{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T14:00:29Z","timestamp":1768744829398,"version":"3.49.0"},"reference-count":50,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2020,5,11]],"date-time":"2020-05-11T00:00:00Z","timestamp":1589155200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2020,5,11]],"date-time":"2020-05-11T00:00:00Z","timestamp":1589155200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Canon America Medical Systems"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2020,7,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Background:<\/jats:italic>\n                    3D printed patient-specific coronary models have the ability to enable repeatable benchtop experiments under controlled blood flow conditions. This approach can be applied to CT-derived patient geometries to emulate coronary flow and related parameters such as Fractional Flow Reserve (FFR).\n                    <jats:italic>Methods:<\/jats:italic>\n                    This study uses 3D printing to compare such benchtop FFR results with a non-invasive CT-FFR research software algorithm and catheter based invasive FFR (I-FFR) measurements. Fifty-two patients with a clinical indication for I-FFR underwent a research Coronary CT Angiography (CCTA) prior to catheterization. CT images were used to measure CT-FFR and to generate patient-specific 3D printed models of the aortic root and three main coronary arteries. Each patient-specific model was connected to a programmable pulsatile pump and benchtop FFR (B-FFR) was derived from pressures measured proximal and distal to coronary stenosis using pressure transducers. B-FFR was measured for two coronary outflow rates (\u2018normal\u2019, 250 ml min\n                    <jats:sup>\u22121<\/jats:sup>\n                    ; and \u2018hyperemic\u2019, 500 ml min\n                    <jats:sup>\u22121<\/jats:sup>\n                    ) by adjusting the model\u2019s distal coronary resistance.\n                    <jats:italic>Results:<\/jats:italic>\n                    Pearson correlations and ROC AUC were calculated using invasive I-FFR as reference. The Pearson correlation factor of CT-FFR and B-FFR-500 was 0.75 and 0.71, respectively. Areas under the ROCs for CT-FFR and B-FFR-500 were 0.80 (95%CI: 0.70\u20130.87) and 0.81 (95%CI: 0.64\u20130.91) respectively.\n                    <jats:italic>Conclusion:<\/jats:italic>\n                    Benchtop flow simulations with 3D printed models provide the capability to measure pressure changes at any location in the model, for ultimately emulating the FFR at several simulated physiological blood flow conditions.\n                    <jats:italic>Clinical Trial Registration:<\/jats:italic>\n                    <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/clinicaltrials.gov\/show\/NCT03149042\" xlink:type=\"simple\">https:\/\/clinicaltrials.gov\/show\/NCT03149042<\/jats:ext-link>\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ab8f6e","type":"journal-article","created":{"date-parts":[[2020,5,1]],"date-time":"2020-05-01T18:30:28Z","timestamp":1588357828000},"page":"045007","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":9,"title":["Patient-specific 3D-printed coronary models based on coronary computed tomography angiography volumes to investigate flow conditions in coronary artery disease"],"prefix":"10.1088","volume":"6","author":[{"given":"Kelsey N","family":"Sommer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lauren M","family":"Shepard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dimitrios","family":"Mitsouras","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vijay","family":"Iyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erin","family":"Angel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael F","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank J","family":"Rybicki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kanako Kunishima","family":"Kumamaru","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Umesh C","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abhinay","family":"Reddy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichiro","family":"Fujimoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7049-0592","authenticated-orcid":false,"given":"Ciprian N","family":"Ionita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2020,5,11]]},"reference":[{"key":"bpexab8f6ebib1","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1161\/01.CIR.55.2.329","type":"journal-article","article-title":"Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation","volume":"55","author":"Brown","year":"1977","journal-title":"Circulation"},{"key":"bpexab8f6ebib2","doi-asserted-by":"publisher","first-page":"1344","DOI":"10.1097\/00006123-200006000-00012","type":"journal-article","article-title":"Prevention and treatment of thromboembolic and ischemic complications associated with endovascular procedures: I. Pathophysiological and pharmacological features","volume":"46","author":"Qureshi","year":"2000","journal-title":"Neurosurgery"},{"key":"bpexab8f6ebib3","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1093\/ehjci\/jez160","type":"journal-article","article-title":"Diagnostic accuracy of 3D deep-learning-based fully automated estimation of patient-level minimum fractional flow reserve from coronary computed tomography angiography","volume":"21","author":"Kumamaru","year":"2020","journal-title":"European Heart Journal - Cardiovascular Imaging"},{"key":"bpexab8f6ebib4","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.ejrad.2019.04.011","type":"journal-article","article-title":"Diagnostic performance of fractional flow reserve derived from coronary CT angiography for detection of lesion-specific ischemia: a multi-center study and meta-analysis","volume":"116","author":"Tang","year":"2019","journal-title":"Eur. J. Radiol."