{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T13:17:35Z","timestamp":1790255855149,"version":"4.1.0"},"reference-count":30,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2019,12,19]],"date-time":"2019-12-19T00:00:00Z","timestamp":1576713600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"},{"start":{"date-parts":[[2019,12,19]],"date-time":"2019-12-19T00:00:00Z","timestamp":1576713600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2020,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:bold>\n                     <jats:italic>Objective:<\/jats:italic>\n                  <\/jats:bold> To evaluate the performance of five different types of textiles as band electrodes for calf bioimpedance measurements in comparison with conventional spot Ag\/AgCl electrodes. <jats:bold>\n                     <jats:italic>Approach:<\/jats:italic>\n                  <\/jats:bold> Calf bioimpedance measurements were performed in 10 healthy volunteers with five different textile materials cut into bands and Ag\/AgCl spot electrodes as a baseline. Collected bioimpedance data were analyzed in terms of precision, fit error and presence of measurement artifacts. Each textile material was also evaluated for participant comfort. <jats:bold>\n                     <jats:italic>Main Results:<\/jats:italic>\n                  <\/jats:bold> Bioimpedance values for spot electrodes were higher at low frequencies as compared with band electrodes but not at high frequencies. This suggests that spot electrodes have frequency dependent current distributions that adversely impact their use for volume measurements and band electrodes are preferable. The SMP130T-B fabric had the highest precision and the lowest best fit error to the Cole model of the tested textile materials. However, it was the least comfortable textile and most expensive. The Stretch material performed slightly worse than the SMP130T-B fabric, but was half the cost and the most comfortable. <jats:bold>\n                     <jats:italic>Significance:<\/jats:italic>\n                  <\/jats:bold> These results suggest that there are suitable textile materials for use as dry, band electrodes for calf bioimpedance measurements and that these band electrodes enable greater current uniformity. These textiles could be integrated into a compression sock for remote monitoring of diseases such as Congestive Heart Failure.<\/jats:p>","DOI":"10.1088\/2057-1976\/ab5b02","type":"journal-article","created":{"date-parts":[[2019,11,25]],"date-time":"2019-11-25T16:15:15Z","timestamp":1574698515000},"page":"015010","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":11,"title":["Textile band electrodes as an alternative to spot Ag\/AgCl electrodes for calf bioimpedance measurements"],"prefix":"10.1088","volume":"6","author":[{"given":"Ke","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dylan","family":"Zelko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6161-8854","authenticated-orcid":false,"given":"Maggie","family":"Delano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2019,12,19]]},"reference":[{"key":"bpexab5b02bib1","doi-asserted-by":"publisher","DOI":"10.1016\/c2012-0-06951-7","author":"Grimnes","year":"2015","edition":"3rd edn"},{"key":"bpexab5b02bib2","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1177\/0884533614568155","article-title":"Bioimpedance at the bedside: current applications, limitations, and opportunities","volume":"30","author":"Mulasi","year":"2015","journal-title":"Nutrition in Clinical Practice: Official Publication of the American Society for Parenteral and Enteral Nutrition"},{"key":"bpexab5b02bib3","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1016\/j.medengphy.2008.06.009","article-title":"Body fluid volumes measurements by impedance: a review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods","volume":"30","author":"Jaffrin","year":"2008","journal-title":"Medical Engineering and Physics"},{"key":"bpexab5b02bib4","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1109\/51.32403","article-title":"Fundamentals of impedance cardiography","volume":"8","author":"Patterson","year":"1989","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"bpexab5b02bib5","doi-asserted-by":"publisher","first-page":"2171","DOI":"10.1088\/0967-3334\/36\/10\/2171","article-title":"Estimation of body fluids with bioimpedance spectroscopy: state of the art methods and proposal of novel methods","volume":"36","author":"Buendia","year":"2015","journal-title":"Physiol. Meas."},{"key":"bpexab5b02bib6","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1093\/ajcn\/85.1.80","article-title":"A whole-body model to distinguish excess fluid from the hydration of major body tissues","volume":"85","author":"Chamney","year":"2007","journal-title":"The American Journal of Clinical Nutrition"},{"key":"bpexab5b02bib7","doi-asserted-by":"publisher","first-page":"29","DOI":"10.5617\/jeb.298","article-title":"Description of corrections on electrode polarization impedance using isopotential interface factor","volume":"3","author":"G\u00f3mez-S\u00e1nchez","year":"2012","journal-title":"Journal of Electrical Bioimpedance"},{"key":"bpexab5b02bib8","doi-asserted-by":"publisher","first-page":"2353","DOI":"10.1109\/TBME.2016.2641958","article-title":"Wearable vector electrical bioimpedance system to assess knee joint health","volume":"64","author":"Hersek","year":"2017","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexab5b02bib9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TBME.2019.2927807","article-title":"Robust longitudinal ankle edema assessment using wearable bioimpedance spectroscopy","author":"Mabrouk","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexab5b02bib10","doi-asserted-by":"publisher","first-page":"S503","DOI":"10.1088\/0967-3334\/29\/6\/S42","article-title":"A method for the estimation of hydration state during hemodialysis using a calf bioimpedance technique","volume":"29","author":"Zhu","year":"2008","journal-title":"Physiol. Meas."},{"key":"bpexab5b02bib11","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.1007\/s11517-013-1064-3","article-title":"Monitoring intracellular, interstitial, and intravascular volume changes during fluid management procedures","volume":"51","author":"Montgomery","year":"2013","journal-title":"Med. Biol. Eng. Comput."