"Front. Mar. Sci."},{"key":"pmeaadb82cbib11","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","article-title":"Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group","volume":"72","author":"Frerichs","year":"2017","journal-title":"Thorax"},{"key":"pmeaadb82cbib12","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1152\/jappl.2001.91.1.39","article-title":"Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights","volume":"91","author":"Frerichs","year":"2001","journal-title":"J. Appl. Physiol."},{"key":"pmeaadb82cbib13","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/ab291d","article-title":"Thoracic EIT in 3D \u2212 experiences and recommendations","volume":"40","author":"Grychtol","year":"2019","journal-title":"Physiol. Meas."},{"key":"pmeaadb82cbib14","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1109\/TBME.2008.2003103","article-title":"Real-time management of faulty electrodes in electrical impedance tomography","volume":"56","author":"Hartinger","year":"2008","journal-title":"IEEE Trans. Biomed. Eng."},{"year":"1952","author":"Hemmingway","key":"pmeaadb82cbib15"},{"key":"pmeaadb82cbib16","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1080\/02640410903121351","article-title":"Decompression sickness in breath-hold divers: a review","volume":"27","author":"Lemaitre","year":"2009","journal-title":"J. Sports Sci."},{"key":"pmeaadb82cbib17","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1007\/s007910050004","article-title":"NETGEN: an advancing front 2D\/3D-mesh generator based on abstract rules","volume":"1","author":"Sch\u00f6berl","year":"1997","journal-title":"Comput. Vis. Sci."},{"key":"pmeaadb82cbib18","first-page":"1","article-title":"Development of an electro impedance tomography-based platform for measurement of burial depth of cables in subsea sediments","author":"Schuldei","year":"2019"},{"key":"pmeaadb82cbib19","first-page":"520","article-title":"Underwater object tracking using electrical impedance tomography","author":"Snyder","year":"2012"},{"key":"pmeaadb82cbib20","doi-asserted-by":"publisher","first-page":"9916","DOI":"10.1038\/s41598-018-27931-y","article-title":"Three-stage vertical distribution of seawater conductivity","volume":"8","author":"Zheng","year":"2018","journal-title":"Sci. Rep."}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T17:43:25Z","timestamp":1743443005000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adb82c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,31]]},"references-count":20,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,3,31]]},"published-print":{"date-parts":[[2025,3,31]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/adb82c","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"type":"print","value":"0967-3334"},{"type":"electronic","value":"1361-6579"}],"subject":[],"published":{"date-parts":[[2025,3,31]]},"assertion":[{"value":"In-water electrical impedance tomography: EIT and the sea","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-11-01","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-02-19","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-03-31","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}