{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T10:47:40Z","timestamp":1785754060204,"version":"3.56.0"},"reference-count":90,"publisher":"IOP Publishing","issue":"8","license":[{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2026,8,3]]},"DOI":"10.1088\/1873-4030\/ae8dcc","type":"journal-article","created":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T22:47:49Z","timestamp":1784674069000},"page":"08TR01","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Centre of rotation in total hip arthroplasty: a critical review with emphasis on three-dimensional planning"],"prefix":"10.1088","volume":"147","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2721-7694","authenticated-orcid":true,"given":"Sara De","family":"Angelis","sequence":"first","affiliation":[{"name":"University College London"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4086-1609","authenticated-orcid":false,"given":"Johann","family":"Henckel","sequence":"additional","affiliation":[{"name":"Royal National Orthopaedic Hospital NHS Trust"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1281-6886","authenticated-orcid":false,"given":"Alister","family":"Hart","sequence":"additional","affiliation":[{"name":"Royal National Orthopaedic Hospital NHS Trust"},{"name":"Institute of Orthopaedics and Musculoskeletal Science, University College London"},{"name":"Cleveland Clinic London"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4212-3741","authenticated-orcid":false,"given":"Anna Di","family":"Laura","sequence":"additional","affiliation":[{"name":"University College London"},{"name":"Royal National Orthopaedic Hospital NHS Trust"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,8,3]]},"reference":[{"key":"mepae8dccbib1","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/aced0d","type":"journal-article","article-title":"Structural optimization of orthopedic hip implant using parametric and non-parametric optimization techniques","volume":"9","author":"Abdullah","year":"2023","journal-title":"Biomed. Phys. Eng. Express"},{"key":"mepae8dccbib2","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s00256-023-04351-2","type":"journal-article","article-title":"\u201cThe accuracy of the EOS imaging system to assess hip abnormalities in adolescents and adults:\u201d a systematic review and meta-analysis","volume":"53","author":"Alghamdi","year":"2024","journal-title":"Skelet. Radiol."},{"key":"mepae8dccbib3","doi-asserted-by":"publisher","first-page":"1591","DOI":"10.3390\/medicina59091591","type":"journal-article","article-title":"Current concepts in diagnosis and management of patients undergoing total hip replacement with concurrent disorders of spinopelvic anatomy: a narrative review","volume":"59","author":"Ambrus","year":"2023","journal-title":"Medicina"},{"key":"mepae8dccbib4","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.jjoisr.2025.12.006","type":"journal-article","article-title":"Robotic-assisted total hip arthroplasty","volume":"4","author":"Asim","year":"2026","journal-title":"J. Joint Surg. Res."},{"key":"mepae8dccbib5","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1302\/0301-620X.97B6.35129","type":"journal-article","article-title":"The accuracy of positioning of a custom-made implant within a large acetabular defect at revision arthroplasty of the hip","volume":"97","author":"Baauw","year":"2015","journal-title":"Bone Joint J."},{"key":"mepae8dccbib6","doi-asserted-by":"publisher","first-page":"1240","DOI":"10.1002\/jor.25455","type":"journal-article","article-title":"The effect of surgical change to hip geometry on hip biomechanics after primary total hip arthroplasty","volume":"41","author":"Bahl","year":"2023","journal-title":"J. Orthop. Res."},{"key":"mepae8dccbib7","doi-asserted-by":"publisher","first-page":"1921","DOI":"10.1016\/j.arth.2024.12.014","type":"journal-article","article-title":"Robotic-assisted total hip arthroplasty provides greater implant placement accuracy and lower complication rates, but not superior clinical results compared to the conventional manual approach: a systematic review and meta-analysis","volume":"40","author":"Bensa","year":"2025","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib8","doi-asserted-by":"publisher","first-page":"386","DOI":"10.4103\/ortho.IJOrtho_144_17","type":"journal-article","article-title":"Current concepts in acetabular positioning in total hip arthroplasty","volume":"51","author":"Bhaskar","year":"2017","journal-title":"Indian J. Orthop."