{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T00:42:56Z","timestamp":1773276176751,"version":"3.50.1"},"reference-count":40,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2020,1,31]],"date-time":"2020-01-31T00:00:00Z","timestamp":1580428800000},"content-version":"vor","delay-in-days":30,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2020,1,31]],"date-time":"2020-01-31T00:00:00Z","timestamp":1580428800000},"content-version":"tdm","delay-in-days":30,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100010447","name":"Ministry of Research, Technology and Higher Education of the Republic of Indonesia","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100010447","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2020,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study was to evaluate dose reduction and resulting image quality of a new synthetic thyroid shield based on silicon rubber (SR)\u2013lead (Pb) composites and compare to tungsten paper (WP) and a Radibabarrier thyroid shields in CT examination of the neck. The synthetic SR-Pb thyroid shield had a Pb percentage from 0 to 5 wt% and a thickness of 0.6 cm. Scanning on the neck of an anthropomorphic phantom was performed with and without the SR-Pb, WP, and Radibarrier thyroid shields. The thyroid shields were placed directly on the neck surface. The thyroid dose was measured using radiophoto-luminescence (RPL) detectors. Image quality was characterized by consistency of the Hounsfield unit (HU) on the areas of anterior, posterior and lateral of the neck phantom. Detailed evaluation of the image quality was employed by image subtraction. It was found that the thyroid dose at the surface decreased with an increase of Pb percentage in the SR-Pb shield. The thyroid dose reduction was 34% for a Pb percentage of 5 wt%. The reduction of the dose using WP and Radibarrier were 36% and 67%, respectively. The dose reduction when using the WP and Radibarrier was higher than when using the SR-Pb 5 wt% thyroid shield. However the existence of artifact in the WP and the Radibarrier reduced the image quality, indicated by a significant change of HU, i.e. the increases of HU in the posterior area were 77% for the WP and 553% for the Radibarrier. The SR-Pb shield produced only a very small artifact, resulting in an increase of HU in the posterior area of only 9%. The SR-Pb shield is suitable in the daily clinical setting for thyroid dose reduction in CT examinations while maintaining image quality.<\/jats:p>","DOI":"10.1088\/2057-1976\/ab6ed1","type":"journal-article","created":{"date-parts":[[2020,1,22]],"date-time":"2020-01-22T18:00:36Z","timestamp":1579716036000},"page":"015029","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["An artifact-free thyroid shield in CT examination: a phantom study"],"prefix":"10.1088","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7119-9633","authenticated-orcid":false,"given":"Heri","family":"Sutanto","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yulia","family":"Irdawati","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0156-6797","authenticated-orcid":false,"given":"Choirul","family":"Anam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshioh","family":"Fujibuchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geoff","family":"Dougherty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3438-0369","authenticated-orcid":false,"given":"Eko","family":"Hidayanto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zaenal","family":"Arifin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johny Wahyuadi","family":"Soedarsono","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"family":"Bahrudin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2020,1,31]]},"reference":[{"key":"bpexab6ed1bib1","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1002\/acm2.12476","type":"journal-article","article-title":"An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images","volume":"19","author":"Anam","year":"2018","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexab6ed1bib2","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1259\/bjr\/75960844","type":"journal-article","article-title":"Patient dose reduction in CT","volume":"78","author":"Lewis","year":"2005","journal-title":"Br. J. Radiol."