{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T07:49:02Z","timestamp":1789026542701,"version":"build-2803163510"},"reference-count":52,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2023,7,20]],"date-time":"2023-07-20T00:00:00Z","timestamp":1689811200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2023,7,20]],"date-time":"2023-07-20T00:00:00Z","timestamp":1689811200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2023,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    Phantoms that mimic healthy or diseased organ properties can complement animal models for surgical planning, training, and medical device development. If urodynamic studies rely on pressure-volume curves to assess lower urinary tract symptoms, there is an unsatisfied need for a bladder phantom that accurately mimics the bladder stretching capabilities and compliant behaviour during physiological filling.\n                    <jats:italic>Approach.<\/jats:italic>\n                    We demonstrate the suitability of water-soluble 3D-printed moulds as a versatile method to fabricate accurate phantoms with anatomical structures reconstructed from medical images. We report a phantom fabricated with silicone rubber. A wire net limits the silicone expansion to model the cystometric capacity. A mathematical model describes the pressure increase due to passive hyperelastic properties.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The phantom reproduces the bladder\u2019s mechanical properties during filling. The pressure-volume curve measured on the phantom is typical of cystometric studies, with a compliance of 25.2 \u00b1 1\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mi mathvariant=\"normal\">ml<\/mml:mi>\n                        <mml:mspace width=\"0.25em\"\/>\n                        <mml:msub>\n                          <mml:mrow>\n                            <mml:mi mathvariant=\"normal\">cmH<\/mml:mi>\n                          <\/mml:mrow>\n                          <mml:mrow>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:mrow>\n                        <\/mml:msub>\n                        <mml:msup>\n                          <mml:mrow>\n                            <mml:mi mathvariant=\"normal\">O<\/mml:mi>\n                          <\/mml:mrow>\n                          <mml:mrow>\n                            <mml:mo>\u2212<\/mml:mo>\n                            <mml:mn>1<\/mml:mn>\n                          <\/mml:mrow>\n                        <\/mml:msup>\n                        <mml:mo>.<\/mml:mo>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    The root-mean-square error between the theoretical model and experimental data is 2.7\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:mrow>\n                            <mml:mi mathvariant=\"normal\">cmH<\/mml:mi>\n                          <\/mml:mrow>\n                          <mml:mrow>\n                            <mml:mn>2<\/mml:mn>\n                          <\/mml:mrow>\n                        <\/mml:msub>\n                        <mml:mi mathvariant=\"normal\">O<\/mml:mi>\n                        <mml:mo>.<\/mml:mo>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    The compliance, bladder wall thickness, cystometric capacity and pressure near the cystometric capacity of the phantom can be tuned to mimic various pathologies or human variability.\n                    <jats:italic>Significance.<\/jats:italic>\n                    The manufacturing method is suitable for fabricating bladder and other soft and hollow organ phantoms. The mathematical model provides a method to determine design parameters to model healthy or diseased bladders. Soft hollow organ phantoms can be used to complement animal experimentations for developing and validating medical devices aiming to be anchored on these organs or monitor their activity through pressure and strain measurement.