{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,22]],"date-time":"2025-11-22T15:01:33Z","timestamp":1763823693915,"version":"3.45.0"},"reference-count":52,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2022,5,30]],"date-time":"2022-05-30T00:00:00Z","timestamp":1653868800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2022,5,30]],"date-time":"2022-05-30T00:00:00Z","timestamp":1653868800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Johns Hopkins University Applied Physics Laboratory"},{"DOI":"10.13039\/100007188","name":"Uniformed Services University of the Health Sciences","doi-asserted-by":"crossref","award":["HU00011520028"],"award-info":[{"award-number":["HU00011520028"]}],"id":[{"id":"10.13039\/100007188","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Neural Eng."],"published-print":{"date-parts":[[2022,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Validating the ability for advanced prostheses to improve function beyond the laboratory remains a critical step in enabling long-term benefits for prosthetic limb users.\n                    <jats:italic>Approach.<\/jats:italic>\n                    A nine week take-home case study was completed with a single participant with upper limb amputation and osseointegration to better understand how an advanced prosthesis is used during daily activities. The participant was already an expert prosthesis user and used the Modular Prosthetic Limb (MPL) at home during the study. The MPL was controlled using wireless electromyography (EMG) pattern recognition-based movement decoding. Clinical assessments were performed before and after the take-home portion of the study. Data was recorded using an onboard data log in order to measure daily prosthesis usage, sensor data, and EMG data.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The participant\u2019s continuous prosthesis usage steadily increased (\n                    <jats:italic>p<\/jats:italic>\n                    = 0.04, max = 5.5 h) over time and over 30% of the total time was spent actively controlling the prosthesis. The duration of prosthesis usage after each pattern recognition training session also increased over time (\n                    <jats:italic>p<\/jats:italic>\n                    = 0.04), resulting in up to 5.4 h of usage before retraining the movement decoding algorithm. Pattern recognition control accuracy improved (1.2% per week,\n                    <jats:italic>p<\/jats:italic>\n                    &lt; 0.001) with a maximum number of ten classes trained at once and the transitions between different degrees of freedom increased as the study progressed, indicating smooth and efficient control of the advanced prosthesis. Variability of decoding accuracy also decreased with prosthesis usage (\n                    <jats:italic>p<\/jats:italic>\n                    &lt; 0.001) and 30% of the time was spent performing a prosthesis movement. During clinical evaluations, Box and Blocks and the Assessment of the Capacity for Myoelectric Control scores increased by 43% and 6.2%, respectively, demonstrating prosthesis functionality and the NASA Task Load Index scores decreased, on average, by 25% across assessments, indicating reduced cognitive workload while using the MPL, over the nine week study.\n                    <jats:italic>Significance<\/jats:italic>\n                    . In this case study, we demonstrate that an onboard system to monitor prosthesis usage enables better understanding of how prostheses are incorporated into daily life. That knowledge can support the long-term goal of completely restoring independence and quality of life to individuals living with upper limb amputation.\n                  <\/jats:p>","DOI":"10.1088\/1741-2552\/ac6d7b","type":"journal-article","created":{"date-parts":[[2022,5,6]],"date-time":"2022-05-06T18:16:54Z","timestamp":1651861014000},"page":"036021","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Monitoring at-home prosthesis control improvements through real-time data logging"],"prefix":"10.1088","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2985-6294","authenticated-orcid":true,"given":"Luke E","family":"Osborn","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Courtney W","family":"Moran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lauren D","family":"Dodd","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3586-2383","authenticated-orcid":false,"given":"Erin E","family":"Sutton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicolas","family":"Norena