{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T12:31:49Z","timestamp":1788957109767,"version":"build-2803163510"},"reference-count":32,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2022,3,8]],"date-time":"2022-03-08T00:00:00Z","timestamp":1646697600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2022,3,8]],"date-time":"2022-03-08T00:00:00Z","timestamp":1646697600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100010663","name":"H2020 European Research Council","doi-asserted-by":"crossref","award":["855109"],"award-info":[{"award-number":["855109"]}],"id":[{"id":"10.13039\/100010663","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100010664","name":"H2020 Future and Emerging Technologies","doi-asserted-by":"crossref","award":["101017716"],"award-info":[{"award-number":["101017716"]}],"id":[{"id":"10.13039\/100010664","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Neural Eng."],"published-print":{"date-parts":[[2022,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . Metal implants impact the dosimetry assessment in electrical stimulation techniques. Therefore, they need to be included in numerical models. While currents in the body are ionic, metals only allow electron transport. In fact, charge transfer between tissues and metals requires electric fields to drive electrochemical reactions at the interface. Thus, metal implants may act as insulators or as conductors depending on the scenario. The aim of this paper is to provide a theoretical argument that guides the choice of the correct representation of metal implants in electrical models while considering the electrochemical nature of the problem\n                    <jats:italic>Approach.<\/jats:italic>\n                    We built a simple model of a metal implant exposed to a homogeneous electric field of various magnitudes. The same geometry was solved using two different models: a purely electric one (with different conductivities for the implant), and an electrochemical one. As an example of application, we also modeled a transcranial electrical stimulation (tES) treatment in a realistic head model with a skull plate using a high and low conductivity value for the plate.\n                    <jats:italic>Main results<\/jats:italic>\n                    . Metal implants generally act as electric insulators when exposed to electric fields up to around 100 V m\n                    <jats:sup>\u22121<\/jats:sup>\n                    and they only resemble a perfect conductor for fields in the order of 1000 V m\n                    <jats:sup>\u22121<\/jats:sup>\n                    and above. The results are independent of the implant\u2019s metal, but they depend on its geometry. tES modeling with implants incorrectly treated as conductors can lead to errors of 50% or more in the estimation of the induced fields\n                    <jats:italic>Significance.<\/jats:italic>\n                    Metal implants can be accurately represented by a simple electrical model of constant conductivity, but an incorrect model choice can lead to large errors in the dosimetry assessment. Our results can be used to guide the selection of the most appropriate model in each scenario.\n                  <\/jats:p>","DOI":"10.1088\/1741-2552\/ac55ae","type":"journal-article","created":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T17:15:12Z","timestamp":1645031712000},"page":"026003","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":17,"title":["Modeling implanted metals in electrical stimulation applications"],"prefix":"10.1088","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0941-6796","authenticated-orcid":true,"given":"Borja","family":"Mercadal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1235-6533","authenticated-orcid":true,"given":"Ricardo","family":"Salvador","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3660-8283","authenticated-orcid":false,"given":"Maria Chiara","family":"Biagi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1678-0297","authenticated-orcid":false,"given":"Fabrice","family":"Bartolomei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2428-9665","authenticated-orcid":false,"given":"Fabrice","family":"Wendling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3084-0177","authenticated-orcid":false,"given":"Giulio","family":"Ruffini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2022,3,8]]},"reference":[{"key":"jneac55aebib1","doi-asserted-by":"publisher","first-page":"1774","DOI":"10.1016\/j.clinph.2017.06.001","type":"journal-article","article-title":"Low intensity transcranial electric stimulation: safety, ethical, legal regulatory and application guidelines","volume":"128","author":"Argyraki","year":"2017","journal-title":"Clin. Neurophysiol."