},{"key":"mepae8dccbib9","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1007\/s00264-008-0683-z","type":"journal-article","article-title":"Influence of the acetabular cup position on hip load during arthroplasty in hip dysplasia","volume":"33","author":"Bicanic","year":"2009","journal-title":"Int. Orthop."},{"key":"mepae8dccbib10","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1016\/j.arth.2012.12.001","type":"journal-article","article-title":"The use of patient-specific instrumentation improves the accuracy of acetabular component placement","volume":"28","author":"Buller","year":"2013","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib11","doi-asserted-by":"publisher","first-page":"6674","DOI":"10.3390\/jcm11226674","type":"journal-article","article-title":"Robotics in total hip arthroplasty: current concepts","volume":"11","author":"Bullock","year":"2022","journal-title":"J. Clin. Med."},{"key":"mepae8dccbib12","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1186\/s13018-019-1331-6","type":"journal-article","article-title":"A novel positioner for accurately sitting the acetabular component: a retrospective comparative study","volume":"14","author":"Cao","year":"2019","journal-title":"J. Orthop. Surg. Res."},{"key":"mepae8dccbib13","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/j.artd.2020.05.010","type":"journal-article","article-title":"The prevalence of abnormal spinopelvic relationships in patients presenting for primary total hip arthroplasty","volume":"6","author":"Carender","year":"2020","journal-title":"Arthroplast. Today"},{"key":"mepae8dccbib14","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1302\/2058-5241.4.180075","type":"journal-article","article-title":"Total hip arthroplasty planning","volume":"4","author":"Colombi","year":"2019","journal-title":"EFORT Open Rev."},{"key":"mepae8dccbib15","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1016\/j.jor.2022.10.001","type":"journal-article","article-title":"The efficacy of patient specific instrumentation (PSI) in total hip arthroplasty (THA): a systematic review and meta-analysis","volume":"34","author":"Constantinescu","year":"2022","journal-title":"J. Orthop."},{"key":"mepae8dccbib16","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1007\/s11999-008-0486-y","type":"journal-article","article-title":"A new digital preoperative planning method for total hip arthroplasties","volume":"467","author":"Crooijmans","year":"2009","journal-title":"Clin. Orthop. Relat. Res."},{"key":"mepae8dccbib17","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1007\/s11999-010-1554-7","type":"journal-article","article-title":"Hip offset in total hip arthroplasty: quantitative measurement with navigation","volume":"469","author":"Dastane","year":"2011","journal-title":"Clin. Orthop. Relat. Res."},{"key":"mepae8dccbib18","doi-asserted-by":"publisher","first-page":"2016","DOI":"10.1002\/jor.25547","type":"journal-article","article-title":"Statistical shape modeling of the large acetabular defect in hip revision surgery","volume":"41","author":"De Angelis","year":"2023","journal-title":"J. Orthop. Res."},{"key":"mepae8dccbib19","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2025.1629271","type":"journal-article","article-title":"Computational modelling of acetabular morphology and its implications for cup positioning","volume":"13","author":"De Angelis","year":"2025","journal-title":"Front. Bioeng. Biotechnol."},{"key":"mepae8dccbib20","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.arth.2004.04.016","type":"journal-article","article-title":"The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty","volume":"20","author":"Della Valle","year":"2005","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib21","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1302\/0301-620X.107B4.BJJ-2024-0982.R1","type":"journal-article","article-title":"Robotic arm-assisted acetabular reconstruction in revision total hip arthroplasty: a clinical study with minimum two-year follow-up","volume":"107","author":"Deng","year":"2025","journal-title":"Bone Joint J."},{"key":"mepae8dccbib22","doi-asserted-by":"publisher","first-page":"e22","DOI":"10.2106\/JBJS.OA.22.00120","type":"journal-article","article-title":"Custom 3D-printed implants for acetabular reconstruction: intermediate-term functional and radiographic results","volume":"8","author":"Di Laura","year":"2023","journal-title":"JBJS Open Access."