{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T08:08:48Z","timestamp":1788768528457,"version":"build-2803163510"},"reference-count":35,"publisher":"IOP Publishing","issue":"9","license":[{"start":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T00:00:00Z","timestamp":1788739200000},"content-version":"vor","delay-in-days":6,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T00:00:00Z","timestamp":1788739200000},"content-version":"tdm","delay-in-days":6,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Med. Eng. Phys."],"published-print":{"date-parts":[[2026,9,1]]},"DOI":"10.1088\/1873-4030\/ae9d18","type":"journal-article","created":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T22:47:46Z","timestamp":1787438866000},"page":"095002","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Fluid-structure interaction analysis of leaflet-annulus geometric mismatch under progressive annular dilation: a parametric study using a pediatric aortic geometry"],"prefix":"10.1088","volume":"147","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-1263-8590","authenticated-orcid":true,"given":"Jing","family":"Wang","sequence":"first","affiliation":[{"name":"Universiti Malaya"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunfei","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Transportation and Vehicle Engineering, Shandong University of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sivakumar","family":"Sivalingam","sequence":"additional","affiliation":[{"name":"National Heart Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2487-3933","authenticated-orcid":true,"given":"Yih Miin","family":"Liew","sequence":"additional","affiliation":[{"name":"Universiti Malaya"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Yusoff Mohd","family":"Ramdzan","sequence":"additional","affiliation":[{"name":"Pediatric and Congenital Heart Center, National Heart Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norazah","family":"Zahari","sequence":"additional","affiliation":[{"name":"Universiti Malaya"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming Chern","family":"Leong","sequence":"additional","affiliation":[{"name":"Pediatric and Congenital Heart Center, National Heart Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao Yun","family":"Xu","sequence":"additional","affiliation":[{"name":"Imperial College London"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2037-4213","authenticated-orcid":true,"given":"Einly","family":"Lim","sequence":"additional","affiliation":[{"name":"Universiti Malaya"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,9,7]]},"reference":[{"key":"mepae9d18bib1","doi-asserted-by":"publisher","first-page":"828","DOI":"10.1016\/j.amjcard.2006.04.022","type":"journal-article","article-title":"Progression of aortic dilation in children with a functionally normal bicuspid aortic valve","volume":"98","author":"Beroukhim","year":"2006","journal-title":"Am. J. Cardiol."},{"key":"mepae9d18bib2","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.682893","type":"journal-article","article-title":"The comparison of different constitutive laws and fiber architectures for the aortic valve on fluid\u2013structure interaction simulation","volume":"12","author":"Cai","year":"2021","journal-title":"Front. Physiol."},{"key":"mepae9d18bib3","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.jfluidstructs.2018.04.009","type":"journal-article","article-title":"A computational study of the three-dimensional fluid\u2013structure interaction of aortic valve","volume":"80","author":"Chen","year":"2018","journal-title":"J. Fluid Struct."},{"key":"mepae9d18bib4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2025.112532","type":"journal-article","article-title":"Comparison between the fluid\u2013structure interaction approach and the finite element method approach to analyze the leaflet flutter in bioprosthetic aortic valve","volume":"181","author":"Costa","year":"2025","journal-title":"J. Biomech."},{"key":"mepae9d18bib5","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1007\/s13239-020-00469-9","type":"journal-article","article-title":"Biomechanical assessment of bicuspid aortic valve phenotypes: a fluid\u2013structure interaction modelling approach","volume":"11","author":"de Oliveira","year":"2020","journal-title":"Cardiovasc. Eng. Tech."},{"key":"mepae9d18bib6","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1007\/s10439-020-02571-4","type":"journal-article","article-title":"Patient-specific bicuspid aortic valve biomechanics: a magnetic resonance imaging integrated fluid\u2013structure interaction approach","volume":"49","author":"Emendi","year":"2021","journal-title":"Ann. Biomed. Eng."