{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T04:45:40Z","timestamp":1768711540580,"version":"3.49.0"},"reference-count":25,"publisher":"IOP Publishing","issue":"6","license":[{"start":{"date-parts":[[2020,9,29]],"date-time":"2020-09-29T00:00:00Z","timestamp":1601337600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2020,9,29]],"date-time":"2020-09-29T00:00:00Z","timestamp":1601337600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2020,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Dose to the thyroid from helical chest CT can vary significantly due to the random tube start point, pitch factor, thyroid position relative to the isocenter, and beam width. We used optically stimulated luminescence dosimeters (OSLDs) and an adult anthropomorphic phantom to investigate the uncertainty of thyroid dose estimate. Maximum gap or overlap in the helical beam was estimated using the above factors. Using the maximum gap\/overlap over the thyroid, different possible scenarios were simulated and the degree of missed thyroid tissue by the primary beam was estimated. Results showed a variation of &gt;30% in the average thyroid dose, and &gt;50% if a single dosimeter was used to determine dose to the thyroid. Furthermore, measured doses were compared to those calculated by Monte Carlo simulation software, which automatically matches the anatomy of the localizer radiograph with the stylized computational phantom used for dose calculation. The difference was significant: the dose given by the Monte Carlo software was \u223c50% lower than the average dose measured with the phantom in all three chest protocols. In addition, the software does not take the effect of the random tube start angle into account.<\/jats:p>","DOI":"10.1088\/2057-1976\/abb8f3","type":"journal-article","created":{"date-parts":[[2020,9,16]],"date-time":"2020-09-16T18:18:19Z","timestamp":1600280299000},"page":"065012","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["The uncertainty of thyroid dose estimate in chest CT"],"prefix":"10.1088","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2123-2057","authenticated-orcid":false,"given":"R","family":"Al-Senan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K","family":"Brown","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M","family":"Erdman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S","family":"King","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2020,9,29]]},"reference":[{"key":"bpexabb8f3bib1","author":"AAPM A","year":"2016","type":"other"},{"key":"bpexabb8f3bib2","doi-asserted-by":"publisher","first-page":"4396","DOI":"10.1118\/1.3602456","type":"journal-article","article-title":"Characteristics of an OSLD in the diagnostic energy range","volume":"38","author":"Al-Senan","year":"2011","journal-title":"Med. Phys."},{"key":"bpexabb8f3bib3","doi-asserted-by":"publisher","first-page":"4211","DOI":"10.1088\/0031-9155\/57\/13\/4211","type":"journal-article","article-title":"Estimating thyroid dose in pediatric CT exams from surface dose measurement","volume":"57","author":"Al-Senan","year":"2012","journal-title":"Phys Med Bio"},{"key":"bpexabb8f3bib4","type":"other"},{"key":"bpexabb8f3bib5","doi-asserted-by":"crossref","DOI":"10.2172\/5308345","type":"book","article-title":"Mathematical phantoms representing children of various ages for use in estimates of internal dose","author":"Cristy","year":"1980"},{"key":"bpexabb8f3bib6","doi-asserted-by":"publisher","first-page":"5601","DOI":"10.1088\/0031-9155\/60\/14\/5601","type":"journal-article","article-title":"VirtualDose\u202f: a software for reporting organ doses from CT for adult and pediatric patients","volume":"60","author":"Ding","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"bpexabb8f3bib7","doi-asserted-by":"publisher","first-page":"778","DOI":"10.3174\/ajnr.A3743","type":"journal-article","article-title":"An exponential growth in incidence of thyroid cancer: trends and impact of CT imaging","volume":"35","author":"Hoang","year":"2014","journal-title":"American Journal of Neuroradiology"},{"key":"bpexabb8f3bib8","doi-asserted-by":"publisher","DOI":"10.1001\/jamanetworkopen.2019.10584","type":"journal-article","article-title":"Association of exposure to diagnostic low-dose ionizing radiation with risk of cancer among youths in South Korea","volume":"2","author":"Hong","year":"2019","journal-title":"JAMA Netw Open"},{"key":"bpexabb8f3bib9","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1093\/rpd\/nct090","type":"journal-article","article-title":"Computation of thyroid doses and carcinogenic radiation risks to patients undergoing neck ct examinations","volume":"156","author":"Huda","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"key":"bpexabb8f3bib10","author":"ICRP","year":"2007","type":"book"},{"key":"bpexabb8f3bib11","author":"ImPACT","year":"2002","type":"web-resource"},{"key":"bpexabb8f3bib12","doi-asserted-by":"publisher","first-page":"2038","DOI":"10.1118\/1.1764702","type":"journal-article","article-title":"The effect of unrealistic thyroid vertical position on thyroid dose in the MIRD phantom","volume":"31","author":"Lee","year":"2004","journal-title":"Med. Phys."