{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T09:59:49Z","timestamp":1771235989554,"version":"3.50.1"},"reference-count":38,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T00:00:00Z","timestamp":1707436800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T00:00:00Z","timestamp":1707436800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Background<\/jats:italic>. Magnetocardiography (MCG) is a non-invasive and non-contact technique that measures weak magnetic fields generated by the heart. It is highly effective in the diagnosis of heart abnormalities. Multichannel MCG provides detailed spatio-temporal information of the measured magnetic fields. While multichannel MCG systems are costly, usage of the optimal number of measurement channels to characterize cardiac magnetic fields without any appreciable loss of signal information would be economically beneficial and promote the widespread use of MCG technology. <jats:italic>Methods<\/jats:italic>. An optimization method based on the sequential selection approach is used to choose channels containing the maximum signal information while avoiding redundancy. The study comprised 40 healthy individuals, along with two subjects having ischemic heart disease and one subject with premature ventricular contraction. MCG measured using a 37 channel MCG system. After revisiting the existing methods of optimization, the mean error and correlation of the optimal set of measurement channels with those of all 37 channels are evaluated for different sets, and it has been found that 18 channels are adequate. <jats:italic>Results<\/jats:italic>. The chosen 18 optimal channels exhibited a strong correlation (0.99 \u00b1 0.006) between the original and reconstructed magnetic field maps for a cardiac cycle in healthy subjects. The root mean square error is 0.295 pT, indicating minimal deviation. <jats:italic>Conclusion<\/jats:italic>. This selection method provides an efficient approach for choosing MCG, which could be used for minimizing the number of channels as well as in practical unforeseen measurement conditions where few channels are noisy during the measurement.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad233e","type":"journal-article","created":{"date-parts":[[2024,1,26]],"date-time":"2024-01-26T22:50:23Z","timestamp":1706309423000},"page":"025023","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Enhancing the efficiency and cost-effectiveness of magnetocardiography by optimal channel selection for cardiac diagnosis"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2843-7963","authenticated-orcid":false,"given":"C","family":"Kesavaraja","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4444-7918","authenticated-orcid":false,"given":"S","family":"Sengottuvel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rajesh","family":"Patel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raja J","family":"Selvaraj","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Santhosh","family":"Satheesh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7215-6897","authenticated-orcid":false,"given":"Awadhesh","family":"Mani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,2,9]]},"reference":[{"key":"bpexad233ebib1","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1586\/14737159.5.3.291","article-title":"Clinical application of magnetocardiography","volume":"5","author":"Fenici","year":"2005","journal-title":"Expert Rev. Mol. Diagn."},{"key":"bpexad233ebib2","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/S1880-4276(08)80002-6","article-title":"Magnetocardiography in early detection of electromagnetic abnormality in ischemic heart disease","volume":"24","author":"Watanabe","year":"2008","journal-title":"Journal of Arrhythmia"},{"key":"bpexad233ebib3","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.jelectrocard.2019.07.009","article-title":"Clinical utility of magnetocardiography in cardiology for the detection of myocardial ischemia","volume":"57","author":"Camm","year":"2019","journal-title":"Journal of Electrocardiology"},{"key":"bpexad233ebib4","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1016\/j.jelectrocard.2007.03.013","article-title":"Detection of patients with coronary artery disease using cardiac magnetic field mapping at rest","volume":"40","author":"Gapelyuk","year":"2007","journal-title":"Journal of Electrocardiology"},{"key":"bpexad233ebib5","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1016\/j.amjcard.2008.10.013","article-title":"Usefulness of magnetocardiogram to detect unstable angina pectoris and non-ST elevation myocardial infarction","volume":"103","author":"Lim","year":"2009","journal-title":"The American Journal of Cardiology"},{"key":"bpexad233ebib6","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1016\/j.ijcard.2016.11.165","article-title":"Incremental diagnostic value of combined quantitative and qualitative parameters of magnetocardiography to detect coronary artery disease","volume":"228","author":"Shin","year":"2017","journal-title":"Int. J. Cardiol."