{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T12:29:12Z","timestamp":1766492952995,"version":"3.37.3"},"reference-count":62,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2023,5,9]],"date-time":"2023-05-09T00:00:00Z","timestamp":1683590400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,5,9]],"date-time":"2023-05-09T00:00:00Z","timestamp":1683590400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"crossref","award":["EP\/R004242\/2"],"award-info":[{"award-number":["EP\/R004242\/2"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100000272","name":"National Institute for Health Research","doi-asserted-by":"crossref","award":["STWK-006"],"award-info":[{"award-number":["STWK-006"]}],"id":[{"id":"10.13039\/501100000272","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Neural Eng."],"published-print":{"date-parts":[[2023,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> The objective of this study was to assess the impact of delayed feedback training on the retention of novel myoelectric skills, and to demonstrate the use of this training approach in the home environment. <jats:italic>Approach.<\/jats:italic> We trained limb-intact participants to use a motor learning-based upper-limb prosthesis control scheme called abstract decoding. A delayed feedback paradigm intended to prevent within-trial adaptation and to facilitate motor learning was used. We conducted two multi-day experiments. Experiment 1 was a laboratory-based study consisting of two groups trained over a 4\u2009day period with concurrent or delayed feedback. An additional follow-up session took place after 18\u2009days to assess the retention of motor skills. Experiment 2 was a home-based pilot study that took place over five consecutive days to investigate delayed feedback performance when using bespoke training structures. <jats:italic>Main Results.<\/jats:italic> Approximately 35\u2009000 trials were collected across both experiments. Experiment 1 found that the retention of motor skills for the delayed feedback group was significantly better than that of their concurrent feedback counterparts. In addition, the delayed feedback group improved their retention of motor skills across days, whereas the concurrent feedback group did not. Experiment 2 demonstrated that by using a bespoke training protocol in an environment that is more conducive to learning, it is possible for participants to become highly accurate in the absence of feedback. <jats:italic>Significance.<\/jats:italic> These results show that with delayed feedback training, it is possible to retain novel myoelectric skills. Using abstract decoding participants can activate four distinct muscle patterns without using complex algorithms. The accuracy achieved in the pilot study supports the feasibility of motor learning-based upper-limb prosthesis control after home-based myoelectric training.<\/jats:p>","DOI":"10.1088\/1741-2552\/acc4ea","type":"journal-article","created":{"date-parts":[[2023,3,16]],"date-time":"2023-03-16T22:30:41Z","timestamp":1679005841000},"page":"036008","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["Delaying feedback during pre-device training facilitates the retention of novel myoelectric skills: a laboratory and home-based study"],"prefix":"10.1088","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5311-8470","authenticated-orcid":true,"given":"Simon A","family":"Stuttaford","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0332-3764","authenticated-orcid":true,"given":"Sigrid S G","family":"Dupan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4217-0254","authenticated-orcid":true,"given":"Kianoush","family":"Nazarpour","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8707-0137","authenticated-orcid":true,"given":"Matthew","family":"Dyson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2023,5,9]]},"reference":[{"key":"jneacc4eabib1","first-page":"pp 32.1","article-title":"Design of artificial arms and hands for prosthetic applications","author":"Weir","year":"2003"},{"key":"jneacc4eabib2","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1109\/10.1371","article-title":"The electromyogram EMG as a control signal for functional neuromuscular stimulation-part II: practical demonstration of the EMG signature discrimination system","volume":"35","author":"Hefftner","year":"1988","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"jneacc4eabib3","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1615\/CritRevBiomedEng.v30.i456.80","article-title":"Control of multifunctional prosthetic hands by processing the electromyographic signal","volume":"30","author":"Zecca","year":"2002","journal-title":"Crit. Rev. Biomed. Eng."