{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T03:25:51Z","timestamp":1771644351826,"version":"3.50.1"},"reference-count":57,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2023,12,14]],"date-time":"2023-12-14T00:00:00Z","timestamp":1702512000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2023,12,14]],"date-time":"2023-12-14T00:00:00Z","timestamp":1702512000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100010067","name":"Gobierno de Arag\u00f3n","doi-asserted-by":"crossref","award":["E44-23R"],"award-info":[{"award-number":["E44-23R"]}],"id":[{"id":"10.13039\/501100010067","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> A detailed analysis of the corneal retardation time <jats:italic>\u03c4<\/jats:italic> as a highly related parameter to the intraocular pressure (IOP), and its plausible role as an indicator of ocular hypertension disease. <jats:italic>Approach.<\/jats:italic> A simple theoretical expression for <jats:italic>\u03c4<\/jats:italic> is derived within the corneal viscoelastic model of Kelvin-Voigt with 3 elements. This retardation time can be easily calculated from the well-known signal and pressure amplitudes of non-contact tonometers like the Ocular Response Analyzer (ORA). Then, a population-based study was performed where 100 subjects aged from 18 to 30 were analyzed (within this group, about 10% had an elevated IOP with more than 21 mmHg). <jats:italic>Main results.<\/jats:italic> A clear relationship between the corneal retardation time and the corneal-compensated intraocular pressure (IOP<jats:sub>cc<\/jats:sub>) was found, underlying the risk for ocular hypertensive (OHT) subjects with lower <jats:italic>\u03c4<\/jats:italic> values to develop hypertension illnesses (due to the inability of poorly viscoelastic corneas to absorb IOP fluctuations, resulting in probable optic nerve damage). <jats:italic>Significance.<\/jats:italic> Our results might provide an useful tool to systematically discern which OHT patients (and even those with normal IOP values) are more likely to suffer glaucoma progression and, consequently, ensure an early diagnosis.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad12fa","type":"journal-article","created":{"date-parts":[[2023,12,6]],"date-time":"2023-12-06T22:44:35Z","timestamp":1701902675000},"page":"015014","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Corneal retardation time as an ocular hypertension disease indicator"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7502-9164","authenticated-orcid":true,"given":"Oscar","family":"del Barco","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9068-7728","authenticated-orcid":true,"given":"Francisco J","family":"\u00c1vila","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7516-3029","authenticated-orcid":false,"given":"Concepci\u00f3n","family":"Marcell\u00e1n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3979-4528","authenticated-orcid":false,"given":"Laura","family":"Rem\u00f3n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2023,12,14]]},"reference":[{"key":"bpexad12fabib1","doi-asserted-by":"publisher","first-page":"434","DOI":"10.3928\/1081597X-20170426-02","article-title":"Integration of scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection","volume":"33","author":"Ambr\u00f3sio","year":"2017","journal-title":"J. Refract. Surg."},{"key":"bpexad12fabib2","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1097\/00055735-200304000-00006","article-title":"Collaborative normal tension glaucoma study","volume":"14","author":"Anderson","year":"2003","journal-title":"Curr. Opin. Ophthalmol."},{"key":"bpexad12fabib3","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0121486","article-title":"Coupled biomechanical response of the cornea assessed by non-contact tonometry a simulation study","volume":"10","author":"Ariza-Gracia","year":"2015","journal-title":"PLoS One"},{"key":"bpexad12fabib4","doi-asserted-by":"publisher","first-page":"B71","DOI":"10.1364\/JOSAA.36.000B71","article-title":"Data analysis of the ocular response analyzer for improved distinction and detection of glaucoma","volume":"36","author":"Asejczk-Widlicka","year":"2019","journal-title":"J. Opt. Soc. Am. A"},{"key":"bpexad12fabib5","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.ogla.2021.04.002","article-title":"Agreement of intraocular pressure measurement of icare ic200 with goldmann applanation tonometer in adult eyes with normal cornea ophthalmol","volume":"4","author":"Badakere","year":"2021","journal-title":"Glaucoma"},{"key":"bpexad12fabib6","doi-asserted-by":"publisher","author":"Brinson","year":"2008","DOI":"10.1007\/978-0-387-73861-1"},{"key":"bpexad12fabib7","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1097\/IJG.0000000000000948","article-title":"The influence of corneal biomechanical properties on intraocular pressure measurements using a rebound self-tonometer","volume":"27","author":"Brown","year":"2018","journal-title":"J. Glaucoma"},{"key":"bpexad12fabib8","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1080\/02713683.2022.2059809","article-title":"Corneal biomechanics assessment with ultra high speed scheimpflug camera in primary open angle glaucoma compared with healthy subjects: a meta-analysis of the literature","volume":"48","author":"Catania","year":"2023","journal-title":"Curr. Eye Res."