{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T13:57:21Z","timestamp":1765029441404,"version":"3.46.0"},"reference-count":57,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2021,2,11]],"date-time":"2021-02-11T00:00:00Z","timestamp":1613001600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,2,11]],"date-time":"2021-02-11T00:00:00Z","timestamp":1613001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Fondation Mutualia"},{"name":"Fonds de dotation Clinatec"},{"DOI":"10.13039\/501100001665","name":"Agence Nationale de la Recherche","doi-asserted-by":"crossref","award":["ANR-15-CE18-0006-01"],"award-info":[{"award-number":["ANR-15-CE18-0006-01"]}],"id":[{"id":"10.13039\/501100001665","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Breath Res."],"published-print":{"date-parts":[[2021,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    In the context of organ shortage for transplantation, new criteria for better organ evaluation should be investigated. Ex-vivo lung perfusion (EVLP) allows extra-corporal lung re-conditioning and evaluation, under controlled parameters of the organ reperfusion and mechanical ventilation. This work reports on the interest of exhaled gas analysis during the EVLP procedure. After a 1 h cold ischemia, the endogenous gas production by an isolated lung of nitric oxide and carbon monoxide is simultaneously monitored in real time. The exhaled gas is analysed with two very sensitive and selective laser spectrometers developed upon the technique of optical-feedback cavity-enhanced absorption spectroscopy. Exhaled gas concentration measured for an ex-vivo lung is compared to the corresponding production by the whole living pig, measured before euthanasia. On-line measurements of the fraction of nitric oxide in exhaled gas (F\n                    <jats:sub>E<\/jats:sub>\n                    NO) in isolated lungs are reported here for the first time, allowing to resolve the respiratory cycles. In this study, performed on 9 animals, F\n                    <jats:sub>E<\/jats:sub>\n                    NO by isolated lungs range from 3.3 to 10.6 ppb with a median value of 4.4 ppb. Pairing ex-vivo lung and pig measurements allows to demonstrate a systematic increase of F\n                    <jats:sub>E<\/jats:sub>\n                    NO in the ex-vivo lung as compared to the living animal, by a factor of 3 \u00b1 1.2. Measurements of the fraction of carbon monoxide in exhaled gas (F\n                    <jats:sub>E<\/jats:sub>\n                    CO) confirm levels recorded during previous studies driven to evaluate F\n                    <jats:sub>E<\/jats:sub>\n                    CO as a potential marker of ischemia reperfusion injuries. F\n                    <jats:sub>E<\/jats:sub>\n                    CO production by ex-vivo lungs ranges from 0.31 to 2.3 ppm with a median value of 0.8 ppm. As expected, these F\n                    <jats:sub>E<\/jats:sub>\n                    CO values are lower than the production by the corresponding whole pig body, by a factor of 6.9 \u00b1 2.7.\n                  <\/jats:p>","DOI":"10.1088\/1752-7163\/abde95","type":"journal-article","created":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T18:08:05Z","timestamp":1611252485000},"page":"027103","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Monitoring of endogenous nitric oxide exhaled by pig lungs during ex-vivo lung perfusion"],"prefix":"10.1088","volume":"15","author":[{"given":"Thibaut","family":"Chollier","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucile","family":"Richard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6874-8304","authenticated-orcid":false,"given":"Daniele","family":"Romanini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ang\u00e9lique","family":"Brouta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Luc","family":"Martin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C\u00e9cile","family":"Moro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5579-7665","authenticated-orcid":false,"given":"Rapha\u00ebl","family":"Briot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2114-9563","authenticated-orcid":false,"given":"Ir\u00e8ne","family":"Ventrillard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2021,2,11]]},"reference":[{"key":"jbrabde95bib1","first-page":"87","type":"journal-article","article-title":"Challenges of organ shortage for transplantation: solutions and opportunities","volume":"5","author":"Saidi","year":"2014","journal-title":"Int. J. Organ Transplant. Med."