},{"key":"bpexab8f6ebib5","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1016\/j.ahj.2014.03.003","type":"journal-article","article-title":"PROspective multicenter imaging study for evaluation of chest pain: rationale and design of the PROMISE trial","volume":"167","author":"Douglas","year":"2014","journal-title":"Am. Heart J."},{"key":"bpexab8f6ebib6","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1152\/japplphysiol.00752.2015","type":"journal-article","article-title":"A machine-learning approach for computation of fractional flow reserve from coronary computed tomography","volume":"121","author":"Itu","year":"2016","journal-title":"J. Appl. Physiol."},{"key":"bpexab8f6ebib7","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.conctc.2018.08.001","type":"journal-article","article-title":"Factors associated with clinical trials that fail and opportunities for improving the likelihood of success: a review","volume":"11","author":"Fogel","year":"2018","journal-title":"Contemporary Clinical Trials Communications"},{"key":"bpexab8f6ebib8","doi-asserted-by":"publisher","first-page":"2540","DOI":"10.1016\/j.jbiomech.2016.01.002","type":"journal-article","article-title":"Uncertainty quantification in coronary blood flow simulations: impact of geometry, boundary conditions and blood viscosity","volume":"49","author":"Sankaran","year":"2016","journal-title":"J. Biomech."},{"key":"bpexab8f6ebib9","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1080\/10255842.2013.822490","type":"journal-article","article-title":"Isolated effect of geometry on mitral valve function for in silico model development","volume":"18","author":"Siefert","year":"2015","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"bpexab8f6ebib10","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1097\/MAT.0b013e3182396847","type":"journal-article","article-title":"In vitro study of the Norwood palliation: a patient-specific mock circulatory system","volume":"58","author":"Biglino","year":"2012","journal-title":"ASAIO J"},{"key":"bpexab8f6ebib11","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1007\/s13239-014-0184-8","type":"journal-article","article-title":"In vitro validation of patient-specific hemodynamic simulations in coronary aneurysms caused by kawasaki disease","volume":"5","author":"Kung","year":"2014","journal-title":"Cardiovasc Eng. Technol."},{"key":"bpexab8f6ebib12","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1136\/heartjnl-2016-309510","type":"journal-article","article-title":"Grading of mitral regurgitation based on intensity analysis of the continuous wave Doppler signal","volume":"103","author":"El Haddad","year":"2017","journal-title":"Heart"},{"key":"bpexab8f6ebib13","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.118.010279","type":"journal-article","article-title":"Optimal application of fractional flow reserve to assess serial coronary artery disease: a 3D-printed experimental study with clinical validation","volume":"7","author":"Modi","year":"2018","journal-title":"J. Am. Heart Assoc."},{"key":"bpexab8f6ebib14","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.6.2.021603","type":"journal-article","article-title":"Initial evaluation of three-dimensionally printed patient-specific coronary phantoms for CT-FFR software validation","volume":"6","author":"Shepard","year":"2019","journal-title":"J. Med. Imaging (Bellingham)"},{"key":"bpexab8f6ebib15","doi-asserted-by":"publisher","DOI":"10.1117\/12.2292736","type":"book","article-title":"3D printed cardiovascular patient specific phantoms used for clinical validation of a CT-derived FFR diagnostic software","author":"Sommer","year":"2018"},{"key":"bpexab8f6ebib16","article-title":"Initial simulated FFR Investigation using flow measurements in patient-specific 3D printed coronary phantoms","author":"Shepard","year":"2017","type":"book"},{"key":"bpexab8f6ebib17","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1186\/s12938-016-0155-4","type":"journal-article","article-title":"Numerical model of a valvuloplasty balloon: in vitro validation in a rapid-prototyped phantom","volume":"15","author":"Biffi","year":"2016","journal-title":"Biomed. Eng. Online"},{"key":"bpexab8f6ebib18","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1007\/s11548-010-0476-x","type":"journal-article","article-title":"3D printing based on imaging data: review of medical applications","volume":"5","author":"Rengier","year":"2010","journal-title":"International Journal of Computer Assisted Radiology and Surgery"},{"key":"bpexab8f6ebib19","doi-asserted-by":"publisher","first-page":"1735","DOI":"10.3349\/ymj.2015.56.6.1735","type":"journal-article","article-title":"Surgical planning by 3D printing for primary cardiac schwannoma resection","volume":"56","author":"Son","year":"2015","journal-title":"Yonsei Medical Journal"},{"key":"bpexab8f6ebib20","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s41205-018-0030-y","type":"journal-article","article-title":"Radiological Society of North America (RSNA) 3D printing special interest group (SIG): guidelines