},{"key":"bpexab6ed1bib3","doi-asserted-by":"publisher","first-page":"2334","DOI":"10.1007\/s00330-006-0217-2","type":"journal-article","article-title":"Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality","volume":"16","author":"Geleijns","year":"2006","journal-title":"Eur. J. Radiol."},{"key":"bpexab6ed1bib4","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","type":"journal-article","article-title":"Computed tomography\u2014an increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"N. Engl. J. Med."},{"key":"bpexab6ed1bib5","doi-asserted-by":"publisher","first-page":"213","DOI":"10.2967\/jnmt.106.037846","type":"journal-article","article-title":"Principles of CT: radiation dose and image quality","volume":"35","author":"Goldman","year":"2007","journal-title":"Nucl. Med. Technol."},{"key":"bpexab6ed1bib6","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1007\/s11547-009-0469-4","type":"journal-article","article-title":"Dose reduction in multislice CT by means of bismuth shields: results of in vivo measurements and computed evaluation","volume":"115","author":"Catuzzo","year":"2010","journal-title":"Radiol. Med."},{"key":"bpexab6ed1bib7","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1097\/RCT.0b013e3181a776ff","type":"journal-article","article-title":"Radiation dose to the thyroid gland and breast from multidetector computed tomography of the cervical spine: does bismuth shielding with and without a cervical collar reduce dose?","volume":"33","author":"Gunn","year":"2009","journal-title":"J. Comput. Assist. Tomogr."},{"key":"bpexab6ed1bib8","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1093\/rpd\/ncp278","type":"journal-article","article-title":"Dose reduction in CT using bismuth shielding: measurements and Monte Carlo simulations","volume":"138","author":"Chang","year":"2009","journal-title":"Radiat. Prot. Dosimetry."},{"key":"bpexab6ed1bib9","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1667\/RR1859.1","type":"journal-article","article-title":"Slowing the increase in the population dose resulting from CT scans slowing the increase in the population dose resulting from CT scans","volume":"174","author":"Brenner","year":"2010","journal-title":"Radiat. Res. Soc."},{"key":"bpexab6ed1bib10","doi-asserted-by":"publisher","first-page":"935","DOI":"10.2214\/AJR.11.6460","type":"journal-article","article-title":"A comprehensive approach to CT radiation dose reduction: one institution\u2019s experience","volume":"197","author":"Antypas","year":"2011","journal-title":"Am. J. Roentgenol."},{"key":"bpexab6ed1bib11","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.sjbs.2016.01.011","type":"journal-article","article-title":"Patient radiation biological risk in computed tomography angiography procedure","volume":"24","author":"Alkhorayef","year":"2017","journal-title":"Saudi J. Biol. Sci."},{"key":"bpexab6ed1bib12","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.radphyschem.2018.08.019","type":"journal-article","article-title":"Estimation of radiation-induced cataract and cancer risks during routine CT head procedures","volume":"155","author":"Alkhorayef","year":"2019","journal-title":"Radiat. Phys. Chem."},{"key":"bpexab6ed1bib13","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1093\/rpd\/ncr429","type":"journal-article","article-title":"Development of a database of organ doses for paediatric and young adult CT scans in the United Kingdom","volume":"150","author":"Kim","year":"2012","journal-title":"Radiat. Prot. Dosimetry."},{"key":"bpexab6ed1bib14","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1093\/jrr\/rru019","type":"journal-article","article-title":"Classification of radiation effects for dose limitation purposes: history, current situation and future prospects","volume":"55","author":"Hamada","year":"2014","journal-title":"Radiat. Res."},{"key":"bpexab6ed1bib15","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1177\/0194599814542588","type":"journal-article","article-title":"Risk of malignancy associated with head and neck CT in children: a systematic review","volume":"151","author":"Chen","journal-title":"Otolaryngol. Head. Neck. Surg."