},{"key":"jbrabde95bib2","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1097\/MOT.0000000000000312","type":"journal-article","article-title":"Basic considerations in organ perfusion physiology","volume":"21","author":"Zimmerman","year":"2016","journal-title":"Curr. Opin. Organ Transplant."},{"key":"jbrabde95bib3","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1111\/tri.13441","type":"journal-article","article-title":"The future of organ perfusion and re-conditioning","volume":"32","author":"Weissenbacher","year":"2019","journal-title":"Transpl. Int."},{"key":"jbrabde95bib4","doi-asserted-by":"publisher","first-page":"631","DOI":"10.3389\/fimmu.2020.00631","type":"journal-article","article-title":"Transplanting marginal organs in the era of modern machine perfusion and advanced organ monitoring","volume":"11","author":"Resch","year":"2020","journal-title":"Front. Immunol."},{"key":"jbrabde95bib5","type":"other"},{"key":"jbrabde95bib6","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1016\/S0140-6736(00)04195-7","type":"journal-article","article-title":"Transplantation of lungs from non-heart-beating donor","volume":"356","author":"Steen","year":"2001","journal-title":"Lancet"},{"key":"jbrabde95bib7","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1056\/NEJMoa1014597","type":"journal-article","article-title":"Normothermic ex vivo lung perfusion in clinical lung transplantation","volume":"364","author":"Cypel","year":"2011","journal-title":"New Engl. J. Med."},{"key":"jbrabde95bib8","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1093\/ejcts\/ezu245","type":"journal-article","article-title":"Lung transplantation from initially rejected donors after ex vivo lung reconditioning: the French experience","volume":"46","author":"Sage","year":"2014","journal-title":"Eur. J. Cardio-thorac. Surg."},{"key":"jbrabde95bib9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13019-019-0948-1","type":"journal-article","article-title":"Ten year follow-up of lung transplantations using initially rejected donor lungs after reconditioning using ex vivo lung perfusion","volume":"14","author":"Ghaidan","year":"2019","journal-title":"J. Cardiothorac. Surg."},{"key":"jbrabde95bib10","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.accpm.2015.09.006","type":"journal-article","article-title":"Ex vivo lung graft perfusion","volume":"35","author":"Briot","year":"2016","journal-title":"Anaesth. Crit. Care Pain Med."},{"key":"jbrabde95bib11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3310\/hta20850","type":"journal-article","article-title":"An observational study of donor ex vivo lung perfusion in UK lung transplantation: DEVELOP-UK","volume":"20","author":"Fisher","year":"2016","journal-title":"Health Technol. Assess."},{"key":"jbrabde95bib12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12913-019-4154-6","type":"journal-article","article-title":"Incorporating ex-vivo lung perfusion into the UK adult lung transplant service: an economic evaluation and decision analytic model","volume":"19","author":"McMeekin","year":"2019","journal-title":"BMC Health Serv. Res."},{"key":"jbrabde95bib13","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1111\/j.1432-2277.2009.01033.x","type":"journal-article","article-title":"The number of lung transplants can be safely doubled using extended criteria donors; a single-center review","volume":"23","author":"Meers","year":"2010","journal-title":"Transpl. Int."},{"key":"jbrabde95bib14","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1111\/tri.12317","type":"journal-article","article-title":"Ex-vivo lung perfusion","volume":"28","author":"Van Raemdonck","year":"2015","journal-title":"Transpl. Int."},{"key":"jbrabde95bib15","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7163\/aa7a73","type":"journal-article","article-title":"Exhaled carbon monoxide is correlated with ischemia reperfusion injuries during ex vivo lung perfusion in pigs","volume":"11","author":"Maignan","year":"2017","journal-title":"J. Breath Res."},{"article-title":"Monitorage de l\u2019inflammation pulmonaire par le monoxyde de carbone endog\u00e8ne exhal\u00e9 dans un mod\u00e8le de poumons humains: application lors d\u2019optimisation de greffons en perfusion pulmonaire Ex-Vivo avant transplantation pulmonaire \u00c9tude BreathDiag-COe","year":"2020","author":"Brenckmann","key":"jbrabde95bib16","type":"other"},{"key":"jbrabde95bib17","doi-asserted-by":"publisher","first-page":"1861","DOI":"10.1126\/science.1470903","type":"journal-article","article-title":"The molecule of the year","volume":"258","author":"Koshland","year":"1992","journal-title":"Science"},{"key":"jbrabde95bib18","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/7\/1\/017118","type":"journal-article","article-title":"Exhaled nitric oxide as biomarker of acute lung injury: an unfulfilled promise?","volume":"7","author":"Boshier","year":"2013","journal-title":"J. Breath Res."