{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T07:01:28Z","timestamp":1784617288415,"version":"3.55.0"},"reference-count":38,"publisher":"IOP Publishing","issue":"7","license":[{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":20,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"tdm","delay-in-days":20,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":20,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":20,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":20,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"},{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":20,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/questions\/alternative-author-rights-policies\/"}],"funder":[{"DOI":"10.13039\/100000738","name":"U.S. Department of Veterans Affairs","doi-asserted-by":"crossref","award":["I01 RX003700"],"award-info":[{"award-number":["I01 RX003700"]}],"id":[{"id":"10.13039\/100000738","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2026,7,1]]},"DOI":"10.1088\/1873-4030\/ae8544","type":"journal-article","created":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T22:47:53Z","timestamp":1783032473000},"page":"075007","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Development and experimental characterization of a cadaveric stance simulator for residual limb biomechanics"],"prefix":"10.1088","volume":"147","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-1066-6780","authenticated-orcid":true,"given":"David V","family":"Herlihy","sequence":"first","affiliation":[{"name":"Narrows Institute for Biomedical Research and Education, Inc."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8150-1533","authenticated-orcid":false,"given":"John M","family":"Chomack","sequence":"additional","affiliation":[{"name":"Veterans Affairs New York Harbor Healthcare System"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6079-4629","authenticated-orcid":false,"given":"David N","family":"Paglia","sequence":"additional","affiliation":[{"name":"Rutgers-New Jersey Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1366-3447","authenticated-orcid":true,"given":"Charlene","family":"Wetterstrand","sequence":"additional","affiliation":[{"name":"Rutgers-New Jersey Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0282-1104","authenticated-orcid":true,"given":"J Patrick","family":"O\u2019Connor","sequence":"additional","affiliation":[{"name":"Rutgers-New Jersey Medical School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4931-572X","authenticated-orcid":false,"given":"Susan E","family":"D\u2019Andrea","sequence":"additional","affiliation":[{"name":"University of Rhode Island"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6721-7517","authenticated-orcid":true,"given":"Jason T","family":"Maikos","sequence":"additional","affiliation":[{"name":"Veterans Affairs New York Harbor Healthcare System"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,7,21]]},"reference":[{"key":"mepae8544bib1","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1109\/TBME.2007.908072","type":"journal-article","article-title":"Gait simulation via a 6-DOF parallel robot with iterative learning control","volume":"55","author":"Aubin","year":"2008","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"mepae8544bib2","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1002\/pmrj.12899","type":"journal-article","article-title":"The relationship between residual limb health, motion within the socket, and prosthetic suspension","volume":"15","author":"Baumann","year":"2023","journal-title":"PM&R"},{"key":"mepae8544bib3","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.physio.2010.12.004","type":"journal-article","article-title":"Normal walking speed: a descriptive meta-analysis","volume":"97","author":"Bohannon","year":"2011","journal-title":"Physiotherapy"},{"key":"mepae8544bib4","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.neulet.2009.01.053","type":"journal-article","article-title":"Effects of postural threat on walking features of Parkinson\u2019s disease patients","volume":"452","author":"Caetano","year":"2009","journal-title":"Neurosci. Lett."},{"key":"mepae8544bib5","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1097\/00008526-200012010-00007","type":"journal-article","article-title":"Flow constraint and loading rate effects on prosthetic liner material and human tissue mechanical response","volume":"12","author":"Covey","year":"2000","journal-title":"JPO J. Prosthet. Orthot."},{"key":"mepae8544bib6","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1002\/ca.21152","type":"journal-article","article-title":"Human surrogates for injury biomechanics research","volume":"24","author":"Crandall","year":"2011","journal-title":"Clin. Anat."},{"key":"mepae8544bib7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1757-1146-7-S1-A15","type":"journal-article","article-title":"The use of a robotic gait simulator for the development of an alignment tool for lower limb prostheses","volume":"7","author":"De Raeve","year":"2014","journal-title":"J. Foot Ankle Res."},{"key":"mepae8544bib8","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1177\/0309364611431625","type":"journal-article","article-title":"Pistoning assessment in lower limb prosthetic sockets","volume":"36","author":"Eshraghi","year":"2012","journal-title":"Prosthet. Orthot. Int."