{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T23:32:19Z","timestamp":1790811139309,"version":"4.1.0"},"reference-count":41,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2022,4,8]],"date-time":"2022-04-08T00:00:00Z","timestamp":1649376000000},"content-version":"vor","delay-in-days":7,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2022,4,8]],"date-time":"2022-04-08T00:00:00Z","timestamp":1649376000000},"content-version":"tdm","delay-in-days":7,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000098","name":"NIH Clinical Center","doi-asserted-by":"crossref","award":["R01NS104344"],"award-info":[{"award-number":["R01NS104344"]}],"id":[{"id":"10.13039\/100000098","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Neural Eng."],"published-print":{"date-parts":[[2022,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective<\/jats:italic>\n                    . Trauma induced by the insertion of microelectrodes into cortical neural tissue is a significant problem. Further, micromotion and mechanical mismatch between microelectrode probes and neural tissue is implicated in an adverse foreign body response (FBR). Hence, intracortical ultra-microelectrode probes have been proposed as alternatives that minimize this FBR. However, significant challenges in implanting these flexible probes remain. We investigated the insertion mechanics of amorphous silicon carbide (a-SiC) probes with a view to defining probe geometries that can be inserted into cortex without buckling.\n                    <jats:italic>Approach<\/jats:italic>\n                    . We determined the critical buckling force of a-SiC probes as a function of probe geometry and then characterized the buckling behavior of these probes by measuring force\u2013displacement responses during insertion into agarose gel and rat cortex.\n                    <jats:italic>Main results.<\/jats:italic>\n                    Insertion forces for a range of probe geometries were determined and compared with critical buckling forces to establish geometries that should avoid buckling during implantation into brain. The studies show that slower insertion speeds reduce the maximum insertion force for single-shank probes but increase cortical dimpling during insertion of multi-shank probes.\n                    <jats:italic>Significance.<\/jats:italic>\n                    Our results provide a guide for selecting probe geometries and insertion speeds that allow unaided implantation of probes into rat cortex. The design approach is applicable to other animal models where insertion of intracortical probes to a depth of 2 mm is required.\n                  <\/jats:p>","DOI":"10.1088\/1741-2552\/ac5bf4","type":"journal-article","created":{"date-parts":[[2022,3,9]],"date-time":"2022-03-09T17:17:41Z","timestamp":1646846261000},"page":"026033","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":26,"title":["Insertion mechanics of amorphous SiC ultra-micro scale neural probes"],"prefix":"10.1088","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5717-5376","authenticated-orcid":true,"given":"Negar","family":"Geramifard","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7475-8178","authenticated-orcid":true,"given":"Behnoush","family":"Dousti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6596-4869","authenticated-orcid":true,"given":"Christopher","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1514-3357","authenticated-orcid":true,"given":"Justin","family":"Abbott","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6316-3032","authenticated-orcid":true,"given":"Stuart F","family":"Cogan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4575-4733","authenticated-orcid":true,"given":"Victor D","family":"Varner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2022,4,8]]},"reference":[{"key":"jneac5bf4bib1","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/13\/6\/061003","type":"journal-article","article-title":"Clinical applications of penetrating neural interfaces and Utah electrode array technologies","volume":"13","author":"Normann","year":"2016","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib2","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1146\/annurev-bioeng-071910-124640","type":"journal-article","article-title":"Sensors and decoding for intracortical brain computer interfaces","volume":"15","author":"Homer","year":"2013","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"jneac5bf4bib3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/s19051069","type":"journal-article","article-title":"Recent progress on non\u2010conventional microfabricated probes for the chronic recording of cortical neural activity","volume":"19","author":"Kim","year":"2019","journal-title":"Sensors"},{"key":"jneac5bf4bib4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1126\/sciadv.1601966","type":"journal-article","article-title":"Ultraflexible nanoelectronic probes form reliable, glial scar\u2013free neural integration","volume":"3","author":"Luan","year":"2017","journal-title":"Sci. Adv."},{"key":"jneac5bf4bib5","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1038\/nmat3468","type":"journal-article","article-title":"Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces","volume":"11","author":"Yoshida Kozai","year":"2012","journal-title":"Nat. Mater."