{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T01:48:22Z","timestamp":1791942502694,"version":"4.3.4"},"reference-count":58,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2021,3,8]],"date-time":"2021-03-08T00:00:00Z","timestamp":1615161600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,3,8]],"date-time":"2021-03-08T00:00:00Z","timestamp":1615161600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100007188","name":"Uniformed Services University of the Health Sciences","doi-asserted-by":"crossref","award":["HU0001-17-2-0010"],"award-info":[{"award-number":["HU0001-17-2-0010"]}],"id":[{"id":"10.13039\/100007188","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Johns Hopkins University Applied Physics Laboratory","award":["Postdoctoral Fellowship"],"award-info":[{"award-number":["Postdoctoral Fellowship"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Neural Eng."],"published-print":{"date-parts":[[2021,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Full restoration of arm function using a prosthesis remains a grand challenge; however, advances in robotic hardware, surgical interventions, and machine learning are bringing seamless human-machine interfacing closer to reality.\n                    <jats:italic>Approach.<\/jats:italic>\n                    Through extensive data logging over 1 year, we monitored at-home use of the dexterous Modular Prosthetic Limb controlled through pattern recognition of electromyography (EMG) by an individual with a transhumeral amputation, targeted muscle reinnervation, and osseointegration (OI).\n                    <jats:italic>Main results.<\/jats:italic>\n                    Throughout the study, continuous prosthesis usage increased (1% per week,\n                    <jats:italic>p<\/jats:italic>\n                    &lt; 0.001) and functional metrics improved up to 26% on control assessments and 76% on perceived workload evaluations. We observed increases in torque loading on the OI implant (up to 12.5% every month,\n                    <jats:italic>p<\/jats:italic>\n                    &lt; 0.001) and prosthesis control performance (0.5% every month,\n                    <jats:italic>p<\/jats:italic>\n                    &lt; 0.005), indicating enhanced user integration, acceptance, and proficiency. More importantly, the EMG signal magnitude necessary for prosthesis control decreased, up to 34.7% (\n                    <jats:italic>p<\/jats:italic>\n                    &lt; 0.001), over time without degrading performance, demonstrating improved control efficiency with a machine learning-based myoelectric pattern recognition algorithm. The participant controlled the prosthesis up to one month without updating the pattern recognition algorithm. The participant customized prosthesis movements to perform specific tasks, such as individual finger control for piano playing and hand gestures for communication, which likely contributed to continued usage.\n                    <jats:italic>Significance.<\/jats:italic>\n                    This work demonstrates, in a single participant, the functional benefit of unconstrained use of a highly anthropomorphic prosthetic limb over an extended period. While hurdles remain for widespread use, including device reliability, results replication, and technical maturity beyond a prototype, this study offers insight as an example of the impact of advanced prosthesis technology for rehabilitation outside the laboratory.\n                  <\/jats:p>","DOI":"10.1088\/1741-2552\/abe20d","type":"journal-article","created":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T23:16:36Z","timestamp":1612221396000},"page":"026020","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":35,"title":["Extended home use of an advanced osseointegrated prosthetic arm improves function, performance, and control efficiency"],"prefix":"10.1088","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2985-6294","authenticated-orcid":false,"given":"Luke E","family":"Osborn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Courtney W","family":"Moran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew S","family":"Johannes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3586-2383","authenticated-orcid":false,"given":"Erin E","family":"Sutton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jared M","family":"Wormley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Dohopolski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle J","family":"Nordstrom","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josef A","family":"Butkus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1234-2601","authenticated-orcid":false,"given":"Albert","family":"Chi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2898-0082","authenticated-orcid":false,"given":"Paul