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ace449","type":"journal-article","created":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T18:20:56Z","timestamp":1688581256000},"page":"055006","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":9,"title":["Urinary bladder phantom mimicking mechanical properties and pressure during filling"],"prefix":"10.1088","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8882-6541","authenticated-orcid":false,"given":"Maxime","family":"Verstraeten","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2644-1803","authenticated-orcid":false,"given":"George","family":"Bou Kheir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3401-2993","authenticated-orcid":false,"given":"Louis","family":"Vande Perre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1439-0367","authenticated-orcid":false,"given":"Romain","family":"Raffoul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1155-6701","authenticated-orcid":false,"given":"Javier","family":"Chavez Cerda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6047-1002","authenticated-orcid":false,"given":"Alain","family":"Delchambre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5377-8137","authenticated-orcid":false,"given":"Thierry","family":"Roumeguere","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7244-5864","authenticated-orcid":false,"given":"Anne","family":"Vanhoestenberghe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0292-9588","authenticated-orcid":false,"given":"Antoine","family":"Nonclercq","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2023,7,20]]},"reference":[{"key":"bpexace449bib1","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/S1570\u20139124(03)00035\u20137","type":"journal-article","article-title":"Innervation and function of the female urinary bladder and urethra","volume":"1","author":"Bannowsky","year":"2003","journal-title":"EAU Updat. Ser."},{"key":"bpexace449bib2","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1177\/0954411918754925","type":"journal-article","article-title":"Is submucosal bladder pressure monitoring feasible?","volume":"233","author":"Basu","year":"2019","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"bpexace449bib3","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/978-3-319-23687-2_3","type":"book","article-title":"Urodynamics evaluation of underactive bladder","author":"Chancellor","year":"2016"},{"key":"bpexace449bib4","doi-asserted-by":"publisher","first-page":"2412","DOI":"10.1007\/s10439-021-02793-0","type":"journal-article","article-title":"Soft urinary bladder phantom for endoscopic training","volume":"49","author":"Choi","year":"2021","journal-title":"Ann. Biomed. Eng."},{"key":"bpexace449bib5","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1080\/003655999750169385","type":"journal-article","article-title":"Whole bladder mechanics during filling","volume":"33","author":"Damaser","year":"1999","journal-title":"Scand. J. Urol. Nephrol."},{"key":"bpexace449bib6","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1002\/nau.23897","type":"journal-article","article-title":"The International Continence Society (ICS) report on the terminology for adult male lower urinary tract and pelvic floor symptoms and dysfunction","volume":"38","author":"D\u2019Ancona","year":"2019","journal-title":"Neurourol. Urodyn."},{"key":"bpexace449bib7","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1111\/aor.14156","type":"journal-article","article-title":"Impact of adaptive gastric electrical stimulation on weight, food intake, and food intake rate in dogs","volume":"46","author":"Debelle","year":"2022","journal-title":"Artif. Organs"},{"key":"bpexace449bib8","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.medengphy.2021.05.004","type":"journal-article","article-title":"Optimization and assessment of a novel gastric electrode anchoring system designed to be implanted by minimally invasive surgery","volume":"92","author":"Debelle","year":"2021","journal-title":"Med. Eng. Phys."},{"key":"bpexace449bib9","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/C2009-0-02755-X","type":"book","article-title":"Mechanical properties of tissue","volume":"18","author":"Duck","year":"1990","edition":"edn 1"},{"key":"bpexace449bib10","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.1118\/1.3352686","type":"journal-article","article-title":"Tissue-mimicking bladder wall phantoms for evaluating acoustic radiation force-optical coherence elastography systems","volume":"37","author":"Ejofodomi","year":"2010","journal-title":"Med. Phys."},{"key":"bpexace449bib11","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1109\/58.656639","type":"journal-article","article-title":"Phantom materials for elastography","volume":"44","author":"Hall","year":"1997","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"bpexace449bib12","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/B978-1-4160-2339-5.50060-4","type":"book","article-title":"Urodynamics","author":"Henry Lai","year":"2008","edition":"3rd edn"},{"key":"bpexace449bib13","doi-asserted-by":"publisher","first-page":"2477","DOI":"10.1016\/j.actbio.2011.02.016","type":"journal-article","article-title":"Analysis of the in vitro swelling behavior of poly(vinyl alcohol) hydrogels in osmotic pressure solution for soft tissue replacement","volume":"7","author":"Holloway","year":"2011","journal-title":"Acta Biomater."