{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T22:07:47Z","timestamp":1740175667067,"version":"3.37.3"},"reference-count":29,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T00:00:00Z","timestamp":1669334400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T00:00:00Z","timestamp":1669334400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100012331","name":"Agentschap Innoveren en Ondernemen","doi-asserted-by":"crossref","award":["HBC.2017.0575"],"award-info":[{"award-number":["HBC.2017.0575"]}],"id":[{"id":"10.13039\/100012331","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2023,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Purpose<\/jats:italic>. The objective of this study was to analyse the possibilities of using 4D CT scanning for the tracking of patients\u2019 mandibles. <jats:italic>Methods<\/jats:italic>. A clinical 256-slice Revolution CT was used in obtaining 4D CT scans without table movement, with a novel mandibular phantom, mounted on a programmable six degrees-of-freedom Stewart Platform in motion. The phantom was used to simulate mandibular motions which are combinations of rotations with translations (depression, elevation, protrusion, retrusion and laterotrusion). The phantom was scanned five times during identical motion patterns with a dynamic CT acquisition protocol. An image processing workflow consisting of a pairwise rigid registration and semi-automatic segmentation was developed to extract kinematic parameters (cardan angles and point-of-interest displacements) from the dynamic sequences. Reproducibility was investigated by the 95% confidence interval and the absorbed organ dose to organs of interest in the primary beam were also estimated and compared to those of a standard CT scan of the brain <jats:italic>Results<\/jats:italic>. The maximum average 95% confidence interval for the displacement across all time points for the five repetitions was 0.61 mm (<jats:italic>Y<\/jats:italic> axis). In terms of rotations, the maximum average 95% confidence interval across all time points for the five repetitions was 1.39\u00b0 (<jats:italic>X<\/jats:italic> axis). The effective dose for the dynamic scan was found to be 1.3 mSv, for a CTDI<jats:sub>vol<\/jats:sub> of 63.95 mGy and a DLP of 1023.14 mGycm. The absorbed organ doses were similar to organ doses during a clinical head CT scan. <jats:italic>Conclusions<\/jats:italic>. A framework is proposed to use 4D CT scanning as a possible methodology to evaluate the motion of the temporomandibular joint. The scanning protocol allows to visualise the motion by applying a semi-automated segmentation and registration. A graphical representation of all displacements in the three spatial dimensions can depict multiple points-of-interest at once during the same acquisition. A novel type of phantom was also introduced which simulates mandibular movement with six degrees-of-freedom (three translations and three rotations).<\/jats:p>","DOI":"10.1088\/2057-1976\/aca336","type":"journal-article","created":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T22:11:45Z","timestamp":1668636705000},"page":"015002","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["The use of dynamic CT imaging for tracking mandibular movements in a phantom"],"prefix":"10.1088","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6121-901X","authenticated-orcid":true,"given":"Stijn E F","family":"Huys","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benyameen","family":"Keelson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yannick","family":"de Brucker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gert","family":"Van Gompel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johan","family":"de Mey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos","family":"Vander Sloten","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nico","family":"Buls","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2022,11,25]]},"reference":[{"key":"bpexaca336bib1","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1097\/PRS.0b013e31829ad299","article-title":"Virtual surgical planning in complex composite maxillofacial reconstruction","volume":"132","author":"Saad","year":"2013","journal-title":"Plast Reconstr Surg"},{"key":"bpexaca336bib2","doi-asserted-by":"publisher","first-page":"932","DOI":"10.1016\/j.joms.2018.12.027","article-title":"Postoperative physiotherapy after open temporomandibular joint surgery: A 3-step program","volume":"77","author":"De Meurechy","year":"2019","journal-title":"J. Oral Maxillof. Surg."