},{"key":"jneac55aebib2","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1016\/j.neuroimage.2010.04.252","type":"journal-article","article-title":"Transcranial direct current stimulation in patients with skull defects and skull plates: high-resolution computational FEM study of factors altering cortical current flow","volume":"52","author":"Datta","year":"2010","journal-title":"Neuroimage"},{"key":"jneac55aebib3","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1016\/j.neuroimage.2013.12.002","type":"journal-article","article-title":"Optimization of multifocal transcranial current stimulation for weighted cortical pattern targeting from realistic modeling of electric fields","volume":"89","author":"Ruffini","year":"2014","journal-title":"Neuroimage"},{"key":"jneac55aebib4","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.brs.2011.03.002","type":"journal-article","article-title":"Clinical research with tDCS: challenges and future directions","volume":"5","author":"Brunoni","year":"2012","journal-title":"Brain Stimul."},{"key":"jneac55aebib5","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1111\/j.1528-1167.2010.02536.x","type":"journal-article","article-title":"Electrical stimulation of the anterior nucleus of thalamus for treatment of refractory epilepsy","volume":"51","author":"Fisher","year":"2010","journal-title":"Epilepsia"},{"key":"jneac55aebib6","doi-asserted-by":"publisher","first-page":"e25","DOI":"10.1111\/epi.14677","type":"journal-article","article-title":"The effect of medial pulvinar stimulation on temporal lobe seizures","volume":"60","author":"Filipescu","year":"2019","journal-title":"Epilepsia"},{"key":"jneac55aebib7","doi-asserted-by":"publisher","first-page":"2536","DOI":"10.1016\/j.clinph.2007.08.003","type":"journal-article","article-title":"Minimal heating of titanium skull plates during 1 Hz repetitive transcranial magnetic stimulation","volume":"118","author":"Rotenberg","year":"2007","journal-title":"Clin. Neurophysiol."},{"key":"jneac55aebib8","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.neuroimage.2012.12.034","type":"journal-article","article-title":"The electric field in the cortex during transcranial current stimulation","volume":"70","author":"Miranda","year":"2013","journal-title":"Neuroimage"},{"key":"jneac55aebib9","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1109\/TBME.2003.816079","type":"journal-article","article-title":"The electric field induced in the brain by magnetic stimulation: a 3D finite-element analysis of the effect of tissue heterogeneity and anisotropy","volume":"50","author":"Miranda","year":"2003","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneac55aebib10","doi-asserted-by":"publisher","first-page":"0460d4","DOI":"10.1088\/1741-2552\/ac17d7","type":"journal-article","article-title":"Boundary element fast multipole method for modeling electrical brain stimulation with voltage and current electrodes","volume":"18","author":"Makarov","year":"2021","journal-title":"J. Neural Eng."},{"key":"jneac55aebib11","doi-asserted-by":"publisher","first-page":"7813","DOI":"10.1088\/0031-9155\/57\/23\/7813","type":"journal-article","article-title":"Combined use of transcranial magnetic stimulation and metal electrode implants: a theoretical assessment of safety considerations","volume":"57","author":"Golestanirad","year":"2012","journal-title":"Phys. Med. Biol."},{"key":"jneac55aebib12","author":"Grimnes","year":"2008","type":"book"},{"key":"jneac55aebib13","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1016\/j.brs.2016.06.004","type":"journal-article","article-title":"Safety of transcranial direct current stimulation: evidence based update 2016","volume":"9","author":"Bikson","year":"2016","journal-title":"Brain Stimul."},{"key":"jneac55aebib14","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1109\/TBME.2012.2189885","type":"journal-article","article-title":"Modeling the field distribution in deep brain stimulation: the influence of anisotropy of brain tissue","volume":"59","author":"Schmidt","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneac55aebib15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fncom.2018.00040","type":"journal-article","article-title":"Modeling current sources for neural stimulation in COMSOL","volume":"12","author":"Pelot","year":"2018","journal-title":"Front. Comput. Neurosci."},{"key":"jneac55aebib16","doi-asserted-by":"publisher","first-page":"6677","DOI":"10.3390\/app11156677","type":"journal-article","article-title":"Numerical simulation of electric field distribution around an instrumented total hip stem","volume":"11","author":"Zimmermann","year":"2021","journal-title":"Appl. Sci."},{"key":"jneac55aebib17","author":"Rieger","year":"1994","type":"book"},{"key":"jneac55aebib18","doi-asserted-by":"publisher","first-page":"180","DOI":"10.3390\/ma7010180","type":"journal-article","article-title":"Improvement to the corrosion resistance of Ti-based implants using hydrothermally synthesized nanostructured anatase coatings","volume":"7","author":"Lorenzetti","year":"2014","journal-title":"Materials"},{"key":"jneac55aebib19","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1002\/maco.200603979","type":"journal-article","article-title":"Electrochemical impedance spectroscopic studies of titanium and its alloys in saline medium","volume":"58","author":"Tamilselvi","year":"2007","journal-title":"Mater. Corros."