},{"key":"bpexad233ebib7","volume":"II","author":"Clarke","year":"2006"},{"key":"bpexad233ebib8","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/3\/1\/015008","article-title":"A portable diagnostic device for cardiac magnetic field mapping","volume":"3","author":"Mooney","year":"2017","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexad233ebib9","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1002\/ecj.11645","article-title":"Development of a one-dimensional fluxgate array and its application to magnetocardiogram measurements","volume":"98","author":"Harada","year":"2015","journal-title":"Electron. Commun. Jpn."},{"key":"bpexad233ebib10","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcha.2019.100466","article-title":"A 90-second magnetocardiogram using a novel analysis system to assess for coronary artery stenosis in emergency department observation unit chest pain patients","volume":"26","author":"Pena","year":"2020","journal-title":"IJC Heart & Vasculature"},{"key":"bpexad233ebib11","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1109\/TBME.1971.4502813","article-title":"Selection of the number and positions of measuring locations for electrocardiography","volume":"2","author":"Barr","year":"1971","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"bpexad233ebib12","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1109\/TBME.1978.326332","article-title":"Limited lead selection for estimation of body surface potential maps in electrocardiography","volume":"3","author":"Lux","year":"1978","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexad233ebib13","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.jelectrocard.2008.02.004","article-title":"Lead selection: old and new methods for locating the most electrocardiogram information","volume":"41","author":"Donnelly","year":"2008","journal-title":"Journal of Electrocardiology"},{"key":"bpexad233ebib14","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.jelectrocard.2007.07.001","article-title":"Evaluation of lead selection methods for optimal reconstruction of body surface potentials","volume":"41","author":"Guillem","year":"2008","journal-title":"Journal of Electrocardiology"},{"key":"bpexad233ebib15","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1109\/TITB.2008.2011894","article-title":"How Many leads are necessary for a reliable reconstruction of surface potentials during atrial fibrillation","volume":"13","author":"de la Salud Guillem","year":"2009","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"bpexad233ebib16","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.jelectrocard.2020.02.017","article-title":"Reduced leadset selection and performance evaluation in the inverse problem of electrocardiography for reconstructing the ventricularly paced electrograms","volume":"60","author":"Gharbalchi No","year":"2020","journal-title":"Journal of Electrocardiology"},{"key":"bpexad233ebib17","first-page":"174","article-title":"Selection of optimal recording sites in electrocardiography and magnetocardiography Biomed. Eng","volume":"48","author":"Jazbin\u0161ek","year":"2004","journal-title":"Biomed. Tech."},{"key":"bpexad233ebib18","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1016\/j.ics.2007.01.060","article-title":"Influence of limited lead selection on source localization in magnetocardiography and electrocardiography","volume":"1300","author":"Jazbin\u0161ek","year":"2007","journal-title":"International Congress Series"},{"key":"bpexad233ebib19","volume":"1","author":"Clarke","year":"2004"},{"key":"bpexad233ebib20","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1063\/1.4710279","article-title":"Establishment of 37 channel SQUID system for magnetocardiography","volume":"1447","author":"Parasakthi","year":"2012","journal-title":"AIP Conference Proceedings"},{"key":"bpexad233ebib21","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1109\/72.761722","article-title":"Fast and robust fixed-point algorithms for independent component analysis","volume":"10","author":"Hyvarinen","year":"1999","journal-title":"IEEE Trans. Neural Networks"},{"key":"bpexad233ebib22","first-page":"36","article-title":"SQUID-based measurement of biomagnetic fields","volume":"99","author":"Janawadkar","year":"2010","journal-title":"Curr. Sci."