},{"key":"bpexaca336bib3","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/95958184","article-title":"A method for measuring three-dimensional mandibular kinematics in vivo using single-plane fluoroscopy","volume":"42","author":"Chen","year":"2013","journal-title":"Dentomaxillofacial Radiology"},{"key":"bpexaca336bib4","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1007\/s00455-013-9453-1","article-title":"Fluoroscopic evaluation of tongue and jaw movements during mastication in healthy humans","volume":"28","author":"Taniguchi","year":"2013","journal-title":"Dysphagia"},{"key":"bpexaca336bib5","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.ajodo.2006.09.061","article-title":"Four-dimensional analysis of stomatognathic function","volume":"134","author":"Terajima","year":"2008","journal-title":"American Journal of Orthodontics and Dentofacial Orthopedics"},{"key":"bpexaca336bib6","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1109\/TMI.2009.2038908","article-title":"Registration of 4D cardiac CT sequences under trajectory constraints with multichannel diffeomorphic demons","volume":"29","author":"Peyrat","year":"2010","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexaca336bib7","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1161\/STROKEAHA.111.626846","article-title":"Cardiac cycle-related volume change in unruptured cerebral aneurysms: A detailed volume quantification study using 4-dimensional ct angiography","volume":"43","author":"Kuroda","year":"2012","journal-title":"Stroke"},{"key":"bpexaca336bib8","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.ejmp.2019.06.006","article-title":"Estimation of respiratory phases during proton radiotherapy from a 4D-CT and Prompt gamma detection profiles","volume":"64","author":"Albert","year":"2019","journal-title":"Physica Med."},{"key":"bpexaca336bib9","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1007\/s10072-011-0785-z","article-title":"Measurement of cerebral circulation times using dynamic whole-brain CT-angiography: Feasibility and initial experience","volume":"33","author":"Siebert","year":"2012","journal-title":"Neurological Sciences"},{"key":"bpexaca336bib10","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1007\/s11604-010-0469-2","article-title":"Diagnosing a large slowly enhanced cerebral aneurysm using four-dimensional multiphase dynamic contrast-enhanced computed tomography angiography","volume":"28","author":"Suzuki","year":"2010","journal-title":"Jpn J Radiol"},{"key":"bpexaca336bib11","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s00234-011-0864-0","article-title":"The use of 4D-CTA in the diagnostic work-up of brain arteriovenous malformations","volume":"54","author":"Willems","year":"2012","journal-title":"Neuroradiology"},{"key":"bpexaca336bib12","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1302\/0301-620X.103B5.BJJ-2020-1064.R2","article-title":"Evaluating lower limb kinematics and pathology with dynamic CT","volume":"103-B","author":"Buzzatti","year":"2021","journal-title":"Bone Joint J"},{"key":"bpexaca336bib13","doi-asserted-by":"publisher","first-page":"S50","DOI":"10.1118\/1.3577759","article-title":"Dynamic CT technique for assessment of wrist joint instabilities","volume":"38","author":"Leng","year":"2011","journal-title":"Med. Phys."},{"key":"bpexaca336bib14","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.3349\/ymj.2013.54.4.1026","article-title":"Four-dimensional real-time cine images of wrist joint kinematics using dual source CT with minimal time increment scanning","volume":"54","author":"Choi","year":"2013","journal-title":"Yonsei Med J"},{"key":"bpexaca336bib15","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1097\/RCT.0b013e31828b68ec","article-title":"Four-dimensional computed tomography and trigger lunate syndrome","volume":"37","author":"Troupis","year":"2013","journal-title":"J. Comput. Assist. Tomogr."},{"key":"bpexaca336bib16","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1111\/1754-9485.12326","article-title":"Four-dimensional computed tomography (4DCT): a review of the current status and applications","volume":"59","author":"Kwong","year":"2015","journal-title":"J Med Imaging Radiat Oncol"},{"key":"bpexaca336bib17","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/j.jcms.2016.01.027","article-title":"Four-dimensional computed tomography evaluation of jaw movement following mandibular reconstruction: a pilot study","volume":"44","author":"Akashi","year":"2016","journal-title":"J. Cranio Maxillof. Surg."