},{"key":"jbrabde95bib19","doi-asserted-by":"publisher","first-page":"1693","DOI":"10.1164\/ajrccm.163.7.2009041","type":"journal-article","article-title":"Exhaled markers of pulmonary disease","volume":"163","author":"Kharitonov","year":"2001","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"jbrabde95bib20","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/5\/2\/024001","type":"journal-article","article-title":"Non-invasive assessment of exhaled biomarkers in lung transplantation","volume":"5","author":"Yates","year":"2011","journal-title":"J. Breath Res."},{"key":"jbrabde95bib21","doi-asserted-by":"publisher","first-page":"331","DOI":"10.2147\/JAA.S190489","type":"journal-article","article-title":"Clinical utility of the exhaled nitric oxide (NO) measurement with portable devices in the management of allergic airway inflammation and asthma","volume":"12","author":"Duong-Quy","year":"2019","journal-title":"J. Asthma Allergy"},{"key":"jbrabde95bib22","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1152\/physrev.00034.2003","type":"journal-article","article-title":"Nitric oxide in health and disease of the nervous system","volume":"84","author":"Ricciardolo","year":"2003","journal-title":"Physiol. Rev."},{"key":"jbrabde95bib23","doi-asserted-by":"publisher","first-page":"1997","DOI":"10.3390\/s18071997","type":"journal-article","article-title":"Nitric oxide analysis down to ppt levels by optical-feedback cavity-enhanced absorption spectroscopy","volume":"18","author":"Richard","year":"2018","journal-title":"Sensors"},{"key":"jbrabde95bib24","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.19.4.047001","type":"journal-article","article-title":"Real-time measurements of endogenous carbon monoxide production in isolated pig lungs","volume":"19","author":"Maignan","year":"2014","journal-title":"J. Biomed. Opt."},{"key":"jbrabde95bib25","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1164\/ajrccm.155.1.9001322","type":"journal-article","article-title":"Marked flow-dependence of exhaled nitric oxide using a new technique to exclude nasal nitric oxide","volume":"155","author":"Silkoff","year":"1997","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"jbrabde95bib26","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1046\/j.1365-201X.1997.00101.x","type":"journal-article","article-title":"Nitric oxide from the human respiratory tract efficiently quantified by standardized single breath measurements","volume":"159","author":"H\u00f6gman","year":"1997","journal-title":"Acta Physiol. Scand."},{"key":"jbrabde95bib27","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1164\/rccm.200406-710ST","type":"journal-article","article-title":"ATS\/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005","volume":"171","author":"Measurement","year":"2005","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"jbrabde95bib28","doi-asserted-by":"publisher","first-page":"8230","DOI":"10.3390\/s91008230","type":"journal-article","article-title":"Breath analysis using laser spectroscopic techniques: breath biomarkers, spectral fingerprints, and detection limits","volume":"9","author":"Wang","year":"2009","journal-title":"Sensors"},{"key":"jbrabde95bib29","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1007\/s00340-018-7030-x","type":"journal-article","article-title":"Laser spectroscopy for breath analysis: towards clinical implementation","volume":"124","author":"Henderson","year":"2018","journal-title":"Appl. Phys. B"},{"key":"jbrabde95bib30","doi-asserted-by":"publisher","first-page":"1027","DOI":"10.1007\/s00340-005-1828-z","type":"journal-article","article-title":"Fast, low-noise, mode-by-mode, cavity-enhanced absorption spectroscopy by diode-laser self-locking","volume":"80","author":"Morville","year":"2005","journal-title":"Appl. Phys. B"},{"key":"jbrabde95bib31","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.5194\/amt-10-1803-2017","type":"journal-article","article-title":"Comparison of optical-feedback cavity-enhanced absorption spectroscopy and gas chromatography for ground-based and airborne measurements of atmospheric CO concentration","volume":"10","author":"Ventrillard","year":"2017","journal-title":"Atmos. Meas. Tech. Discuss."