},{"key":"mepae8544bib9","doi-asserted-by":"publisher","DOI":"10.1016\/j.humov.2024.103301","type":"journal-article","article-title":"Effects of freezing of gait on vertical ground reaction force in Parkinson\u2019s disease","volume":"98","author":"Etoom","year":"2024","journal-title":"Hum. Mov. Sci."},{"key":"mepae8544bib10","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1016\/S0021-9290(00)00223-2","type":"journal-article","article-title":"A closed-loop cadaveric foot and ankle loading model","volume":"34","author":"Hansen","year":"2001","journal-title":"J. Biomech."},{"key":"mepae8544bib11","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1177\/107110070302400808","type":"journal-article","article-title":"In vitro simulation of stance phase gait part I: model verification","volume":"24","author":"Hurschler","year":"2003","journal-title":"Foot Ankle Int."},{"key":"mepae8544bib12","doi-asserted-by":"publisher","first-page":"66","DOI":"10.3113\/FAI.2008.0066","type":"journal-article","article-title":"Simulation of contact gait in the cadaveric lower extremity using a novel below knee simulator","volume":"29","author":"Iaquinto","year":"2008","journal-title":"Foot Ankle Int."},{"key":"mepae8544bib13","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1142\/S0218957701000490","type":"journal-article","article-title":"In vitro simulation of the stance phase in human gait","volume":"5","author":"Kim","year":"2001","journal-title":"J. Musculoskelet. Res."},{"key":"mepae8544bib14","doi-asserted-by":"publisher","DOI":"10.2196\/57329","type":"journal-article","article-title":"Quantifying bone and skin movement in the residual limb-socket interface of individuals with transtibial limb loss using dynamic stereo x-ray: protocol for a lower limb loss cadaver and clinical study","volume":"13","author":"Maikos","year":"2024","journal-title":"JMIR Res. Protocols"},{"key":"mepae8544bib15","article-title":"Design, development and engineering of a bench for testing lower limb prosthesis, with focus on high-technological solutions","author":"Marinelli","year":"2016","type":"other"},{"key":"mepae8544bib16","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2025.112513","type":"journal-article","article-title":"Evaluating interface pressure in a lower-limb prosthetic socket: comparison of FEM and experimental measurements on a roll-over simulator","volume":"180","author":"Matray","year":"2025","journal-title":"J. Biomech."},{"key":"mepae8544bib17","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1177\/0954411917690764","type":"journal-article","article-title":"Development of a residuum\/socket interface simulator for lower limb prosthetics","volume":"231","author":"McGrath","year":"2017","journal-title":"Proc. Inst. Mech. Eng. Part H: J. Eng. Med."},{"key":"mepae8544bib18","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1016\/j.jbiomech.2014.11.044","type":"journal-article","article-title":"Inertial control as novel technique for in vitro gait simulations","volume":"48","author":"Natsakis","year":"2015","journal-title":"J. Biomech."},{"key":"mepae8544bib19","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1177\/0954411915617983","type":"journal-article","article-title":"Foot\u2013ankle simulators: a tool to advance biomechanical understanding of a complex anatomical structure","volume":"230","author":"Natsakis","year":"2016","journal-title":"Proc. Inst. Mech. Eng. Part H: J. Eng. Med."},{"key":"mepae8544bib20","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1177\/107110070102200404","type":"journal-article","article-title":"The effect of posterior tibial tendon dysfunction on hindfoot kinematics","volume":"22","author":"Niki","year":"2001","journal-title":"Foot Ankle Int."},{"key":"mepae8544bib21","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1111\/j.1748-1716.1989.tb08655.x","type":"journal-article","article-title":"Ground reaction forces at different speeds of human walking and running","volume":"136","author":"Nilsson","year":"1989","journal-title":"Acta Physiol. Scand."},{"key":"mepae8544bib22","doi-asserted-by":"publisher","DOI":"10.1115\/1.4000851","type":"journal-article","article-title":"Design and validation of a general purpose robotic testing system for musculoskeletal applications","volume":"132","author":"Noble","year":"2010","journal-title":"ASME J. Biomech. Eng."},{"key":"mepae8544bib23","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1115\/1.2834289","type":"journal-article","article-title":"Biomechanical properties of human cadaveric ankle-subtalar joints in quasi-static loading","volume":"120","author":"Parentea","year":"1998","journal-title":"J. Biomech. Eng."},{"key":"mepae8544bib24","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1177\/0954411913490455","type":"journal-article","article-title":"An in vitro approach to the evaluation of foot-ankle kinematics: performance evaluation of a custom-built gait simulator","volume":"227","author":"Peeters","year":"2013","journal-title":"Proc. Inst. Mech. Eng. Part H: J. Eng. Med."