{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T15:44:49Z","timestamp":1790696689718,"version":"4.1.0"},"reference-count":41,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T00:00:00Z","timestamp":1653609600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T00:00:00Z","timestamp":1653609600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001703","name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001703","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100001711","name":"Swiss National Science Foundation","doi-asserted-by":"crossref","award":["200021_182670"],"award-info":[{"award-number":["200021_182670"]}],"id":[{"id":"10.13039\/501100001711","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100016304","name":"Medtronic plc","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100016304","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Neural Eng."],"published-print":{"date-parts":[[2022,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> Intraneural nerve interfaces often operate in a monopolar configuration with a common and distant ground electrode. This configuration leads to a wide spreading of the electric field. Therefore, this approach is suboptimal for intraneural nerve interfaces when selective stimulation is required. <jats:italic>Approach.<\/jats:italic> We designed a multilayer electrode array embedding three-dimensional concentric bipolar (CB) electrodes. First, we validated the higher stimulation selectivity of this new electrode array compared to classical monopolar stimulation using simulations. Next, we compared them <jats:italic>in-vivo<\/jats:italic> by intraneural stimulation of the rabbit optic nerve and recording evoked potentials in the primary visual cortex. <jats:italic>Main results.<\/jats:italic> Simulations showed that three-dimensional CB electrodes provide a high localisation of the electric field in the tissue so that electrodes are electrically independent even for high electrode density. Experiments <jats:italic>in-vivo<\/jats:italic> highlighted that this configuration restricts spatial activation in the visual cortex due to the fewer fibres activated by the electric stimulus in the nerve. <jats:italic>Significance.<\/jats:italic> Highly focused electric stimulation is crucial to achieving high selectivity in fibre activation. The multilayer array embedding three-dimensional CB electrodes improves selectivity in optic nerve stimulation. This approach is suitable for other neural applications, including bioelectronic medicine.<\/jats:p>","DOI":"10.1088\/1741-2552\/ac6d7e","type":"journal-article","created":{"date-parts":[[2022,5,6]],"date-time":"2022-05-06T22:18:11Z","timestamp":1651875491000},"page":"036016","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":15,"title":["Three-dimensional multilayer concentric bipolar electrodes restrict spatial activation in optic nerve stimulation"],"prefix":"10.1088","volume":"19","author":[{"given":"Eleonora","family":"Borda","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vivien","family":"Gaillet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9646-5264","authenticated-orcid":true,"given":"Marta Jole Ildelfonsa","family":"Airaghi Leccardi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elodie Genevi\u00e8ve","family":"Zollinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ricardo Camilo","family":"Moreira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0554-7510","authenticated-orcid":true,"given":"Diego","family":"Ghezzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2022,5,27]]},"reference":[{"key":"jneac6d7ebib1","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1016\/j.mayocp.2017.05.005","article-title":"Neurostimulation devices for the treatment of neurologic disorders","volume":"92","author":"Edwards","year":"2017","journal-title":"Mayo Clin. Proc."},{"key":"jneac6d7ebib2","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1007\/s13311-018-0667-7","article-title":"Directional deep brain stimulation","volume":"16","author":"Steigerwald","year":"2019","journal-title":"Neurotherapeutics"},{"key":"jneac6d7ebib3","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.heares.2017.10.005","article-title":"An overview of cochlear implant electrode array designs","volume":"356","author":"Dhanasingh","year":"2017","journal-title":"Hear. Res."},{"key":"jneac6d7ebib4","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1038\/s41467-018-03386-7","article-title":"Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis","volume":"9","author":"Ferlauto","year":"2018","journal-title":"Nat. Commun."},{"key":"jneac6d7ebib5","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1038\/s43246-021-00133-2","article-title":"Photovoltaic retinal prosthesis restores high-resolution responses to single-pixel stimulation in blind retinas","volume":"2","author":"Chenais","year":"2021","journal-title":"Commun. Mater."},{"key":"jneac6d7ebib6","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1038\/s41551-020-0520-2","article-title":"Translation of a photovoltaic retinal prosthesis","volume":"4","author":"Ghezzi","year":"2020","journal-title":"Nat. Biomed. Eng."},{"key":"jneac6d7ebib7","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1113\/jphysiol.1974.sp010766","article-title":"Phosphenes produced by electrical stimulation of human occipital cortex, and their application to the development of a prosthesis for the blind","volume":"243","author":"Dobelle","year":"1974","journal-title":"J. Physiol."