},{"key":"jbrabde95bib32","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1080\/10256010903172715","type":"journal-article","article-title":"Development and airborne operation of a compact water isotope ratio infrared spectrometer","volume":"45","author":"Iannone","year":"2009","journal-title":"Isot. Environ. Health Stud."},{"key":"jbrabde95bib33","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1007\/s00340-006-2356-1","type":"journal-article","article-title":"A water isotope (2H, 17O, and 18O) spectrometer based on optical feedback cavity-enhanced absorption for in situ airborne applications","volume":"85","author":"Kerstel","year":"2006","journal-title":"Appl. Phys. B"},{"key":"jbrabde95bib34","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1152\/jappl.1995.78.1.59","type":"journal-article","article-title":"Exhaled nitric oxide in isolated pig lungs","volume":"78","author":"Cremona","year":"1995","journal-title":"J. Appl. Physiol."},{"key":"jbrabde95bib35","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1111\/tri.12486","type":"journal-article","article-title":"Extracorporeal CO2 removal as bridge to lung transplantation in life-threatening hypercapnia","volume":"28","author":"Schellongowski","year":"2015","journal-title":"Transpl. Int."},{"key":"jbrabde95bib36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-019-48789-8","type":"journal-article","article-title":"High inhaled oxygen concentration quadruples exhaled CO in healthy volunteers monitored by a highly sensitive laser spectrometer","volume":"9","author":"Brenckmann","year":"2019","journal-title":"Sci. Rep."},{"key":"jbrabde95bib37","doi-asserted-by":"publisher","DOI":"10.1117\/1.3269677","type":"journal-article","article-title":"Multispecies breath analysis faster than a single respiratory cycle by optical-feedback cavity-enhanced absorption spectroscopy","volume":"14","author":"Ventrillard-Courtillot","year":"2009","journal-title":"J. Biomed. Opt."},{"key":"jbrabde95bib38","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1007\/s00340-017-6750-7","type":"journal-article","article-title":"Part per trillion nitric oxide measurement by optical feedback cavity-enhanced absorption spectroscopy in the mid-infrared","volume":"123","author":"Ventrillard","year":"2017","journal-title":"Appl. Phys. B"},{"key":"jbrabde95bib39","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/7\/1\/017104","type":"journal-article","article-title":"Methods of NO detection in exhaled breath","volume":"7","author":"Cristescu","year":"2013","journal-title":"J. Breath Res."},{"key":"jbrabde95bib40","doi-asserted-by":"publisher","first-page":"9609","DOI":"10.1021\/es501896w","type":"journal-article","article-title":"A measurement of total reactive nitrogen, NOy, together with NO2, NO, and O3 via cavity ring-down spectroscopy","volume":"48","author":"Wild","year":"2014","journal-title":"Environ. Sci. Technol"},{"key":"jbrabde95bib41","doi-asserted-by":"crossref","first-page":"2425","DOI":"10.5194\/amt-13-2425-2020","type":"journal-article","article-title":"Single-photon laser-induced fluorescence detection of nitric oxide at sub-parts per trillion mixing ratios","volume":"13","author":"Rollins","year":"2020","journal-title":"Atmos. Meas. Tech. Discuss."},{"key":"jbrabde95bib42","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/5\/3\/037108","type":"journal-article","article-title":"Clinical study of multiple breath biomarkers of asthma and COPD (NO, CO(2), CO and N(2)O) by infrared laser spectroscopy","volume":"5","author":"Shorter","year":"2011","journal-title":"J. Breath Res."},{"key":"jbrabde95bib43","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.17.1.017003","type":"journal-article","article-title":"Exhaled nitric oxide monitoring by quantum cascade laser: comparison with chemiluminescent and electrochemical sensors","volume":"17","author":"Mandon","year":"2012","journal-title":"J. Biomed. Opt."},{"key":"jbrabde95bib44","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1073\/pnas.98.1.355","type":"journal-article","article-title":"The biological lifetime of nitric oxide: implications for the perivascular dynamics of NO and O2","volume":"98","author":"Thomas","year":"2001","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"jbrabde95bib45","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1152\/jappl.1998.85.2.653","type":"journal-article","article-title":"A two-compartment model of pulmonary nitric oxide exchange dynamics","volume":"85","author":"Tsoukias","year":"1998","journal-title":"J. Appl. Physiol."