},{"key":"mepae9d18bib7","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1080\/10255842.2012.688818","type":"journal-article","article-title":"Evaluation of a transient, simultaneous, arbitrary Lagrange\u2013Euler based multi-physics method for simulating the mitral heart valve","volume":"17","author":"Espino","year":"2014","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"mepae9d18bib8","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.euromechflu.2015.01.006","type":"journal-article","article-title":"Transient large strain contact modelling: a comparison of contact techniques for simultaneous fluid\u2013structure interaction","volume":"51","author":"Espino","year":"2015","journal-title":"Eur. J. Mech. B"},{"key":"mepae9d18bib9","doi-asserted-by":"publisher","first-page":"373","DOI":"10.3390\/jcdd10090373","type":"journal-article","article-title":"Prosthesis\u2013patient mismatch and aortic root enlargement: indications, techniques and outcomes","volume":"10","author":"Fazmin","year":"2023","journal-title":"J. Cardiovasc. Dev. Dis."},{"key":"mepae9d18bib10","author":"Ghosh","year":"2019","type":"other"},{"key":"mepae9d18bib11","doi-asserted-by":"publisher","DOI":"10.1115\/1.4038885","type":"journal-article","article-title":"Flow\u2013structure interaction simulations of the aortic heart valve at physiologic conditions: the role of tissue constitutive model","volume":"140","author":"Gilmanov","year":"2018","journal-title":"J. Biomech. Eng."},{"key":"mepae9d18bib12","doi-asserted-by":"publisher","first-page":"119","DOI":"10.3390\/fluids4030119","type":"journal-article","article-title":"Image-guided fluid-structure interaction simulation of transvalvular hemodynamics: quantifying the effects of varying aortic valve leaflet thickness","volume":"4","author":"Gilmanov","year":"2019","journal-title":"Fluids"},{"key":"mepae9d18bib13","doi-asserted-by":"publisher","first-page":"2392","DOI":"10.1016\/j.jbiomech.2012.07.017","type":"journal-article","article-title":"A general three-dimensional parametric geometry of the native aortic valve and root for biomechanical modeling","volume":"45","author":"Haj-Ali","year":"2012","journal-title":"J. Biomech."},{"key":"mepae9d18bib14","doi-asserted-by":"publisher","first-page":"1683","DOI":"10.1007\/s11517-016-1458-0","type":"journal-article","article-title":"Fluid\u2013structure interaction modeling of calcific aortic valve disease using patient-specific three-dimensional calcification scans","volume":"54","author":"Halevi","year":"2016","journal-title":"Med. Biol. Eng. Comput."},{"key":"mepae9d18bib15","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1007\/s00466-015-1166-x","type":"journal-article","article-title":"Dynamic and fluid\u2013structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models","volume":"55","author":"Hsu","year":"2015","journal-title":"Comput. Mech."},{"key":"mepae9d18bib16","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1007\/s00246-016-1555-8","type":"journal-article","article-title":"Measurement of aortic valve coaptation and effective height using echocardiography in patients with ventricular septal defects and aortic valve prolapse","volume":"38","author":"Iwashima","year":"2017","journal-title":"Pediatr. Cardiol."},{"key":"mepae9d18bib17","first-page":"TFEC-2018","type":"conference-proceedings","article-title":"Prediction of turbulent shear stresses through dysfunctional bileaflet mechanical heart valves using computational fluid dynamics","author":"Khalili","year":"2018"},{"key":"mepae9d18bib18","doi-asserted-by":"publisher","DOI":"10.1115\/1.4038329","type":"journal-article","article-title":"Fluid\u2013structure interaction models of bicuspid aortic valves: the effects of nonfused cusp angles","volume":"140","author":"Lavon","year":"2018","journal-title":"J. Biomech. Eng."},{"key":"mepae9d18bib19","doi-asserted-by":"publisher","first-page":"159","DOI":"10.32604\/cmes.2021.014580","type":"journal-article","article-title":"Bioprosthetic valve size selection to optimize aortic valve replacement surgical outcome: a fluid-structure interaction modeling study","volume":"127","author":"Li","year":"2021","journal-title":"Comput. Model. Eng. Sci."},{"key":"mepae9d18bib20","doi-asserted-by":"publisher","first-page":"ivae108","DOI":"10.1093\/icvts\/ivae108","type":"journal-article","article-title":"Three-dimensional modelling of aortic leaflet coaptation and load-bearing surfaces: in silico design of aortic valve neocuspidizations","volume":"39","author":"Mac\u00e9","year":"2024","journal-title":"Interdiscip. Cardiovasc. Thorac. Surg."},{"key":"mepae9d18bib21","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1007\/s13239-016-0285-7","type":"journal-article","article-title":"Fluid\u2013structure interaction study of transcatheter aortic valve dynamics using smoothed particle hydrodynamics","volume":"7","author":"Mao","year":"2016","journal-title":"Cardiovasc. Eng. Technol."},{"key":"mepae9d18bib22","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1016\/j.jtcvs.2012.01.080","type":"journal-article","article-title":"Aortic root numeric model: annulus diameter prediction of effective height and coaptation in post\u2013aortic valve repair","volume":"145","author":"Marom","year":"2013","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"mepae9d18bib23","first-page":"287","type":"journal-article","article-title":"Aortic valve mechanics\u2013Part I: material properties of natural porcine aortic valves","volume":"2","author":"Missirlis","year":"1978","journal-title":"J. Bioeng."