F","family":"Pasquina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6163-0562","authenticated-orcid":false,"given":"Adam B","family":"Cohen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1500-2143","authenticated-orcid":false,"given":"Brock A","family":"Wester","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3425-7552","authenticated-orcid":false,"given":"Matthew S","family":"Fifer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3437-1884","authenticated-orcid":false,"given":"Robert S","family":"Armiger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2021,3,8]]},"reference":[{"key":"jneabe20dbib1","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1080\/03093640600994581","type":"journal-article","article-title":"Upper limb prosthesis use and abandonment: a survey of the last 25 years","volume":"31","author":"Biddiss","year":"2007","journal-title":"Prosthet. Orthot. Int."},{"key":"jneabe20dbib2","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1080\/17483100701714733","type":"journal-article","article-title":"Consumer design priorities for upper limb prosthetics","volume":"2","author":"Biddiss","year":"2007","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"jneabe20dbib3","doi-asserted-by":"publisher","first-page":"294","DOI":"10.3109\/17483107.2011.635405","type":"journal-article","article-title":"Prosthesis rejection in acquired major upper-limb amputees: a population-based survey","volume":"7","author":"\u00d8stlie","year":"2012","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"jneabe20dbib4","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1109\/TBME.2003.813539","type":"journal-article","article-title":"A robust, real-time control scheme for multifunction myoelectric control","volume":"50","author":"Englehart","year":"2003","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneabe20dbib5","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TBME.2019.2943309","type":"journal-article","article-title":"Stable responsive EMG sequence prediction and adaptive reinforcement with temporal convolutional networks","volume":"67","author":"Betthauser","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneabe20dbib6","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1038\/s41551-016-0025","type":"journal-article","article-title":"Man\/machine interface based on the discharge timings of spinal motor neurons after targeted muscle reinnervation","volume":"1","author":"Farina","year":"2017","journal-title":"Nat. Biomed. Eng."},{"key":"jneabe20dbib7","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1038\/s42256-019-0093-5","type":"journal-article","article-title":"Shared human\u2013robot proportional control of a dexterous myoelectric prosthesis","volume":"1","author":"Zhuang","year":"2019","journal-title":"Nat. Mach. Intell."},{"key":"jneabe20dbib8","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1001\/jama.2009.116","type":"journal-article","article-title":"Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms","volume":"301","author":"Kuiken","year":"2009","journal-title":"J. Am. Med. Assoc."},{"key":"jneabe20dbib9","doi-asserted-by":"publisher","first-page":"eaay2857","DOI":"10.1126\/scitranslmed.aay2857","type":"journal-article","article-title":"A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees","volume":"12","author":"Vu","year":"2020","journal-title":"Sci. Transl. Med."},{"key":"jneabe20dbib10","doi-asserted-by":"publisher","first-page":"9866","DOI":"10.1038\/s41598-018-26952-x","type":"journal-article","article-title":"Home use of a neural-connected sensory prosthesis provides the functional and psychosocial experience of having a hand again","volume":"8","author":"Graczyk","year":"2018","journal-title":"Sci. Rep."},{"key":"jneabe20dbib11","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/13\/1\/016001","type":"journal-article","article-title":"Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis","volume":"13","author":"Schiefer","year":"2016","journal-title":"J. Neural Eng."},{"key":"jneabe20dbib12","doi-asserted-by":"publisher","first-page":"222ra19","DOI":"10.1126\/scitranslmed.3006820","type":"journal-article","article-title":"Restoring natural sensory feedback in real-time bidirectional hand prostheses","volume":"6","author":"Raspopovic","year":"2014","journal-title":"Sci. Transl. Med."},{"key":"jneabe20dbib13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/BIOCAS.2017.8325200","type":"conference-proceedings","article-title":"Targeted transcutaneous electrical nerve stimulation for phantom limb sensory feedback","author":"Osborn","year":"2017"},{"key":"jneabe20dbib14","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/aab790","type":"journal-article","article-title":"Sensory adaptation to electrical stimulation of the somatosensory nerves","volume":"15","author":"Graczyk","year":"2018","journal-title":"J. Neural Eng."