},{"key":"jbrabde95bib46","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1164\/ajrccm.163.7.2010171","type":"journal-article","article-title":"Between alveolar and bronchial inflammation","volume":"163","author":"Lehtim\u00e4ki","year":"2001","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"jbrabde95bib47","doi-asserted-by":"publisher","first-page":"1681","DOI":"10.1016\/S0140-6736(05)64281-X","type":"journal-article","article-title":"Exhaled nitric oxide during lung transplantation","volume":"350","author":"Marczin","year":"1997","journal-title":"Lancet"},{"key":"jbrabde95bib48","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1136\/thx.52.8.736","type":"journal-article","article-title":"Exhaled NO during graded changes in inhaled oxygen in man","volume":"52","author":"Schmetterer","year":"1997","journal-title":"Thorax"},{"key":"jbrabde95bib49","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1097\/00000542-199504000-00021","type":"journal-article","article-title":"Positive end-expiratory pressure ventilation elicits increases in endogenously formed nitric oxide as detected in air exhaled by rabbits","volume":"82","author":"Persson","year":"1995","journal-title":"Anesthesiology"},{"key":"jbrabde95bib50","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1152\/ajpgi.1999.276.2.G315","type":"journal-article","article-title":"I. Physiological chemistry of nitric oxide and its metabolites: implications in inflammation","volume":"276","author":"Grisham","year":"1999","journal-title":"Am. J. Physiol. Gastrointest. Liver Physiol."},{"key":"jbrabde95bib51","doi-asserted-by":"publisher","first-page":"6509","DOI":"10.1021\/jp051534v","type":"journal-article","article-title":"Formation of nitric acid in the gas-phase HO2 + NO reaction: effects of temperature and water vapor","volume":"109","author":"Butkovskaya","year":"2005","journal-title":"J. Phys. Chem. A"},{"key":"jbrabde95bib52","doi-asserted-by":"publisher","first-page":"11327","DOI":"10.1021\/jp811428p","type":"journal-article","article-title":"Water vapor effect on the HNO 3 yield in the HO2 + NO reaction: experimental and theoretical evidence","volume":"113","author":"Butkovskaya","year":"2009","journal-title":"J. Phys. Chem. A"},{"key":"jbrabde95bib53","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1124\/pr.120.019240","type":"journal-article","article-title":"The noncanonical pathway for in vivo nitric oxide generation: the nitrate-nitrite-nitric oxide pathway","volume":"72","author":"Kapil","year":"2020","journal-title":"Pharmacol. Rev."},{"key":"jbrabde95bib54","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7163\/aafc91","type":"journal-article","article-title":"Fitting of single-exhalation profiles using a pulmonary gas exchange model\u2014application to carbon monoxide","volume":"13","author":"Ghorbani","year":"2019","journal-title":"J. Breath Res."},{"key":"jbrabde95bib55","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00340-015-6294-7","type":"journal-article","article-title":"Quantum cascade laser-based sensors for the detection of exhaled carbon monoxide","volume":"122","author":"Pakmanesh","year":"2016","journal-title":"Appl. Phys. B"},{"key":"jbrabde95bib56","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/6\/4\/047101","type":"journal-article","article-title":"Laser spectroscopy review of exhaled nitric oxide in chronic obstructive pulmonary disease","volume":"6","author":"Gelb","year":"2012","journal-title":"J. Breath Res."},{"key":"jbrabde95bib57","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1016\/0034-5687(67)90068-0","type":"journal-article","article-title":"Elimination of inert gas by the lung","volume":"3","author":"Farhi","year":"1967","journal-title":"Respir. Physiol."}],"container-title":["Journal of Breath Research"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T13:56:18Z","timestamp":1765029378000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/abde95"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,11]]},"references-count":57,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2021,2,11]]},"published-print":{"date-parts":[[2021,4,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1752-7163\/abde95","relation":{},"ISSN":["1752-7155","1752-7163"],"issn-type":[{"type":"print","value":"1752-7155"},{"type":"electronic","value":"1752-7163"}],"subject":[],"published":{"date-parts":[[2021,2,11]]},"assertion":[{"value":"Monitoring of endogenous nitric oxide exhaled by pig lungs during ex-vivo lung perfusion","name":"article_title","label":"Article Title"},{"value":"Journal of Breath Research","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-09-09","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-01-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-02-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}