},{"key":"bpexaca336bib18","doi-asserted-by":"publisher","DOI":"10.1117\/12.2542159","article-title":"Quantifying motion artifacts using a rotating phantom: insights towards dynamic musculoskeletal applications","volume":"11312","author":"Keelson","year":"2020","journal-title":"Medical Imaging 2020: Physics of Medical Imaging"},{"key":"bpexaca336bib19","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/S0094-114X(99)00006-3","article-title":"The Stewart platform manipulator: a review","volume":"35","author":"Dasgupta","year":"2000","journal-title":"Mech. Mach. Theory"},{"key":"bpexaca336bib20","first-page":"160","author":"Posselt","year":"1952","journal-title":"Studies in the mobility of the human mandible"},{"key":"bpexaca336bib21","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1088\/0952-4746\/35\/4\/891","article-title":"NCICT: a computational solution to estimate organ doses for pediatric and adult patients undergoing CT scans","volume":"35","author":"Lee","year":"2015","journal-title":"J. Radiol. Prot."},{"key":"bpexaca336bib22","article-title":"Radiation protection N\u00b0 180: diagnostic reference levels in thirty-six european countries","author":"","year":"2014","journal-title":"European Commission"},{"key":"bpexaca336bib23","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1016\/S0278-2391(96)90678-3","article-title":"Mandibular excursions and maximum bite forces in patients with temporomandibular joint disorders","volume":"54","author":"Sinn","year":"1996","journal-title":"J Oral Maxillofac Surg"},{"key":"bpexaca336bib24","doi-asserted-by":"publisher","first-page":"1380","DOI":"10.1016\/j.mayocp.2015.07.011","article-title":"Answers to common questions about the use and safety of CT scans","volume":"90","author":"McCollough","year":"2015","journal-title":"Mayo Clin Proc"},{"key":"bpexaca336bib25","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1148\/radiol.2020192256","article-title":"Patient exposure from radiologic and nuclear medicine procedures in the United States: Procedure volume and effective dose for the period 2006\u20132016","volume":"295","author":"Mettler","year":"2020","journal-title":"Radiology"},{"key":"bpexaca336bib26","doi-asserted-by":"publisher","first-page":"3767","DOI":"10.1118\/1.2349687","article-title":"Intraoperative cone-beam CT for guidance of head and neck surgery: assessment of dose and image quality using a C-arm prototype","volume":"33","author":"Daly","year":"2006","journal-title":"Med. Phys."},{"key":"bpexaca336bib27","doi-asserted-by":"publisher","first-page":"1523","DOI":"10.1016\/j.acra.2019.12.011","article-title":"Eye shielding during head CT scans: dose reduction and image quality evaluation","volume":"27","author":"Lee","year":"2020","journal-title":"Acad. Radiol."},{"key":"bpexaca336bib28","first-page":"101","article-title":"Studies on function and dysfunction of the masticatory system. II. Index for anamnestic and clinical dysfunction and occlusal state","volume":"67","author":"Helkimo","year":"1974","journal-title":"Sven Tandlak Tidskr"},{"key":"bpexaca336bib29","doi-asserted-by":"publisher","first-page":"2062","DOI":"10.3390\/diagnostics11112062","article-title":"Automated motion analysis of bony joint structures from dynamic computer tomography images: A multi-atlas approach","volume":"11","author":"Keelson","year":"2021","journal-title":"Diagnostics"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T11:45:47Z","timestamp":1669376747000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aca336"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,25]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,11,25]]},"published-print":{"date-parts":[[2023,1,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/aca336","relation":{},"ISSN":["2057-1976"],"issn-type":[{"type":"electronic","value":"2057-1976"}],"subject":[],"published":{"date-parts":[[2022,11,25]]},"assertion":[{"value":"The use of dynamic CT imaging for tracking mandibular movements in a phantom","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2022 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2022-06-10","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-11-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2022-11-25","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}