},{"key":"jneac5bf4bib6","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/6\/5\/056003","type":"journal-article","article-title":"Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration","volume":"6","author":"McConnell","year":"2009","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib7","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/10\/4\/046016","type":"journal-article","article-title":"A carbon-fiber electrode array for long-term neural recording","volume":"10","author":"Guitchounts","year":"2013","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib8","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/13\/3\/036012","type":"journal-article","article-title":"Correlations between histology and neuronal activity recorded by microelectrodes implanted chronically in the cerebral cortex","volume":"13","author":"McCreery","year":"2016","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib9","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/10\/6\/066014","type":"journal-article","article-title":"Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates","volume":"10","author":"Barrese","year":"2013","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib10","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/13\/6\/066002","type":"journal-article","article-title":"Chronic in vivo stability assessment of carbon fiber microelectrode arrays","volume":"13","author":"Patel","year":"2016","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib11","doi-asserted-by":"publisher","first-page":"4606","DOI":"10.1109\/IEMBS.2006.260528","type":"conference-proceedings","article-title":"Fabrication of polymer neural probes with sub-cellular features for reduced tissue encapsulation","author":"Seymour","year":"2006"},{"key":"jneac5bf4bib12","doi-asserted-by":"publisher","first-page":"443","DOI":"10.3390\/mi9090443","type":"journal-article","article-title":"A meta-analysis of intracortical device stiffness and its correlation with histological outcomes","volume":"9","author":"Stiller","year":"2018","journal-title":"Micromachines"},{"key":"jneac5bf4bib13","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/ab2b2e","type":"journal-article","article-title":"A microfabricated, 3D-sharpened silicon shuttle for insertion of flexible electrode arrays through dura mater into brain","volume":"16","author":"Joo","year":"2019","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib14","doi-asserted-by":"publisher","DOI":"10.1115\/1.4047858","type":"journal-article","article-title":"Mechanics strategies for implantation of flexible neural probes","volume":"88","author":"Zhang","year":"2021","journal-title":"J. Appl. Mech."},{"key":"jneac5bf4bib15","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/abacd7","type":"journal-article","article-title":"Gels, jets, mosquitoes, and magnets: a review of implantation strategies for soft neural probes","volume":"17","author":"Apollo","year":"2020","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib16","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1088\/0960-1317\/14\/1\/305","type":"journal-article","article-title":"Polyimide-based intracortical neural implant with improved structural stiffness","volume":"14","author":"Lee","year":"2004","journal-title":"J. Micromech. Microeng."},{"key":"jneac5bf4bib17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-017-18522-4","type":"journal-article","article-title":"A mosquito inspired strategy to implant microprobes into the brain","volume":"8","author":"Shoffstall","year":"2018","journal-title":"Sci. Rep."},{"key":"jneac5bf4bib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2020.112608","type":"journal-article","article-title":"Intraneural ultramicroelectrode arrays for function-specific interfacing to the vagus nerve","volume":"170","author":"Ghazavi","year":"2020","journal-title":"Biosens. Bioelectron."},{"key":"jneac5bf4bib19","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/aa8f8b","type":"journal-article","article-title":"Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording","volume":"15","author":"Deku","year":"2018","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib20","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/aa7698","type":"journal-article","article-title":"A silicon carbide array for electrocorticography and peripheral nerve recording","volume":"14","author":"Diaz-Botia","year":"2017","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib21","doi-asserted-by":"publisher","first-page":"480","DOI":"10.3390\/mi9100480","type":"journal-article","article-title":"Amorphous silicon carbide platform for next generation penetrating neural interface designs","volume":"9","author":"Deku","year":"2018","journal-title":"Micromachines"},{"key":"jneac5bf4bib22","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/10\/2\/026007","type":"journal-article","article-title":"Chronic intracortical microelectrode arrays induce non-uniform, depth-related tissue responses","volume":"10","author":"Woolley","year":"2013","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib23","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/12\/3\/036002","type":"journal-article","article-title":"Compliant intracortical implants reduce strains and strain rates in brain tissue in vivo","volume":"12","author":"Sridharan","year":"2015","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib24","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.jneumeth.2014.08.012","type":"journal-article","article-title":"In vivo evaluation of needle force and friction stress during insertion at varying insertion speed into the brain","volume":"237","author":"Casanova","year":"2014","journal-title":"J. Neurosci. Methods"},{"key":"jneac5bf4bib25","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1021\/bm005583j","type":"journal-article","article-title":"New insight into agarose gel mechanical properties","volume":"1","author":"Normand","year":"2000","journal-title":"Biomacromolecules"},{"key":"jneac5bf4bib26","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/9\/1\/016005","type":"journal-article","article-title":"A response surface model predicting the in vivo insertion behavior of micromachined neural