{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T02:16:16Z","timestamp":1785896176890,"version":"3.56.0"},"reference-count":41,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T00:00:00Z","timestamp":1703635200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T00:00:00Z","timestamp":1703635200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"crossref","award":["13GW0428C"],"award-info":[{"award-number":["13GW0428C"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Breath Res."],"published-print":{"date-parts":[[2024,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Exhaled breath analysis is evolving into an increasingly important non-invasive diagnostic tool. Volatile organic compounds (VOCs) in breath contain information about health status and are promising biomarkers for several diseases, including respiratory infections caused by bacteria. To monitor the composition of VOCs in breath or the emission of VOCs from bacteria, sensitive analytical techniques are required. Next to mass spectrometry, ion mobility spectrometry (IMS) is considered a promising analytical tool for detecting gaseous analytes in the parts per billion by volume to parts per trillion by volume range. This work presents a new, dual coupling of thermal desorption gas chromatography to a quadrupole mass spectrometer (MS) and an IMS by operating a simple splitter. Nearly identical retention times can be reached in the range of up to 30 min with slight deviations of 0.06 min\u20130.24 min. This enables the identification of unknown compounds in the IMS chromatogram using unambiguous mass spectral identification, as there are still no commercially available databases for IMS. It is also possible to discriminate one of the detectors using the splitter to improve detection limits. Using a test liquid mixture of seven ketones, namely 2-butanone, 2-pentanone, 2-hexanone, 2-heptanone, 2-octanone, 2-nonanone, and 2-decanone with a concentration of 0.01 g l<jats:sup>\u22121<\/jats:sup> reproducibilities ranging from 3.0% to 7.6% for MS and 2.2%\u20135.3%, for IMS were obtained, respectively. In order to test the system optimized here for the field of breath analysis, characteristic VOCs such as ethanol, isoprene, acetone, 2-propanol, and 1-propanol were successfully identified in exhaled air using the dual detector system due to the match of the corresponding IMS, and MS spectra. The presented results may be considered to be a starting point for the greater use of IMS in combination with MS within the medical field.<\/jats:p>","DOI":"10.1088\/1752-7163\/ad1615","type":"journal-article","created":{"date-parts":[[2023,12,15]],"date-time":"2023-12-15T22:25:27Z","timestamp":1702679127000},"page":"016009","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":10,"title":["A novel coupling technique based on thermal desorption gas chromatography with mass spectrometry and ion mobility spectrometry for breath analysis"],"prefix":"10.1088","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9188-4646","authenticated-orcid":true,"given":"Hannah","family":"Schanzmann","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9631-364X","authenticated-orcid":true,"given":"Veronika","family":"Ruzsanyi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9439-7317","authenticated-orcid":false,"given":"Parviz","family":"Ahmad-Nejad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0347-2989","authenticated-orcid":false,"given":"Ursula","family":"Telgheder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9367-524X","authenticated-orcid":false,"given":"Stefanie","family":"Sielemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2023,12,27]]},"reference":[{"key":"jbrad1615bib1","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1111\/j.1600-0668.1995.00004.x","article-title":"Review and a limited comparison of methods for measuring total volatile organic compounds in indoor air","volume":"5","author":"Hodgson","year":"1995","journal-title":"Indoor Air"},{"key":"jbrad1615bib2","doi-asserted-by":"publisher","first-page":"5457","DOI":"10.3390\/molecules26185457","article-title":"Non-targeted screening approaches for profiling of volatile organic compounds based on gas chromatography-ion mobility spectroscopy (GC-IMS) and machine learning","volume":"26","author":"Capitain","year":"2021","journal-title":"Molecules"},{"key":"jbrad1615bib3","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1038\/092549a0","article-title":"Rays of positive electricity and their application to chemical analysis","volume":"92","author":"R","year":"1914","journal-title":"Nature"},{"key":"jbrad1615bib4","doi-asserted-by":"publisher","first-page":"5678","DOI":"10.1021\/ac8013065","article-title":"A brief history of mass spectrometry","volume":"80","author":"Griffiths","year":"2008","journal-title":"Anal. Chem."},{"key":"jbrad1615bib5","doi-asserted-by":"publisher","first-page":"338A","DOI":"10.1366\/0003702991947847","article-title":"Ion mobility spectrometry: arriving on site and moving beyond a low profile","volume":"53","author":"Baumbach","year":"1999","journal-title":"Appl. Spectrosc."},{"key":"jbrad1615bib6","author":"Eiceman","year":"2005","edition":"3rd edn"},{"key":"jbrad1615bib7","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1080\/05704920600663469","article-title":"Ion mobility spectrometry: principles and applications","volume":"41","author":"Borsdorf","year":"2006","journal-title":"Appl. Spectrosc. Rev."