{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T07:40:05Z","timestamp":1749195605230,"version":"3.41.0"},"reference-count":28,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"vor","delay-in-days":7,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"tdm","delay-in-days":7,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Physiol. Meas."],"published-print":{"date-parts":[[2025,5,30]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> Monitoring the volume status of patients remains a fundamentally unresolved issue in the perioperative setting but also in intensive care medicine. Electrical impedance tomography (EIT) enables noninvasive and radiation-free functional imaging of impedance changes of a cross-sectional plane of the thorax. <jats:italic>Approach.<\/jats:italic> We hypothesized that cardiac-induced impedance fluctuations in the EIT signal contain information about the global volume status. Therefore, we recorded EIT signals from 24 healthy volunteers before and up to 100 min after ingestion of 750 ml liquid following more than nine hours fluid restriction. We isolated a characteristic cardiac-induced impedance profile from the global impedance curve and compared its characteristics to measures of non-invasive hemodynamic monitoring and the diameter of the vena cava inferior (VCI) determined via ultrasonography. <jats:italic>Main results.<\/jats:italic> The diameter of the VCI, mean arterial pressure and stroke volume index, did not change systematically after liquid ingestion. Heart rate was increased 20 min after, and heart rate variability was increased immediately after liquid ingestion. The amplitude, the area under the curve and gradients of its rise and decline of the characteristic cardiac-induced impedance profile changed 60 min after liquid ingestion. <jats:italic>Significance.<\/jats:italic> Cardiac-induced pulsatile signals in EIT recordings changed characteristically after liquid ingestion, loosely corresponding with changes in heart rate and heart rate variability. These signals may contain valuable information about the general volume status and may be utilized for enhanced monitoring of a patient\u2019s volume status.<\/jats:p>","DOI":"10.1088\/1361-6579\/adda8d","type":"journal-article","created":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T22:53:12Z","timestamp":1747695192000},"page":"055002","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Approaching volume status via electrical impedance tomography\u2014an explorative study in healthy volunteers<sup>*<\/sup>"],"prefix":"10.1088","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-6469-0753","authenticated-orcid":true,"given":"Sophie","family":"W\u00f6lbert","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0104-7287","authenticated-orcid":true,"given":"Johannes","family":"Hell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0773-7489","authenticated-orcid":true,"given":"Stefan","family":"Schumann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2025,6,6]]},"reference":[{"article-title":"S3-Leitlinie intravasale volumentherapie bei Erwachsenen AWMF-registernummer 001\u2013020","year":"2020","author":"Anon","key":"pmeaadda8dbib1"},{"key":"pmeaadda8dbib2","doi-asserted-by":"publisher","first-page":"1538","DOI":"10.1097\/CCM.0000000000002554","article-title":"Incorporating dynamic assessment of fluid responsiveness into goal-directed therapy: a systematic review and meta-analysis","volume":"45","author":"Bednarczyk","year":"2017","journal-title":"Crit. Care Med."},{"key":"pmeaadda8dbib3","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1093\/bja\/aet116","article-title":"Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients","volume":"111","author":"Bendjelid","year":"2013","journal-title":"Br. J. Anaesth."},{"key":"pmeaadda8dbib4","doi-asserted-by":"publisher","first-page":"R118","DOI":"10.1186\/cc9070","article-title":"Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study","volume":"14","author":"Benes","year":"2010","journal-title":"Crit. Care"},{"key":"pmeaadda8dbib5","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1088\/0967-3334\/33\/7\/1225","article-title":"Influence of crystalloid and colloid fluid infusion and blood withdrawal on pulmonary bioimpedance in an animal model of mechanical ventilation","volume":"33","author":"Bodenstein","year":"2012","journal-title":"Physiol. Meas."},{"key":"pmeaadda8dbib6","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/ac7cc3","article-title":"Lung area estimation using functional tidal electrical impedance variation images and active contouring","volume":"43","author":"Borgmann","year":"2022","journal-title":"Physiol. Meas."},{"key":"pmeaadda8dbib7","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1007\/s10877-019-00402-z","article-title":"Noninvasive measurement of stroke volume changes in critically ill patients by means of electrical impedance tomography","volume":"34","author":"Braun","year":"2019","journal-title":"J. Clin. Monit. Comput."},{"key":"pmeaadda8dbib8","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1097\/EJA.0000000000000778","article-title":"Does goal-directed haemodynamic and fluid therapy improve peri-operative outcomes?: a systematic review and meta-analysis","volume":"35","author":"Chong","year":"2018","journal-title":"Eur. J. Anaesthesiol."},{"key":"pmeaadda8dbib9","doi-asserted-by":"publisher","DOI":"10.1183\/13993003.01497-2019","article-title":"Electrical impedance tomography for chest imaging in acute respiratory failure","volume":"54","author":"Frerichs","year":"2019","journal-title":"Eur. Respir. J."},{"key":"pmeaadda8dbib10","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.1111\/j.1399-6576.2011.02511.x","article-title":"Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography","volume":"55","author":"Grivans","year":"2011","journal-title":"Acta Anaesthesiol. Scand."},{"key":"pmeaadda8dbib11","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1007\/s00540-023-03256-7","article-title":"Stroke volume variation and dynamic arterial elastance predict fluid responsiveness even in thoracoscopic esophagectomy: a prospective observational study","volume":"37","author":"Hikasa","year":"2023","journal-title":"J. Anesth."