{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,2]],"date-time":"2025-04-02T07:47:46Z","timestamp":1743580066307,"version":"3.37.3"},"reference-count":39,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T00:00:00Z","timestamp":1732752000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T00:00:00Z","timestamp":1732752000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100012542","name":"Sichuan Provincial Science and Technology Support Program","doi-asserted-by":"crossref","award":["2023YFS0136"],"award-info":[{"award-number":["2023YFS0136"]}],"id":[{"id":"10.13039\/100012542","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Breath Res."],"published-print":{"date-parts":[[2025,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Several clinical studies have reported promising correlations between propofol concentration in exhaled breath (Ce-pro) and the bispectral index (BIS) in patients, suggesting the potential of exhaled propofol measurement as a non-invasive method for adjusting anesthesia depth. However, these studies are still in the validation phase of instrument effectiveness, often limited by small sample sizes or inappropriate instrument selection, and thus lack convincing results regarding these correlations. In this study, one hundred patients aged 18\u201365, undergoing elective thyroid surgery under general anesthesia were included. The vacuum ultraviolet photoionization and time-of-flight mass spectrometry was employed to monitor Ce-pro at 20 s intervals, alongside continuous BIS measurement. The association between Ce-pro and BIS was analyzed using linear mixed-effects models, with marginal <jats:italic>R<\/jats:italic>\n                  <jats:sup>2<\/jats:sup> used to assess the correlation. The threshold of Ce-pro at awakening was also explored. Additionally, the univariate and multifactorial diagnostic model, including end-of-surgery Ce-pro, were employed to assess the accuracy of predicting delayed recovery. A weak correlation was observed between intraoperative Ce-pro and BIS (marginal <jats:italic>R<\/jats:italic>\n                  <jats:sup>2<\/jats:sup> = 0.348). Predictive models utilizing end-of-surgery Ce-pro levels showed good accuracy (area under the curve (AUC) = 0.75, 95% CI: 0.62\u20130.89, <jats:italic>P<\/jats:italic> = 0.003) in predicting delayed recovery, while the model using end-of-surgery Ce-pro combined with gender, sufentanil dosage, the time from the last administration of sufentanil to the end of surgery, and anesthesia duration demonstrated stronger predicting accuracy (AUC = 0.91, 95% CI: 0.85\u20130.98, <jats:italic>P<\/jats:italic> &lt; 0.001). This study suggests that Ce-pro alone may not reliably predict the depth of anesthesia in clinical practice, but shows promising accuracy in predicting delayed recovery from anesthesia.<\/jats:p>","DOI":"10.1088\/1752-7163\/ad9496","type":"journal-article","created":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T12:51:44Z","timestamp":1732193504000},"page":"016010","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Correlations between propofol concentration in exhaled breath and BIS in patients undergoing thyroid surgery"],"prefix":"10.1088","volume":"19","author":[{"given":"Xiaoxiao","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pan","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xing","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhongjun","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yixiang","family":"Duan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2737-8623","authenticated-orcid":true,"given":"Wensheng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,11,28]]},"reference":[{"key":"jbrad9496bib1","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1080\/00498250903056109","article-title":"Blood gas partition coefficient and pulmonary extraction ratio for propofol in goats and pigs","volume":"39","author":"Grossherr","year":"2009","journal-title":"Xenobiotica"},{"key":"jbrad9496bib2","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1093\/bja\/aep053","article-title":"Propofol concentration in exhaled air and arterial plasma in mechanically ventilated patients undergoing cardiac surgery","volume":"102","author":"Grossherr","year":"2009","journal-title":"Br. J. Anaesth."},{"key":"jbrad9496bib3","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1097\/01.anes.0000264745.63275.59","article-title":"On-line monitoring of end-tidal propofol concentration in anesthetized patients","volume":"106","author":"Takita","year":"2007","journal-title":"J. Am. Soc. Anesthesiol."},{"key":"jbrad9496bib4","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1093\/bja\/aeg271","article-title":"Real\u2010time breath monitoring of propofol and its volatile metabolites during surgery using a novel mass spectrometric technique: a feasibility study","volume":"91","author":"Harrison","year":"2003","journal-title":"Br. J. Anaesth."},{"key":"jbrad9496bib5","doi-asserted-by":"publisher","first-page":"3233","DOI":"10.1039\/c1an15356k","article-title":"On-line, real time monitoring of exhaled trace gases by SIFT-MS in the perioperative setting: a feasibility study","volume":"136","author":"Boshier","year":"2011","journal-title":"Analyst"},{"key":"jbrad9496bib6","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1093\/bja\/aep312","article-title":"Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry","volume":"103","author":"Perl","year":"2009","journal-title":"Br. J. Anaesth."