{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T13:21:33Z","timestamp":1790083293933,"version":"4.0.1"},"reference-count":12,"publisher":"IOP Publishing","issue":"6","license":[{"start":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T00:00:00Z","timestamp":1698710400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T00:00:00Z","timestamp":1698710400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2023,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Purpose.<\/jats:italic> To show the considerations followed for MR-linac in shielding design for the first MR-linac in Mexico following the national clinical necessities. <jats:italic>Method.<\/jats:italic> The National Council on Radiation Protection and Measurements (NCRP) 151 recommendations were followed for the shielding design for primary and secondary barriers and the door design. The calculations were made considering the clinical demands in the country, that is, intensity modulated (IMRT) and 3D conformal radiotherapy (3DC-RT) in 80%\u201320% proportion. <jats:italic>Results.<\/jats:italic> The values obtained in the level survey fully comply with the limits established by the national regulatory authority and with those recommended by the International Commission on Radiological Protection (ICRP) for public and occupational exposures. <jats:italic>Conclusion.<\/jats:italic> It is remarkable that the workload may increase or that the doses per patient may increase considering occupancy factors, which would allow the introduction of hypofractionated techniques with the same number of patients considered in this work without the need to make modifications in the bunker design.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad04e9","type":"journal-article","created":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T18:22:24Z","timestamp":1697739744000},"page":"067003","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Considerations for MR-linac bunker shielding design"],"prefix":"10.1088","volume":"9","author":[{"given":"Mar\u00eda del Sol","family":"Quintero Castel\u00e1n","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian Estrada","family":"Hern\u00e1ndez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pablo Abel Chee","family":"Ch\u00e1vez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5543-3047","authenticated-orcid":false,"given":"Jos\u00e9 Alejandro","family":"Rojas-L\u00f3pez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2023,10,31]]},"reference":[{"key":"bpexad04e9bib1","author":"Elekta Unity Site Planning Guide","year":"2021","type":"other"},{"key":"bpexad04e9bib2","author":"Deye","year":"2005","type":"report"},{"key":"bpexad04e9bib3","author":"Martin","year":"2002","edition":"3rd edn","type":"other"},{"key":"bpexad04e9bib4","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab4916","type":"journal-article","article-title":"Linear accelerator bunker shielding for stereotactic radiotherapy","volume":"64","author":"Rijken","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"bpexad04e9bib5","doi-asserted-by":"publisher","first-page":"6712","DOI":"10.1038\/s41598-022-10498-0","type":"journal-article","article-title":"Compact bunker shielding assessment for 1.5 T MR-Linac","volume":"12","author":"Sung","year":"2022","journal-title":"Sci Rep."},{"key":"bpexad04e9bib6","first-page":"37","type":"book","article-title":"International Commission on Radiological Protection, Publication 103. The 2007 recommendations of the International Commission on Radiological Protection","author":"Valentin","year":"2007"},{"key":"bpexad04e9bib7","author":"Reglamento General de Seguridad Radiol\u00f3gica","year":"1988","type":"other"},{"key":"bpexad04e9bib8","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1120\/jacmp.v16i5.5768)","type":"journal-article","article-title":"(MPPG) for commissioning and QA of external beam treatment planning system (TPS) dose calculations","volume":"16","author":"Medical Physics Practice Guideline","year":"2023","journal-title":"American Association of Physicists in Medicine"},{"key":"bpexad04e9bib9","first-page":"28","type":"journal-article","author":"Government of Baja California. Official statement","year":"2023","journal-title":"Tiene baja california elevada sobrevida en c\u00e1ncer."},{"key":"bpexad04e9bib10","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.radonc.2020.06.044","type":"journal-article","article-title":"Prostate intrafraction motion during the preparation and delivery of MR-guided radiotherapy sessions on a 1.5T MR-Linac","volume":"151","author":"de Muinck Keizer","year":"2020","journal-title":"Radiother. Oncol."},{"key":"bpexad04e9bib11","type":"journal-article","article-title":"Initial clinical experience of stereotactic body radiation therapy (SBRT) for liver metastases, primary liver malignancy, and pancreatic cancer with 4D-MRI based online adaptation and real-time MRI monitoring using a 1.5 Tesla MR-linac","volume":"15","author":"Hall","year":"2020","journal-title":"PLoS One"},{"key":"bpexad04e9bib12","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1016\/j.rpor.2020.06.002","type":"journal-article","article-title":"Radiation oncology in Mexico: current status according to Mexico\u2019s radiation oncology certification board","volume":"25","author":"Maldonado Magos","year":"2020","journal-title":"Rep Pract Oncol Radiother."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T14:07:07Z","timestamp":1760191627000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad04e9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,31]]},"references-count":12,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023,10,31]]},"published-print":{"date-parts":[[2023,11,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad04e9","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,31]]},"assertion":[{"value":"Considerations for MR-linac bunker shielding design","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-05-25","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-10-19","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-10-31","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}