},{"key":"jneac55aebib20","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.msea.2004.03.069","type":"journal-article","article-title":"Electrochemical corrosion properties of Ti-6Al-4V implant alloy in the biological environment","volume":"380","author":"Hsu","year":"2004","journal-title":"Mater. Sci. Eng. A"},{"key":"jneac55aebib21","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1007\/s10548-019-00710-2","type":"journal-article","article-title":"Variation in reported human head tissue electrical conductivity values","volume":"32","author":"McCann","year":"2019","journal-title":"Brain. Topogr."},{"key":"jneac55aebib22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1117\/1.NPh.7.1.015008","type":"journal-article","article-title":"Improving model-based functional near-infrared spectroscopy analysis using mesh-based anatomical and light-transport models","volume":"7","author":"Tran","year":"2020","journal-title":"Neurophotonics"},{"key":"jneac55aebib23","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/978-3-030-21293-3_1","type":"book","author":"Saturnino","year":"2019"},{"key":"jneac55aebib24","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/ab41ba","type":"journal-article","article-title":"Electric field simulations for transcranial brain stimulation using FEM: an efficient implementation and error analysis","volume":"16","author":"Saturnino","year":"2019","journal-title":"J. Neural Eng."},{"key":"jneac55aebib25","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/j.neuron.2007.07.027","type":"journal-article","article-title":"In vivo measurement of cortical impedance spectrum in monkeys: implications for signal propagation","volume":"55","author":"Logothetis","year":"2007","journal-title":"Neuron"},{"key":"jneac55aebib26","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.1109\/TBME.2003.816072","type":"journal-article","article-title":"In vivo measurement of the brain and skull resistivities using an eit-based method and the combined analysis of sef\/sep data","volume":"50","author":"Gonalves","year":"2003","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneac55aebib27","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1109\/10.554770","type":"journal-article","article-title":"The electrical conductivity of human cerebrospinal fluid at body temperature","volume":"44","author":"Baumann","year":"1997","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneac55aebib28","first-page":"1","author":"Compton","year":"2011","type":"book"},{"key":"jneac55aebib29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fnhum.2018.00268","type":"journal-article","article-title":"Modeling transcranial direct-current stimulation-induced electric fields in children and adults","volume":"12","author":"Ciechanski","year":"2018","journal-title":"Front. Hum. Neurosci."},{"key":"jneac55aebib30","doi-asserted-by":"publisher","DOI":"10.1063\/1.4973604","type":"journal-article","article-title":"Transcranial magnetic stimulation-coil design with improved focality","volume":"7","author":"Rastogi","year":"2017","journal-title":"AIP Adv."},{"key":"jneac55aebib31","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1016\/j.brs.2021.07.012","type":"journal-article","article-title":"Adaptive current-flow models of ECT: explaining individual static impedance, dynamic impedance, and brain current density","volume":"14","author":"Unal","year":"2021","journal-title":"Brain Stimul."},{"key":"jneac55aebib32","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1109\/TBME.2007.903522","type":"journal-article","article-title":"A new 3D finite-element model based on thin-film approximation for microelectrode array recording of extracellular action potential","volume":"55","author":"Moulin","year":"2008","journal-title":"IEEE Trans. Biomed. Eng."}],"container-title":["Journal of Neural Engineering"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,22]],"date-time":"2025-11-22T15:08:35Z","timestamp":1763824115000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac55ae"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,8]]},"references-count":32,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2022,3,8]]},"published-print":{"date-parts":[[2022,4,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1741-2552\/ac55ae","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2021.12.04.471211","asserted-by":"object"}]},"ISSN":["1741-2560","1741-2552"],"issn-type":[{"value":"1741-2560","type":"print"},{"value":"1741-2552","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,8]]},"assertion":[{"value":"Modeling implanted metals in electrical stimulation applications","name":"article_title","label":"Article Title"},{"value":"Journal of Neural Engineering","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2021-12-15","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-02-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-03-08","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}