},{"year":"2004","author":"Muzumdar","key":"jneacc4eabib4"},{"key":"jneacc4eabib5","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-14386-w","article-title":"Myoelectric pattern recognition outperforms direct control for transhumeral amputees with targeted muscle reinnervation: a randomized clinical trial","volume":"7","author":"Hargrove","year":"2017","journal-title":"Sci. Rep."},{"key":"jneacc4eabib6","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1109\/86.481972","article-title":"EMG feature evaluation for movement control of upper extremity prostheses","volume":"3","author":"Zardoshti-Kermani","year":"1995","journal-title":"IEEE Trans. Rehabil. Eng."},{"key":"jneacc4eabib7","doi-asserted-by":"publisher","first-page":"95","DOI":"10.3233\/TAD-2003-15205","article-title":"Continuous multifunction myoelectric control using pattern recognition","volume":"15","author":"Englehart","year":"2003","journal-title":"Technol. Disabil."},{"key":"jneacc4eabib8","first-page":"pp 61","article-title":"Prosthesis-guided training for practical use of pattern recognition control of prostheses","author":"Lock","year":"2011"},{"key":"jneacc4eabib9","first-page":"pp 1","article-title":"Online human training of a myoelectric prosthesis controller via actor-critic reinforcement learning","author":"Pilarski","year":"2011"},{"key":"jneacc4eabib10","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1109\/MSP.2012.2203480","article-title":"Myoelectric control of artificial limbs\u2013is there a need to change focus?","volume":"29","author":"Jiang","year":"2012","journal-title":"IEEE Signal Process. Mag."},{"key":"jneacc4eabib11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1743-0003-11-16","article-title":"Changes in performance over time while learning to use a myoelectric prosthesis","volume":"11","author":"Bouwsema","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"jneacc4eabib12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/1741-2552\/aa87cf","article-title":"Model and experiments to optimize co-adaptation in a simplified myoelectric control system","volume":"15","author":"Couraud","year":"2018","journal-title":"J. Neural Eng."},{"key":"jneacc4eabib13","doi-asserted-by":"publisher","first-page":"361","DOI":"10.3389\/fbioe.2020.00361","article-title":"The merits of dynamic data acquisition for realistic myocontrol","volume":"8","author":"Gigli","year":"2020","journal-title":"Front. Bioeng. Biotechnol."},{"key":"jneacc4eabib14","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2019.101572","article-title":"Common spatial-spectral analysis of EMG signals for multiday and multiuser myoelectric interface","volume":"53","author":"Sheng","year":"2019","journal-title":"Biomed. Signal Process. Control"},{"key":"jneacc4eabib15","doi-asserted-by":"publisher","first-page":"2087","DOI":"10.1109\/TNSRE.2019.2929917","article-title":"The effect of feedback during training sessions on learning pattern-recognition-based prosthesis control","volume":"27","author":"Kristoffersen","year":"2019","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"jneacc4eabib16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1743-0003-9-40","article-title":"Real-time myoelectric control of a multi-fingered hand prosthesis using principal components analysis","volume":"9","author":"Matrone","year":"2012","journal-title":"J. Neuroeng. Rehabil."},{"key":"jneacc4eabib17","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/aae9d4","article-title":"On the robustness of real-time myoelectric control investigations: a multiday Fitts\u2019 law approach","volume":"16","author":"Waris","year":"2019","journal-title":"J. Neural Eng."},{"key":"jneacc4eabib18","doi-asserted-by":"publisher","first-page":"e179","DOI":"10.1371\/journal.pbio.0040179","article-title":"Interacting adaptive processes with different timescales underlie short-term motor learning","volume":"4","author":"Smith","year":"2006","journal-title":"PLoS Biol."