Acosta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jared M","family":"Wormley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Connor O","family":"Pyles","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kelles D","family":"Gordge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michelle J","family":"Nordstrom","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Josef A","family":"Butkus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan A","family":"Forsberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul F","family":"Pasquina","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3425-7552","authenticated-orcid":false,"given":"Matthew S","family":"Fifer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3437-1884","authenticated-orcid":false,"given":"Robert S","family":"Armiger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2022,5,30]]},"reference":[{"key":"jneac6d7bbib1","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1109\/ICORR.2019.8779539","type":"conference-proceedings","article-title":"Pattern recognition and direct control home use of a multi-articulating hand prosthesis","author":"Simon","year":"2019"},{"key":"jneac6d7bbib2","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1177\/0309364617728117","type":"journal-article","article-title":"The DEKA hand: a multifunction prosthetic terminal device\u2014patterns of grip usage at home","volume":"42","author":"Resnik","year":"2018","journal-title":"Prosthet. Orthot. Int."},{"key":"jneac6d7bbib3","doi-asserted-by":"publisher","first-page":"9866","DOI":"10.1038\/s41598-018-26952-x","type":"journal-article","article-title":"Home use of a neural-connected sensory prosthesis provides the functional and psychosocial experience of having a hand again","volume":"8","author":"Graczyk","year":"2018","journal-title":"Sci. Rep."},{"key":"jneac6d7bbib4","doi-asserted-by":"publisher","first-page":"1732","DOI":"10.1056\/NEJMoa1917537","type":"journal-article","article-title":"Self-contained neuromusculoskeletal arm prostheses","volume":"382","author":"Ortiz-Catalan","year":"2020","journal-title":"New Engl. J. Med."},{"key":"jneac6d7bbib5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fnins.2019.00853","type":"journal-article","article-title":"Learning of artificial sensation through long-term home use of a sensory-enabled prosthesis","volume":"13","author":"Cuberovic","year":"2019","journal-title":"Front. Neurosci."},{"key":"jneac6d7bbib6","doi-asserted-by":"publisher","first-page":"120","DOI":"10.3389\/fnins.2020.00120","type":"journal-article","article-title":"Long-term home-use of sensory-motor-integrated bidirectional bionic prosthetic arms promotes functional, perceptual, and cognitive changes","volume":"14","author":"Schofield","year":"2020","journal-title":"Front. Neurosci."},{"key":"jneac6d7bbib7","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/abe20d","type":"journal-article","article-title":"Extended home use of an advanced osseointegrated prosthetic arm improves function, performance, and control efficiency","volume":"18","author":"Osborn","year":"2021","journal-title":"J. Neural Eng."},{"key":"jneac6d7bbib8","first-page":"57","type":"conference-proceedings","article-title":"Long-term functional improvement with dexterous prosthetic limb","author":"Sutton","year":"2020"},{"key":"jneac6d7bbib9","doi-asserted-by":"publisher","first-page":"294","DOI":"10.3109\/17483107.2011.635405","type":"journal-article","article-title":"Prosthesis rejection in acquired major upper-limb amputees: a population-based survey","volume":"7","author":"\u00d8stlie","year":"2012","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"jneac6d7bbib10","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1682\/JRRD.2014.08.0192","type":"journal-article","article-title":"Differences in myoelectric and body-powered upper-limb prostheses: systematic literature review","volume":"52","author":"Carey","year":"2015","journal-title":"J. Rehabil. Res. Dev."},{"key":"jneac6d7bbib11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-72470-0","type":"journal-article","article-title":"Differential experiences of embodiment between body-powered and myoelectric prosthesis users","volume":"10","author":"Engdahl","year":"2020","journal-title":"Sci. Rep."