},{"key":"jneac6d7ebib8","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1093\/brain\/119.2.507","article-title":"Feasibility of a visual prosthesis for the blind based on intracortical micro stimulation of the visual cortex","volume":"119","author":"Schmidt","year":"1996","journal-title":"Brain"},{"key":"jneac6d7ebib9","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.preteyeres.2015.09.003","article-title":"The Argus\u00ae II retinal prosthesis system","volume":"50","author":"Luo","year":"2016","journal-title":"Prog. Retin. Eye Res."},{"key":"jneac6d7ebib10","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0115239","article-title":"First-in-human trial of a novel suprachoroidal retinal prosthesis ed K Mori","volume":"9","author":"Ayton","year":"2014","journal-title":"PLoS One"},{"key":"jneac6d7ebib11","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1515\/bmt-2011-0140","article-title":"Development of a neurotechnological system for relieving phantom limb pain using transverse intrafascicular electrodes (TIME)","volume":"57","author":"Stieglitz","year":"2012","journal-title":"Biomed. Tech. Eng."},{"key":"jneac6d7ebib12","doi-asserted-by":"publisher","first-page":"1489","DOI":"10.1098\/rspb.2010.1747","article-title":"Subretinal electronic chips allow blind patients to read letters and combine them to words","volume":"278","author":"Zrenner","year":"2011","journal-title":"Proc. Biol. Sci."},{"key":"jneac6d7ebib13","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0073130","article-title":"Quasi-monopolar stimulation: a novel electrode design configuration for performance optimization of a retinal neuroprosthesis","volume":"8","author":"Moghadam","year":"2013","journal-title":"PLoS One"},{"key":"jneac6d7ebib14","doi-asserted-by":"publisher","first-page":"6467","DOI":"10.1167\/iovs.13-13026","article-title":"Factors affecting perceptual thresholds in a suprachoroidal retinal prosthesis","volume":"55","author":"Shivdasani","year":"2014","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"jneac6d7ebib15","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/9\/3\/036009","article-title":"Visual cortex responses to suprachoroidal electrical stimulation of the retina: effects of electrode return configuration","volume":"9","author":"Cicione","year":"2012","journal-title":"J. Neural Eng."},{"key":"jneac6d7ebib16","doi-asserted-by":"publisher","first-page":"3181","DOI":"10.1167\/iovs.16-19325","article-title":"Spatial restriction of neural activation using focused multipolar stimulation with a retinal prosthesis","volume":"57","author":"Spencer","year":"2016","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"jneac6d7ebib17","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/aae191","article-title":"Multilayer 3D electrodes for neural implants","volume":"16","author":"Leccardi","year":"2018","journal-title":"J. Neural Eng."},{"key":"jneac6d7ebib18","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1038\/s41551-019-0446-8","article-title":"Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve","volume":"4","author":"Gaillet","year":"2020","journal-title":"Nat. Biomed. Eng."},{"key":"jneac6d7ebib19","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/abf523","article-title":"A machine-learning algorithm correctly classifies cortical evoked potentials from both visual stimulation and electrical stimulation of the optic nerve","volume":"18","author":"Gaillet","year":"2021","journal-title":"J. Neural Eng."},{"key":"jneac6d7ebib20","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/10\/6\/066007","article-title":"A simulation of current focusing and steering with penetrating optic nerve electrodes","volume":"10","author":"Li","year":"2013","journal-title":"J. Neural Eng."},{"key":"jneac6d7ebib21","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1113\/jphysiol.1952.sp004764","article-title":"A quantitative description of membrane current and its application to conduction and excitation in nerve","volume":"117","author":"Hodgkin","year":"1952","journal-title":"J. Physiol."},{"key":"jneac6d7ebib22","doi-asserted-by":"publisher","first-page":"2513","DOI":"10.1016\/j.visres.2006.01.021","article-title":"A model of the mammalian optic nerve fibre based on experimental data","volume":"46","author":"Oozeer","year":"2006","journal-title":"Vision Res."},{"key":"jneac6d7ebib23","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/S0165-0270(99)00113-2","article-title":"A new planar multielectrode array for extracellular recording: application to hippocampal acute slice","volume":"93","author":"Oka","year":"1999","journal-title":"J. Neurosci. Methods"},{"key":"jneac6d7ebib24","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/13\/3\/036003","article-title":"Spectral distribution of local field potential responses to electrical stimulation of the retina","volume":"13","author":"Wong","year":"2016","journal-title":"J. Neural Eng."},{"key":"jneac6d7ebib25","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/13\/3\/036010","article-title":"Optimization of return electrodes in neurostimulating arrays","volume":"13","author":"Flores","year":"2016","journal-title":"J. Neural Eng."