},{"key":"jbrad1615bib8","doi-asserted-by":"publisher","first-page":"2706","DOI":"10.3390\/molecules24152706","article-title":"Ion mobility spectrometry in food analysis: principles, current applications and future trends","volume":"24","author":"Hern\u00e1ndez-Mesa","year":"2019","journal-title":"Molecules"},{"key":"jbrad1615bib9","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2022.340039","article-title":"Insights of ion mobility spectrometry and its application on food safety and authenticity: a review","volume":"1222","author":"Te Brinke","year":"2022","journal-title":"Anal. Chim. Acta"},{"key":"jbrad1615bib10","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1039\/C4AN01100G","article-title":"Review on ion mobility spectrometry. Part 1: current instrumentation","volume":"140","author":"Cumeras","year":"2015","journal-title":"Analyst"},{"key":"jbrad1615bib11","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1006\/abio.1997.2069","article-title":"Method for the collection and assay of volatile organic compounds in breath","volume":"247","author":"Phillips","year":"1997","journal-title":"Anal. Biochem."},{"key":"jbrad1615bib12","first-page":"88","article-title":"Determination of Pentane, Isoprene and Acetone Using HSCC-UV-IMS","volume":"4","author":"Xie","year":"2001","journal-title":"Int. J. Ion Mobility Spectrom."},{"key":"jbrad1615bib13","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.chroma.2005.01.055","article-title":"Detection of human metabolites using multi-capillary columns coupled to ion mobility spectrometers","volume":"1084","author":"Ruzsanyi","year":"2005","journal-title":"J. Chromatogr. A"},{"key":"jbrad1615bib14","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.jchromb.2006.01.017","article-title":"Analysis of expired air of fasting male monks at Mount Athos","volume":"832","author":"Statheropoulos","year":"2006","journal-title":"J. Chromatogr. B"},{"key":"jbrad1615bib15","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/3\/3\/034001","article-title":"Ion mobility spectrometry coupled with multi-capillary columns for metabolic profiling of human breath","volume":"3","author":"Baumbach","year":"2009","journal-title":"J. Breath Res."},{"key":"jbrad1615bib16","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/3\/3\/036004","article-title":"Breath analysis-performance and potential of ion mobility spectrometry","volume":"3","author":"Vautz","year":"2009","journal-title":"J. Breath Res."},{"key":"jbrad1615bib17","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1093\/bja\/aep312","article-title":"Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry","volume":"103","author":"Perl","year":"2009","journal-title":"Br. J. Anaesth."},{"key":"jbrad1615bib18","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1152\/japplphysiol.00658.2009","article-title":"Analyses of mouse breath with ion mobility spectrometry: a feasibility study","volume":"108","author":"Vautz","year":"2010","journal-title":"J. Appl. Physiol."},{"key":"jbrad1615bib19","doi-asserted-by":"publisher","first-page":"2115","DOI":"10.1378\/chest.123.6.2115","article-title":"Detection of lung cancer with volatile markers in the breath","volume":"123","author":"Phillips","year":"2003","journal-title":"Chest"},{"key":"jbrad1615bib20","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.jchromb.2018.01.013","article-title":"Monitoring of selected skin- and breath-borne volatile organic compounds emitted from the human body using gas chromatography ion mobility spectrometry (GC-IMS)","volume":"1076","author":"Mochalski","year":"2018","journal-title":"J. Chromatogr. B"},{"key":"jbrad1615bib21","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0114555","article-title":"Exhaled breath analysis for lung cancer detection using ion mobility spectrometry","volume":"9","author":"Handa","year":"2014","journal-title":"PLoS One"},{"key":"jbrad1615bib22","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1136\/thx.2008.099465","article-title":"Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study","volume":"64","author":"Westhoff","year":"2009","journal-title":"Thorax"},{"key":"jbrad1615bib23","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/10\/2\/026004","article-title":"Measurement of exhaled volatile organic compounds from patients with chronic obstructive pulmonary disease (COPD) using closed gas loop GC-IMS and GC-APCI-MS","volume":"10","author":"Allers","year":"2016","journal-title":"J. Breath Res."},{"key":"jbrad1615bib24","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/6\/3\/036007","article-title":"Data interpretation in breath biomarker research: pitfalls and directions","volume":"6","author":"Miekisch","year":"2012","journal-title":"J. Breath Res."