},{"key":"jneac6d7bbib12","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/s12984-018-0361-3","type":"journal-article","article-title":"Evaluation of EMG pattern recognition for upper limb prosthesis control: a case study in comparison with direct myoelectric control","volume":"15","author":"Resnik","year":"2018","journal-title":"J. NeuroEng. Rehabil."},{"key":"jneac6d7bbib13","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1038\/s41551-016-0025","type":"journal-article","article-title":"Man\/machine interface based on the discharge timings of spinal motor neurons after targeted muscle reinnervation","volume":"1","author":"Farina","year":"2017","journal-title":"Nat. Biomed. Eng."},{"key":"jneac6d7bbib14","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1109\/TBME.2017.2719400","type":"journal-article","article-title":"Limb position tolerant pattern recognition for myoelectric prosthesis control with adaptive sparse representations from extreme learning","volume":"65","author":"Betthauser","year":"2017","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneac6d7bbib15","doi-asserted-by":"publisher","first-page":"379","DOI":"10.3389\/fnins.2017.00379","type":"journal-article","article-title":"Self-recalibrating surface EMG pattern recognition for neuroprosthesis control based on convolutional neural network","volume":"11","author":"Zhai","year":"2017","journal-title":"Front. Neurosci."},{"key":"jneac6d7bbib16","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TBME.2019.2943309","type":"journal-article","article-title":"Stable responsive EMG sequence prediction and adaptive reinforcement with temporal convolutional networks","volume":"67","author":"Betthauser","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneac6d7bbib17","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1001\/jama.2009.116","type":"journal-article","article-title":"Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms","volume":"301","author":"Kuiken","year":"2009","journal-title":"J. Am. Med. Assoc."},{"key":"jneac6d7bbib18","doi-asserted-by":"publisher","first-page":"eaay2857","DOI":"10.1126\/scitranslmed.aay2857","type":"journal-article","article-title":"A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees","volume":"12","author":"Vu","year":"2020","journal-title":"Sci. Trans. Med."},{"key":"jneac6d7bbib19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-019-45459-7","type":"journal-article","article-title":"Proprioceptive sonomyographic control: a novel method for intuitive and proportional control of multiple degrees-of-freedom for individuals with upper extremity limb loss","volume":"9","author":"Dhawan","year":"2019","journal-title":"Sci. Rep."},{"key":"jneac6d7bbib20","doi-asserted-by":"publisher","DOI":"10.1101\/2020.12.23.20248489","type":"preprint","article-title":"Motion prediction using electromyography and sonomyography for an individual with transhumeral limb loss","author":"Engdahl","year":"2020"},{"key":"jneac6d7bbib21","doi-asserted-by":"publisher","first-page":"2052","DOI":"10.1523\/JNEUROSCI.1494-21.2021","type":"journal-article","article-title":"Frequency shapes the quality of tactile percepts evoked through electrical stimulation of the nerves","volume":"42","author":"Graczyk","year":"2021","journal-title":"J. Neurosci."},{"key":"jneac6d7bbib22","first-page":"147","type":"conference-proceedings","article-title":"Phantom hand activation during physical touch and targeted transcutaneous electrical nerve stimulation","author":"Osborn","year":"2020"},{"key":"jneac6d7bbib23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/BIOCAS.2017.8325200","type":"conference-proceedings","article-title":"Targeted transcutaneous electrical nerve stimulation for phantom limb sensory feedback","author":"Osborn","year":"2017"},{"key":"jneac6d7bbib24","doi-asserted-by":"publisher","DOI":"10.7554\/eLife.54349","type":"journal-article","article-title":"Sensory restoration by epidural stimulation of the lateral spinal cord in upper-limb amputees","volume":"9","author":"Chandrasekaran","year":"2020","journal-title":"eLife"},{"key":"jneac6d7bbib25","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-67032-3","type":"journal-article","article-title":"Ambulatory searching task reveals importance of somatosensation for lower-limb amputees","volume":"10","author":"Christie","year":"2020","journal-title":"Sci. Rep."},{"key":"jneac6d7bbib26","doi-asserted-by":"publisher","first-page":"eaat3818","DOI":"10.1126\/scirobotics.aat3818","type":"journal-article","article-title":"Prosthesis with neuromorphic multilayered e-dermis perceives touch and pain","volume":"3","author":"Osborn","year":"2018","journal-title":"Sci. Robot."