},{"key":"mepae8dccbib23","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1530\/EOR-22-0039","type":"journal-article","article-title":"The modern state of femoral, acetabular, and global offsets in total hip arthroplasty: a narrative review","volume":"8","author":"DiGiovanni","year":"2023","journal-title":"EFORT Open Rev."},{"key":"mepae8dccbib24","doi-asserted-by":"publisher","first-page":"2640","DOI":"10.1002\/jor.24752","type":"journal-article","article-title":"Can custom 3D printed implants successfully reconstruct massive acetabular defects? A 3D-CT assessment","volume":"38","author":"Durand-Hill","year":"2020","journal-title":"J. Orthop. Res."},{"key":"mepae8dccbib25","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1302\/0301-620X.80B3.0800382","type":"journal-article","article-title":"The value of preoperative planning for total hip arthroplasty","volume":"80","author":"Eggli","year":"1998","journal-title":"J. Bone Joint Surg. Br."},{"key":"mepae8dccbib26","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/BF01631394","type":"journal-article","article-title":"Locating the center of rotation of the hip","volume":"21","author":"Fessy","year":"1999","journal-title":"Surg. Radiol. Anat."},{"key":"mepae8dccbib27","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1302\/0301-620X.106B4.BJJ-2023-1045.R1","type":"journal-article","article-title":"A prospective randomized controlled trial comparing CT-based planning with conventional total hip arthroplasty versus robotic arm-assisted total hip arthroplasty","volume":"106","author":"Fontalis","year":"2024a","journal-title":"Bone Joint J."},{"key":"mepae8dccbib28","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1007\/s00264-022-05646-0","type":"journal-article","article-title":"Functional implant positioning in total hip arthroplasty and the role of robotic-arm assistance","volume":"47","author":"Fontalis","year":"2023","journal-title":"Int. Orthop."},{"key":"mepae8dccbib29","doi-asserted-by":"publisher","first-page":"S80","DOI":"10.1016\/j.arth.2024.05.054","type":"journal-article","article-title":"Two-dimensional versus three-dimensional preoperative planning in total hip arthroplasty","volume":"39","author":"Fontalis","year":"2024b","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib30","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111620","type":"journal-article","article-title":"A pilot study to identify suitable MRI protocols for preoperative planning of total hip arthroplasty","volume":"178","author":"Ghotra","year":"2024","journal-title":"Eur. J. Radiol."},{"key":"mepae8dccbib31","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s00264-006-0317-2","type":"journal-article","article-title":"The utility and precision of analogue and digital preoperative planning for total hip arthroplasty","volume":"32","author":"Gonz\u00e1lez Della Valle","year":"2008","journal-title":"Int. Orthop."},{"key":"mepae8dccbib32","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1051\/sicotj\/2017054","type":"journal-article","article-title":"Patient-specific instruments: advantages and pitfalls","volume":"3","author":"Hafez","year":"2017","journal-title":"SICOT J."},{"key":"mepae8dccbib33","doi-asserted-by":"publisher","first-page":"2569","DOI":"10.3390\/jcm9082569","type":"journal-article","article-title":"The impact of spinopelvic mobility on arthroplasty: implications for hip and spine surgeons","volume":"9","author":"Haffer","year":"2020","journal-title":"J. Clin. Med."},{"key":"mepae8dccbib34","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1016\/j.arth.2013.12.033","type":"journal-article","article-title":"Comparisons of preoperative three-dimensional planning and surgical reconstruction in primary cementless total hip arthroplasty","volume":"29","author":"Hassani","year":"2014","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib35","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.3390\/medicina58091254","type":"journal-article","article-title":"Revision of a failed primary total hip arthroplasty following excessive reaming with a medial cup protrusion","volume":"58","author":"Ivanova","year":"2022","journal-title":"Medicina"},{"key":"mepae8dccbib36","doi-asserted-by":"publisher","first-page":"509","DOI":"10.3109\/17453679409000901","type":"journal-article","article-title":"Radiographic determination of the anatomic hip joint center. A cadaver study","volume":"65","author":"John","year":"1994","journal-title":"Acta Orthop. Scand."