},{"key":"jneacc4eabib19","doi-asserted-by":"publisher","first-page":"9568","DOI":"10.1523\/JNEUROSCI.5061-14.2015","article-title":"Explicit and implicit processes constitute the fast and slow processes of sensorimotor learning","volume":"35","author":"McDougle","year":"2015","journal-title":"J. Neurosci."},{"key":"jneacc4eabib20","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1080\/00336297.1994.10484129","article-title":"The influence of augmented feedback on skill learning depends on characteristics of the skill and the learner","volume":"46","author":"Magill","year":"1994","journal-title":"Quest"},{"key":"jneacc4eabib21","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1037\/0033-2909.95.3.355","article-title":"Knowledge of results and motor learning: a review and critical reappraisal","volume":"95","author":"Salmoni","year":"1984","journal-title":"Psychol. Bull."},{"key":"jneacc4eabib22","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0037900","article-title":"Adaptation to visual feedback delay influences visuomotor learning","volume":"7","author":"Honda","year":"2012","journal-title":"PLoS One"},{"key":"jneacc4eabib23","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.nlm.2017.02.015","article-title":"Feedback delay attenuates implicit but facilitates explicit adjustments to a visuomotor rotation","volume":"140","author":"Schween","year":"2017","journal-title":"Neurobiol. Learn. Mem."},{"key":"jneacc4eabib24","doi-asserted-by":"publisher","first-page":"7644","DOI":"10.1523\/JNEUROSCI.15-11-07644.1995","article-title":"Effects of delayed visual information on the rate and amount of prism adaptation in the human","volume":"15","author":"Kitazawa","year":"1995","journal-title":"J. Neurosci."},{"key":"jneacc4eabib25","doi-asserted-by":"publisher","first-page":"535","DOI":"10.2466\/pms.1988.66.2.535","article-title":"Effect of bandwidth knowledge of results on movement consistency","volume":"66","author":"Sherwood","year":"1988","journal-title":"Percept. Mot. Skills"},{"key":"jneacc4eabib26","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1037\/0278-7393.16.4.677","article-title":"Reduced frequency of knowledge of results enhances motor skill learning","volume":"16","author":"Winstein","year":"1990","journal-title":"J. Exp. Psychol. Learn. Mem. Cogn."},{"key":"jneacc4eabib27","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1080\/00222895.1992.9941621","article-title":"Augmented kinematic feedback for motor learning","volume":"24","author":"Young","year":"1992","journal-title":"J. Mot. Behav."},{"key":"jneacc4eabib28","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1080\/00222890009601379","article-title":"Reduced-frequency concurrent and terminal feedback: a test of the guidance hypothesis","volume":"32","author":"Park","year":"2000","journal-title":"J. Mot. Behav."},{"key":"jneacc4eabib29","doi-asserted-by":"publisher","first-page":"2687","DOI":"10.1007\/s10439-013-0876-5","article-title":"Abstract and proportional myoelectric control for multi-fingered hand prostheses","volume":"41","author":"Pistohl","year":"2013","journal-title":"Ann. Biomed. Eng."},{"key":"jneacc4eabib30","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/aacbfe","article-title":"Myoelectric control with abstract decoders","volume":"15","author":"Dyson","year":"2018","journal-title":"J. Neural Eng."},{"key":"jneacc4eabib31","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1109\/TNSRE.2020.3000310","article-title":"Learning, generalization and scalability of abstract myoelectric control","volume":"28","author":"Dyson","year":"2020","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"jneacc4eabib32","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1109\/TNSRE.2014.2302212","article-title":"Embedded human control of robots using myoelectric interfaces","volume":"22","author":"Antuvan","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"jneacc4eabib33","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1109\/TRO.2015.2395731","article-title":"Proportional myoelectric control of robots: muscle synergy development drives performance enhancement, retainment and generalization","volume":"31","author":"Ison","year":"2015","journal-title":"IEEE Trans. Robot."