{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T19:07:02Z","timestamp":1780686422207,"version":"3.54.1"},"reference-count":22,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T00:00:00Z","timestamp":1677715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T00:00:00Z","timestamp":1677715200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2023,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Purpose<\/jats:italic>: Patient radiation doses in cardiovascular and interventional radiology are highly variable for similar procedures. This random nature may be better described by a distribution function, compared to a linear regression. This study develops a distribution function to characterize patient dose distributions and estimate probabilistic risk. <jats:italic>Methods<\/jats:italic>: Reference air kerma from 8647 patients over six years were retrospectively collected from an EP lab and two Cath labs. Data was first sorted into low dose (&lt;100mGy) and high dose cases (&gt;100mGy), and histograms of the data created. Dagum and Inverse gamma distributions were chosen to initially fit to both low and high dose cases. Fits between model and the data was optimized, and a linear regression analysis performed to obtain R squared values and standard errors for the correlation between model and data. Risk probabilities were estimated according to the modeled distribution function. BMI and time distributions were analyzed to understand their influence on the inverse gamma distribution error found in the data. 75th percentiles from both descriptive statistics and model were calculated. <jats:italic>Results<\/jats:italic>: The inverse gamma distribution can be used to characterize radiation dose distributions. Model predicted cases for radiation dose 3000mGy&lt; x &lt;5000mGy and &gt;5000mGy are approximately 42 and 0 for 3651 cases for lab#1, and 14 and 1 for 3197 cases for lab#2, respectively, while the actual cases are 10 and 0, and 16 and 2. Descriptive and model statistics generated different 75th percentile levels for sorted data compared to unsorted data. Time has a greater influence on inverse gamma distribution function than BMI. <jats:italic>Conclusion<\/jats:italic>: This study creates a framework to understand the random error present in radiology practices that cause wide variations in patient radiation doses. It also provides an approach to evaluate different IR areas in terms of effectiveness of dose reduction measures.<\/jats:p>","DOI":"10.1088\/2057-1976\/acbcd6","type":"journal-article","created":{"date-parts":[[2023,2,17]],"date-time":"2023-02-17T17:21:17Z","timestamp":1676654477000},"page":"035005","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Characterization of patient dose distributions and probabilistic risk analysis in cardiovascular catheterization laboratories"],"prefix":"10.1088","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9789-624X","authenticated-orcid":true,"given":"Victor J","family":"Weir","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2006-9964","authenticated-orcid":true,"given":"Jie","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M Rehan","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2023,3,2]]},"reference":[{"key":"bpexacbcd6bib1","doi-asserted-by":"publisher","first-page":"4281","DOI":"10.1007\/s00330-017-4780-5","type":"journal-article","article-title":"Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France","volume":"27","author":"Etard","year":"2017","journal-title":"European radiology"},{"key":"bpexacbcd6bib2","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s00270-008-9439-9","type":"journal-article","article-title":"Patient dose reference levels for interventional radiology: a national approach","volume":"32","author":"Vano","year":"2009","journal-title":"Cardiovascular and Interventional Radiology"},{"key":"bpexacbcd6bib3","doi-asserted-by":"publisher","first-page":"846","DOI":"10.3390\/diagnostics10100846","type":"journal-article","article-title":"Hybrid operating room system for the treatment of thoracic and abdominal aortic aneurysms: evaluation of the radiation dose received by patients","volume":"10","author":"Haga","year":"2020","journal-title":"Diagnostics"},{"key":"bpexacbcd6bib4","doi-asserted-by":"publisher","first-page":"1900","DOI":"10.3748\/wjg.v21.i6.1900","type":"journal-article","article-title":"Measures of patient radiation exposure during endoscopic retrograde cholangiography: beyond fluoroscopy time","volume":"21","author":"Kachaamy","year":"2015","journal-title":"World J. Gastroenterol.: WJG"},{"key":"bpexacbcd6bib5","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1259\/bjr\/19929794","type":"journal-article","article-title":"Diagnostic reference levels and effective dose in paediatric cardiac catheterization","volume":"80","author":"Onnasch","year":"2007","journal-title":"The British Journal of Radiology"},{"key":"bpexacbcd6bib6","author":"Casella","year":"2002","edition":"2nd edn","type":"book"},{"key":"bpexacbcd6bib7","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1080\/01621459.2018.1537917","type":"journal-article","article-title":"On degrees of freedom of projection estimators with applications to multivariate nonparametric regression","volume":"115","author":"Chen","year":"2020","journal-title":"J. Am. Stat. Assoc."