},{"key":"mepae8dccbib37","doi-asserted-by":"publisher","first-page":"5345","DOI":"10.1007\/s00402-022-04697-7","type":"journal-article","article-title":"Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs","volume":"143","author":"Kaiser","year":"2023","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"mepae8dccbib38","first-page":"140","type":"journal-article","article-title":"A 12- to 18-year radiographic follow-up study of Charnley low-friction arthroplasty. The role of the center of rotation","volume":"296","author":"Karachalios","year":"1993","journal-title":"Clin. Orthop. Relat. Res."},{"key":"mepae8dccbib39","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1302\/2058-5241.4.180088","type":"journal-article","article-title":"The current role of robotics in total hip arthroplasty","volume":"4","author":"Kayani","year":"2019","journal-title":"EFORT Open Rev."},{"key":"mepae8dccbib40","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1177\/1120700019889334","type":"journal-article","article-title":"The learning curve of robotic-arm assisted acetabular cup positioning during total hip arthroplasty","volume":"31","author":"Kayani","year":"2021","journal-title":"Hip Int."},{"key":"mepae8dccbib41","doi-asserted-by":"publisher","first-page":"609","DOI":"10.5435\/JAAOS-D-20-00715","type":"journal-article","article-title":"The cost of robot-assisted total hip arthroplasty: comparing safety and hospital charges to conventional total hip arthroplasty","volume":"29","author":"Kirchner","year":"2021","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"mepae8dccbib42","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1136\/postgradmedj-2021-141135","type":"journal-article","article-title":"Does robotic-assisted surgery improve outcomes of total hip arthroplasty compared to manual technique? A systematic review and meta-analysis","volume":"99","author":"Kumar","year":"2023","journal-title":"Postgrad. Med. J."},{"key":"mepae8dccbib43","doi-asserted-by":"publisher","first-page":"502","DOI":"10.2106\/00004623-198668040-00004","type":"journal-article","article-title":"Total hip arthroplasty in juvenile rheumatoid arthritis. Two to eleven-year results","volume":"68","author":"Lachiewicz","year":"1986","journal-title":"J. Bone Joint Surg. Am."},{"key":"mepae8dccbib44","doi-asserted-by":"publisher","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","type":"journal-article","article-title":"Dislocations after total hip-replacement arthroplasties","volume":"60","author":"Lewinnek","year":"1978","journal-title":"J. Bone Joint Surg. Am."},{"key":"mepae8dccbib45","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1186\/s13018-023-04095-8","type":"journal-article","article-title":"Robotic arm-assisted total hip arthroplasty for preoperative planning and intraoperative decision-making","volume":"18","author":"Lu","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"mepae8dccbib46","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1016\/j.jor.2018.08.040","type":"journal-article","article-title":"Restoration of center of rotation and balance of THR","volume":"15","author":"Lum","year":"2018","journal-title":"J. Orthop."},{"key":"mepae8dccbib47","doi-asserted-by":"publisher","first-page":"36","DOI":"10.3109\/17453674.2015.1091955","type":"journal-article","article-title":"Association between changes in global femoral offset after total hip arthroplasty and function, quality of life, and abductor muscle strength. A prospective cohort study of 222 patients","volume":"87","author":"Mahmood","year":"2016","journal-title":"Acta Orthop."},{"key":"mepae8dccbib48","doi-asserted-by":"publisher","first-page":"26","DOI":"10.5371\/hp.2024.36.1.26","type":"journal-article","article-title":"The value of computed tomography scan in three-dimensional planning and intraoperative navigation in primary total hip arthroplasty","volume":"36","author":"Mancino","year":"2024","journal-title":"Hip Pelvis."},{"key":"mepae8dccbib49","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1302\/0301-620X.77B6.7593096","type":"journal-article","article-title":"Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty","volume":"77","author":"McGrory","year":"1995","journal-title":"J. Bone Joint Surg. Br."},{"key":"mepae8dccbib50","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1007\/s43465-020-00061-2","type":"journal-article","article-title":"3D printed patient-specific acetabular jig for cup placement in total hip arthroplasty","volume":"54","author":"Mishra","year":"2020","journal-title":"Indian J. Orthop."