},{"key":"jbrad1615bib25","doi-asserted-by":"publisher","DOI":"10.1016\/j.eclinm.2020.100609","article-title":"Diagnosis of COVID-19 by analysis of breath with gas chromatography-ion mobility spectrometry\u2014a feasibility study","volume":"29","author":"Ruszkiewicz","year":"2020","journal-title":"EClinicalMedicine"},{"key":"jbrad1615bib26","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1016\/S0584-8547(02)00110-6","article-title":"Ion mobility spectrometer for online monitoring of trace compounds","volume":"57","author":"Li","year":"2002","journal-title":"Spectrochim. Acta B"},{"key":"jbrad1615bib27","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1039\/C4AN01101E","article-title":"Review on ion mobility spectrometry. Part 2: hyphenated methods and effects of experimental parameters","volume":"140","author":"Cumeras","year":"2015","journal-title":"Analyst"},{"key":"jbrad1615bib28","doi-asserted-by":"publisher","DOI":"10.1016\/j.talanta.2019.120594","article-title":"Analysis of e-liquids for electronic cigarettes using GC-IMS\/MS with headspace sampling","volume":"209","author":"Budzy\u0144ska","year":"2020","journal-title":"Talanta"},{"key":"jbrad1615bib29","doi-asserted-by":"publisher","DOI":"10.1016\/j.talanta.2021.122318","article-title":"Strategy for the identification of flavor compounds in e-liquids by correlating the analysis of GCxIMS and GC-MS","volume":"230","author":"Augustini","year":"2021","journal-title":"Talanta"},{"key":"jbrad1615bib30","doi-asserted-by":"publisher","first-page":"7085","DOI":"10.1007\/s00216-020-02842-y","article-title":"Gas-phase volatilomic approaches for quality control of brewing hops based on simultaneous GC-MS-IMS and machine learning","volume":"412","author":"Brendel","year":"2020","journal-title":"Anal. Bioanal. Chem."},{"key":"jbrad1615bib31","doi-asserted-by":"publisher","first-page":"491","DOI":"10.3389\/fmicb.2018.00491","article-title":"Direct growth of bacteria in headspace vials allows for screening of volatiles by gas chromatography mass spectrometry","volume":"9","author":"Timm","year":"2018","journal-title":"Front. Microbiol."},{"key":"jbrad1615bib32","doi-asserted-by":"publisher","first-page":"9091","DOI":"10.1007\/s00253-019-10181-x","article-title":"GC-IMS headspace analyses allow early recognition of bacterial growth and rapid pathogen differentiation in standard blood cultures","volume":"103","author":"Drees","year":"2019","journal-title":"Appl. Microbiol. Biotechnol."},{"key":"jbrad1615bib33","doi-asserted-by":"publisher","DOI":"10.1016\/j.mex.2021.101386","article-title":"Cheap and easy human breath collection system for trace volatile organic compounds screening using thermal desorption\u2014gas chromatography mass spectrometry","volume":"8","author":"Vicent-Claramunt","year":"2021","journal-title":"MethodsX"},{"key":"jbrad1615bib34","doi-asserted-by":"publisher","first-page":"1789","DOI":"10.3390\/molecules26061789","article-title":"Needle trap device-GC-MS for characterization of lung diseases based on breath VOC profiles","volume":"26","author":"Monedeiro","year":"2021","journal-title":"Molecules"},{"key":"jbrad1615bib35","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1016\/S0021-9673(01)80947-X","article-title":"A generalization of the retention index system including linear temperature programmed gas\u2014liquid partition chromatography","volume":"11","author":"van den Dool","year":"1963","journal-title":"J. Chromatogr. A"},{"key":"jbrad1615bib36","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1016\/0021-9673(95)00213-7","article-title":"Breakthrough volume of monoterpenes on Tenax TA: influence of temperature and concentration for \u03b1-pinene","volume":"704","author":"Simon","year":"1995","journal-title":"J. Chromatogr. A"},{"key":"jbrad1615bib37","doi-asserted-by":"publisher","first-page":"2609","DOI":"10.1007\/s00216-008-2181-y","article-title":"Micro-plasma: a novel ionisation source for ion mobility spectrometry","volume":"391","author":"Vautz","year":"2008","journal-title":"Anal. Bioanal. Chem."},{"key":"jbrad1615bib38","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1088\/0967-3334\/27\/4\/001","article-title":"A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS","volume":"27","author":"Turner","year":"2006","journal-title":"Physiol. Meas."},{"key":"jbrad1615bib39","doi-asserted-by":"publisher","first-page":"12","DOI":"10.3390\/diagnostics8010012","article-title":"Sensing technologies for detection of acetone in human breath for diabetes diagnosis and monitoring","volume":"8","author":"Saasa","year":"2018","journal-title":"Diagnostics"},{"key":"jbrad1615bib40","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1038\/s42003-023-05384-y","article-title":"Origin of breath isoprene in humans is revealed via multi-omic investigations","volume":"6","author":"Sukul","year":"2023","journal-title":"Commun. Biol."},{"key":"jbrad1615bib41","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/S0304-4165(03)00051-5","article-title":"On the mammalian acetone metabolism: from chemistry to clinical implications","volume":"1621","author":"Kalapos","year":"2003","journal-title":"Biochim. Biophys. Acta"}],"container-title":["Journal of Breath Research"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T10:54:04Z","timestamp":1703674444000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad1615"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,27]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12,27]]},"published-print":{"date-parts":[[2024,1,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1752-7163\/ad1615","relation":{},"ISSN":["1752-7155","1752-7163"],"issn-type":[{"value":"1752-7155","type":"print"},{"value":"1752-7163","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,27]]},"assertion":[{"value":"A novel coupling technique based on thermal desorption gas chromatography with mass spectrometry and ion mobility spectrometry for breath analysis","name":"article_title","label":"Article Title"},{"value":"Journal of Breath Research","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2023-07-07","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-12-15","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-12-27","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}