{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T11:57:34Z","timestamp":1773921454679,"version":"3.50.1"},"reference-count":43,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T00:00:00Z","timestamp":1773878400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T00:00:00Z","timestamp":1773878400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2026,4,1]]},"DOI":"10.1088\/1873-4030\/ae4e2f","type":"journal-article","created":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T07:30:35Z","timestamp":1773905435000},"page":"045006","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Mitigating failures and enhancing reliability of a canine ventricular shunt through robust multi-objective design method"],"prefix":"10.1088","volume":"147","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-4801-1362","authenticated-orcid":true,"given":"Gehendra","family":"Sharma","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryan","family":"Yingling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2209-6555","authenticated-orcid":true,"given":"NaYeon","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raheleh","family":"Miralami","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6337-485X","authenticated-orcid":true,"given":"Andy","family":"Shores","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anand Balu","family":"Nellippallil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tonya W","family":"Stone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raj K","family":"Prabhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2026,3,19]]},"reference":[{"key":"mepae4e2fbib1","first-page":"337","type":"journal-article","article-title":"Protrusion of ventriculo peritoneal shunt through the anus: report of two cases","volume":"74","author":"Adeloye","year":"1997","journal-title":"East. Afr. Med. J."},{"key":"mepae4e2fbib2","first-page":"p V009T09A017","type":"book","volume":"vol 83983","author":"Beemaraj","year":"2020"},{"key":"mepae4e2fbib3","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1159\/000028659","type":"journal-article","article-title":"Effects of proteins, blood cells and glucose on the viscosity of cerebrospinal fluid","volume":"28","author":"Bloomfield","year":"1998","journal-title":"Pediatr. Neurosurg."},{"key":"mepae4e2fbib4","doi-asserted-by":"publisher","first-page":"191","DOI":"10.3171\/2011.11.PEDS11255","type":"journal-article","article-title":"Flow characteristics of cerebrospinal fluid shunt tubing","volume":"9","author":"Cheatle","year":"2012","journal-title":"J. Neurosurg. Pediatr."},{"key":"mepae4e2fbib5","doi-asserted-by":"publisher","DOI":"10.1115\/1.2826915","type":"other","article-title":"A procedure for robust design: minimizing variations caused by noise factors and control factors","author":"Chen","year":"1996"},{"key":"mepae4e2fbib6","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1080\/03052159908941389","type":"journal-article","article-title":"Satisfying ranged sets of design requirements using design capability indices as metrics","volume":"31","author":"Chen","year":"1999","journal-title":"Eng. Optim."},{"key":"mepae4e2fbib7","first-page":"334","author":"Czosnyka","year":"1998","type":"book"},{"key":"mepae4e2fbib8","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.1001\/archsurg.1929.01140130837055","type":"journal-article","article-title":"Treatment of hydrocephalus: historical review and description of a new method","volume":"18","author":"Davidoff","year":"1929","journal-title":"Arch. Surg."},{"key":"mepae4e2fbib9","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1097\/00000542-195411000-00010","type":"journal-article","article-title":"Densities of cerebrospinal fluid of human beings","volume":"15","author":"Davis","year":"1954","journal-title":"J. Am. Soc. Anesthesiol."},{"key":"mepae4e2fbib10","author":"De Lahunta","year":"2014","journal-title":"Veterinary Neuroanatomy and Clinical Neurology-E-Book","type":"journal-article"},{"key":"mepae4e2fbib11","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1097\/00006123-199808000-00068","type":"journal-article","article-title":"Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus","volume":"43","author":"Drake","year":"1998","journal-title":"Neurosurgery"},{"key":"mepae4e2fbib12","author":"Drake","year":"1995","type":"book"},{"key":"mepae4e2fbib13","author":"EW","year":"2016","type":"book"},{"key":"mepae4e2fbib14","doi-asserted-by":"publisher","first-page":"2522","DOI":"10.1002\/app.11952","type":"journal-article","article-title":"Physical, mechanical, and biocompatibility evaluation of three different types of silicone rubber","volume":"88","author":"Fallahi","year":"2003","journal-title":"J. Appl. Polym. Sci."