},{"key":"mepae8dccbib51","doi-asserted-by":"publisher","first-page":"e24","DOI":"10.2106\/JBJS.RVW.24.00120","type":"journal-article","article-title":"Comparison of implant placement accuracy between manual, robot-assisted, computer-navigated, augmented reality navigated, patient-specific instrumentation, and accelerometer navigated total hip arthroplasty: a systematic review and network meta-analysis","volume":"12","author":"Miura","year":"2024","journal-title":"JBJS Rev."},{"key":"mepae8dccbib52","doi-asserted-by":"publisher","first-page":"1813","DOI":"10.1016\/j.arth.2018.01.041","type":"journal-article","article-title":"Cementless total hip arthroplasty in Crowe iii and iv dysplasia: high hip center and modular necks","volume":"33","author":"Montalti","year":"2018","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib53","doi-asserted-by":"publisher","DOI":"10.3389\/frai.2024.1417729","type":"journal-article","article-title":"The role of artificial intelligence in preoperative planning for total hip arthroplasty: a systematic review","volume":"7","author":"Mozafari","year":"2024","journal-title":"Front. Artif. Intell."},{"key":"mepae8dccbib54","first-page":"21","type":"journal-article","article-title":"3-D isotropic mr imaging for planning bone reconstruction in patients with femoroacetabular impingement","volume":"87","author":"Nordeck","year":"2015","journal-title":"Radiol. Technol."},{"key":"mepae8dccbib55","article-title":"The Oxford 2011 levels of evidence. oxford centre for evidence-based medicine","author":"OCEBM Levels of Evidence Working Group","year":"n.d.","type":"other"},{"key":"mepae8dccbib56","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-37798-3","type":"journal-article","article-title":"Automated segmentation of the mandibular canal and its anterior loop by deep learning","volume":"13","author":"Oliveira-santos","year":"2023","journal-title":"Sci. Rep."},{"key":"mepae8dccbib57","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.51498","type":"journal-article","article-title":"Intrapelvic cup migration following revision total hip arthroplasty: a case report and review of the literature","volume":"16","author":"Papagiannis","year":"2024","journal-title":"Cureus"},{"key":"mepae8dccbib58","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1177\/1120700019893636","type":"journal-article","article-title":"Current topics in robotic-assisted total hip arthroplasty: a review","volume":"30","author":"Perets","year":"2020","journal-title":"Hip Int."},{"key":"mepae8dccbib59","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.2217\/cer-2020-0255","type":"journal-article","article-title":"Robotic-assisted total hip arthroplasty: an economic analysis","volume":"10","author":"Pierce","year":"2021","journal-title":"J. Comp. Eff. Res."},{"key":"mepae8dccbib60","first-page":"281","type":"journal-article","article-title":"Radiologic evaluation of the rotation center of the hip","volume":"79","author":"Pierchon","year":"1993","journal-title":"Rev. Chir. Orthop. Reparatrice Appar. Mot."},{"key":"mepae8dccbib61","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1186\/s13018-025-05704-4","type":"journal-article","article-title":"Cup positioning relative to the acetabular rim planned with three-dimensional computed tomography improves precision in total hip arthroplasty: a randomized controlled trial","volume":"20","author":"Pongkunakorn","year":"2025","journal-title":"J. Orthop. Surg. Res."},{"key":"mepae8dccbib62","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1007\/s00402-023-05087-3","type":"journal-article","article-title":"The impact of retaining the femoral stem in revision total hip arthroplasty: a systematic review, meta-analysis, and meta-regression","volume":"144","author":"Poursalehian","year":"2024","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"mepae8dccbib63","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.2106\/00004623-198062070-00002","type":"journal-article","article-title":"Total hip arthroplasty in protrusio acetabuli of rheumatoid arthritis","volume":"62","author":"Ranawat","year":"1980","journal-title":"J. Bone Joint Surg. Am."