for medical 3D printing and appropriateness for clinical scenarios","volume":"4","author":"Chepelev","year":"2018","journal-title":"3D Printing in Medicine"},{"key":"bpexab8f6ebib21","doi-asserted-by":"publisher","first-page":"1965","DOI":"10.1148\/rg.2015140320","type":"journal-article","article-title":"Medical 3D printing for the radiologist","volume":"35","author":"Mitsouras","year":"2015","journal-title":"Radiographics"},{"key":"bpexab8f6ebib22","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/1532-429X-15-2","type":"journal-article","article-title":"Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing","volume":"15","author":"Biglino","year":"2013","journal-title":"Journal of Cardiovascular Magnetic Resonance"},{"key":"bpexab8f6ebib23","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.ajodo.2013.05.011","type":"journal-article","article-title":"Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques","volume":"145","author":"Hazeveld","year":"2014","journal-title":"American Journal of Orthodontics and Dentofacial Orthopedics"},{"key":"bpexab8f6ebib24","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1510\/icvts.2007.156588","type":"journal-article","article-title":"3D-Imaging of cardiac structures using 3D heart models for planning in heart surgery: a preliminary study","volume":"7","author":"Jacobs","year":"2008","journal-title":"Interactive Cardiovascular and Thoracic Surgery"},{"key":"bpexab8f6ebib25","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1016\/j.jcms.2012.11.041","type":"journal-article","article-title":"Accuracy of medical models made by additive manufacturing (rapid manufacturing)","volume":"41","author":"Salmi","year":"2013","journal-title":"J. Cranio Maxillof. Surg."},{"key":"bpexab8f6ebib26","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1016\/j.jocn.2011.07.031","type":"journal-article","article-title":"Three-dimensional anatomical accuracy of cranial models created by rapid prototyping techniques validated using a neuronavigation station","volume":"19","author":"Waran","year":"2012","journal-title":"Journal of Clinical Neuroscience"},{"key":"bpexab8f6ebib27","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2007.4353332","type":"conference-proceedings","article-title":"A beating heart model 3D printed from specific patient data","author":"Markert","year":"2007"},{"key":"bpexab8f6ebib28","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.jclinepi.2004.12.009","type":"journal-article","article-title":"Sample size calculation should be performed for design accuracy in diagnostic test studies","volume":"58","author":"Flahault","year":"2005","journal-title":"J. Clin. Epidemiol."},{"key":"bpexab8f6ebib29","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1097\/00004424-199402000-00020","type":"journal-article","article-title":"Computing sample size for receiver operating characteristic studies","volume":"29","author":"Obuchowski","year":"1994","journal-title":"Invest. Radiol"},{"key":"bpexab8f6ebib30","doi-asserted-by":"publisher","first-page":"1350","DOI":"10.1016\/j.jcmg.2016.11.024","type":"journal-article","article-title":"Noninvasive FFR derived from coronary CT angiography: management and outcomes in the PROMISE trial","volume":"10","author":"Lu","year":"2017","journal-title":"JACC Cardiovasc Imaging"},{"key":"bpexab8f6ebib31","volume":"vol 569","author":"Zhou","year":"2009","type":"book"},{"key":"bpexab8f6ebib32","article-title":"Design optimization for accurate flow simulations in 3D printed vascular phantoms derived from computed tomography angiography","author":"Sommer","year":"2017","type":"book"},{"key":"bpexab8f6ebib33","doi-asserted-by":"publisher","DOI":"10.1117\/12.2292736","type":"book","article-title":"3D printed cardiovascular patient specific phantoms used for clinical validation of a CT-derived FFR diagnostic software","author":"Sommer","year":"2018"},{"key":"bpexab8f6ebib34","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.6.2.021603","type":"journal-article","article-title":"Initial evaluation of three-dimensionally printed patient-specific coronary phantoms for CT-FFR software validation","volume":"6","author":"Shepard","year":"2019","journal-title":"Journal of Medical Imaging"},{"key":"bpexab8f6ebib35","doi-asserted-by":"publisher","first-page":"3195","DOI":"10.1007\/s10439-010-0083-6","type":"journal-article","article-title":"Patient-specific modeling of blood flow and pressure in human coronary arteries","volume":"38","author":"Kim","year":"2010","journal-title":"Ann. Biomed. Eng."},{"key":"bpexab8f6ebib36","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1152\/ajplegacy.1931.96.3.562","type":"journal-article","article-title":"The viscosity of the blood in narrow capillary tubes","volume":"96","author":"Fahraeus","year":"1931","journal-title":"American Journal of Physiology-Legacy Content"},{"key":"bpexab8f6ebib37","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.117.005073","type":"journal-article","article-title":"Effect of elective percutaneous coronary intervention on hyperemic absolute coronary blood flow volume and microvascular resistance","volume":"10","author":"Kanaji","year":"2017","journal-title":"Circ.: Cardiovascular Interventions"},{"key":"bpexab8f6ebib38","doi-asserted-by":"publisher","first-page":"1213","DOI":"10.1161\/CIRCULATIONAHA.105.595496","type":"journal-article","article-title":"Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: principal results of the