implants","volume":"9","author":"Andrei","year":"2012","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib27","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/10\/6\/066001","type":"journal-article","article-title":"Long-term changes in the material properties of brain tissue at the implant-tissue interface","volume":"10","author":"Sridharan","year":"2013","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib28","doi-asserted-by":"publisher","first-page":"2784","DOI":"10.1109\/EMBC.2016.7591308","type":"conference-proceedings","article-title":"Effects of geometry and material on the insertion of very small neural electrode","volume":"vol 2016","author":"Marshall","year":"2016"},{"key":"jneac5bf4bib29","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1088\/1741-2560\/2\/4\/006","type":"journal-article","article-title":"A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex","volume":"2","author":"Subbaroyan","year":"2005","journal-title":"J. Neural Eng."},{"key":"jneac5bf4bib30","author":"Timoshenko","year":"1961","type":"book"},{"key":"jneac5bf4bib31","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1557\/JMR.1994.0096","type":"journal-article","article-title":"Hardness and Young\u2018s modulus of amorphous a-SiC thin films determined by nanoindentation and bulge tests","volume":"9","author":"El Khakani","year":"1994","journal-title":"J. Mater. Res."},{"key":"jneac5bf4bib32","first-page":"3","author":"Xue","year":"2011","type":"book"},{"key":"jneac5bf4bib33","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.jmbbm.2019.05.001","type":"journal-article","article-title":"Reliable preparation of agarose phantoms for use in quantitative magnetic resonance elastography","volume":"97","author":"McIlvain","year":"2019","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"jneac5bf4bib34","doi-asserted-by":"publisher","first-page":"4711","DOI":"10.1109\/IEMBS.2007.4353391","type":"conference-proceedings","article-title":"Comparative study on the insertion behavior of cerebral microprobes","author":"Hosseini","year":"2007"},{"key":"jneac5bf4bib35","doi-asserted-by":"publisher","DOI":"10.1101\/2020.09.21.306498","type":"preprint","article-title":"Ultra-sensitive measurement of brain penetration with microscale probes for brain machine interface considerations","author":"Obaid","year":"2020"},{"key":"jneac5bf4bib36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jneumeth.2005.08.015","type":"journal-article","article-title":"Response of brain tissue to chronically implanted neural electrodes","volume":"148","author":"Polikov","year":"2005","journal-title":"J. Neurosci. Methods"},{"key":"jneac5bf4bib37","doi-asserted-by":"publisher","first-page":"9255","DOI":"10.1016\/j.biomaterials.2014.07.039","type":"journal-article","article-title":"Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes","volume":"35","author":"Kozai","year":"2014","journal-title":"Biomaterials"},{"key":"jneac5bf4bib38","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1109\/TBME.2008.2003261","type":"journal-article","article-title":"In vivo penetration mechanics and mechanical properties of mouse brain tissue at micrometer scales","volume":"56","author":"Sharp","year":"2009","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneac5bf4bib39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10856-015-5401-y","type":"journal-article","article-title":"Experimental study on the mechanical interaction between silicon neural microprobes and rat dura mater during insertion","volume":"26","author":"Fekete","year":"2015","journal-title":"J. Mater. Sci., Mater. Med."},{"key":"jneac5bf4bib40","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1109\/JMEMS.2014.2375326","type":"journal-article","article-title":"Silk-backed structural optimization of high-density flexible intracortical neural probes","volume":"24","author":"Wu","year":"2015","journal-title":"J. Microelectromech. Syst."},{"key":"jneac5bf4bib41","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1002\/jbm.b.31883","type":"journal-article","article-title":"Comparative study of the viscoelastic mechanical behavior of agarose and poly(ethylene glycol) hydrogels","volume":"99","author":"Roberts","year":"2011","journal-title":"J. Biomed. Mater. Res. B"}],"container-title":["Journal of Neural Engineering"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,22]],"date-time":"2025-11-22T15:02:44Z","timestamp":1763823764000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac5bf4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,1]]},"references-count":41,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2022,4,8]]},"published-print":{"date-parts":[[2022,4,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1741-2552\/ac5bf4","relation":{"has-review":[{"id-type":"doi","id":"10.1088\/1741-2552\/AC5BF4\/v2\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/1741-2552\/AC5BF4\/v2\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/1741-2552\/AC5BF4\/v1\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/1741-2552\/AC5BF4\/v1\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/1741-2552\/AC5BF4\/v1\/review2","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/1741-2552\/AC5BF4\/v2\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/1741-2552\/AC5BF4\/v2\/review2","asserted-by":"object"}]},"ISSN":["1741-2560","1741-2552"],"issn-type":[{"value":"1741-2560","type":"print"},{"value":"1741-2552","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,1]]},"assertion":[{"value":"Insertion mechanics of amorphous SiC ultra-micro scale neural probes","name":"article_title","label":"Article Title"},{"value":"Journal of Neural Engineering","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2021-10-14","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-03-09","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-04-08","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}