},{"key":"bpexad12fabib9","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1097\/IJG.0000000000000354","article-title":"Automated detection of glaucoma from topographic features of the optic nerve head in color fundus photographs","volume":"25","author":"Chakrabarti","year":"2016","journal-title":"J. Glaucoma"},{"key":"bpexad12fabib10","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1097\/IJG.0000000000001819","article-title":"Changes in corneal biomechanics and glaucomatous visual field loss","volume":"30","author":"Chan","year":"2021","journal-title":"J. Glaucoma"},{"key":"bpexad12fabib11","first-page":"3197","volume":"60","author":"Consejo","year":"2019","journal-title":"Corneal Properties of Keratoconus Based on Scheimpflug Light Intensity Distribution Investig. Ophthalmol. Vis. Sci."},{"key":"bpexad12fabib12","doi-asserted-by":"publisher","first-page":"1704","DOI":"10.1167\/iovs.11-8186","article-title":"Effect of treatment on the rate of visual field change in the ocular hypertension treatment study observation group","volume":"53","author":"De Moraes","year":"2012","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"bpexad12fabib13","doi-asserted-by":"publisher","first-page":"2637","DOI":"10.3390\/jcm10122637","article-title":"Corneal biomechanical parameters and central corneal thickness in glaucoma patients, glaucoma suspects, and a healthy population","volume":"10","author":"Del Buey-Sayas","year":"2021","journal-title":"J. Clin. Med."},{"key":"bpexad12fabib14","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1097\/ICU.0000000000000130","article-title":"Corneal hysteresis and its relevance to glaucoma","volume":"26","author":"Deol","year":"2015","journal-title":"Curr. Opin. Ophthalmol."},{"key":"bpexad12fabib15","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s11043-016-9317-9","article-title":"Visco-elastic and thermal-induced damaging in time-dependent reshaping of human cornea after conductive keratoplasty","volume":"21","author":"Fraldi","year":"2016","journal-title":"Mech. Time-Depend. Mater."},{"key":"bpexad12fabib16","volume":"2014","author":"Garcia-Porta","year":"2014","journal-title":"Corneal biomechanical properties in different ocular conditions and new measurement techniques ISRN Ophthalmol"},{"key":"bpexad12fabib17","first-page":"36","article-title":"Evaluating biomechanic properties of the cornea Cataract. Refract","volume":"25","author":"Gatinel","year":"2007","journal-title":"Surg. Today Eur."},{"key":"bpexad12fabib18","first-page":"693","author":"Geevarghese","year":"2021","journal-title":"Optical Coherence Tomography and Glaucoma Annu. Rev. Vis. Sci. 15;7"},{"key":"bpexad12fabib19","doi-asserted-by":"publisher","first-page":"3919","DOI":"10.1167\/iovs.07-1321","article-title":"A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis","volume":"49","author":"Glass","year":"2008","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"bpexad12fabib20","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1097\/ICO.0b013e318164e49d","article-title":"Pilot study on the influence of corneal biomechanical properties over the short term in response to corneal refractive therapy for myopia","volume":"27","author":"Gonz\u00e1lez-M\u00e9ijome","year":"2008","journal-title":"Cornea"},{"key":"bpexad12fabib21","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1097\/IJG.0b013e318220daf0","article-title":"Assessment of corneal biomechanical properties in normal tension glaucoma and comparison with open-angle glaucoma, ocular hypertension, and normal eyes","volume":"21","author":"Grise-Dulac","year":"2012","journal-title":"J. Glaucoma"},{"key":"bpexad12fabib22","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1097\/IJG.0b013e31815c3ad3","article-title":"Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, ocular response analyzer, and Goldmann tonometry in glaucomatous eyes","volume":"17","author":"Hager","year":"2008","journal-title":"J. Glaucoma"},{"key":"bpexad12fabib23","doi-asserted-by":"publisher","first-page":"208","DOI":"10.3928\/1081597X-20140212-02","article-title":"Air puff induced corneal vibrations: theoretical simulations and clinical observations","volume":"30","author":"Han","year":"2014","journal-title":"J. Refract. Surg."},{"key":"bpexad12fabib24","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s11043-018-9390-3","article-title":"Numerical and clinical investigation on the material model of the cornea in Corvis tonometry tests: differentiation between hyperelasticity and viscoelasticity","volume":"23","author":"Jannesari","year":"2018","journal-title":"Mech. Time Depend. Mater."