},{"key":"mepae4e2fbib15","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/s00701-015-2618-y","type":"journal-article","article-title":"Parametric study of ventricular catheters for hydrocephalus","volume":"158","author":"Galarza","year":"2016","journal-title":"Acta Neurochir"},{"key":"mepae4e2fbib16","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1007\/s00381-014-2477-5","type":"journal-article","article-title":"New designs of ventricular catheters for hydrocephalus by 3-D computational fluid dynamics","volume":"31","author":"Galarza","year":"2015","journal-title":"Childs Nerv. Syst."},{"key":"mepae4e2fbib17","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1007\/s00381-013-2226-1","type":"journal-article","article-title":"Computational fluid dynamics of ventricular catheters used for the treatment of hydrocephalus: a 3D analysis","volume":"30","author":"Galarza","year":"2014","journal-title":"Childs Nerv. Syst."},{"key":"mepae4e2fbib18","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1186\/s12938-016-0182-1","type":"journal-article","article-title":"Influence of the hole geometry on the flow distribution in ventricular catheters for hydrocephalus","volume":"15","author":"Gim\u00e9nez","year":"2016","journal-title":"Biomed. Eng. Online"},{"key":"mepae4e2fbib19","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1159\/000028979","type":"journal-article","article-title":"Ventriculoperitoneal shunt flow dependency on the number of patent holes in a ventricular catheter","volume":"33","author":"Ginsberg","year":"2000","journal-title":"Pediatr. Neurosurg."},{"key":"mepae4e2fbib20","doi-asserted-by":"publisher","first-page":"1221","DOI":"10.1007\/s00381-011-1430-0","type":"journal-article","article-title":"Does drainage hole size influence adhesion on ventricular catheters?","volume":"27","author":"Harris","year":"2011","journal-title":"Childs Nerv. Syst."},{"key":"mepae4e2fbib21","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.expneurol.2009.12.027","type":"journal-article","article-title":"Mechanical contributions to astrocyte adhesion using a novel in vitro model of catheter obstruction","volume":"222","author":"Harris","year":"2010","journal-title":"Exp. Neurol."},{"key":"mepae4e2fbib22","doi-asserted-by":"publisher","first-page":"926","DOI":"10.3171\/jns.1990.72.6.0926","type":"journal-article","article-title":"Fluid flow performance of a new siphon-control device for ventricular shunts","volume":"72","author":"Horton","year":"1990","journal-title":"J. Neurosurg."},{"key":"mepae4e2fbib23","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1136\/vr.156.7.206","type":"journal-article","article-title":"Subdural accumulation of fluid in a dog after the insertion of a ventriculoperitoneal shunt","volume":"156","author":"Kitagawa","year":"2005","journal-title":"Vet. Rec."},{"key":"mepae4e2fbib24","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1159\/000120767","type":"journal-article","article-title":"Echocardiographic detection of intracardiac thrombi complicating ventriculo-atrial shunt","volume":"20","author":"Ladouceur","year":"1994","journal-title":"Pediatr. Neurosurg."},{"key":"mepae4e2fbib25","doi-asserted-by":"publisher","first-page":"426","DOI":"10.3171\/jns.2003.99.2.0426","type":"journal-article","article-title":"Computational and experimental study of proximal flow in ventricular catheters","volume":"99","author":"Lin","year":"2003","journal-title":"J. Neurosurg."},{"key":"mepae4e2fbib26","doi-asserted-by":"publisher","DOI":"10.1080\/23311916.2020.1802816","type":"journal-article","article-title":"Gear concept selection procedure using fuzzy QFD, AHP and tacit knowledge","volume":"7","author":"Maputi","year":"2020","journal-title":"Cogent. Eng."},{"key":"mepae4e2fbib27","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1159\/000058428","type":"journal-article","article-title":"Cerebrospinal fluid shunt survival and etiology of failures: a seven-year institutional experience","volume":"36","author":"McGirt","year":"2002","journal-title":"Pediatr. Neurosurg."},{"key":"mepae4e2fbib28","first-page":"pp127","type":"journal-article","article-title":"A decision-based approach to concurrent design","author":"Mistree","year":"1993","journal-title":"ConcurrentEngineering"},{"key":"mepae4e2fbib29","first-page":"4","type":"conference-proceedings","article-title":"Biocompatibility studies on silicone rubber","author":"Mohanan","year":"1995"},{"key":"mepae4e2fbib30","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s00163-004-0054-8","type":"journal-article","article-title":"A review of robust design methods for multiple responses","volume":"15","author":"Murphy","year":"2005","journal-title":"Res. Eng. Des."