},{"key":"jbrad9496bib7","doi-asserted-by":"publisher","first-page":"10803","DOI":"10.1021\/acs.chemrev.9b00005","article-title":"On-line analysis of exhaled breath: focus review","volume":"119","author":"Bruderer","year":"2019","journal-title":"Chem. Rev."},{"key":"jbrad9496bib8","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1093\/bja\/ael120","article-title":"Depth of anaesthesia monitoring: what\u2019s available, what\u2019s validated and what\u2019s next?","volume":"97","author":"Bruhn","year":"2006","journal-title":"Br. J. Anaesth."},{"key":"jbrad9496bib9","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1097\/00000542-200212000-00006","article-title":"Propofol: relation between brain concentrations, electroencephalogram, middle cerebral artery blood flow velocity, and cerebral oxygen extraction during induction of anesthesia","volume":"97","author":"Ludbrook","year":"2002","journal-title":"Anesthesiology"},{"key":"jbrad9496bib10","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1111\/aas.14043","article-title":"Online exhaled propofol monitoring in normal\u2010weight and obese surgical patients","volume":"66","author":"Braathen","year":"2022","journal-title":"Acta Anaesthesiol. Scand."},{"key":"jbrad9496bib11","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1111\/aas.12448","article-title":"Online breath analysis of propofol during anesthesia: clinical application of membrane inlet\u2010ion mobility spectrometry","volume":"59","author":"Liu","year":"2015","journal-title":"Acta Anaesthesiol. Scand."},{"key":"jbrad9496bib12","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1007\/s00216-012-5856-3","article-title":"Time course of expiratory propofol after bolus injection as measured by ion molecule reaction mass spectrometry","volume":"403","author":"Hornuss","year":"2012","journal-title":"Anal. Bioanal.Chem."},{"key":"jbrad9496bib13","doi-asserted-by":"publisher","first-page":"4179","DOI":"10.1039\/d3ay01168b","article-title":"Calibration and validation of ultraviolet time-of-flight mass spectrometry for online measurement of exhaled ciprofol","volume":"15","author":"Li","year":"2023","journal-title":"Anal. Methods"},{"key":"jbrad9496bib14","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7163\/ad1d65","article-title":"Exhaled breath is found to be better than blood samples for determining propofol concentrations in the brain tissues of rats","volume":"18","author":"Li","year":"2024","journal-title":"J. Breath Res."},{"key":"jbrad9496bib15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpba.2023.115621","article-title":"A preclinical study on online monitoring of exhaled ciprofol concentration by the ultraviolet time-of-flight spectrometer and prediction of anesthesia depth in beagles","volume":"235","author":"Li","year":"2023","journal-title":"J. Pharm. Biomed. Anal."},{"key":"jbrad9496bib16","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.jpba.2017.06.052","article-title":"Calibration and validation of a MCC\/IMS prototype for exhaled propofol online measurement","volume":"145","author":"Maurer","year":"2017","journal-title":"J. Pharm. Biomed. Anal."},{"key":"jbrad9496bib17","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1002\/bmc.835","article-title":"Human exhaled air analytics: biomarkers of diseases","volume":"21","author":"Buszewski","year":"2007","journal-title":"Biomed. Chromatogr."},{"key":"jbrad9496bib18","doi-asserted-by":"publisher","first-page":"541","DOI":"10.4103\/0976-500X.162004","article-title":"Die Int. Conf. on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH)","author":"Dagron","year":"2014"},{"key":"jbrad9496bib19","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1213\/ANE.0000000000005125","article-title":"Relationship between propofol target concentrations, bispectral index, and patient covariates during anesthesia","volume":"132","author":"Schnider","year":"2021","journal-title":"Anesth. Analg."},{"key":"jbrad9496bib20","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/j.mpaic.2013.11.007","article-title":"Tracheal intubation","volume":"15","author":"Thomas","year":"2014","journal-title":"Anaesth. Intensive Care Med."},{"key":"jbrad9496bib21","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7163\/aa795d","article-title":"Adhesion of volatile propofol to breathing circuit tubing","volume":"11","author":"Lorenz","year":"2017","journal-title":"J. Breath Res."},{"key":"jbrad9496bib22","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7163\/aa567e","article-title":"Adherence of volatile propofol to various types of plastic tubing","volume":"11","author":"Maurer","year":"2017","journal-title":"J. Breath Res."},{"key":"jbrad9496bib23","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1097\/ALN.0000000000005043","article-title":"Electroencephalographic indices for clinical endpoints during propofol anesthesia in infants: an early-phase propofol biomarker-finding study","volume":"141","author":"Yuan","year":"2024","journal-title":"Anesthesiology"},{"key":"jbrad9496bib24","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1111\/j.2041-210x.2012.00261.x","article-title":"A general and simple method for obtaining R2 from generalized linear mixed\u2010effects models","volume":"4","author":"Nakagawa","year":"2013","journal-title":"Meth. Ecol. Evol."