},{"key":"bpexad233ebib23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1472-6947-6-9","article-title":"Selection of optimal recording sites for limited lead body surface potential mapping: a sequential selection based approach","volume":"6","author":"Finlay","year":"2006","journal-title":"BMC Med. Inf. Decis. Making"},{"key":"bpexad233ebib24","doi-asserted-by":"publisher","first-page":"343.e1\u2013e11","DOI":"10.1016\/j.jelectrocard.2006.08.002","article-title":"Vectorcardiographic lead systems for the characterization of atrial fibrillation","volume":"40","author":"van Oosterom","year":"2007","journal-title":"Journal of Electrocardiology"},{"key":"bpexad233ebib25","doi-asserted-by":"publisher","DOI":"10.1111\/anec.12715","article-title":"Magnetocardiography for identification of coronary ischemia in patients with chest pain and normal resting 12-lead electrocardiogram","volume":"25","author":"Ramesh","year":"2020","journal-title":"Annals of Non-invasive Electrocardiology"},{"key":"bpexad233ebib26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1477-044X-4-5","article-title":"Pseudo current density maps of electrophysiological heart, nerve or brain function and their physical basis","volume":"4","author":"Haberkorn","year":"2006","journal-title":"Biomagnetic research and technology"},{"key":"bpexad233ebib27","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1109\/JBHI.2017.2649570","volume":"22","author":"Zhao","year":"2017"},{"key":"bpexad233ebib28","doi-asserted-by":"publisher","first-page":"1144","DOI":"10.1016\/j.jacep.2019.06.010","article-title":"Non-invasive mapping of premature ventricular contractions by merging magnetocardiography and computed tomography","volume":"5","author":"Aita","year":"2019","journal-title":"JACC: Clinical Electrophysiology"},{"key":"bpexad233ebib29","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1109\/10.846680","article-title":"Conversion of magnetocardiographic recordings between two different multichannel SQUID devices","volume":"47","author":"Burghoff","year":"2000","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexad233ebib30","doi-asserted-by":"publisher","first-page":"1442","DOI":"10.1109\/TMAG.2007.915911","article-title":"Tabu search optimization of magnetic sensor systems for magnetocardiography","volume":"44","author":"Lau","year":"2008","journal-title":"IEEE Trans. Magn."},{"key":"bpexad233ebib31","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1016\/S0921-4534(02)00683-4","article-title":"Comparison of sensor arrangements of MCG and ECG with respect to information content","volume":"372","author":"Nalbach","year":"2002","journal-title":"Physica C"},{"key":"bpexad233ebib32","doi-asserted-by":"publisher","first-page":"754","DOI":"10.3390\/s16060754","article-title":"Optimal magnetic sensor vests for cardiac source imaging","volume":"16","author":"Lau","year":"2016","journal-title":"Sensors"},{"key":"bpexad233ebib33","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1111\/j.1542-474X.2000.tb00380.x","article-title":"Detection of exercise-induced myocardial ischemia by multichannel magnetocardiography in single vessel coronary artery disease","volume":"5","author":"H\u00e4nninen","year":"2000","journal-title":"Annals of Noninvasive Electrocardiology"},{"key":"bpexad233ebib34","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1088\/0031-9155\/46\/4\/305","article-title":"Beat-to-beat analysis method for magnetocardiographic recordings during interventions","volume":"46","author":"Takala","year":"2001","journal-title":"Phys. Med. Biol."},{"key":"bpexad233ebib35","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/S0022-0736(99)90103-6","article-title":"Spatial distribution of QT dispersion measured by magnetocardiography under stress in coronary artery disease","volume":"32","author":"Hailer","year":"1999","journal-title":"Journal of Electrocardiology"},{"key":"bpexad233ebib36","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1046\/j.1471-0528.2002.01057.x","article-title":"Multicentre study of fetal cardiac time intervals using magnetocardiography","volume":"109","author":"Stinstra","year":"2002","journal-title":"BJOG: An International Journal of Obstetrics and Gynaecology"},{"key":"bpexad233ebib37","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1114\/B:ABME.0000036645.35013.ad","article-title":"Age and sex dependent variations in the normal magnetocardiogram compared with changes associated with ischemia","volume":"32","author":"Chen","year":"2004","journal-title":"Ann. Biomed. Eng."},{"key":"bpexad233ebib38","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1111\/j.1540-8159.2008.01011.x","article-title":"Space-time database for standardization of adult magnetocardiogram-making standard MCG parameters","volume":"31","author":"Kandori","year":"2008","journal-title":"Pacing and Clinical Electrophysiology"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:32:05Z","timestamp":1749915125000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad233e"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,9]]},"references-count":38,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,2,9]]},"published-print":{"date-parts":[[2024,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad233e","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,9]]},"assertion":[{"value":"Enhancing the efficiency and cost-effectiveness of magnetocardiography by optimal channel selection for cardiac diagnosis","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-11-01","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-01-26","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-09","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}