},{"key":"bpexad12fabib25","first-page":"2395\u2013A0198","article-title":"Rheological eye model to determine elastic and viscoelastic properties of the cornea and crystalline lens","volume":"63","author":"Jimenez-Villar","year":"2022","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"bpexad12fabib26","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1001\/archopht.120.6.701","article-title":"The ocular hypertension treatment study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma","volume":"120","author":"Kass","year":"2002","journal-title":"Arch. Ophthalmol."},{"key":"bpexad12fabib27","doi-asserted-by":"publisher","first-page":"17","DOI":"10.5005\/jp-journals-10008-1103","article-title":"Ocular response analyzer","volume":"6","author":"Kaushik","year":"2012","journal-title":"J. Curr. Glaucoma Pract."},{"key":"bpexad12fabib28","article-title":"Solid mechanics part I: an introduction to solid mechanics","author":"Kelly","year":"2013"},{"key":"bpexad12fabib29","doi-asserted-by":"publisher","first-page":"1460","DOI":"10.1002\/cnm.2667","article-title":"Calibrating corneal material model parameters using only inflation data: an ill-posed problem","volume":"30","author":"Kok","year":"2014","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"bpexad12fabib30","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/B978-0-7020-5193-7.00010-8","article-title":"Tonometry and intraocular pressure fluctuation","volume":"1","author":"Kotecha","year":"2015","journal-title":"Glaucoma"},{"key":"bpexad12fabib31","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0206564","article-title":"Utility of Goldmann applanation tonometry for monitoring intraocular pressure in glaucoma patients with a history of laser refractory surgery","volume":"13","author":"Lee","year":"2018","journal-title":"PLoS One"},{"key":"bpexad12fabib32","doi-asserted-by":"publisher","first-page":"4171","DOI":"10.1167\/iovs.19-27087","article-title":"Association of corneal hysteresis with lamina cribrosa curvature in primary open angle glaucoma","volume":"60","author":"Lee","year":"2019","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"bpexad12fabib33","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1097\/ICU.0b013e3282f4b1c2","article-title":"New developments in scanning laser polarimetry for glaucoma","volume":"19","author":"Lemij","year":"2008","journal-title":"Curr. Opin. Opthalmol."},{"key":"bpexad12fabib34","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.jcrs.2004.09.031","article-title":"Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis","volume":"31","author":"Liu","year":"2005","journal-title":"J. Cataract Refract. Surg."},{"key":"bpexad12fabib35","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2019.103575","article-title":"Characterization of hyperelastic mechanical properties for youth corneal anterior central stroma based on collagen fibril crimping constitutive model","volume":"103","author":"Liu","year":"2020","journal-title":"J. Mech. Behav. J. Mech. Behav."},{"key":"bpexad12fabib36","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","article-title":"Determining in vivo biomechanical properties of the cornea with an ocular response analyzer","volume":"31","author":"Luce","year":"2005","journal-title":"J. Cararact. Refract. Surg."},{"key":"bpexad12fabib37","doi-asserted-by":"publisher","DOI":"10.1002\/jbio.201800154","article-title":"Assessment of the influence of viscoelasticity of cornea in animal ex vivo model using air-puff optical coherence tomography and corneal hysteresis","volume":"12","author":"Maczynska","year":"2019","journal-title":"J. Biophotonics"},{"key":"bpexad12fabib38","doi-asserted-by":"publisher","first-page":"2801","DOI":"10.1007\/s10792-022-02270-0","article-title":"Corneal hysteresis and intraocular pressure are altered in silicone-hydrogel soft contact lenses wearers","volume":"42","author":"Marcell\u00e1n","year":"2022","journal-title":"Int. Ophthalmol."},{"key":"bpexad12fabib39","doi-asserted-by":"crossref","first-page":"4410","DOI":"10.1167\/iovs.06-0158","article-title":"Ocular response analyzer versus goldmann applanation tonometry for intraocular pressure measurements","volume":"47","author":"Martinez","year":"2006","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"bpexad12fabib40","doi-asserted-by":"crossref","first-page":"9","DOI":"10.2147\/OPTH.S186526","article-title":"Investigation of intraocular pressure fluctuation as a risk factor of glaucoma progression","volume":"13","author":"Matlach","year":"2019","journal-title":"Clin. Ophthalmol."},{"key":"bpexad12fabib41","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0176380","article-title":"Using CorvisST tonometry to assess glaucoma progression","volume":"12","author":"Matsuura","year":"2017","journal-title":"PLoS One"},{"key":"bpexad12fabib42","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1097\/01.ijg.0000212268.42606.97","article-title":"Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer","volume":"15","author":"Medeiros","year":"2006","journal-title":"J. Glaucoma"},{"key":"bpexad12fabib43","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12886-016-0396-9","article-title":"Corneal hysteresis in patients with glaucoma-like optic discs, ocular hypertension and glaucoma","volume":"17","author":"Murphy","year":"2017","journal-title":"BMC Ophthalmol."