},{"key":"jneacc4eabib34","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1109\/TNSRE.2014.2355856","article-title":"Artificial proprioceptive feedback for myoelectric control","volume":"23","author":"Pistohl","year":"2015","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"jneacc4eabib35","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1682\/JRRD.2014.05.0134","article-title":"Novel postural control algorithm for control of multifunctional myoelectric prosthetic hands","volume":"52","author":"Segil","year":"2015","journal-title":"J. Rehabil. Res. Dev."},{"key":"jneacc4eabib36","doi-asserted-by":"crossref","DOI":"10.32657\/10220\/48046","article-title":"Decoding human motion intention using myoelectric signals for assistive technologies","author":"Antuvan","year":"2019"},{"key":"jneacc4eabib37","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1109\/MRA.2019.2949688","article-title":"A myoelectric postural control algorithm for persons with transradial amputation: A consideration of clinical readiness","volume":"27","author":"Segil","year":"2020","journal-title":"IEEE Robot. Autom. Mag."},{"key":"jneacc4eabib38","doi-asserted-by":"publisher","first-page":"2546","DOI":"10.1152\/jn.01044.2007","article-title":"Contributions of online visual feedback to the learning and generalization of novel finger coordination patterns","volume":"99","author":"Liu","year":"2008","journal-title":"J. Neurophysiol."},{"key":"jneacc4eabib39","doi-asserted-by":"publisher","first-page":"1317","DOI":"10.1016\/S0893-6080(98)00066-5","article-title":"Multiple paired forward and inverse models for motor control","volume":"11","author":"Wolpert","year":"1998","journal-title":"Neural Netw."},{"key":"jneacc4eabib40","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/B978-0-444-53752-2.00014-X","article-title":"Sensory motor remapping of space in human\u2013machine interfaces","volume":"191","author":"Mussa-Ivaldi","year":"2011","journal-title":"Prog. Brain Res."},{"key":"jneacc4eabib41","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1097\/PXR.0000000000000083","article-title":"A scoping review of the application of motor learning principles to optimize myoelectric prosthetic hand control","volume":"46","author":"Parr","year":"2021","journal-title":"Prosthet. Orthot. Int."},{"key":"jneacc4eabib42","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1109\/TNSRE.2007.891391","article-title":"The optimal controller delay for myoelectric prostheses","volume":"15","author":"Farrell","year":"2007","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"jneacc4eabib43","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0160817","article-title":"Learning an EMG controlled game: task specific adaptations and transfer","volume":"11","author":"van Dijkvan Dijk","year":"2016","journal-title":"PLoS One"},{"key":"jneacc4eabib44","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s12984-021-00831-5","article-title":"User training for machine learning controlled upper limb prostheses: a serious game approach","volume":"18","author":"Kristoffersen","year":"2021","journal-title":"J. Neuroeng. Rehabil."},{"key":"jneacc4eabib45","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1186\/s12984-021-00878-4","article-title":"Transfer of mode switching performance: from training to upper-limb prosthesis use","volume":"18","author":"Heerschop","year":"2021","journal-title":"J. Neuroeng. Rehabil."},{"key":"jneacc4eabib46","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.21105\/joss.01191","article-title":"AxoPy: a Python library for implementing human-computer interface experiments","volume":"4","author":"Lyons","year":"2019","journal-title":"J. Open Source Softw."},{"key":"jneacc4eabib47","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1038\/s41592-019-0686-2","article-title":"SciPy 1.0: fundamental algorithms for scientific computing in python","volume":"17","author":"Virtanen","year":"2020","journal-title":"Nat. Methods"},{"key":"jneacc4eabib48","doi-asserted-by":"crossref","DOI":"10.1109\/EMBC46164.2021.9630318","article-title":"A network-enabled myoelectric platform for prototyping research outside of the lab","author":"Dyson","year":"2021"},{"key":"jneacc4eabib49","doi-asserted-by":"publisher","first-page":"763","DOI":"10.3390\/s21030763","article-title":"Arduino-based myoelectric control: towards longitudinal study of prosthesis use","volume":"21","author":"Wu","year":"2021","journal-title":"Sensors"},{"key":"jneacc4eabib50","first-page":"pp 59","article-title":"Frequent augmented feedback can degrade learning: evidence and interpretations","author":"Schmidt","year":"1991"},{"key":"jneacc4eabib51","doi-asserted-by":"publisher","first-page":"1499","DOI":"10.1152\/jn.00066.2015","article-title":"Delayed feedback during sensorimotor learning selectively disrupts adaptation but not strategy use","volume":"115","author":"Brudner","year":"2016","journal-title":"J. Neurophysiol."