},{"key":"bpexace449bib14","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1111\/j.1464-410x.2010.09993.x","type":"journal-article","article-title":"Worldwide prevalence estimates of lower urinary tract symptoms, overactive bladder, urinary incontinence and bladder outlet obstruction","volume":"108","author":"Irwin","year":"2011","journal-title":"BJU Int."},{"key":"bpexace449bib15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1126\/sciadv.abc9675","type":"journal-article","article-title":"Expandable and implantable bioelectronic complex for analyzing and regulating real-time activity of the urinary bladder","volume":"6","author":"Jang","year":"2020","journal-title":"Sci. Adv."},{"key":"bpexace449bib16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/advs.202101394","type":"journal-article","article-title":"3D printing of physical organ models: recent developments and challenges","volume":"8","author":"Jin","year":"2021","journal-title":"Adv. Sci."},{"key":"bpexace449bib17","doi-asserted-by":"publisher","first-page":"1379","DOI":"10.1016\/s0022-5347(17)35264-3","type":"journal-article","article-title":"Bladder pressure sensors in an animal model","volume":"151","author":"Koldewijn","year":"1994","journal-title":"J. Urol."},{"key":"bpexace449bib18","doi-asserted-by":"publisher","first-page":"1381","DOI":"10.1364\/boe.3.001381","type":"journal-article","article-title":"Review of tissue simulating phantoms with controllable optical, mechanical and structural properties for use in optical coherence tomography","volume":"3","author":"Lamouche","year":"2012","journal-title":"Biomed. Opt. Express"},{"key":"bpexace449bib19","doi-asserted-by":"publisher","DOI":"10.1117\/1.jbo.19.3.036009","type":"journal-article","article-title":"Three-dimensional, distendable bladder phantom for optical coherence tomography and white light cystoscopy","volume":"19","author":"Lurie","year":"2014","journal-title":"J. Biomed. Opt."},{"key":"bpexace449bib20","doi-asserted-by":"publisher","first-page":"1962","DOI":"10.1109\/ultsym.2009.5441472","type":"conference-proceedings","author":"Maggi","year":"2009"},{"key":"bpexace449bib21","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0168375","type":"journal-article","article-title":"Suburothelial bladder contraction detection with implanted pressure sensor","volume":"12","author":"Majerus","year":"2017","journal-title":"PLoS One"},{"key":"bpexace449bib22","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1002\/mrm.1910030612","type":"journal-article","article-title":"New polyvinyl alcohol gel material for MRI phantoms","volume":"3","author":"Mano","year":"1986","journal-title":"Magn. Reson. Med."},{"key":"bpexace449bib23","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1089\/soro.2019.0115","type":"journal-article","article-title":"Toward a common framework and database of materials for soft robotics","volume":"8","author":"Marechal","year":"2021","journal-title":"Soft Robot."},{"key":"bpexace449bib25","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1016\/s0022-5347(17)52384-8","type":"journal-article","article-title":"Upper urinary tract deterioration in patients with myelodysplasia and detrusor hypertonia: A followup study","volume":"129","author":"McGuire","year":"1983","journal-title":"J. Urol."},{"key":"bpexace449bib26","doi-asserted-by":"publisher","author":"Miftahof","year":"2013","DOI":"10.1007\/978-3-642-36146-3","type":"book"},{"key":"bpexace449bib27","doi-asserted-by":"publisher","first-page":"831","DOI":"10.7863\/ultra.15.04085","type":"journal-article","article-title":"Versatile, reusable, and inexpensive ultrasound phantom procedural trainers","volume":"35","author":"Morrow","year":"2016","journal-title":"J. Ultrasound Med."},{"key":"bpexace449bib28","doi-asserted-by":"publisher","first-page":"3088","DOI":"10.1016\/j.jbiomech.2015.07.021","type":"journal-article","article-title":"Bladder tissue biomechanical behavior: experimental tests and constitutive formulation","volume":"48","author":"Natali","year":"2015","journal-title":"J. Biomech."