},{"key":"bpexacbcd6bib8","doi-asserted-by":"publisher","first-page":"5713","DOI":"10.1118\/1.3013604","type":"journal-article","article-title":"Overview of patient dosimetry in diagnostic radiology in the USA for the past","volume":"35","author":"Huda","year":"2008","journal-title":"Med. Phys."},{"key":"bpexacbcd6bib9","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1148\/radiol.2019180799","type":"journal-article","article-title":"Radiation dose monitoring for fluoroscopically guided interventional procedures: effect on patient radiation exposure","volume":"290","author":"Liu","year":"2019","journal-title":"Radiology"},{"key":"bpexacbcd6bib10","first-page":"199","type":"journal-article","article-title":"A model of income distribution and the conditions of existence of moments of finite order","volume":"46","author":"Dagum","year":"1975","journal-title":"Bulletin of the International Statistical Institute"},{"key":"bpexacbcd6bib11","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1214\/aoms\/1177704481","type":"journal-article","article-title":"A generalization of the gamma distribution","author":"Stacy","year":"1962","journal-title":"The Annals of mathematical statistics"},{"key":"bpexacbcd6bib12","first-page":"202","type":"journal-article","article-title":"Hand-book on statistical distributions for experimentalists","volume":"10","author":"Walck","year":"2007","journal-title":"University of Stockholm"},{"key":"bpexacbcd6bib13","first-page":"16","type":"journal-article","article-title":"On the inverted gamma distribution","volume":"1","author":"Abid","year":"2016","journal-title":"International Journal of Systems Science and Applied Mathematics"},{"key":"bpexacbcd6bib14","first-page":"p 352","type":"book","author":"Oksendal","year":"2003","edition":"5th edn"},{"key":"bpexacbcd6bib15","author":"Koralov","year":"2007","edition":"2nd edn","type":"book"},{"key":"bpexacbcd6bib16","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1097\/EDE.0b013e318261c86f","type":"journal-article","article-title":"Adolphe quetelet: statistician and more","volume":"23","author":"Faerstein","year":"2012","journal-title":"Epidemiology"},{"key":"bpexacbcd6bib17","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1148\/radiol.2017161911","type":"journal-article","article-title":"US diagnostic reference levels and achievable doses for 10 adult CT examinations","volume":"284","author":"Kanal","year":"2017","journal-title":"Radiology"},{"key":"bpexacbcd6bib18","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1093\/rpd\/ncw018","type":"journal-article","article-title":"The establishment of local diagnostic reference levels in endoscopic retrograde cholangiopancreatography: a practical tool for the optimisation and for quality assurance management","volume":"173","author":"Saukko","year":"2017","journal-title":"Radiat. Prot. Dosim."},{"key":"bpexacbcd6bib19","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1118\/1.3557868","type":"journal-article","article-title":"Patient radiation dose audits for fluoroscopically guided interventional procedures","volume":"38","author":"Balter","year":"2011","journal-title":"Med. Phys."},{"key":"bpexacbcd6bib20","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1016\/j.jcin.2010.10.014","type":"journal-article","article-title":"Clinical determinants of radiation dose in percutaneous coronary interventional procedures: influence of patient size, procedure complexity, and performing physician","volume":"4","author":"Fetterly","year":"2011","journal-title":"JACC: Cardiovascular Interventions"},{"key":"bpexacbcd6bib21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s42155-020-00159-6","type":"journal-article","article-title":"Fluoroscopically-guided interventions with radiation doses exceeding 5000 mGy reference point air kerma: a dosimetric analysis of 89,549 interventional radiology, neurointerventional radiology, vascular surgery, and neurosurgery encounters","volume":"3","author":"Bundy","year":"2020","journal-title":"CVIR endovascular"},{"key":"bpexacbcd6bib22","doi-asserted-by":"publisher","first-page":"309","DOI":"10.3233\/XST-140427","type":"journal-article","article-title":"Impact of physician practice on patient radiation dose during CT guided biopsy procedures","volume":"22","author":"Weir","year":"2014","journal-title":"J. X-Ray Sci. Technol."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:27:10Z","timestamp":1760189230000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/acbcd6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,2]]},"references-count":22,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,3,2]]},"published-print":{"date-parts":[[2023,5,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/acbcd6","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,2]]},"assertion":[{"value":"Characterization of patient dose distributions and probabilistic risk analysis in cardiovascular catheterization laboratories","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2022-12-22","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-02-17","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-03-02","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}