},{"key":"bpexab6ed1bib16","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1051\/radiopro\/2013072","type":"journal-article","article-title":"An overview of exposure parameters, dose measurements and strategies for dose reduction in pediatric CT examinations","volume":"49","author":"Akhlaghi","year":"2013","journal-title":"Radioprotection"},{"key":"bpexab6ed1bib17","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.apradiso.2016.03.018","type":"journal-article","article-title":"Assessment of breast absorbed doses during thoracic computed tomography scan to evaluate the effectiveness of bismuth shielding","volume":"117","author":"Alonso","year":"2016","journal-title":"Appl. Radiat. Isot."},{"key":"bpexab6ed1bib18","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.2214\/AJR.11.7445","type":"journal-article","article-title":"Organ-based dose current modulation and thyroid shields: techniques of radiation dose reduction for neck CT","volume":"198","author":"Hoang","year":"2012","journal-title":"Am. J. Roentgenol."},{"key":"bpexab6ed1bib19","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1093\/rpd\/ncv059","type":"journal-article","article-title":"Assessment of patient dose reduction by Bismuth shielding in CT using measurements, GEANT4 and MCNPX simulations","volume":"165","author":"Mendes","year":"2015","journal-title":"Radiat. Prot. Dosimetry."},{"key":"bpexab6ed1bib20","doi-asserted-by":"publisher","first-page":"7","DOI":"10.17140\/ROJ-2-113","type":"journal-article","article-title":"The current use and effectiveness of bismuth shielding in computed tomography: a systematic review","volume":"2","author":"Lawrence","year":"2017","journal-title":"Radiol. Open. J."},{"key":"bpexab6ed1bib21","doi-asserted-by":"publisher","first-page":"727","DOI":"10.3174\/ajnr.A0891","type":"journal-article","article-title":"Balancing radiation dose and image quality: clinical applications of neck volume CT","volume":"29","author":"Russell","year":"2008","journal-title":"Am. J. Neuroradiol."},{"key":"bpexab6ed1bib22","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1007\/s00247-014-3084-z","type":"journal-article","article-title":"Pros and cons of organ shielding for CT imaging","volume":"44","author":"Samei","year":"2014","journal-title":"Pediatr. Radiol."},{"key":"bpexab6ed1bib23","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1088\/1361-6498\/ab23cc","type":"journal-article","article-title":"Assessment of patient dose and noise level of clinical CT images: automated measurements","volume":"39","author":"Anam","year":"2019","journal-title":"J. Radiol. Prot."},{"key":"bpexab6ed1bib24","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1080\/02841850600702150","type":"journal-article","article-title":"Radiation dose reduction to breast and thyroid during MDCT: effectiveness of an in-plane bismuth shield","volume":"47","author":"Hohl","year":"2009","journal-title":"Acta. Radiol."},{"key":"bpexab6ed1bib25","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1093\/rpd\/ncr336","type":"journal-article","article-title":"Dose reduction using bismuth shielding during paediatric CT examinations in Slovakia","volume":"147","author":"Gbelcov\u00e1","year":"2011","journal-title":"Radiat. Prot. Dosimetry"},{"key":"bpexab6ed1bib26","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1093\/rpd\/ncr336","type":"journal-article","article-title":"Dose reduction using bismuth shielding during paediatric CT examinations in slov","volume":"147","author":"Nikodemova","year":"2011","journal-title":"Radiat. Prot. Dosimetry."},{"key":"bpexab6ed1bib27","doi-asserted-by":"publisher","first-page":"611","DOI":"10.2214\/AJR.10.4955","type":"journal-article","article-title":"Comparative analysis of radiation dose and image quality between thyroid shielding and unshielding during CT examination of the neck","volume":"196","author":"Lee","year":"2011","journal-title":"Am. J. Roentgenol."},{"key":"bpexab6ed1bib28","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1093\/rpd\/ncw007","type":"journal-article","article-title":"Paediatric neck multidetector computed tomography: the effect of bismuth shielding on thyroid dose and image quality","volume":"173","author":"Inkoom","year":"2017","journal-title":"Radiat. Prot. Dosimetry."},{"key":"bpexab6ed1bib29","doi-asserted-by":"publisher","first-page":"289","DOI":"10.18869\/acadpub.ijrr.16.3.289","type":"journal-article","article-title":"Volume computed tomography dose index (CTDIvol) and size-specific dose estimate (SSDE) for tube current modulation (TCM) in CT scanning","volume":"16","author":"Anam","year":"2018","journal-title":"Int. J. Radiat. Res."