},{"key":"pmeaadda8dbib12","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1016\/j.bja.2021.10.046","article-title":"Goal-directed haemodynamic therapy during general anaesthesia for noncardiac surgery: a systematic review and meta-analysis","volume":"128","author":"Jessen","year":"2022","journal-title":"Br. J. Anaesth."},{"key":"pmeaadda8dbib13","first-page":"1208","article-title":"Development and evaluation of an impedance cardiac output system","volume":"37","author":"Kubicek","year":"1966","journal-title":"Aerosp. Med."},{"key":"pmeaadda8dbib14","doi-asserted-by":"publisher","first-page":"26","DOI":"10.21037\/atm.2017.12.06","article-title":"Electrical impedance tomography","volume":"6","author":"Lobo","year":"2018","journal-title":"Ann. Transl. Med."},{"key":"pmeaadda8dbib15","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1007\/BF02425493","article-title":"Restoration of fluid balance after exercise-induced dehydration: effects of food and fluid intake","volume":"73","author":"Maughan","year":"1996","journal-title":"Eur. J. Appl. Physiol. Occup. Physiol."},{"key":"pmeaadda8dbib16","doi-asserted-by":"publisher","first-page":"7939","DOI":"10.1038\/s41598-017-08446-4","article-title":"Water ingestion decreases cardiac workload time-dependent in healthy adults with no effect of gender","volume":"7","author":"Monnard","year":"2017","journal-title":"Sci. Rep."},{"key":"pmeaadda8dbib17","doi-asserted-by":"publisher","first-page":"8719","DOI":"10.1038\/s41598-024-59139-8","article-title":"Non-invasive biomarkers for detecting progression toward hypovolemic cardiovascular instability in a lower body negative pressure model","volume":"14","author":"Murphy","year":"2024","journal-title":"Sci. Rep."},{"key":"pmeaadda8dbib18","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1213\/ANE.0000000000000241","article-title":"Recent advances in and limitations of cardiac output monitoring by means of electrical impedance tomography","volume":"119","author":"Pikkemaat","year":"2014","journal-title":"Anesth. Analg."},{"key":"pmeaadda8dbib19","doi-asserted-by":"publisher","first-page":"245","DOI":"10.3746\/pnf.2019.24.3.245","article-title":"Acute effects of passion fruit juice supplementation on cardiac autonomic function and blood glucose in healthy subjects","volume":"24","author":"Prasertsri","year":"2019","journal-title":"Prev. Nutrition Food Sci."},{"key":"pmeaadda8dbib20","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0285935","article-title":"Central venous pressure and dynamic indices to assess fluid appropriateness in critically ill patients: a pilot study","volume":"18","author":"Prezioso","year":"2023","journal-title":"PLoS One"},{"key":"pmeaadda8dbib21","doi-asserted-by":"publisher","first-page":"1176","DOI":"10.3390\/jcm8081176","article-title":"Electrical impedance tomography for cardio-pulmonary monitoring","volume":"8","author":"Putensen","year":"2019","journal-title":"J. Clin. Med."},{"key":"pmeaadda8dbib22","doi-asserted-by":"publisher","first-page":"537.e1","DOI":"10.1016\/j.jcrc.2012.10.008","article-title":"Prediction of fluid responsiveness in patients admitted to the medical intensive care unit","volume":"28","author":"Saugel","year":"2013","journal-title":"J. Crit. Care"},{"key":"pmeaadda8dbib23","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1093\/bja\/aev391","article-title":"Haemodynamic monitoring: the inseparable relation of accuracy and trending","volume":"115","author":"Saugel","year":"2015","journal-title":"Br. J. Anaesth."},{"key":"pmeaadda8dbib24","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/0735-6757(88)90151-9","article-title":"The use of transthoracic electrical bioimpedance in assessing thoracic fluid status in emergency department patients","volume":"6","author":"Saunders","year":"1988","journal-title":"Am. J. Emerg. Med."},{"key":"pmeaadda8dbib25","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1088\/0967-3334\/23\/1\/324","article-title":"Epoprostenol-induced pulmonary vasodilatation in patients with pulmonary hypertension measured by electrical impedance tomography","volume":"23","author":"Smit","year":"2002","journal-title":"Physiol. Meas."},{"key":"pmeaadda8dbib26","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1111\/j.1553-2712.2003.tb00054.x","article-title":"Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography","volume":"10","author":"Summers","year":"2003","journal-title":"Acad. Emergency Med."},{"key":"pmeaadda8dbib27","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1088\/0967-3334\/21\/2\/308","article-title":"Determination of stroke volume by means of electrical impedance tomography","volume":"21","author":"Vonk-Noordegraaf","year":"2000","journal-title":"Physiol. Meas."},{"key":"pmeaadda8dbib28","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s13102-016-0045-x","article-title":"Volume kinetic evaluation of fluid turnover after oral intake of tap water, lemonade and saline in volunteers","volume":"8","author":"Zdolsek","year":"2016","journal-title":"BMC Sports Sci. Med. Rehabil."}],"container-title":["Physiological Measurement"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T07:00:51Z","timestamp":1749193251000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1361-6579\/adda8d"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,30]]},"references-count":28,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2025,6,6]]},"published-print":{"date-parts":[[2025,5,30]]}},"URL":"https:\/\/doi.org\/10.1088\/1361-6579\/adda8d","relation":{},"ISSN":["0967-3334","1361-6579"],"issn-type":[{"type":"print","value":"0967-3334"},{"type":"electronic","value":"1361-6579"}],"subject":[],"published":{"date-parts":[[2025,5,30]]},"assertion":[{"value":"Approaching volume status via electrical impedance tomography\u2014an explorative study in healthy volunteers*","name":"article_title","label":"Article Title"},{"value":"Physiological Measurement","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-10-08","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-05-19","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-06-06","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}