},{"key":"mepae8544bib25","doi-asserted-by":"publisher","first-page":"1293-304","DOI":"10.1682\/JRRD.2011.02.0018","type":"journal-article","article-title":"Quantifiable patterns of limb loading and unloading during hemiparetic gait: relation to kinetic and kinematic parameters","volume":"49","author":"Raja","year":"2012","journal-title":"J. Rehabil. Res. Dev."},{"key":"mepae8544bib26","doi-asserted-by":"publisher","first-page":"3955","DOI":"10.3390\/ma13183955","type":"journal-article","article-title":"Developing an analogue residual limb for comparative DVC analysis of transtibial prosthetic socket designs","volume":"13","author":"Rankin","year":"2020","journal-title":"Materials"},{"key":"mepae8544bib27","doi-asserted-by":"publisher","first-page":"64","DOI":"10.3390\/biomechanics5030064","type":"journal-article","article-title":"Exploring opportunities for advancements in lower limb socket fabrication and testing: a review","volume":"5","author":"Salgado Manrique","year":"2025","journal-title":"Biomechanics"},{"key":"mepae8544bib28","doi-asserted-by":"publisher","first-page":"1382-8","DOI":"10.1249\/MSS.0000000000002917","type":"journal-article","article-title":"Vertical loading rate is not associated with running injury, regardless of calculation method","volume":"54","author":"Schmida","year":"2022","journal-title":"Med. Sci. Sports Exerc."},{"key":"mepae8544bib29","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1016\/j.jmbbm.2016.02.020","type":"journal-article","article-title":"Multi-material 3-D viscoelastic model of a transtibial residuum from in-vivo indentation and MRI data","volume":"59","author":"Sengeh","year":"2016","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"mepae8544bib30","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1016\/S0268-0033(98)00003-5","type":"journal-article","article-title":"A dynamic cadaver model of the stance phase of gait: performance characteristics and kinetic validation","volume":"13","author":"Sharkey","year":"1998","journal-title":"Clin. Biomech."},{"key":"mepae8544bib31","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1109\/86.788464","type":"journal-article","article-title":"In vivo indentation of lower extremity limb soft tissues","volume":"7","author":"Silver-Thorn","year":"1999","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"mepae8544bib32","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1097\/00003086-198510000-00011","type":"journal-article","article-title":"Changes in tibiotalar joint contact areas following experimentally induced tibial angular deformities","volume":"199","author":"Tarr","year":"1985","journal-title":"Clin. Orthop. Relat. Res."},{"key":"mepae8544bib33","first-page":"193","type":"journal-article","article-title":"The gait simulator for lower limb exoprostheses \u2013 overview and first measurements for comparison of microprocessor controlled knee joints","volume":"13","author":"Thiele","year":"2015","journal-title":"Facta Univ. Ser."},{"key":"mepae8544bib34","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1109\/TNSRE.2003.810436","type":"journal-article","article-title":"Nonlinear elastic material property estimation of lower extremity residual limb tissues","volume":"11","author":"T\u00f6n\u00fck","year":"2003","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"mepae8544bib35","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.1177\/0954411920938902","type":"journal-article","article-title":"Design and validation of a foot\u2013ankle dynamic simulator with a 6-degree-of-freedom parallel mechanism","volume":"234","author":"Wang","year":"2020","journal-title":"Proc. Inst. Mech. Eng. Part H: J. Eng. Med."},{"key":"mepae8544bib36","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.gaitpost.2025.05.010","type":"journal-article","article-title":"Stroke-related factors associated with gait asymmetry in ambulatory stroke survivors: a systematic review and meta-analysis","volume":"121","author":"Xu","year":"2025","journal-title":"Gait Posture"},{"key":"mepae8544bib37","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/S0021-9290(96)00142-X","type":"journal-article","article-title":"A kinematic-freedom analysis of a flexed-knee-stance testing rig","volume":"30","author":"Zavatsky","year":"1997","journal-title":"J. Biomech."},{"key":"mepae8544bib38","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1186\/s13018-020-01830-3","type":"journal-article","article-title":"In vitro study of foot bone kinematics via a custom-made cadaveric gait simulator","volume":"15","author":"Zhu","year":"2020","journal-title":"J. Orthop. Surg. Res."}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T06:07:50Z","timestamp":1784614070000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8544"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,1]]},"references-count":38,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7,21]]},"published-print":{"date-parts":[[2026,7,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1873-4030\/ae8544","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,1]]},"assertion":[{"value":"Development and experimental characterization of a cadaveric stance simulator for residual limb biomechanics","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-05","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-02","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-21","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}