},{"key":"mepae8dccbib64","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.arth.2014.08.003","type":"journal-article","article-title":"The learning curve associated with robotic-assisted total hip arthroplasty","volume":"30","author":"Redmond","year":"2015","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib65","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.gaitpost.2016.07.011","type":"journal-article","article-title":"Leg length and offset differences above 5mm after total hip arthroplasty are associated with altered gait kinematics","volume":"49","author":"Renkawitz","year":"2016","journal-title":"Gait Posture"},{"key":"mepae8dccbib66","doi-asserted-by":"publisher","first-page":"248","DOI":"10.5301\/HIP.2012.9283","type":"journal-article","article-title":"Effect of restoration of combined offset on stability of large head THA","volume":"22","author":"Robinson","year":"2012","journal-title":"Hip Int."},{"key":"mepae8dccbib67","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1186\/1471-2474-13-95","type":"journal-article","article-title":"Total hip arthroplasty: leg length inequality impairs functional outcomes and patient satisfaction","volume":"13","author":"R\u00f6der","year":"2012","journal-title":"BMC Musculoskelet. Disord."},{"key":"mepae8dccbib68","doi-asserted-by":"publisher","DOI":"10.1002\/jeo2.12080","type":"journal-article","article-title":"Orthopaedic surgeons display a positive outlook towards artificial intelligence: a survey among members of the AGA society for arthroscopy and joint surgery","volume":"11","author":"Rupp","year":"2024","journal-title":"J. Exp. Orthop."},{"key":"mepae8dccbib69","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1097\/00003086-200107000-00019","type":"journal-article","article-title":"Effect of femoral component offset on polyethylene wear in total hip arthroplasty","volume":"388","author":"Sakalkale","year":"2001","journal-title":"Clin. Orthop. Relat. Res."},{"key":"mepae8dccbib70","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.otsr.2011.09.023","type":"journal-article","article-title":"Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating","volume":"98","author":"Sariali","year":"2012","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"mepae8dccbib71","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1302\/0301-620X.91B3.21390","type":"journal-article","article-title":"Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck","volume":"91","author":"Sariali","year":"2009","journal-title":"J. Bone Joint Surg. Br."},{"key":"mepae8dccbib72","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.gaitpost.2020.02.008","type":"journal-article","article-title":"Effect of femoral offset and limb length discrepancy on hip joint muscle strength and gait trajectory after total hip arthroplasty","volume":"77","author":"Sato","year":"2020","journal-title":"Gait Posture"},{"key":"mepae8dccbib73","first-page":"432","type":"journal-article","article-title":"Primary hip arthroplasty templating on standard radiographs. A stepwise approach","volume":"76","author":"Scheerlinck","year":"2010","journal-title":"Acta Orthop. Belg."},{"key":"mepae8dccbib74","first-page":"479","type":"journal-article","article-title":"Radiological determination of the anatomic hip centre from pelvic landmarks","volume":"76","author":"Schofer","year":"2010","journal-title":"Acta Orthop. Belg."},{"key":"mepae8dccbib75","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1016\/j.arth.2012.06.009","type":"journal-article","article-title":"Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series","volume":"28","author":"Shaarani","year":"2013","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib76","doi-asserted-by":"publisher","first-page":"1658","DOI":"10.1016\/j.arth.2014.03.013","type":"journal-article","article-title":"Assessment of accuracy of marker ball placement in pre-operative templating for total hip arthroplasty","volume":"29","author":"Sinclair","year":"2014","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib77","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1016\/j.arth.2013.10.006","type":"journal-article","article-title":"Comparison of acetabular shell position using patient specific instruments vs. standard surgical instruments: a randomized clinical trial","volume":"29","author":"Small","year":"2014","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib78","doi-asserted-by":"publisher","first-page":"271","DOI":"10.3390\/medicina59020271","type":"journal-article","article-title":"Achieving precise cup positioning in direct anterior total hip arthroplasty: a narrative review","volume":"59","author":"Streck","year":"2023","journal-title":"Medicina"},{"key":"mepae8dccbib79","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1177\/1120700019828286","type":"journal-article","article-title":"A review of the evolution of robotic-assisted total hip arthroplasty","volume":"29","author":"Subramanian","year":"2019","journal-title":"Hip Int."