},{"key":"bpexace449bib29","first-page":"333","type":"book","article-title":"Pelvis and perineum","author":"Netter","year":"2019","edition":"7th edn"},{"key":"bpexace449bib30","doi-asserted-by":"publisher","first-page":"1209","DOI":"10.1109\/tnsre.2019.2912374","type":"journal-article","article-title":"Real-time bladder pressure estimation for closed-loop control in a detrusor overactivity model","volume":"27","author":"Ouyang","year":"2019","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"bpexace449bib31","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0051499","type":"journal-article","article-title":"Development of polydimethylsiloxane substrates with tunable elastic modulus to study cell mechanobiology in muscle and nerve","volume":"7","author":"Palchesko","year":"2012","journal-title":"PLoS One"},{"key":"bpexace449bib32","doi-asserted-by":"publisher","DOI":"10.1117\/1.2335429","type":"journal-article","article-title":"Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry","volume":"11","author":"Pogue","year":"2006","journal-title":"J. Biomed. Opt."},{"key":"bpexace449bib33","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.rehab.2017.02.008","type":"journal-article","article-title":"What do we know about neurogenic bladder prevalence and management in developing countries and emerging regions of the world","volume":"60","author":"Przydacz","year":"2017","journal-title":"Ann. Phys. Rehabil. Med."},{"key":"bpexace449bib34","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1007\/s11548-010-0476-x","type":"journal-article","article-title":"3D printing based on imaging data: review of medical applications","volume":"5","author":"Rengier","year":"2010","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"bpexace449bib35","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1038\/s41597-020-00715-8","type":"journal-article","article-title":"CT-ORG, a new dataset for multiple organ segmentation in computed tomography","volume":"7","author":"Rister","year":"2020","journal-title":"Sci. Data"},{"key":"bpexace449bib36","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1142\/s2339547816400082","type":"journal-article","article-title":"Understanding the mechanics of the bladder through experiments and theoretical models: Where we started and where we are heading","volume":"04","author":"Roccabianca","year":"2016","journal-title":"Technology"},{"key":"bpexace449bib37","doi-asserted-by":"publisher","first-page":"020014","DOI":"10.1063\/1.5141627","type":"conference-proceedings","article-title":"Analysis of ultrasonography distance accuracy and maximum depth of visualization based-on silicone rubber phantom","volume":"2202","author":"Rohmat","year":"2019"},{"key":"bpexace449bib38","doi-asserted-by":"publisher","first-page":"1243","DOI":"10.1002\/nau.23124","type":"journal-article","article-title":"International continence society good urodynamic practices and terms 2016: Urodynamics, uroflowmetry, cystometry, and pressure-flow study","volume":"36","author":"Rosier","year":"2017","journal-title":"Neurourol. Urodyn."},{"key":"bpexace449bib39","doi-asserted-by":"publisher","first-page":"1918","DOI":"10.1016\/j.ultrasmedbio.2018.04.008","type":"journal-article","article-title":"A low-cost, durable and re-usable bladder phantom: teaching intravesical ultrasound contrast administration","volume":"44","author":"Shellikeri","year":"2018","journal-title":"Ultrasound Med. Biol."},{"key":"bpexace449bib40","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s00345-014-1265-x","type":"journal-article","article-title":"Association between the bladder wall thickness and urodynamic findings in patients with spinal cord injury","volume":"33","author":"Silva","year":"2015","journal-title":"World J. Urol."},{"key":"bpexace449bib41","doi-asserted-by":"publisher","first-page":"2385","DOI":"10.1007\/s00345-019-02995-1","type":"journal-article","article-title":"3D printing technology and its role in urological training","volume":"38","author":"Smith","year":"2020","journal-title":"World J. Urol."},{"key":"bpexace449bib42","doi-asserted-by":"publisher","DOI":"10.1117\/12.2036402","type":"conference-proceedings","article-title":"Multilayered disease-mimicking bladder phantom with realistic surface topology for optical coherence tomography","volume":"8945","author":"Smith","year":"2014"},{"key":"bpexace449bib43","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1364\/boe.7.000648","type":"journal-article","article-title":"Multimodal 3D cancer-mimicking optical phantom","volume":"7","author":"Smith","year":"2016","journal-title":"Biomed. Opt. Express"},{"key":"bpexace449bib44","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1002\/nau.21223","type":"journal-article","article-title":"Evidence of central modulation of bladder compliance during filling phase","volume":"31","author":"Smith","year":"2012","journal-title":"Neurourol. Urodyn."