},{"key":"jneac6d7bbib27","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.neulet.2011.10.068","type":"journal-article","article-title":"Sensory feedback prosthesis reduces phantom limb pain: proof of a principle","volume":"507","author":"Dietrich","year":"2012","journal-title":"Neurosci. Lett."},{"key":"jneac6d7bbib28","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/abb861","type":"journal-article","article-title":"Sensory stimulation enhances phantom limb perception and movement decoding","volume":"17","author":"Osborn","year":"2020","journal-title":"J. Neural Eng."},{"key":"jneac6d7bbib29","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/ab882d","type":"journal-article","article-title":"Towards machine to brain interfaces: sensory stimulation enhances sensorimotor dynamic functional connectivity in upper limb amputees","volume":"17","author":"Ding","year":"2020","journal-title":"J. Neural Eng."},{"key":"jneac6d7bbib30","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1177\/0309364611409003","type":"journal-article","article-title":"Osseointegration amputation prostheses on the upper limbs: methods, prosthetics and rehabilitation","volume":"35","author":"J\u00f6nsson","year":"2011","journal-title":"Prosthet. Orthot. Int."},{"key":"jneac6d7bbib31","doi-asserted-by":"publisher","first-page":"257re6","DOI":"10.1126\/scitranslmed.3008933","type":"journal-article","article-title":"An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs","volume":"6","author":"Ortiz-Catalan","year":"2014","journal-title":"Sci. Trans. Med."},{"key":"jneac6d7bbib32","doi-asserted-by":"publisher","first-page":"1369","DOI":"10.1007\/s10439-019-02244-x","type":"journal-article","article-title":"Loads on transhumeral amputees using osseointegrated prostheses","volume":"47","author":"Stenlund","year":"2019","journal-title":"Ann. Biomed. Eng."},{"key":"jneac6d7bbib33","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-29503-6","type":"journal-article","article-title":"Upper limb activity in myoelectric prosthesis users is biased towards the intact limb and appears unrelated to goal-directed task performance","volume":"8","author":"Chadwell","year":"2018","journal-title":"Sci. Rep."},{"key":"jneac6d7bbib34","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1186\/s12984-020-00711-4","type":"journal-article","article-title":"Technology for monitoring everyday prosthesis use: a systematic review","volume":"17","author":"Chadwell","year":"2020","journal-title":"J. NeuroEng. Rehabil."},{"key":"jneac6d7bbib35","doi-asserted-by":"publisher","DOI":"10.3389\/frobt.2020.559034","type":"journal-article","article-title":"Portable take-home system enables proportional control and high-resolution data logging with a multi-degree-of-freedom bionic arm","volume":"7","author":"Brinton","year":"2020","journal-title":"Front. Robot. AI"},{"key":"jneac6d7bbib36","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/B978-0-12-814659-0.00021-7","type":"book","author":"Johannes","year":"2020"},{"key":"jneac6d7bbib37","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-79581-8","type":"journal-article","article-title":"Clinical evaluation of the revolutionizing prosthetics modular prosthetic limb system for upper extremity amputees","volume":"11","author":"Yu","year":"2021","journal-title":"Sci. Rep."},{"key":"jneac6d7bbib38","doi-asserted-by":"publisher","first-page":"386","DOI":"10.5014\/ajot.39.6.386","type":"journal-article","article-title":"Adult norms for the box and block test of manual dexterity","volume":"39","author":"Mathiowetz","year":"1985","journal-title":"Am. J. Occup. Ther."},{"key":"jneac6d7bbib39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/2055668317750810","type":"journal-article","article-title":"Characterisation of the clothespin relocation test as a functional assessment tool","volume":"5","author":"Kyberd","year":"2018","journal-title":"J. Rehabil. Assist. Technol. Eng."},{"key":"jneac6d7bbib40","first-page":"311","type":"journal-article","article-title":"An objective and standardized test of hand function","volume":"50","author":"Jebsen","year":"1969","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"jneac6d7bbib41","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1080\/16501970410024280","type":"journal-article","article-title":"Assessmet of capacity for myoelectric control: a new rasch-built measure of prosthetic hand control","volume":"37","author":"Hermansson","year":"2005","journal-title":"J. Rehabil. Med."