},{"key":"mepae8dccbib80","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/s12938-016-0236-4","type":"journal-article","article-title":"3D-printing techniques in a medical setting: a systematic literature review","volume":"15","author":"Tack","year":"2016","journal-title":"Biomed. Eng. Online"},{"key":"mepae8dccbib81","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1177\/1120700019884547","type":"journal-article","article-title":"Postoperative radiographic evaluation and simulation study for optimal cup placement in high-hip centre total hip arthroplasty","volume":"31","author":"Takasago","year":"2021","journal-title":"Hip Int."},{"key":"mepae8dccbib82","type":"other","article-title":"UNSCEAR 2024 Report","volume":"vol II","author":"United Nations Scientific Committee on the Effects of Atomic Radiation","year":"2024"},{"key":"mepae8dccbib83","doi-asserted-by":"publisher","first-page":"212","DOI":"10.21037\/atm-20-3488","type":"journal-article","article-title":"Patient-specific total hip arthroplasty is superior to conventional methods for Crowe III and IV adult developmental hip dysplasia: a randomized controlled trial","volume":"9","author":"Wang","year":"2021","journal-title":"Ann. Transl. Med."},{"key":"mepae8dccbib84","doi-asserted-by":"publisher","first-page":"2177","DOI":"10.1016\/j.arth.2018.02.039","type":"journal-article","article-title":"Inferomedial hip center decreases failure rates in cementless total hip arthroplasty for Crowe II and III hip dysplasia","volume":"33","author":"Watts","year":"2018","journal-title":"J. Arthroplasty"},{"key":"mepae8dccbib85","doi-asserted-by":"publisher","first-page":"2235","DOI":"10.1007\/s00264-018-4193-3","type":"journal-article","article-title":"Customized implants for acetabular Paprosky III defects may be positioned with high accuracy in revision hip arthroplasty","volume":"43","author":"Weber","year":"2019","journal-title":"Int. Orthop."},{"key":"mepae8dccbib86","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.1302\/0301-620X.104B10.BJJ-2022-0508.R1","type":"journal-article","article-title":"Reconstruction of Paprosky III defects with custom-made implants: do we get them in the correct position?: short-term radiological results","volume":"104","author":"Wessling","year":"2022","journal-title":"Bone Joint J."},{"key":"mepae8dccbib87","doi-asserted-by":"publisher","first-page":"7107","DOI":"10.1038\/s41598-020-62531-9","type":"journal-article","article-title":"Restoration of leg length and offset correlates with trochanteric pain syndrome in total hip arthroplasty","volume":"10","author":"Worlicek","year":"2020","journal-title":"Sci. Rep."},{"key":"mepae8dccbib88","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1080\/17453674.2020.1819729","type":"journal-article","article-title":"Custom-made 3D-printed cup-cage implants for complex acetabular revisions: evaluation of pre-planned versus achieved positioning and 1-year migration data in 10 patients","volume":"92","author":"Zampelis","year":"2021","journal-title":"Acta Orthop."},{"key":"mepae8dccbib89","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1111\/os.12099","type":"journal-article","article-title":"Three-dimensional computerized preoperative planning of total hip arthroplasty with high-riding dislocation developmental dysplasia of the hip","volume":"6","author":"Zeng","year":"2014","journal-title":"Orthop. Surg."},{"key":"mepae8dccbib90","doi-asserted-by":"publisher","DOI":"10.1177\/23094990211025325","type":"journal-article","article-title":"Does robotic assisted technology improve the accuracy of acetabular component positioning in patients with DDH?","volume":"29","author":"Zhou","year":"2021","journal-title":"J. Orthop. Surg."}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T10:21:20Z","timestamp":1785752480000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae8dcc"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,3]]},"references-count":90,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8,3]]},"published-print":{"date-parts":[[2026,8,3]]}},"URL":"https:\/\/doi.org\/10.1088\/1873-4030\/ae8dcc","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,3]]},"assertion":[{"value":"Centre of rotation in total hip arthroplasty: a critical review with emphasis on three-dimensional planning","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-01-29","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-08-03","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}