},{"key":"bpexab5b02bib12","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/aaf277","article-title":"Evaluating calf bioimpedance measurements for fluid overload management in a controlled environment","volume":"39","author":"Delano","year":"2018","journal-title":"Physiol. Meas."},{"key":"bpexab5b02bib13","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.irbm.2016.02.005","article-title":"The complicating effects of patient limb position on the development of a localised impedimetric-based hydrational index for the remote monitoring of home-based dialysis patients","volume":"37","author":"Montalibet","year":"2016","journal-title":"IRBM"},{"key":"bpexab5b02bib14","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1088\/0967-3334\/35\/6\/917","article-title":"Bioelectrical impedance spectroscopy as a fluid management system in heart failure","volume":"35","author":"Weyer","year":"2014","journal-title":"Physiol. Meas."},{"key":"bpexab5b02bib15","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1007\/978-3-642-03885-3_148","article-title":"Monitoring of body fluid in patients with chronic heart failure using Bioimpedance\u2014Spectroscopy","author":"Beckmann","year":"2009"},{"key":"bpexab5b02bib16","doi-asserted-by":"publisher","first-page":"1867","DOI":"10.1109\/iembs.2011.6090530","article-title":"Skin\u2014electrode contact area in electrical bioimpedance spectroscopy. Influence in total body composition assessment","volume":"2011","author":"Marquez","year":"2011","journal-title":"2011 Annual International Conf. of the IEEE Engineering in Medicine and Biology Society"},{"key":"bpexab5b02bib17","doi-asserted-by":"publisher","first-page":"5910","DOI":"10.1109\/embc.2018.8513563","article-title":"Electrode placement for calf bioimpedance measurements during hemodialysis","author":"Delano","year":"2018"},{"key":"bpexab5b02bib18","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1088\/0967-3334\/31\/2\/009","article-title":"Characterization of textile electrodes and conductors using standardized measurement setups","volume":"31","author":"Beckmann","year":"2010","journal-title":"Physiol. Meas."},{"key":"bpexab5b02bib19","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1088\/0967-3334\/35\/6\/1181","article-title":"The IMPACT shirt: textile integrated and portable impedance cardiography","volume":"35","author":"Ulbrich","year":"2014","journal-title":"Physiol. Meas."},{"key":"bpexab5b02bib20","doi-asserted-by":"publisher","first-page":"6385","DOI":"10.1109\/iembs.2010.5627305","article-title":"Textile electrode straps for wrist-to-ankle bioimpedance measurements for Body Composition analysis. Initial validation & experimental results","author":"Marquez","year":"2010"},{"key":"bpexab5b02bib21","doi-asserted-by":"publisher","first-page":"15001","DOI":"10.1088\/2057-1976\/aaea59","article-title":"Dry electrodes for bioimpedance measurements-design, characterization and comparison","volume":"5","author":"Kusche","year":"2019","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexab5b02bib22","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1109\/bhi.2018.8333370","article-title":"Preliminary results on transthoracic bioimpedance measurements with a variety of electrode materials","author":"Reljin","year":"2018"},{"key":"bpexab5b02bib23","doi-asserted-by":"publisher","first-page":"1478","DOI":"10.1109\/embc.2013.6609791","article-title":"Characterization of dry biopotential electrodes","author":"Xie","year":"2013"},{"key":"bpexab5b02bib24","doi-asserted-by":"publisher","first-page":"1224","DOI":"10.1109\/JBHI.2016.2628766","article-title":"A handheld and textile-enabled bioimpedance system for ubiquitous body composition analysis. An initial functional validation","volume":"21","author":"Ferreira","year":"2017","journal-title":"IEEE Journal of Biomedical and Health Informatics"},{"key":"bpexab5b02bib25","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1101\/SQB.1940.008.01.013","article-title":"Permeability and impermeability of cell membranes for ions","volume":"8","author":"Cole","year":"1940","journal-title":"Cold Spring Harbor Symp. Quant. Biol."},{"key":"bpexab5b02bib26","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1002\/mus.10048","article-title":"Localized bioimpedance analysis in the evaluation of neuromuscular disease","volume":"25","author":"Rutkove","year":"2002","journal-title":"Muscle & Nerve"},{"key":"bpexab5b02bib27","doi-asserted-by":"publisher","first-page":"1719","DOI":"10.3390\/s18061719","article-title":"Analysis of consistency of transthoracic bioimpedance measurements acquired with dry carbon black PDMS electrodes, adhesive electrodes, and wet textile electrodes","volume":"18","author":"Posada-Quintero","year":"2018","journal-title":"Sensors"},{"key":"bpexab5b02bib28","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1088\/0967-3334\/19\/2\/012","article-title":"A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy","volume":"19","author":"Scharfetter","year":"1998","journal-title":"Physiol. Meas."},{"key":"bpexab5b02bib29","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1088\/0967-3334\/30\/7\/004","article-title":"Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatch","volume":"30","author":"Bog\u00f3nez-Franco","year":"2009","journal-title":"Physiol. Meas."},{"key":"bpexab5b02bib30","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.measurement.2018.07.010","article-title":"Evaluation of ImpediMed SFB7 BIS device for low-impedance measurements","volume":"129","author":"Freeborn","year":"2018","journal-title":"Measurement: Journal of the International Measurement Confederation"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,24]],"date-time":"2021-11-24T23:34:17Z","timestamp":1637796857000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab5b02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,19]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12,19]]},"published-print":{"date-parts":[[2020,1,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ab5b02","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,19]]},"assertion":[{"value":"Textile band electrodes as an alternative to spot Ag\/AgCl electrodes for calf bioimpedance measurements","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2019 IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2019-09-13","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-11-22","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-12-19","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}