},{"key":"bpexabb8f3bib13","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1088\/0031-9155\/55\/2\/002","type":"journal-article","article-title":"The UF family of reference hybrid phantoms for computational radiation dosimetry","volume":"55","author":"Lee","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"bpexabb8f3bib14","doi-asserted-by":"publisher","first-page":"1196","DOI":"10.1118\/1.3544658","type":"journal-article","article-title":"Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations","volume":"38","author":"Lee","year":"2011","journal-title":"Med. Phys."},{"key":"bpexabb8f3bib15","doi-asserted-by":"publisher","DOI":"10.1118\/1.4790470","type":"journal-article","article-title":"Monte Carlo assessment of CT dose equilibration in PMMA and water cylinders with diameters from 6 to 55 cm","volume":"40","author":"Li","year":"2013","journal-title":"Med. Phys."},{"key":"bpexabb8f3bib16","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1097\/TA.0b013e31823a4bd7","type":"journal-article","article-title":"Theoretical increase of thyroid cancer induction from cervical spine multidetector computed tomography in pediatric trauma patients","volume":"72","author":"Muchow","year":"2012","journal-title":"The Journal of Trauma and Acute Care Surgery"},{"key":"bpexabb8f3bib17","doi-asserted-by":"publisher","first-page":"259","DOI":"10.2307\/3579003","type":"journal-article","article-title":"Thyroid cancer after exposure to external radiation: a pooled analysis of seven studies","author":"Ron","year":"1995","journal-title":"Radiat. Res."},{"key":"bpexabb8f3bib18","doi-asserted-by":"publisher","DOI":"10.1093\/jncics\/pkz072","type":"journal-article","article-title":"Exposure to tomographic scans and cancer risks","volume":"4","author":"Shao","year":"2020","journal-title":"JNCI Cancer Spectrum"},{"key":"bpexabb8f3bib19","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1088\/0031-9155\/26\/1\/013","type":"journal-article","article-title":"The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities","volume":"26","author":"Shrimpton","year":"1981","journal-title":"Phys. Med. Biol."},{"key":"bpexabb8f3bib20","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1210\/er.2010-0003","type":"journal-article","article-title":"Exposing the thyroid to radiation: a review of its current extent, risks, and implications","volume":"31","author":"Sinnott","year":"2010","journal-title":"Endocrine Reviews"},{"key":"bpexabb8f3bib21","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1148\/radiol.2015142728","type":"journal-article","article-title":"Radiation doses in consecutive CT examinations from five university of california medical centers","volume":"277","author":"Smith-Bindman","year":"2015","journal-title":"Radiology"},{"key":"bpexabb8f3bib22","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1007\/s00330-015-3590-x","type":"journal-article","article-title":"Thyroid doses and risk to paediatric patients undergoing neck CT examinations","volume":"25","author":"Spampinato","year":"2015","journal-title":"Eur Radiol"},{"key":"bpexabb8f3bib23","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.2214\/AJR.14.13102","type":"journal-article","article-title":"Thyroid doses and risks to adult patients undergoing neck CT examinations","volume":"204","author":"Tipnis","year":"2015","journal-title":"American Journal of Roentgenology"},{"key":"bpexabb8f3bib24","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1118\/1.3533897","type":"journal-article","article-title":"The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams","volume":"38","author":"Turner","year":"2011","journal-title":"Med. Phys."},{"key":"bpexabb8f3bib25","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1118\/1.3078053","type":"journal-article","article-title":"Variability of surface and center position radiation dose in MDCT: Monte Carlo simulations using CTDI and anthropomorphic phantoms","volume":"36","author":"Zhang","year":"2009","journal-title":"Med. Phys."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T15:30:16Z","timestamp":1768663816000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/abb8f3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,29]]},"references-count":25,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2020,9,29]]},"published-print":{"date-parts":[[2020,11,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/abb8f3","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,29]]},"assertion":[{"value":"The uncertainty of thyroid dose estimate in chest CT","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2020 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2020-06-09","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-09-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2020-09-29","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}