},{"key":"jneabe20dbib15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-019-55591-z","type":"journal-article","article-title":"Characterization of multi-channel intraneural stimulation in transradial amputees","volume":"9","author":"Strauss","year":"2019","journal-title":"Sci. Rep."},{"key":"jneabe20dbib16","doi-asserted-by":"publisher","first-page":"eaat3818","DOI":"10.1126\/scirobotics.aat3818","type":"journal-article","article-title":"Prosthesis with neuromorphic multilayered e-dermis perceives touch and pain","volume":"3","author":"Osborn","year":"2018","journal-title":"Sci. Rob."},{"key":"jneabe20dbib17","doi-asserted-by":"publisher","DOI":"10.7554\/eLife.09148","type":"journal-article","article-title":"Intraneural stimulation elicits discrimination of textural features by artificial fingertip in intact and amputee humans","volume":"5","author":"Oddo","year":"2016","journal-title":"Elife"},{"key":"jneabe20dbib18","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1038\/s41598-020-57454-4","type":"journal-article","article-title":"Morphological neural computation restores discrimination of naturalistic textures in trans-radial amputees","volume":"10","author":"Mazzoni","year":"2020","journal-title":"Sci. Rep."},{"key":"jneabe20dbib19","doi-asserted-by":"publisher","first-page":"eaau9924","DOI":"10.1126\/scirobotics.aau9924","type":"journal-article","article-title":"Restoring tactile sensations via neural interfaces for real-time force-and-slippage closed-loop control of bionic hands","volume":"4","author":"Zollo","year":"2019","journal-title":"Sci. Rob."},{"key":"jneabe20dbib20","doi-asserted-by":"publisher","first-page":"eaax2352","DOI":"10.1126\/scirobotics.aax2352","type":"journal-article","article-title":"Biomimetic sensory feedback through peripheral nerve stimulation improves dexterous use of a bionic hand","volume":"4","author":"George","year":"2019","journal-title":"Sci. Rob."},{"key":"jneabe20dbib21","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.neuron.2018.08.033","type":"journal-article","article-title":"Biomimetic intraneural sensory feedback enhances sensation naturalness, tactile sensitivity, and manual dexterity in a bidirectional prosthesis","volume":"100","author":"Valle","year":"2018","journal-title":"Neuron"},{"key":"jneabe20dbib22","doi-asserted-by":"publisher","first-page":"eaax2198","DOI":"10.1126\/scirobotics.aax2198","type":"journal-article","article-title":"A neuro-inspired artificial peripheral nervous system for scalable electronic skins","volume":"4","author":"Lee","year":"2019","journal-title":"Sci. Rob."},{"key":"jneabe20dbib23","doi-asserted-by":"publisher","first-page":"eaai9251","DOI":"10.1126\/scirobotics.aai9251","type":"journal-article","article-title":"Biomimetic temperature-sensing layer for artificial skins","volume":"2","author":"Di Giacomo","year":"2017","journal-title":"Sci. Rob."},{"key":"jneabe20dbib24","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1177\/0309364611409003","type":"journal-article","article-title":"Osseointegration amputation prostheses on the upper limbs: methods, prosthetics and rehabilitation","volume":"35","author":"J\u00f6nsson","year":"2011","journal-title":"Prosthet. Orthot. Int."},{"key":"jneabe20dbib25","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/978-1-84628-980-4_10","type":"book","author":"Hagberg","year":"2008"},{"key":"jneabe20dbib26","doi-asserted-by":"publisher","first-page":"257re6","DOI":"10.1126\/scitranslmed.3008933","type":"journal-article","article-title":"An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs","volume":"6","author":"Ortiz-Catalan","year":"2014","journal-title":"Sci. Transl. Med."},{"key":"jneabe20dbib27","doi-asserted-by":"publisher","first-page":"2333","DOI":"10.1109\/TNSRE.2018.2880948","type":"journal-article","article-title":"Restoring natural forearm rotation in transradial osseointegrated amputees","volume":"26","author":"Boni","year":"2018","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"jneabe20dbib28","doi-asserted-by":"publisher","first-page":"1732","DOI":"10.1056\/NEJMoa1917537","type":"journal-article","article-title":"Self-contained neuromusculoskeletal arm prostheses","volume":"382","author":"Ortiz-Catalan","year":"2020","journal-title":"New Engl. J. Med."},{"key":"jneabe20dbib29","doi-asserted-by":"publisher","first-page":"1369","DOI":"10.1007\/s10439-019-02244-x","type":"journal-article","article-title":"Loads on transhumeral amputees using osseointegrated prostheses","volume":"47","author":"Stenlund","year":"2019","journal-title":"Ann. Biomed. Eng."