},{"key":"jneac6d7bbib42","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/S0166-4115(08)62386-9","type":"journal-article","article-title":"Development of NASA-TLX (task load index): results of empirical and theoretical research","volume":"52","author":"Hart","year":"1988","journal-title":"Adv. Psychol."},{"key":"jneac6d7bbib43","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0186132","type":"journal-article","article-title":"Comparison of six electromyography acquisition setups on hand movement classification tasks","volume":"12","author":"Pizzolato","year":"2017","journal-title":"PLoS One"},{"key":"jneac6d7bbib44","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1109\/TBME.2003.813539","type":"journal-article","article-title":"A robust, real-time control scheme for multifunction myoelectric control","volume":"50","author":"Englehart","year":"2003","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneac6d7bbib45","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1682\/JRRD.2010.08.0149","type":"journal-article","article-title":"Target achievement control test: evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses","volume":"48","author":"Simon","year":"2011","journal-title":"J. Rehabil. Res. Dev."},{"key":"jneac6d7bbib46","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1177\/1523422319869915","type":"journal-article","article-title":"Principle assumptions of regression analysis: testing, techniques, and statistical reporting of imperfect data sets","volume":"21","author":"Flatt","year":"2019","journal-title":"Adv. Dev. Hum. Resour."},{"key":"jneac6d7bbib47","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.anbehav.2015.01.010","type":"journal-article","article-title":"Effective use of Spearman\u2019s and Kendall\u2019s correlation coefficients forassociation between two measured traits","volume":"102","author":"Puth","year":"2015","journal-title":"Anim. Behav."},{"key":"jneac6d7bbib48","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/BIOCAS.2017.8325201","type":"conference-proceedings","article-title":"Electrode-shift tolerant myoelectric movement-pattern classification using extreme learning for adaptive sparse representations","author":"Betthauser","year":"2017"},{"key":"jneac6d7bbib49","doi-asserted-by":"publisher","DOI":"10.1109\/BIOCAS.2018.8584757","type":"conference-proceedings","article-title":"Registration of EMG electrodes to reduce classification errors due to electrode shift","author":"Steinhardt","year":"2018"},{"key":"jneac6d7bbib50","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1007\/s00221-008-1355-3","type":"journal-article","article-title":"The statistics of natural hand movements","volume":"188","author":"Ingram","year":"2008","journal-title":"Exp. Brain Res."},{"key":"jneac6d7bbib51","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1097\/JPO.0b013e31826ff91c","type":"journal-article","article-title":"Reliability and validity of outcome measures for upper limb amputation","volume":"24","author":"Resnik","year":"2012","journal-title":"J. Prosthet. Orthot."},{"key":"jneac6d7bbib52","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/j.pmrj.2018.02.008","type":"journal-article","article-title":"Evaluation of performance-based outcome measures for the upper limb: a comprehensive narrative review","volume":"10","author":"Wang","year":"2018","journal-title":"PM&R"}],"container-title":["Journal of Neural Engineering"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,22]],"date-time":"2025-11-22T14:59:34Z","timestamp":1763823574000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7b"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,30]]},"references-count":52,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022,5,30]]},"published-print":{"date-parts":[[2022,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1741-2552\/ac6d7b","relation":{},"ISSN":["1741-2560","1741-2552"],"issn-type":[{"type":"print","value":"1741-2560"},{"type":"electronic","value":"1741-2552"}],"subject":[],"published":{"date-parts":[[2022,5,30]]},"assertion":[{"value":"Monitoring at-home prosthesis control improvements through real-time data logging","name":"article_title","label":"Article Title"},{"value":"Journal of Neural Engineering","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2021-11-15","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-05-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-05-30","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}