},{"key":"mepae4e2fbib31","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1111\/j.1740-8261.2011.01865.x","type":"journal-article","article-title":"Imaging diagnosis\u2014ventriculo\u2010peritoneal shunt associated infection in a dog","volume":"53","author":"Platt","year":"2012","journal-title":"Vet. Radiol. Ultrasound."},{"key":"mepae4e2fbib32","doi-asserted-by":"publisher","first-page":"775","DOI":"10.3171\/jns.1973.39.6.0775","type":"journal-article","article-title":"Two unusual complications of a ventriculoperitoneal shunt: case report","volume":"39","author":"Portnoy","year":"1973","journal-title":"J. Neurosurg."},{"key":"mepae4e2fbib33","doi-asserted-by":"publisher","first-page":"73","DOI":"10.17221\/6698-VETMED","type":"journal-article","article-title":"Hydrocephalus in dogs: a review Veterin\u00e1rn\u00ed Medic\u00edna","volume":"58","author":"Przyborowska","year":"2013"},{"key":"mepae4e2fbib34","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/1743-8454-5-2","type":"journal-article","article-title":"The definition and classification of hydrocephalus: a personal recommendation to stimulate debate","volume":"5","author":"Rekate","year":"2008","journal-title":"Cerebrospinal Fluid Res."},{"key":"mepae4e2fbib35","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1136\/pgmj.58.683.566","type":"journal-article","article-title":"Ventriculo-atrial shunt nephritis","volume":"58","author":"Searle","year":"1982","journal-title":"Postgrad Med. J."},{"key":"mepae4e2fbib36","doi-asserted-by":"publisher","DOI":"10.1115\/1.4063157","type":"journal-article","article-title":"Exploring robust decisions in the design of coupled engineered systems","volume":"145","author":"Sharma","year":"2023","journal-title":"J. Mech. Des."},{"key":"mepae4e2fbib37","first-page":"p V03AT03A007","type":"book","volume":"vol 85383","author":"Sharma","year":"2021"},{"key":"mepae4e2fbib38","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1111\/j.1532-950X.2011.00832.x","type":"journal-article","article-title":"Treatment of hydrocephalus with ventriculoperitoneal shunting in twelve dogs","volume":"40","author":"Shihab","year":"2011","journal-title":"Vet. Surg."},{"key":"mepae4e2fbib39","doi-asserted-by":"publisher","first-page":"179457","DOI":"10.1109\/ACCESS.2020.3026350","type":"journal-article","article-title":"Rapid prediction of brain injury pattern in mTBI by combining FE analysis with a machine-learning based approach","volume":"8","author":"Shim","year":"2020","journal-title":"IEEE Access"},{"key":"mepae4e2fbib40","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1007\/s00381-009-1055-8","type":"journal-article","article-title":"Perforation holes in ventricular catheters\u2014is less more?","volume":"26","author":"Thomale","year":"2010","journal-title":"Childs Nerv. Syst."},{"key":"mepae4e2fbib41","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.cvsm.2009.09.008","type":"journal-article","article-title":"Hydrocephalus in dogs and cats","volume":"40","author":"Thomas","year":"2010","journal-title":"Vet. Clin. Small Anim. Pract."},{"key":"mepae4e2fbib42","doi-asserted-by":"publisher","first-page":"31","DOI":"10.3171\/jns.2000.92.1.0031","type":"journal-article","article-title":"Risk factors for repeated cerebrospinal shunt failures in pediatric patients with hydrocephalus","volume":"92","author":"Tuli","year":"2000","journal-title":"J. Neurosurg."},{"key":"mepae4e2fbib43","author":"Yingling","year":"2020","type":"book"}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae4e2f","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae4e2f\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae4e2f\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae4e2f\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T07:30:37Z","timestamp":1773905437000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae4e2f"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,19]]},"references-count":43,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,3,19]]},"published-print":{"date-parts":[[2026,4,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1873-4030\/ae4e2f","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,19]]},"assertion":[{"value":"Mitigating failures and enhancing reliability of a canine ventricular shunt through robust multi-objective design method","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2025-09-19","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-03-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-03-19","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}