},{"key":"jneabe20dbib30","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0189418","type":"journal-article","article-title":"Transhumeral loading during advanced upper extremity activities of daily living","volume":"12","author":"Drew","year":"2017","journal-title":"PLoS One"},{"key":"jneabe20dbib31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-018-29503-6","type":"journal-article","article-title":"Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance","volume":"8","author":"Chadwell","year":"2018","journal-title":"Sci. Rep."},{"key":"jneabe20dbib32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fnins.2019.00853","type":"journal-article","article-title":"Learning of artificial sensation through long-term home use of a sensory-enabled prosthesis","volume":"13","author":"Cuberovic","year":"2019","journal-title":"Frontiers Neurosci."},{"key":"jneabe20dbib33","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1682\/JRRD.2013.08.0180","type":"journal-article","article-title":"Self-reported and performance-based outcomes using DEKA Arm","volume":"51","author":"Resnik","year":"2014","journal-title":"J. Rehabil. Res. Dev."},{"key":"jneabe20dbib34","doi-asserted-by":"publisher","first-page":"816","DOI":"10.1080\/17483107.2016.1269212","type":"journal-article","article-title":"Attrition and retention in upper limb prosthetics research: experience of the VA home study of the DEKA arm","volume":"12","author":"Resnik","year":"2017","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"jneabe20dbib35","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1177\/0309364617728117","type":"journal-article","article-title":"The DEKA hand: a multifunction prosthetic terminal device\u2014patterns of grip usage at home","volume":"42","author":"Resnik","year":"2018","journal-title":"Prosthet. Orthot. Int."},{"key":"jneabe20dbib36","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0191326","type":"journal-article","article-title":"How do the outcomes of the DEKA Arm compare to conventional prostheses?","volume":"13","author":"Resnik","year":"2018","journal-title":"PLoS One"},{"key":"jneabe20dbib37","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1177\/0309364616631348","type":"journal-article","article-title":"Movement quality of conventional prostheses and the DEKA Arm during everyday tasks","volume":"41","author":"Cowley","year":"2017","journal-title":"Prosthet. Orthot. Int."},{"key":"jneabe20dbib38","first-page":"207","type":"journal-article","article-title":"An overview of the development process for the modular prosthetic limb","volume":"30","author":"Johannes","year":"2011","journal-title":"JHU APL Tech. Digest"},{"key":"jneabe20dbib39","first-page":"393","author":"Johannes","year":"2019","type":"book"},{"key":"jneabe20dbib40","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/13\/2\/026017","type":"journal-article","article-title":"Individual finger control of a modular prosthetic limb using high-density electrocorticography in a human subject","volume":"13","author":"Hotson","year":"2016","journal-title":"J. Neural Eng."},{"key":"jneabe20dbib41","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1109\/TNSRE.2013.2286955","type":"journal-article","article-title":"Simultaneous neural control of simple reaching and grasping with the modular prosthetic limb using intracranial EEG","volume":"22","author":"Fifer","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"jneabe20dbib42","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/S0140-6736(12)61816-9","type":"journal-article","article-title":"High-performance neuroprosthetic control by an individual with tetraplegia","volume":"381","author":"Collinger","year":"2012","journal-title":"Lancet"},{"key":"jneabe20dbib43","doi-asserted-by":"publisher","first-page":"784","DOI":"10.1109\/TNSRE.2013.2294685","type":"journal-article","article-title":"Demonstration of a semi-autonomous hybrid brain-machine interface using human intracranial EEG, eye tracking, and computer vision to control a robotic upper limb prosthetic","volume":"22","author":"McMullen","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"jneabe20dbib44","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fneur.2018.00153","type":"journal-article","article-title":"Initial clinical evalu-ation of the modular prosthetic limb","volume":"9","author":"Perry","year":"2018","journal-title":"Frontiers Neurol."},{"key":"jneabe20dbib45","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/JPO.0000000000000254","type":"journal-article","article-title":"Modular prosthetic limb control by an individual with congenital upper-limb amputation: a case report","volume":"31","author":"Moran","year":"2019","journal-title":"J. Prosthet. Orthot."