},{"key":"bpexace449bib45","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0225821","type":"journal-article","article-title":"Wireless intravesical device for real-time bladder pressure measurement: Study of consecutive voiding in awake minipigs","volume":"14","author":"Soebadi","year":"2019","journal-title":"PLoS One"},{"key":"bpexace449bib46","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1111\/iju.14238","type":"journal-article","article-title":"Novel implantable pressure and acceleration sensor for bladder monitoring","volume":"27","author":"Soebadi","year":"2020","journal-title":"Int. J. Urol."},{"key":"bpexace449bib47","doi-asserted-by":"publisher","first-page":"47025","DOI":"10.1002\/app.47025","type":"journal-article","article-title":"Mechanical responses of Ecoflex silicone rubber: compressible and incompressible behaviors","volume":"136","author":"Steck","year":"2019","journal-title":"J. Appl. Polym. Sci."},{"key":"bpexace449bib24","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/bf02457796","type":"journal-article","article-title":"Passive properties of the urinary bladder in the collection phase","volume":"16","author":"van Mastrigt","year":"1978","journal-title":"Med. Biol. Eng. Comput."},{"key":"bpexace449bib48","doi-asserted-by":"publisher","first-page":"233","DOI":"10.2147\/rru.s205383","type":"journal-article","article-title":"Structural, biomechanical and hemodynamic assessment of the bladder wall in healthy subjects","volume":"11","author":"Volikova","year":"2019","journal-title":"Res. Reports Urol."},{"key":"bpexace449bib49","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.3390\/app12031149","type":"journal-article","article-title":"A new electrode design for direct bladder wall stimulation: a pilot minipig study with chronic testing","volume":"12","author":"Walter","year":"2022","journal-title":"Appl. Sci."},{"key":"bpexace449bib50","doi-asserted-by":"publisher","DOI":"10.1115\/1.4026508","type":"journal-article","article-title":"Silicone-based tissue-mimicking phantom for needle insertion simulation","volume":"8","author":"Wang","year":"2014","journal-title":"J. Med. Devices, Trans. ASME"},{"key":"bpexace449bib51","doi-asserted-by":"publisher","DOI":"10.3390\/proceedings1040566","type":"conference-proceedings","article-title":"In-vivo implantable sensor system for measuring bladder wall movements","author":"Weydts","year":"2017"},{"key":"bpexace449bib52","doi-asserted-by":"publisher","first-page":"714","DOI":"10.1002\/nau.21129","type":"journal-article","article-title":"Bladder compliance what does it represent: can we measure it, and is it clinically relevant","volume":"30","author":"Wyndaele","year":"2011","journal-title":"Neurourol. Urodyn."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T12:01:48Z","timestamp":1775908908000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ace449"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,20]]},"references-count":52,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023,7,20]]},"published-print":{"date-parts":[[2023,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ace449","relation":{"has-review":[{"id-type":"doi","id":"10.1088\/2057-1976\/ACE449\/v2\/review2","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/ACE449\/v2\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/ACE449\/v2\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/ACE449\/v1\/review2","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/ACE449\/v1\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/ACE449\/v2\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/ACE449\/v1\/decision1","asserted-by":"object"}]},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,20]]},"assertion":[{"value":"Urinary bladder phantom mimicking mechanical properties and pressure during filling","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-03-10","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-07-05","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-07-20","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}