},{"key":"mepae9d18bib24","doi-asserted-by":"publisher","first-page":"i96","DOI":"10.1093\/europace\/euaa398","type":"journal-article","article-title":"Fully coupled dynamic simulations of bioprosthetic aortic valves based on an embedded strategy for fluid\u2013structure interaction with contact","volume":"23","author":"Nestola","year":"2021","journal-title":"Europace"},{"key":"mepae9d18bib25","doi-asserted-by":"publisher","first-page":"e3792","DOI":"10.1002\/cnm.3792","type":"journal-article","article-title":"Three\u2010dimensional fluid\u2013structure interaction simulation of the Wheatley aortic valve","volume":"40","author":"Oliveira","year":"2024","journal-title":"Int. J. Numer. Method Biomed. Eng."},{"key":"mepae9d18bib26","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2024.108191","type":"journal-article","article-title":"Patient-specific analysis of bicuspid aortic valve hemodynamics using a fully coupled fluid-structure interaction model","volume":"172","author":"Qin","year":"2024","journal-title":"Comput. Biol. Med."},{"key":"mepae9d18bib27","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1136\/heartjnl-2017-311582","type":"journal-article","article-title":"Bioprosthetic aortic valve durability in the era of transcatheter aortic valve implantation","volume":"104","author":"Salaun","year":"2018","journal-title":"Heart"},{"key":"mepae9d18bib28","doi-asserted-by":"publisher","first-page":"328","DOI":"10.3390\/bioengineering12040328","type":"journal-article","article-title":"Virtual Therapy Planning of Aortic Valve Replacement for Preventing Patient-Prosthesis Mismatch","volume":"12","author":"Schafstedde","year":"2025","journal-title":"Bioengineering"},{"key":"mepae9d18bib29","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1186\/s13019-021-01636-2","type":"journal-article","article-title":"Aortic valve replacement in pediatric patients: 30 years single center experience","volume":"16","author":"Schlein","year":"2021","journal-title":"J. Cardiothorac. Surg."},{"key":"mepae9d18bib30","first-page":"653","type":"journal-article","article-title":"High speed cine-radiographic study of aortic valve leaflet motion","volume":"2","author":"Thubrikar","year":"1993","journal-title":"J. Heart Valve Dis."},{"key":"mepae9d18bib31","doi-asserted-by":"publisher","first-page":"746","DOI":"10.4244\/EIJ-D-23-00456","type":"journal-article","article-title":"Long-term outcomes of measured and predicted prosthesis-patient mismatch following transcatheter aortic valve replacement","volume":"19","author":"Tomii","year":"2023","journal-title":"EuroIntervention"},{"key":"mepae9d18bib32","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1111\/jocs.12345","type":"journal-article","article-title":"Patient\u2013prosthesis mismatch in patients undergoing bioprosthetic aortic valve implantation increases risk of reoperation for structural valve deterioration","volume":"29","author":"Urso","year":"2014","journal-title":"J. Card. Surg."},{"key":"mepae9d18bib33","doi-asserted-by":"publisher","first-page":"64","DOI":"10.4244\/AIJ-D-19-00005","type":"journal-article","article-title":"Impact of transcatheter aortic valve size on leaflet stresses: implications for durability and optimal grey zone sizing: transcatheter valve size impacts leaflet stresses","volume":"6","author":"Xuan","year":"2020","journal-title":"AsiaIntervention"},{"key":"mepae9d18bib34","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.716015","type":"journal-article","article-title":"A fluid\u2013structure interaction study of different bicuspid aortic valve phenotypes throughout the cardiac cycle","volume":"12","author":"Yan","year":"2021","journal-title":"Front. Physiol."},{"key":"mepae9d18bib35","doi-asserted-by":"publisher","first-page":"e3865","DOI":"10.1002\/cnm.3865","type":"journal-article","article-title":"Fluid\u2013structure interaction analysis of a healthy aortic valve and its surrounding haemodynamics","volume":"40","author":"Yin","year":"2024","journal-title":"Int. J. Numer. Method Biomed. Eng."}],"container-title":["Medical Engineering &amp; Physics"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T07:25:47Z","timestamp":1788765947000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/1873-4030\/ae9d18"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":35,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9,7]]},"published-print":{"date-parts":[[2026,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/1873-4030\/ae9d18","relation":{},"ISSN":["1350-4533","1873-4030"],"issn-type":[{"value":"1350-4533","type":"print"},{"value":"1873-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,1]]},"assertion":[{"value":"Fluid-structure interaction analysis of leaflet-annulus geometric mismatch under progressive annular dilation: a parametric study using a pediatric aortic geometry","name":"article_title","label":"Article Title"},{"value":"Medical Engineering & Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-05","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-08-21","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-07","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}