},{"key":"jneacc4eabib52","doi-asserted-by":"publisher","first-page":"2843","DOI":"10.1152\/jn.00002.2011","article-title":"A spatial explicit strategy reduces error but interferes with sensorimotor adaptation","volume":"105","author":"Benson","year":"2011","journal-title":"J. Neurophysiol."},{"key":"jneacc4eabib53","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1177\/0309364617728117","article-title":"The deka hand: a multifunction prosthetic terminal device\u2013patterns of grip usage at home","volume":"42","author":"Resnik","year":"2018","journal-title":"Prosthet. Orthot. Int."},{"key":"jneacc4eabib54","first-page":"pp 386","article-title":"Pattern recognition and direct control home use of a multi-articulating hand prosthesis","author":"Simon","year":"2019"},{"key":"jneacc4eabib55","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1109\/TNSRE.2022.3221558","article-title":"User performance with a transradial multi-articulating hand prosthesis during pattern recognition and direct control home use","volume":"31","author":"Simon","year":"2023","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"edition":"6th edn","year":"2019","author":"Schmidt","key":"jneacc4eabib56"},{"year":"1965","author":"Ellis","key":"jneacc4eabib57"},{"key":"jneacc4eabib58","first-page":"pp 94","article-title":"Transfer of abstract control skills to prosthesis use","author":"Dupan","year":"2022"},{"key":"jneacc4eabib59","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1007\/s00221-008-1394-9","article-title":"Trans-radial upper extremity amputees are capable of adapting to a novel dynamic environment","volume":"188","author":"Schabowsky","year":"2008","journal-title":"Exp. Brain Res."},{"key":"jneacc4eabib60","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1682\/JRRD.2012.06.0115","article-title":"Motor control and learning with lower-limb myoelectric control in amputees","volume":"50","author":"Alcaide-Aguirre","year":"2013","journal-title":"J. Rehabil. Res. Dev."},{"key":"jneacc4eabib61","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0170473","article-title":"Adaptation to random and systematic errors: comparison of amputee and non-amputee control interfaces with varying levels of process noise","volume":"12","author":"Johnson","year":"2017","journal-title":"PLoS One"},{"key":"jneacc4eabib62","doi-asserted-by":"publisher","first-page":"3444","DOI":"10.3390\/s21103444","article-title":"Wearable devices for biofeedback rehabilitation: a systematic review and meta-analysis to design application rules and estimate the effectiveness on balance and gait outcomes in neurological diseases","volume":"21","author":"Bowman","year":"2021","journal-title":"Sensors"}],"container-title":["Journal of Neural Engineering"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,9]],"date-time":"2023-05-09T16:27:10Z","timestamp":1683649630000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1741-2552\/acc4ea"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,9]]},"references-count":62,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,5,9]]},"published-print":{"date-parts":[[2023,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1741-2552\/acc4ea","relation":{},"ISSN":["1741-2560","1741-2552"],"issn-type":[{"type":"print","value":"1741-2560"},{"type":"electronic","value":"1741-2552"}],"subject":[],"published":{"date-parts":[[2023,5,9]]},"assertion":[{"value":"Delaying feedback during pre-device training facilitates the retention of novel myoelectric skills: a laboratory and home-based study","name":"article_title","label":"Article Title"},{"value":"Journal of Neural Engineering","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2022-05-06","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-03-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-05-09","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}