},{"key":"jbrad9496bib25","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1213\/ANE.0000000000003511","article-title":"Repeated measures designs and analysis of longitudinal data: if at first you do not succeed-try, try again","volume":"127","author":"Schober","year":"2018","journal-title":"Anesth. Analg."},{"key":"jbrad9496bib26","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1093\/bja\/aeu193","article-title":"Gas chromatograph\u2013surface acoustic wave for quick real-time assessment of blood\/exhaled gas ratio of propofol in humans","volume":"113","author":"Chen","year":"2014","journal-title":"Br. J. Anaesth."},{"key":"jbrad9496bib27","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/3\/3\/036004","article-title":"Breath analysis\u2014performance and potential of ion mobility spectrometry","volume":"3","author":"Vautz","year":"2009","journal-title":"J. Breath Res."},{"key":"jbrad9496bib28","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1007\/s10877-022-00907-0","article-title":"Humidity and measurement of volatile propofol using MCC-IMS (EDMON)","volume":"37","author":"Teucke","year":"2023","journal-title":"J. Clin. Monit. Comput."},{"key":"jbrad9496bib29","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1002\/9783527682201.ch3","article-title":"Analytical application of single\u2010photon ionization mass spectrometry (SPI\u2010MS)","author":"Streibel","year":"2021"},{"key":"jbrad9496bib30","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1007\/BF03261928","article-title":"Fundamentals of population pharmacokinetic modelling: modelling and software","volume":"51","author":"Kiang","year":"2012","journal-title":"Clin. Pharmacokinet."},{"key":"jbrad9496bib31","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1080\/10408347.2021.1889961","article-title":"Breathomics: review of sample collection and analysis, data modeling and clinical applications","volume":"52","author":"Khoubnasabjafari","year":"2022","journal-title":"Crit. Rev. Anal. Chem."},{"key":"jbrad9496bib32","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1002\/mas.21393","article-title":"Real\u2010time monitoring of exhaled drugs by mass spectrometry","volume":"33","author":"Berchtold","year":"2014","journal-title":"Mass Spectrom. Rev."},{"key":"jbrad9496bib33","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1007\/s40262-018-0672-3","article-title":"Clinical pharmacokinetics and pharmacodynamics of propofol","volume":"57","author":"Sahinovic","year":"2018","journal-title":"Clin. Pharmacokinet."},{"key":"jbrad9496bib34","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1213\/ANE.0000000000004701","article-title":"Exhaled propofol concentrations correlate with plasma and brain tissue concentrations in rats","volume":"132","author":"M\u00fcller-Wirtz","year":"2021","journal-title":"Anesth. Analg."},{"key":"jbrad9496bib35","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1186\/s12871-021-01368-9","article-title":"Correlation of exhaled propofol with Narcotrend index and calculated propofol plasma levels in children undergoing surgery under total intravenous anesthesia-an observational study","volume":"21","author":"Heiderich","year":"2021","journal-title":"BMC Anesthesiol."},{"key":"jbrad9496bib36","doi-asserted-by":"publisher","first-page":"958","DOI":"10.1213\/ANE.0000000000004225","article-title":"Evaluating propofol concentration in blood from exhaled gas using a breathing-related partition coefficient","volume":"130","author":"Dong","year":"2020","journal-title":"Anesth. Analg."},{"key":"jbrad9496bib37","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/0952-8180(93)90003-w","article-title":"Advances in propofol pharmacokinetics and pharmacodynamics","volume":"5","author":"Shafer","year":"1993","journal-title":"J. Clin. Anesth."},{"key":"jbrad9496bib38","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1093\/bja\/aem106","article-title":"Effect site: who needs it?","volume":"98","author":"Sneyd","year":"2007","journal-title":"Br. J. Anaesth."},{"key":"jbrad9496bib39","doi-asserted-by":"publisher","first-page":"4321","DOI":"10.1097\/MS9.0000000000001103","article-title":"Delayed awakening and its associated factor following general anesthesia service, 2022: a cross-sectional study","volume":"85","author":"Bayable","year":"2023","journal-title":"Ann. Med. Surg."}],"container-title":["Journal of Breath Research"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,28]],"date-time":"2024-11-28T05:54:51Z","timestamp":1732773291000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1752-7163\/ad9496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,28]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,11,28]]},"published-print":{"date-parts":[[2025,1,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1752-7163\/ad9496","relation":{},"ISSN":["1752-7155","1752-7163"],"issn-type":[{"type":"print","value":"1752-7155"},{"type":"electronic","value":"1752-7163"}],"subject":[],"published":{"date-parts":[[2024,11,28]]},"assertion":[{"value":"Correlations between propofol concentration in exhaled breath and BIS in patients undergoing thyroid surgery","name":"article_title","label":"Article Title"},{"value":"Journal of Breath Research","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-07-23","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-11-19","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-11-28","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}