},{"key":"bpexab6ed1bib30","doi-asserted-by":"publisher","first-page":"592","DOI":"10.2214\/AJR.12.8580","type":"journal-article","article-title":"Relating noise to image quality indicators in CT examinations with tube current modulation","volume":"200","author":"Solomon","year":"2013","journal-title":"Am. J. Roentgenol."},{"key":"bpexab6ed1bib31","doi-asserted-by":"publisher","first-page":"2520","DOI":"10.1007\/s00330-014-3309-4","type":"journal-article","article-title":"Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality","volume":"24","author":"Papadakis","year":"2014","journal-title":"Eur. J. Radiol."},{"key":"bpexab6ed1bib32","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1148\/radiol.2492071430","type":"journal-article","article-title":"Thyroid shields versus z-axis automatic tube current modulation for dose reduction at neck CT","volume":"249","author":"Leswick","year":"2008","journal-title":"Radiology"},{"key":"bpexab6ed1bib33","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.colsurfa.2016.04.058","type":"journal-article","article-title":"X-ray protection, surface chemistry and rheology of ball-milled submicron Gd2O3 aqueous suspension","volume":"501","author":"La","year":"2016","journal-title":"Colloids Surf. A"},{"key":"bpexab6ed1bib34","doi-asserted-by":"publisher","first-page":"856","DOI":"10.1016\/j.jacr.2012.05.008","type":"journal-article","article-title":"CT bismuth breast shielding: Is it time to make your own decision?","volume":"9","author":"Zhang","year":"2012","journal-title":"J. Am. Coll. Radiol."},{"key":"bpexab6ed1bib35","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1088\/1361-6498\/ab2f3e","type":"journal-article","article-title":"Development of a novel artifact-free eye shield based on silicon rubber-lead composition in the CT examination on the head","volume":"39","author":"Irdawati","year":"2019","journal-title":"J. Radiol. Prot."},{"key":"bpexab6ed1bib36","doi-asserted-by":"publisher","first-page":"1769","DOI":"10.1118\/1.3689810","type":"journal-article","article-title":"Robust calculation of effective atomic numbers: the Auto-Zeff software","volume":"39","author":"Taylor","year":"2012","journal-title":"Med. Phys."},{"key":"bpexab6ed1bib37","doi-asserted-by":"publisher","first-page":"3663","DOI":"10.1016\/j.polymer.2013.05.014","type":"journal-article","article-title":"A novel approach to electrically and thermally conductive elastomers using graphene","volume":"54","author":"Araby","year":"2013","journal-title":"Polymer"},{"key":"bpexab6ed1bib38","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.compscitech.2013.12.004","type":"journal-article","article-title":"Using a green method to develop graphene oxide\/elastomers nanocomposites with combination of high barrier and mechanical performance","volume":"92","author":"Kang","year":"2014","journal-title":"Compos. Sci. Technol."},{"key":"bpexab6ed1bib39","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/j.compscitech.2018.08.022","type":"journal-article","article-title":"Highly sensitive and stretchable graphene-silicone rubber composites for strain sensing","volume":"167","author":"Yang","year":"2018","journal-title":"Compos. Sci. Technol."},{"key":"bpexab6ed1bib40","doi-asserted-by":"publisher","first-page":"12306","DOI":"10.1007\/s10854-018-9344-1","type":"journal-article","article-title":"Efficient, flexible and lead-free composite based on room temperature vulcanizing silicone rubber\/W\/Bi2O3 for gamma ray shielding application","volume":"29","author":"Atashi","year":"2018","journal-title":"J. Mater. Sci., Mater. Electron."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T15:26:40Z","timestamp":1768663600000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab6ed1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,1]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,1,31]]},"published-print":{"date-parts":[[2020,1,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ab6ed1","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,1]]},"assertion":[{"value":"An artifact-free thyroid shield in CT examination: a phantom study","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2020 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2019-11-13","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-01-22","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-01-31","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}