},{"key":"jneac6d7ebib26","doi-asserted-by":"publisher","first-page":"4307","DOI":"10.1167\/iovs.13-11653","article-title":"Current steering in retinal stimulation via a quasimonopolar stimulation paradigm","volume":"54","author":"Matteucci","year":"2013","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"jneac6d7ebib27","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.biomaterials.2015.07.018","article-title":"Synthetic 3D diamond-based electrodes for flexible retinal neuroprostheses: model, production and in vivo biocompatibility","volume":"67","author":"Bendali","year":"2015","journal-title":"Biomaterials"},{"key":"jneac6d7ebib28","doi-asserted-by":"publisher","first-page":"e4828","DOI":"10.1371\/journal.pone.0004828","article-title":"Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study","volume":"4","author":"Joucla","year":"2009","journal-title":"PLoS One"},{"key":"jneac6d7ebib29","doi-asserted-by":"publisher","first-page":"13","DOI":"10.3389\/fncom.2014.00013","article-title":"Current approaches to model extracellular electrical neural microstimulation","volume":"8","author":"Joucla","year":"2014","journal-title":"Front. Comput. Neurosci."},{"key":"jneac6d7ebib30","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1016\/j.jneumeth.2010.02.004","article-title":"A non-linear regression analysis method for quantitative resolution of the stimulus-evoked compound action potential from rodent optic nerve","volume":"188","author":"Evans","year":"2010","journal-title":"J. Neurosci. Methods"},{"key":"jneac6d7ebib31","doi-asserted-by":"publisher","author":"Jolliffe","year":"2002","DOI":"10.1007\/b98835"},{"key":"jneac6d7ebib32","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.jneumeth.2015.07.005","article-title":"An assumption-free quantification of neural responses to electrical stimulations","volume":"254","author":"Ruach","year":"2015","journal-title":"J. Neurosci. Methods"},{"key":"jneac6d7ebib33","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1016\/j.visres.2009.02.018","article-title":"Focal activation of the feline retina via a suprachoroidal electrode array","volume":"49","author":"Wong","year":"2009","journal-title":"Vision Res."},{"key":"jneac6d7ebib34","doi-asserted-by":"publisher","first-page":"14453","DOI":"10.1073\/pnas.1916787117","article-title":"Functional ultrasound imaging of deep visual cortex in awake nonhuman primates","volume":"117","author":"Blaize","year":"2020","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"jneac6d7ebib35","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.neuroimage.2015.08.071","article-title":"Imaging fast electrical activity in the brain with electrical impedance tomography","volume":"124","author":"Aristovich","year":"2016","journal-title":"NeuroImage"},{"key":"jneac6d7ebib36","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/abcdbe","article-title":"Compliant peripheral nerve interfaces","volume":"18","author":"Paggi","year":"2021","journal-title":"J. Neural Eng."},{"key":"jneac6d7ebib37","doi-asserted-by":"publisher","first-page":"24","DOI":"10.3389\/fnsys.2018.00024","article-title":"Engineering artificial somatosensation through cortical stimulation in humans","volume":"12","author":"Lee","year":"2018","journal-title":"Front. Syst. Neurosci."},{"key":"jneac6d7ebib38","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1016\/j.cell.2020.04.033","article-title":"Dynamic stimulation of visual cortex produces form vision in sighted and blind humans","volume":"181","author":"Beauchamp","year":"2020","journal-title":"Cell"},{"key":"jneac6d7ebib39","doi-asserted-by":"publisher","first-page":"0460a2","DOI":"10.1088\/1741-2552\/ac0d42","article-title":"Simultaneous decoding of cardiovascular and respiratory functional changes from pig intraneural vagus nerve signals","volume":"18","author":"Vallone","year":"2021","journal-title":"J. Neural Eng."},{"key":"jneac6d7ebib40","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2021.685872","article-title":"Selective neuromodulation of the vagus nerve","volume":"15","author":"Fitchett","year":"2021","journal-title":"Front. Neurosci."},{"key":"jneac6d7ebib41","doi-asserted-by":"publisher","first-page":"e791","DOI":"10.1097\/JU.0000000000000916.01","article-title":"MP54-01 soft silicone electrode net for modulating bladder function","volume":"203","author":"Kumar","year":"2020","journal-title":"J. Urol."}],"container-title":["Journal of Neural Engineering"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T12:50:55Z","timestamp":1653655855000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/ac6d7e"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,27]]},"references-count":41,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022,5,27]]},"published-print":{"date-parts":[[2022,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1741-2552\/ac6d7e","relation":{},"ISSN":["1741-2560","1741-2552"],"issn-type":[{"value":"1741-2560","type":"print"},{"value":"1741-2552","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,27]]},"assertion":[{"value":"Three-dimensional multilayer concentric bipolar electrodes restrict spatial activation in optic nerve stimulation","name":"article_title","label":"Article Title"},{"value":"Journal of Neural Engineering","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2021-12-05","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-05-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-05-27","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}