conduit artery function evaluation (CAFE) study","volume":"113","author":"Williams","year":"2006","journal-title":"Circulation"},{"key":"bpexab8f6ebib39","article-title":"Use of patient specific 3D printed (3DP) neurovascular phantoms for mechanical assessment of devices used in image guided minimally invasive procedures","author":"Tabaczynski","year":"2018","type":"book"},{"key":"bpexab8f6ebib40","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/j.jcmg.2016.07.005","type":"journal-article","article-title":"Novel non-invasive CT-derived fractional flow reserve based on structural and fluid analysis (CT-FFR) for detection of functionally significant stenosis: a comparison with invasive fractional flow reserve","volume":"10","author":"Ko","year":"2017","journal-title":"JACC Cardiovasc Imaging"},{"key":"bpexab8f6ebib41","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1093\/ehjci\/jey114","type":"journal-article","article-title":"Performance of computed tomography-derived fractional flow reserve using reduced-order modelling and static computed tomography stress myocardial perfusion imaging for detection of haemodynamically significant coronary stenosis","volume":"19","author":"Ihdayhid","year":"2018","journal-title":"European Heart Journal-Cardiovascular Imaging"},{"key":"bpexab8f6ebib42","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1093\/ehjci\/jey104","type":"journal-article","article-title":"Diagnostic performance of on-site computed CT-fractional flow reserve based on fluid structure interactions: comparison with invasive fractional flow reserve and instantaneous wave-free ratio","volume":"20","author":"Fujimoto","year":"2018","journal-title":"European Heart Journal - Cardiovascular Imaging"},{"key":"bpexab8f6ebib43","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1148\/radiol.2017162620","type":"journal-article","article-title":"Fractional flow reserve estimated at coronary CT angiography in intermediate lesions: comparison of diagnostic accuracy of different methods to determine coronary flow distribution","volume":"287","author":"Kishi","year":"2017","journal-title":"Radiology"},{"key":"bpexab8f6ebib44","doi-asserted-by":"publisher","first-page":"6945","DOI":"10.1038\/s41598-018-25352-5","type":"journal-article","article-title":"Blooming artifact reduction in coronary artery calcification by a new De-blooming algorithm: initial study","volume":"8","author":"Li","year":"2018","journal-title":"Sci. Rep."},{"key":"bpexab8f6ebib45","doi-asserted-by":"publisher","DOI":"10.1148\/ryct.2019180012","type":"journal-article","article-title":"Inter-and intraoperator variability in measurement of on-site CT-derived fractional flow reserve based on structural and fluid analysis: a comprehensive analysis","volume":"1","author":"Kumamaru","year":"2019","journal-title":"Radiology: Cardiothoracic Imaging"},{"key":"bpexab8f6ebib46","doi-asserted-by":"publisher","first-page":"30","DOI":"10.21037\/qims.2018.09.17","type":"journal-article","article-title":"Imitating human soft tissue on basis of a dual-material 3D print using a support-filled metamaterial to provide bimanual haptic for a hand surgery training system","volume":"9","author":"Maier","year":"2019","journal-title":"Quantitative Imaging in Medicine and Surgery"},{"key":"bpexab8f6ebib47","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0208612","type":"journal-article","article-title":"Relationship between FFR, CFR and coronary microvascular resistance\u2014practical implications for FFR-guided percutaneous coronary intervention","volume":"14","author":"Garcia","year":"2019","journal-title":"PLoS One"},{"key":"bpexab8f6ebib48","doi-asserted-by":"publisher","first-page":"1834","DOI":"10.1097\/00003246-200208000-00027","type":"journal-article","article-title":"Assessment of cardiac output from systemic arterial pressure in humans","volume":"30","author":"Romano","year":"2002","journal-title":"Critical Care Medicine"},{"key":"bpexab8f6ebib49","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1016\/S1388-9842(03)00100-4","type":"journal-article","article-title":"The role of cardiac power and systemic vascular resistance in the pathophysiology and diagnosis of patients with acute congestive heart failure","volume":"5","author":"Cotter","year":"2003","journal-title":"Eur. J. Heart Failure"},{"key":"bpexab8f6ebib50","type":"book","article-title":"Study of the effect of boundary conditions on fractional flow reserve using patient specific coronary phantoms","volume":"vol 11317","author":"Sommer","year":"2020"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T15:30:05Z","timestamp":1768663805000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ab8f6e"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,11]]},"references-count":50,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020,5,11]]},"published-print":{"date-parts":[[2020,7,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ab8f6e","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,11]]},"assertion":[{"value":"Patient-specific 3D-printed coronary models based on coronary computed tomography angiography volumes to investigate flow conditions in coronary artery disease","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2020 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-02-17","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-05-01","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-05-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}