},{"key":"bpexad12fabib44","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1016\/j.jcrs.2007.04.021","article-title":"Corneal biomechanical properties in normal, postlaser in situ keratomileusis, and keratoconic eyes","volume":"33","author":"Ortiz","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"bpexad12fabib45","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1080\/02713683.2022.2088798","article-title":"Keratoconus: A Biomechanical Perspective","volume":"48","author":"Padmanabhan","year":"2023","journal-title":"Curr. Eye Res."},{"key":"bpexad12fabib46","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1111\/j.1442-9071.2012.02790.x","article-title":"Association between corneal biomechanical properties and optic nerve head morphology in newly diagnosed glaucoma patients","volume":"40","author":"Prata","year":"2012","journal-title":"Clin. Experiment. Ophthalmol."},{"key":"bpexad12fabib47","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1016\/j.jcrs.2014.04.019","article-title":"Concepts and misconceptions in corneal biomechanics","volume":"40","author":"Roberts","year":"2014","journal-title":"J. Cararact. Refract. Surg."},{"key":"bpexad12fabib48","first-page":"4720","article-title":"Comparison of elastic and viscoelastic biomechanical metrics in ocular hypertension and normal controls","volume":"64","author":"Roberts","year":"2023","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"bpexad12fabib49","doi-asserted-by":"crossref","first-page":"9174","DOI":"10.1167\/iovs.11-7395","article-title":"Patient-specific computational modeling of keratoconus progression and differential responses to collagen cross-linking","volume":"52","author":"Roy","year":"2011","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"bpexad12fabib50","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1016\/j.jcrs.2014.03.020","article-title":"Biomechanical and optical behavior of human corneas before and after photorefractive keratectomy","volume":"40","author":"S\u00e1nchez","year":"2014","journal-title":"J. Cataract Refract. Surg."},{"key":"bpexad12fabib51","doi-asserted-by":"publisher","first-page":"S17","DOI":"10.1016\/j.survophthal.2008.08.003","article-title":"Diagnostic tools for glaucoma detection and management","volume":"53","author":"Sharma","year":"2008","journal-title":"Surv. Ophthalmol."},{"key":"bpexad12fabib52","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.jmps.2016.04.012","article-title":"Theoretical and numerical analysis of the corneal air puff test","volume":"93","author":"Simonini","year":"2016","journal-title":"J. Mech. Phys. Solids"},{"key":"bpexad12fabib53","doi-asserted-by":"publisher","first-page":"1640","DOI":"10.1016\/j.ophtha.2019.07.023","article-title":"Corneal biomechanics and visual field progression in eyes with seemingly well-controlled intraocular pressure","volume":"126","author":"Susanna","year":"2019","journal-title":"Ophthalmology"},{"key":"bpexad12fabib54","doi-asserted-by":"publisher","first-page":"8354","DOI":"10.1038\/s41598-022-12151-2","article-title":"Torsional wave elastography to assess the mechanical properties of the cornea","volume":"12","author":"Torres","year":"2022","journal-title":"Sci. Rep."},{"key":"bpexad12fabib55","doi-asserted-by":"publisher","DOI":"10.1016\/j.mam.2023.101193","article-title":"Neuroprotection in glaucoma: Mechanisms beyond intraocular pressure lowering","volume":"92","author":"Tribble","year":"2023","journal-title":"Mol. Aspects Med."},{"key":"bpexad12fabib56","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s10237-017-0942-2","article-title":"A viscoelastic anisotropic hyperelastic constitutive model of the human cornea","volume":"17","author":"Whitford","year":"2018","journal-title":"Biomech. Model. Mechanobiol."},{"key":"bpexad12fabib57","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1097\/APO.0000000000000085","article-title":"Confocal scan laser ophthalmoscope for diagnosing glaucoma: a systematic review and meta-analysis","volume":"4","author":"Yaghoubi","year":"2015","journal-title":"Asia Pac. J. Ophthalmol."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:24:28Z","timestamp":1749914668000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad12fa"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,14]]},"references-count":57,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12,14]]},"published-print":{"date-parts":[[2024,1,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad12fa","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,14]]},"assertion":[{"value":"Corneal retardation time as an ocular hypertension disease indicator","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2023 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-09-19","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-12-06","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2023-12-14","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}