},{"key":"jneabe20dbib46","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0186132","type":"journal-article","article-title":"Comparison of six electromyography acquisition setups on hand movement classification tasks","volume":"12","author":"Pizzolato","year":"2017","journal-title":"PLoS One"},{"key":"jneabe20dbib47","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1682\/JRRD.2010.08.0149","type":"journal-article","article-title":"Target achievement control test: evaluating real-time myoelectric pattern-recognition control of multifun-ctional upper-limb prostheses","volume":"48","author":"Simon","year":"2011","journal-title":"J. Rehabil. Res. Dev."},{"key":"jneabe20dbib48","first-page":"311","type":"journal-article","article-title":"An objective and standardized test of hand function","volume":"50","author":"Jebsen","year":"1969","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"jneabe20dbib49","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1080\/16501970410024280","type":"journal-article","article-title":"Assessmet of capacity for myoelectric control: a new Rasch-built measure of prosthetic hand control","volume":"37","author":"Hermansson","year":"2005","journal-title":"J. Rehabil. Med."},{"key":"jneabe20dbib50","doi-asserted-by":"publisher","first-page":"386","DOI":"10.5014\/ajot.39.6.386","type":"journal-article","article-title":"Adult norms for the Box and Block Test of manual dexterity","volume":"39","author":"Mathiowetz","year":"1985","journal-title":"Am. J. Occup. Ther. Off. Publ. Am. Occup. Ther. Assoc."},{"key":"jneabe20dbib51","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/s0166-4115(08)62386-9","type":"journal-article","article-title":"Development of NASA-TLX (Task Load Index): results of empirical and theoretical research","volume":"52","author":"Hart","year":"1988","journal-title":"Adv. Psychol."},{"key":"jneabe20dbib52","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/1471-2474-7-44","type":"journal-article","article-title":"The shortened disabilities of the arm, shoulder and hand questionnaire (Quick DASH): validity and reliability based on responses within the full-length DASH","volume":"7","author":"Gummesson","year":"2006","journal-title":"BMC Musculoskelet. Disord."},{"key":"jneabe20dbib53","first-page":"1","type":"conference-proceedings","article-title":"Long-term functional improvement with dexterous prosthetic limb","author":"Sutton","year":"2020"},{"key":"jneabe20dbib54","author":"Templin","year":"2018","type":"web-resource"},{"key":"jneabe20dbib55","first-page":"366","type":"journal-article","article-title":"Revolutionizing prosthetics\u2014phase 3","volume":"31","author":"Ravitz","year":"2013","journal-title":"Johns Hopkins APL Tech. Digest"},{"key":"jneabe20dbib56","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1007\/s00221-008-1355-3","type":"journal-article","article-title":"The statistics of natural hand movements","volume":"188","author":"Ingram","year":"2008","journal-title":"Exp. Brain Res."},{"key":"jneabe20dbib57","doi-asserted-by":"publisher","DOI":"10.1109\/JTEHM.2018.2883943","type":"journal-article","article-title":"EMG pattern recognition control of the DEKA Arm: impact on user ratings of satisfaction and usability","volume":"7","author":"Resnik","year":"2019","journal-title":"IEEE J. Transl. Eng. Heal. Med."},{"key":"jneabe20dbib58","doi-asserted-by":"publisher","first-page":"121","DOI":"10.3389\/fnhum.2011.00121","type":"journal-article","article-title":"\u2018Pulling telescoped phantoms out of the stump\u2019: manipulating the perceived position of phantom limbs using a full-body illusion","volume":"5","author":"Schmalzl","year":"2011","journal-title":"Frontiers Hum. Neurosci."}],"container-title":["Journal of Neural Engineering"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T15:15:42Z","timestamp":1765034142000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/abe20d"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,8]]},"references-count":58,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2021,3,8]]},"published-print":{"date-parts":[[2021,4,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1741-2552\/abe20d","relation":{},"ISSN":["1741-2560","1741-2552"],"issn-type":[{"value":"1741-2560","type":"print"},{"value":"1741-2552","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,8]]},"assertion":[{"value":"Extended home use of an advanced osseointegrated prosthetic arm improves function, performance, and control efficiency","name":"article_title","label":"Article Title"},{"value":"Journal of Neural Engineering","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-10-30","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-02-01","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-03-08","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}